期刊文献+
共找到57篇文章
< 1 2 3 >
每页显示 20 50 100
Effects of Standing Time during Pretreatment on the Nitrite Concentration Detected by Spectrophotometric Method
1
作者 Yingfei Zeng Juan Hu +2 位作者 Xianglong Bian Qianfeng Xia Tingwei Hu 《Journal of Materials Science and Chemical Engineering》 2024年第2期73-83,共11页
Food safety problems caused by excessive nitrite addition have been frequently reported and the detection of nitrite in food is particularly important. The standing time during the pretreatment of primary sample has a... Food safety problems caused by excessive nitrite addition have been frequently reported and the detection of nitrite in food is particularly important. The standing time during the pretreatment of primary sample has a great influence on the concentration of nitrite tested by spectrophotometric method. In this context, three kinds of food samples are prepared, including canned mustard, canned fish and home-made pickled water. A series of standing times are placed during the sample pretreatments and the corresponding nitrite contents in these samples are detected by spectrophotometric method based on N-ethylenediamine dihydrochloride. This study aims to find out a reasonable standing time during the pretreatment of food sample, providing influence factor for precise detection of nitrite. 展开更多
关键词 Standing Time spectrophotometric Method Nitrite Detection
下载PDF
Catalytic spectrophotometric determination of trace selenium in microemulsion after separation and enrichment by SDG 被引量:6
2
作者 LI Huizhi ZHAI Diantang FAN Yingju 《Rare Metals》 SCIE EI CAS CSCD 2006年第3期281-286,共6页
A new catalytic spectrophotometric method was developed for the determination of trace amount of Se(Ⅳ) in microemulsion medium. The method is based on the catalytic effect of traces of Se(Ⅳ) on the oxidation of ... A new catalytic spectrophotometric method was developed for the determination of trace amount of Se(Ⅳ) in microemulsion medium. The method is based on the catalytic effect of traces of Se(Ⅳ) on the oxidation of 2',4'-dichlorophenylfluomne (p-CPF) by potassium bromate with HNO3 as an activator in the presence of nonionic microemulsion medium. Under optimum conditions, the calibration graph is linear in the range of 0.4-15 μg·L^-1 of Se(Ⅳ) at 480 nm. The detection limit achieved is 9.86 × 10^-10μg·L^-1. Samples were dissolved and the obtained trace Se(Ⅳ) was separated and enriched by sulphydryl dextrane gel (SDG). The method has been applied for determination of trace selenium with satisfactory results. 展开更多
关键词 analytical chemistry Se(Ⅳ) catalytic spectrophotometric microemulsion medium SEPARATION ENRICHMENT
下载PDF
Solid-phase extraction of trace Au(Ⅲ) with SDG and determination by the catalytic spectrophotometric method 被引量:2
3
作者 LI Huizhi ZHAI Yubo 《Rare Metals》 SCIE EI CAS CSCD 2008年第6期560-565,共6页
The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ... The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results. 展开更多
关键词 analytical chemistry catalytic kinetic spectrophotometric method solid-phase extraction gold(Ⅲ)
下载PDF
Indirect Spectrophotometric Determination of Sulphide with the Complex of Cd(Ⅱ)-5-Br-PADAP-CPB 被引量:1
4
作者 Zhen Yu Zhang Wei An Liang(Department of Chemistry, Shandong University, Jinan 250100) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第11期983-984,共2页
By the use of CPB, Cd(Ⅲ) forms a highly sensitive complex with 5-Br-PADAP in aqueous solution, molar absorptivity εis 1. 21 ×105 1. mol-1. cm-1.Trace amount of sulphide can be determined from its effect on the... By the use of CPB, Cd(Ⅲ) forms a highly sensitive complex with 5-Br-PADAP in aqueous solution, molar absorptivity εis 1. 21 ×105 1. mol-1. cm-1.Trace amount of sulphide can be determined from its effect on the complex of Cd (Ⅲ)-5-Br-PADAP-CPB, sulphide in the range 0~3. 2 ×10-6mol dm-3 causes a decrease in absorption, that is a linear function of the concentration, For 13ng cm-3 sulphide, common metal ions such as Na+, K+, Ca2+, Mg2+, Al3+ and anions such as CO (24μg cm-3). S2O (22μg cm-3). PO (20μg cm-3) etc. do not interfere. A method for the indirect determination of sulphide in beer and in dustrial waste water with good selectivity and accuracy is described. 展开更多
关键词 CPB Br-PADAP-CPB Indirect spectrophotometric Determination of Sulphide with the Complex of Cd
下载PDF
Spectrophotometric Determination of Fluoride in Groundwater Using Resorcin Blue Complexes 被引量:1
5
作者 Zaher Barghouthi Sameer Amereih 《American Journal of Analytical Chemistry》 2012年第9期651-655,共5页
New simple and sensitive spectrophotometric determination of fluoride in drinking groundwater has been developed using aluminium-resorcin blue complex. The method is based on the reaction of fluoride with the coloured... New simple and sensitive spectrophotometric determination of fluoride in drinking groundwater has been developed using aluminium-resorcin blue complex. The method is based on the reaction of fluoride with the coloured complex to produce colourless aluminium fluoride complex and releasing of the free ligand. The relationship of the reaction of flu-oride with the complex is sixth-order polynomial function. The reaction reaches equilibrium at fluoride concentration of 0.054 mM. The equilibrium constant (Keq) was calculated as 1.12 × 1014. Beer-Lambert law is obeyed in the range 0.0 - 0.024 mM of fluoride (0.0 - 1.0 mg·L-1). The molar absorptivity at 502 nm is 6.45 × 103 L·mol-1·cm-1. Fluoride concentration higher than 1.0 mg·L-1 can be measured after proper dilution. The sensitivity, detection limit, quantitation limit, and the percentage recovery of 0.75 mg·L-1 fluoride for the method were found to be 0.357 μg·ml-1., 0.07 mg·L-1, 0.2 mg·L-1, and 101.1 respectively. 展开更多
关键词 FLUORIDE GROUNDWATER spectrophotometric Method Aluminium Resorcin BLUE COMPLEX
下载PDF
Application of Total Error Strategy in Validation of Affordable and Accessible UV-Visible Spectrophotometric Methods for Quality Control of Poor Medicines 被引量:1
6
作者 Jérémie Kindenge Mbinze Jean Nsangu Mpasi +8 位作者 Elza Maghe Sébastien Kobo Rodrigue Mwanda Guy Mulumba Jacquie Bolavie Bolande Trésor Menanzambi Bayebila Maguy Borive Amani Philippe Hubert Roland Djang’eing’a Marini 《American Journal of Analytical Chemistry》 2015年第2期106-117,共12页
In the framework of fighting against the poor quality medicines sold in developing countries using classical analytical methods easily accessible in those countries, four UV-Visible spectrophotometric methods for one ... In the framework of fighting against the poor quality medicines sold in developing countries using classical analytical methods easily accessible in those countries, four UV-Visible spectrophotometric methods for one antimalarial (quinine) and two antibiotics (amoxicillin and metronidazole) have been developed and validated according to the total error strategy using the accuracy profiles as a decision tool. The dosing range was 2 - 10 μg/mL (for quinine sulfate in tablet), 4 - 12 μg/mL (for quinine bichlorhydrate in oral drop-metronidazole benzaote in oral suspension) and 15 - 35 μg/mL (for amoxicillin trihydrate in capsule). The validated methods were then applied in determining the content of some analogous medicines sold in the Democratic Republic of Congo. Thus, the proposed UV-Visible spectrophotometric methods are simple and suitable to quantify quinine, amoxicillin and metronidazole in different pharmaceutical forms. 展开更多
关键词 POOR Quality MEDICINES UV-VISIBLE spectrophotometric Methods QUININE Amoxicillin METRONIDAZOLE VALIDATION Total Error Accuracy Profiles
下载PDF
A Novel Spectrophotometric Method for Determination of Gabapentin in Pharmaceutical Formulations Using 2,5-Dihydroxybenzaldehyde 被引量:1
7
作者 Magda S. Saleh Ahmed K. Youssef +1 位作者 Elham Y. Hashem Doaa A. Abdel-Kader 《Computational Chemistry》 2014年第2期22-30,共9页
A highly simple, rapid, sensitive and selective method is developed for spectrophotometric determination of gabapentin in pure form as well as in pharmaceutical formulations. The method is based on the formation of a ... A highly simple, rapid, sensitive and selective method is developed for spectrophotometric determination of gabapentin in pure form as well as in pharmaceutical formulations. The method is based on the formation of a yellow Schiff base derived from the condensation of gabapentin drug (1-amino methyl) cyclo hexane acetic acid and 2,5-dihydroxybenzaldehyde (DHBA) exhibiting a maximum absorbance at 445 nm. The composition, molar absorptivity and effect of different excipient have been determined spectrophotometrically. Under optimized experimental conditions, Beer’s law is obeyed in the concentration range 2.57 - 37.25 μg/ml. The method is validated with respect to accuracy, precision, limit of detection and limit of quantification. The Sandell sensitivity, correlation coefficient and regression equation are calculated. The equilibrium constant and free energy change using Benesi-Hildebrand plot are also determined. The Schiff base derived from condensation of gabapentin with DHBA is also synthesized and characterized. The condensation reaction mechanism has been proposed. 展开更多
关键词 GABAPENTIN 2 5-Dihydroxybenzaldehyde PHARMACEUTICAL Formulations spectrophotometric ANALYSIS
下载PDF
New simple spectrophotometric method for determination of the binary mixtures(atorvastatin calcium and ezetimibe;candesartan cilexetil and hydrochlorothiazide) in tablets 被引量:1
8
作者 Tarek S.Belal Hoda G.Daabees +2 位作者 Magdi M.Abdel-Khalek Mohamed S.Mahrous Mona M.Khamis 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第2期118-126,共9页
A new simple spectrophotometric method was developed for the determination of binary mixtures without prior separation.The method is based on the generation of ratio spectra of compound X by using a standard spectrum ... A new simple spectrophotometric method was developed for the determination of binary mixtures without prior separation.The method is based on the generation of ratio spectra of compound X by using a standard spectrum of compound Y as a divisor.The peak to trough amplitudes between two selected wavelengths in the ratio spectra are proportional to concentration of X without interference from Y.The method was demonstrated by determination of two drug combinations.The first consists of the two antihyperlipidemics:atorvastatin calcium(ATV) and ezetimibe(EZE),and the second comprises the antihypertensives:candesartan cilexetil(CAN) and hydrochlorothiazide(HCT).For mixture 1,ATV was determined using 10 μg/mL EZE as the divisor to generate the ratio spectra,and the peak to trough amplitudes between 231 and 276 nm were plotted against ATV concentration.Similarly,by using 10 μg/mL ATV as divisor,the peak to trough amplitudes between 231 and 276 nm were found proportional to EZE concentration.Calibration curves were linear in the range 2.5-40 mg/mL for both drugs.For mixture 2,divisor concentration was 7.5 μg/mL for both drugs.CAN was determined using its peak to trough amplitudes at 251 and 277 nm,while HCT was estimated using the amplitudes between 251 and 276 nm.The measured amplitudes were linearly correlated to concentration in the ranges 2.5-50 and 1-30 μg/mL for CAN and HCT,respectively.The proposed spectrophotometric method was validated and successfully applied for the assay of both drug combinations in several laboratory-prepared mixtures and commercial tablets. 展开更多
关键词 spectrophotometric analysis Ratio spectra Atorvastatin Ezetimibe Candesartan Hydrochlorothiazide
下载PDF
β-CORRECTION SPECTROPHOTOMETRIC DETERMINATION OF ALUMINIUM, USING THE AL(Ⅲ)-PF-OP REACTION
9
作者 Hong Wen GAO Feng ZOU and Peng Fei ZHANG(Huaibei Environmental Monitoring Centre, Huaibei, Anhui Province, 235000Huaibei Beer-Manusfacturing Plant, Anhui Province,235000 Department of Chemistry,Huaibei Coal Teachers College, Anhui Province, 235000) 《Chinese Chemical Letters》 SCIE CAS CSCD 1994年第8期679-680,共2页
Aluminium has been determined by β-correction spectrophotometer with phenylfluorone (PF)and a non-ionic surfactant, emulsifying OP in PH 8 ammoniacal buffer solution. β-correction spectrophotometric method can elimi... Aluminium has been determined by β-correction spectrophotometer with phenylfluorone (PF)and a non-ionic surfactant, emulsifying OP in PH 8 ammoniacal buffer solution. β-correction spectrophotometric method can eliminate completely the effect of excess PF to increase the analytical sensitivity and decrease error. The results have Shown that Beer's law was obeyed over the concentration range 0-15μg Al (Ⅲ)/25ml and the relative standard deviation was less than 3.3%. 展开更多
关键词 OP spectrophotometric DETERMINATION OF THE USING CORRECTION ALUMINIUM PF
下载PDF
Solid-liquid Extraction Spectrophotometric Determination of Copper with 2,9-dimethyl-1,10-phenanthroline
10
作者 Peng, B Gao, JZ +3 位作者 Hu, GL Fan, HY Kang, JW Deng, HL 《Rare Metals》 SCIE EI CAS CSCD 2001年第4期213-216,共4页
Solid liquid extraction of copper ion (I) with 2, 9-dimethyl-1, 10-phenanthroline (neo-cuproine, DMP) into molten naphthalene followed by chloroform spectrophotometric determination has been studied experimentally. Th... Solid liquid extraction of copper ion (I) with 2, 9-dimethyl-1, 10-phenanthroline (neo-cuproine, DMP) into molten naphthalene followed by chloroform spectrophotometric determination has been studied experimentally. The ternary complex Cu(I)-DMP-ClO4 was extracted quantitatively into molten naphthalene in the range of pH from 5 to 6 at 85 C-. Absorbance was spectrophotometrically determined at 459 nm against the reagent blank after the solid naphthalene layer was anhydrously dissolved in chloroform. Beer's law is obeyed over a concentration range of 0.5-70 mug/mL. The molar absorptivity and Sandell's sensitivity are 1.0x10(4) L/(mol(.)cm) and 0.0099 mug(.)cm(2) respectively. In addition, the various conditions on determination and the interference of coexisted ions were discussed, and the method was applied to the determination of copper ion both in tea samples and cadmium sulfate reagents. The results are in good agreement with those obtained by ICP AES method. 展开更多
关键词 solid-liquid extraction spectrophotometric determination molten naphthalene COPPER DMP
下载PDF
Azeotropic mixture used for development and validation of Lornoxicam in bulk and its tablet dosage form by spectrophotometric method
11
作者 Prajesh Prajapati Vipul Vaghela +3 位作者 Deepak Rawtani Harshad Patel Jasmin Kubavat Dharmendra Baraiya 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第4期306-309,共4页
A novel,safe,economic and sensitive method of spectrophotometric estimation has been developed using Azeoptropic mixture (water∶methanol:60∶40,v/v) for the quantitative determination of Lornoxicam,a practically wate... A novel,safe,economic and sensitive method of spectrophotometric estimation has been developed using Azeoptropic mixture (water∶methanol:60∶40,v/v) for the quantitative determination of Lornoxicam,a practically water-insoluble drug.Hence,Lornoxicam stock solution was prepared in Azeoptropic mixture.Lornoxicam showed maximum absorbance at 383 nm.Beer's law was obeyed in the concentration range 4-24 μg/mL with regression coefficient of 0.999.The method was validated in terms of linearity (R2=0.999),precision (CV for intra-day and inter-day was 0.28 0.68 and 0.12-0.92,respectively),accuracy (98.03-100.59% w/w) and specificity.This method is simple,precise,accurate,sensitive and reproducible and can be used for the routine quality control testing of the marketed formulations. 展开更多
关键词 ANALGESIC Chlortenoxicam LORNOXICAM Oxicam spectrophotometric Azeotropic mixture
下载PDF
Spectrophotometric Simultaneous Determination of Zinc(II), Manganese(II) and Iron(II) in Pharmaceutical Preparations Using OSC-PLS
12
作者 Ali NIAZI zadeh YAZDANIPOUR +2 位作者 ohammad GOODARZI amidreza KAMKAR Ali RAFINEJAD 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第10期1347-1350,共4页
This work reports the spectrophotometric simultaneous determination of zinc(Ⅱ), manganese(Ⅱ) and iron(Ⅱ) in pharmaceutical preparation, using orthogonal signal correctionpartial least squares (OSC-PLS). All... This work reports the spectrophotometric simultaneous determination of zinc(Ⅱ), manganese(Ⅱ) and iron(Ⅱ) in pharmaceutical preparation, using orthogonal signal correctionpartial least squares (OSC-PLS). All the factors affecting on the sensitivity were optimized and the linear dynamic range for determination of these metals was found. The PLS modeling was used for the multivariate calibration of the spectrophotometric data. The OSC was used for preprocessing of data matrices and the prediction results of model. The experimental calibration matrix was designed by measuring the absorbance over the range 450-570 nm for 21 samples of 0.05-1.05, 0.10-1.10 and 0.05-1.05μg·mL^-1 of zinc(Ⅱ), manganese(Ⅱ) and iron(Ⅱ), respectively. The RMSEP for zinc(Ⅱ), manganese(Ⅱ) and iron(Ⅱ) using OSC-PLS were 0.0164, 0.0132, 0.0146, respectively. The proposed method was successfully applied the determination of zinc(Ⅱ), manganese(Ⅱ) and iron(Ⅱ) in pharmaceutical preparations. 展开更多
关键词 Zinc(Ⅱ) manganese(Ⅱ) iron(Ⅱ) spectrophotometric OSC-PLS PHARMACEUTICAL
下载PDF
SPECTROPHOTOMETRIC ANALYSIS OF MIXTURES OF TRACE METAL BY DOUBLE-SYSTEM AND MULTIVARIATE CALIRRATION
13
作者 Yong Nian NI Xin Ming YIN Department of Chemistry,Jiangxi University,Nanchang,33007 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第2期157-158,共2页
In this paper,a new method for simultaneous spectrophotometric analysis of multi- component with double-system was developed.The multivariate calibration method,principal component analysis-partial least squares(PCA-P... In this paper,a new method for simultaneous spectrophotometric analysis of multi- component with double-system was developed.The multivariate calibration method,principal component analysis-partial least squares(PCA-PLS),was described and applied to the processing of measurement data.A demonstration,simultaneous determination of cobalt,nickel,copper,zinc and iron with double-system(5-Br-PADAP and PAR as chromogenic chelate reagents,respectively) was given.The results showed that the method with douhle-system gave better precision than those with single system and MLR(in this paper,AKC method was selected)did not give satis- fied precision in any situation. 展开更多
关键词 PLS PCR spectrophotometric ANALYSIS OF MIXTURES OF TRACE METAL BY DOUBLE-SYSTEM AND MULTIVARIATE CALIRRATION APPI RSD
下载PDF
Spectrophotometric Determination of Trace Chromium(VI) in Mass Chromium(III)
14
作者 Zi Gang XU Xian Hong WEN Qing Zhou WU 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第7期635-636,共2页
The method for the sepration and determination of trace Cr(VI) exiting in mass Cr(III) has been researched. The method is highly sensitive and less interference, but is simple and useful for analysis trace Cr(VI).
关键词 spectrophotometric CR(VI) CR(III) diphenyl carbazide(DPC) 4-methyl-benzene sulfonic acid
下载PDF
Study on the Spectrophotometric Determination of Rare Earths with a New Chromogenic Reagent Dibromo-p-methyl-chlorosulfonazo(DBMCSA)
15
作者 Guo Zhen FANG Jiao PAN +1 位作者 Wei Liang AHOU Bu Lu XU(Deparment of Chemistry.East China Normal University3663 Zhongshan Road(N), Shanghai 200062) 《Chinese Chemical Letters》 SCIE CAS CSCD 1999年第10期851-854,共4页
A new method for the determination of cerium subgroup rare earths was studied and reported ill this paper. It was found that cerium subgroup rare earth elements react with DBMCSA in 0.6 mol/L hydrochloric acid medium ... A new method for the determination of cerium subgroup rare earths was studied and reported ill this paper. It was found that cerium subgroup rare earth elements react with DBMCSA in 0.6 mol/L hydrochloric acid medium to form stable blue complexes. The absorbances of equal amounts of cerium subgroup rare earths are close to each other at their maximum adsorptive wavelength (641 nm). Beer's law is obeyed for 0-20 mu g of I ars earths in 25 mi of solution. The method has been applied to the determination of the total amount of cerium subgroup rare earths in steel and cast iron samples with satisfactory results. 展开更多
关键词 spectrophotometric determination rare earths dibromo-p-methyl-chlorosulfonazo (DBMCSA)
下载PDF
SPECTROPHOTOMETRIC STUDY OF BIMETALLIC TERNARY COMPLEX OF LANTHANUM——COPPER WITH ALIZARIN FLUORINE BLUE
16
《Chemical Research in Chinese Universities》 SCIE CAS 1986年第1期65-75,共11页
The bimetallic ternary complex formation in the aqueous solution of La and Cu with alizarin fluorine blue (AFB) was studied by spectrophotometry.The ternary complex LaCu3(AFB)3 has maximum light absorption at 550nm.Th... The bimetallic ternary complex formation in the aqueous solution of La and Cu with alizarin fluorine blue (AFB) was studied by spectrophotometry.The ternary complex LaCu3(AFB)3 has maximum light absorption at 550nm.The colour reaction selectivity is fairly good and the method can be applied to the direct photometric determination of copper in lanthanum or some pure metals.A new mathematical approach to the treatment of spectrophotometric data for differentiation between mononuclear and polynuclear in solution is presented.The improvable fixed logarithm method is for complexes of the type MmBn(m=n) or MmBn(m=n).We report that La(Ⅲ) combines with AFB at pH 4.5 to form a single complex,withm=n=2,La2(AFB)2. 展开更多
关键词 AFB La spectrophotometric STUDY OF BIMETALLIC TERNARY COMPLEX OF LANTHANUM COPPER WITH ALIZARIN FLUORINE BLUE
下载PDF
Liquid waveguide capillary cell for the spectrophotometric determination of nanomolar iodate concentrations in marine waters
17
作者 Jianrong Lin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第3期103-108,共6页
A new spectrophotometric method based on a liquid waveguide capillary cell for an enhanced detection was developed to measure nanomolar iodate concentrations.This method has a detection limit and precision of 1-2 nmol... A new spectrophotometric method based on a liquid waveguide capillary cell for an enhanced detection was developed to measure nanomolar iodate concentrations.This method has a detection limit and precision of 1-2 nmol/L,which is equivalent to 10%that of conventional methods,a recovery of 97.7%-104.0%,and a working range of 10-120 nmol/L.Water samples were collected from three estuaries and one coastal ocean for testing,and the proposed technique detected as low as 11 nmol/L and 18 nmol/L iodate in these samples.This newly developed method is helpful in understanding the biogeochemical cycle of iodine in nature. 展开更多
关键词 IODATE liquid waveguide capillary cell spectrophotometric determination
下载PDF
STUDY AND APPLICATION OF SPECTROPHOTOMETRIC DETERMINATION OF MICRO AMOUNTS OF BISMUTH WITH MESO—TETRAKIS—(4—N—TRIMETHYL AMMONIUMPHENYL)PORPHINE
18
作者 Mei FANG Shou Kun HU (Department of Chemistry, Sichuan University, Chengdu 610064) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第10期789-792,共4页
A new highly sensitive spectrophotometric method has been developed for the determination of micro amounts of bismuth (Ⅲ), based on the formation of Bi (Ⅲ)—meso—tetrakis—(4—N—trimethylammonium phenyl) porphine ... A new highly sensitive spectrophotometric method has been developed for the determination of micro amounts of bismuth (Ⅲ), based on the formation of Bi (Ⅲ)—meso—tetrakis—(4—N—trimethylammonium phenyl) porphine [T (4TMAP) P] complex. In the presence of Cd (Ⅱ), Bi(Ⅲ) reacts almost instantaneously with T (4TMAP)P in a 0. 6 mol/l NaAc—HAC buffer (PH5.8) at room temperature. The composition of the complex is T(4TMAP)P: Bi=1:1. The absorbance complex obeys Beer's law over the Bi(Ⅲ) concentration range 0.1—1.4 μg/ml. The linear relative coefficient γ is 0.9998. The apparent molar absorptivity was 1.75×10~5 1. mol^(-1). cm^(-1) at 463nm. The relative standard deviation of the method is 1.50% for Bi(Ⅲ) 7ug/10ml (10 determinations). The interference of foreign ions has been examined. This simple and rapid method can be applied to the assay of Bi(Ⅲ) in some tablets directly. 展开更多
关键词 TETRAKIS TRIMETHYL AMMONIUMPHENYL)PORPHINE STUDY AND APPLICATION OF spectrophotometric DETERMINATION OF MICRO AMOUNTS OF BISMUTH WITH MESO BI
下载PDF
Quick and Simple Spectrophotometric Method of Identification of the Thermal State of Meat on the Basis of Composition and Content of Free Nucleotides
19
作者 Magomed Dibirasulaev Georgy Belozerov +1 位作者 Leonid Arkhipov Lidia Stoyanova 《Food and Nutrition Sciences》 2018年第5期572-583,共12页
At present, there is no method for identifying meat frozen in a thermal state acceptable for production control. The role of free nucleotides in the processes of refrigeration and storage of meat, affecting the struct... At present, there is no method for identifying meat frozen in a thermal state acceptable for production control. The role of free nucleotides in the processes of refrigeration and storage of meat, affecting the structural and mechanical properties of muscle tissue, the formation of taste and its biological value is known. In this article we compared methods for identifying the thermal state of meat based on the determination of the composition and content of free nucleotides by high-performance liquid chromatography (HPLC) and spectrophotometry [SF]. High-purity reference substances were used: free nucleotides—ATP, ADP, AMP, IMP and nucleosides-inosine and hypoxanthine. It has been experimentally established that the characteristic peaks of the absorption spectra for extracts of free nucleotides of meat frozen depended from thermal state of meat. The content of ATP is 21.8 times higher in meat frozen in a fresh state, and the amount of IMF is 12.3 times lower than in meat frozen after cooling. The results of studies of meat frozen using the HPLC method and the developed SF method show the adequacy of the data obtained by both methods. SF-method based on the determination of the optical density of the extracts of free nucleotides is recommended to justify the choice of technological process meat defrost modes. 展开更多
关键词 Thermal State of MEAT Free NUCLEOTIDES and NUCLEOSIDES HPLC and spectrophotometric Methods Defrost MODES
下载PDF
Rapid Estimation on the Sperm Concentration in Boar Semen by Spectrophotometric Method
20
作者 PENG Yi ZHANG Liang 《Animal Husbandry and Feed Science》 CAS 2012年第4期150-152,168,共4页
[ Objective] To establish the standardized spectrophotometric method to determine boar sperm concentration. [ Method ] The relation- ships between absorbance (A), transmittance (T) and sperm concentration (C) of... [ Objective] To establish the standardized spectrophotometric method to determine boar sperm concentration. [ Method ] The relation- ships between absorbance (A), transmittance (T) and sperm concentration (C) of different wavelengths (450, 550, 650 nm) were compared. [ Result] The maximum sperm concentration detected by absorbance presented an upward trend with the increase of the wavelengths, 202 mitliorVml (450 nm), 224 million/ml (550 nm) and 235 mUlion/ml (650 nm), respectively, but the stability of repeated measurement was decreased. With the increase of sperm dilution times, the stability of repeated measurement of transmittance was reduced, and when dilution times were more than 10 times (450 nm), 6 times (550 nm) and 4 times (650 nm), differences appeared between the observed values of repeated measurement. [ Con- clusion] Wavelength at 450 nm was found to be the most sensitive and reliable, and sperm concentration presented cubic functional regression rela- tionship or power functional regression relationship with absorbance or transmittance, respectively. The regression equation for the standard curve at 450 nm was C400 = 0.48A3 - 0.76A2 + 0.67A - 0.066 ( R = 0.951 ) and C400 = 1.657T -0.108. 8 ( R = 0.940). 展开更多
关键词 SWINE Sperm concentration spectrophotometric method
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部