Deep cryogenic treatment technology of electrodes is put forward to improve electrode life of resistance spot welding of aluminum alloy LF2. Deep cryogenic treatment makes electrode life for spot welding aluminum allo...Deep cryogenic treatment technology of electrodes is put forward to improve electrode life of resistance spot welding of aluminum alloy LF2. Deep cryogenic treatment makes electrode life for spot welding aluminum alloy improve. The specific resistivity of the deep cryogenic treatment electrodes is tested and experimental results show that specific resistivity is decreased sharply. The temperature field and the influence of deep cryogenic treatment on the electrode tip temperature during spot welding aluminium alloy is studied by numerical simulation method with the software ANSYS. The axisymmetric finite element model of mechanical, thermal and electrical coupled analysis of spot welding process is developed. The numerical simulation results show that the influence of deep cryogenic treatment on electrode tip temperature is very large.展开更多
The effects of deep cryogenic treatment on mechanical behavior of a Cu-Cr-Zr alloy for electrodes of spot welding were investigated employing Brinell-hardness testing unit, abrasion examination machine, electronic alm...The effects of deep cryogenic treatment on mechanical behavior of a Cu-Cr-Zr alloy for electrodes of spot welding were investigated employing Brinell-hardness testing unit, abrasion examination machine, electronic almighty testing machine and X-ray stress analyzer. Tensile fracture surfaces of the alloy were characterized by scanning electronic microscope (SEM) with energy dispersive X-ray spectroscopy (EDS). The results showed that, after deep cryogenic treatment, σb and σ0.2 increased 23 MPa and 21 MPa respectively, the wear rate of the alloy exhibited the trend of decrease with the decreasing temperature and increasing time of deep cryogenic treatment, and the surface residual stress of the alloy was partially eliminated by deep cryogenic treatment.展开更多
The microstructure and elements distribution of the deep cryogenic treatmentelectrodes and non-cryogenic treatment electrodes for spot welding hot dip galvanized steel areobserved by a scanning electrical microscope. ...The microstructure and elements distribution of the deep cryogenic treatmentelectrodes and non-cryogenic treatment electrodes for spot welding hot dip galvanized steel areobserved by a scanning electrical microscope. The grain sizes, the resistivity and the hardness ofthe electrodes before and after deep cryogenic treatment are measured by X-ray diffraction, the DCdouble arms bridge and the Brinell hardness testing unit respectively. The spot welding processperformance of hot dip galvanized steel plate is tested and the relationship between microstructureand physical properties of deep cryogenic treatment electrodes is analyzed. The experimental resultsshow that deep cryogenic treatment makes Cr, Zr in deep cryogenic treatment electrodes emanatedispersedly and makes the grain of deep cryogenic treatment electrodes smaller than non-cryogenictreatment ones so that the electrical conductivity and the thermal conductivity of deep cryogenictreatment electrodes are improved very much, which make spot welding process performance of the hotdip galvanized steel be improved.展开更多
Cr-Zr-Cu alloy electrodes for resistance spot welding of aluminium alloy are treated by deep cryogenic treatment processes. The Cr-Zr-Cu alloy electrodes are analyzed by transmission electron microscope( TEM ) , and...Cr-Zr-Cu alloy electrodes for resistance spot welding of aluminium alloy are treated by deep cryogenic treatment processes. The Cr-Zr-Cu alloy electrodes are analyzed by transmission electron microscope( TEM ) , and results show that the common dislocation in Cr-Zr-Cu alloy electrodes is changed into the dislocation loop, and twin crystal is found after deep cryogenic treatment. The parallel twin crystal band is observed by selected electron diffraction(SED) and the twin crystal plane is marked as ( 111 ). The Cr-Zr-Cu alloy electrode is studied by X-ray diffraction( XRD ) and results show that the intensity of diffraction peak is obviously changed after deep cryogenic treatment, and the grain rotates to preferred orientation. The Cr-Zr- Cu alloy electrode is studied by positron annihilation technique (PAT) and results indicate that the amount of vacancy defects is less than that of Cr-Zr-Cu alloy before deep cryogenic treatment. The main elements in Cr-Zr-Cu alloy are studied with X- ray photoelctron spectroscopy( XPS ) and the intensity of spectrum peak is increased after deep cryogenic treatment.展开更多
基金This project is supported by Natural Science Foundation of Shanxi Province,China(20051063)the Education Department Science and Technology Development Foundation of Shanxi Province,China(200262)Doctor Research Foundation of Taiyuan University of Science and Technology,Taiyuan,Shanxi Province,China(200271).
文摘Deep cryogenic treatment technology of electrodes is put forward to improve electrode life of resistance spot welding of aluminum alloy LF2. Deep cryogenic treatment makes electrode life for spot welding aluminum alloy improve. The specific resistivity of the deep cryogenic treatment electrodes is tested and experimental results show that specific resistivity is decreased sharply. The temperature field and the influence of deep cryogenic treatment on the electrode tip temperature during spot welding aluminium alloy is studied by numerical simulation method with the software ANSYS. The axisymmetric finite element model of mechanical, thermal and electrical coupled analysis of spot welding process is developed. The numerical simulation results show that the influence of deep cryogenic treatment on electrode tip temperature is very large.
基金[This work was financially supported by the National Natural Science Foundation of China (No. 50175080) and the Specialized Research Fund for the Doctoral Program of Higher Education of China (SRFDP: No. 20030056003).]
文摘The effects of deep cryogenic treatment on mechanical behavior of a Cu-Cr-Zr alloy for electrodes of spot welding were investigated employing Brinell-hardness testing unit, abrasion examination machine, electronic almighty testing machine and X-ray stress analyzer. Tensile fracture surfaces of the alloy were characterized by scanning electronic microscope (SEM) with energy dispersive X-ray spectroscopy (EDS). The results showed that, after deep cryogenic treatment, σb and σ0.2 increased 23 MPa and 21 MPa respectively, the wear rate of the alloy exhibited the trend of decrease with the decreasing temperature and increasing time of deep cryogenic treatment, and the surface residual stress of the alloy was partially eliminated by deep cryogenic treatment.
基金This projecti is supported by National Natural Science Foundation of China (No.50175080).
文摘The microstructure and elements distribution of the deep cryogenic treatmentelectrodes and non-cryogenic treatment electrodes for spot welding hot dip galvanized steel areobserved by a scanning electrical microscope. The grain sizes, the resistivity and the hardness ofthe electrodes before and after deep cryogenic treatment are measured by X-ray diffraction, the DCdouble arms bridge and the Brinell hardness testing unit respectively. The spot welding processperformance of hot dip galvanized steel plate is tested and the relationship between microstructureand physical properties of deep cryogenic treatment electrodes is analyzed. The experimental resultsshow that deep cryogenic treatment makes Cr, Zr in deep cryogenic treatment electrodes emanatedispersedly and makes the grain of deep cryogenic treatment electrodes smaller than non-cryogenictreatment ones so that the electrical conductivity and the thermal conductivity of deep cryogenictreatment electrodes are improved very much, which make spot welding process performance of the hotdip galvanized steel be improved.
基金This project is supported by Nature Science Foundation of Shanxi Province ( No. 2009011028-2) , Talent Star Special Foundation of Taiyuan (No. 09121013 ), College Students Innovation Foundation of Shanxi Province( No. UIT20090065 ).
文摘Cr-Zr-Cu alloy electrodes for resistance spot welding of aluminium alloy are treated by deep cryogenic treatment processes. The Cr-Zr-Cu alloy electrodes are analyzed by transmission electron microscope( TEM ) , and results show that the common dislocation in Cr-Zr-Cu alloy electrodes is changed into the dislocation loop, and twin crystal is found after deep cryogenic treatment. The parallel twin crystal band is observed by selected electron diffraction(SED) and the twin crystal plane is marked as ( 111 ). The Cr-Zr-Cu alloy electrode is studied by X-ray diffraction( XRD ) and results show that the intensity of diffraction peak is obviously changed after deep cryogenic treatment, and the grain rotates to preferred orientation. The Cr-Zr- Cu alloy electrode is studied by positron annihilation technique (PAT) and results indicate that the amount of vacancy defects is less than that of Cr-Zr-Cu alloy before deep cryogenic treatment. The main elements in Cr-Zr-Cu alloy are studied with X- ray photoelctron spectroscopy( XPS ) and the intensity of spectrum peak is increased after deep cryogenic treatment.