A multitracer-gas method was proposed to study the secondary air(SA)mixing along the bed height in a circulating fluidized bed(CFB)using carbon monoxide(CO),oxygen(O_(2)),and carbon dioxide(CO_(2))as tracer gases.Expe...A multitracer-gas method was proposed to study the secondary air(SA)mixing along the bed height in a circulating fluidized bed(CFB)using carbon monoxide(CO),oxygen(O_(2)),and carbon dioxide(CO_(2))as tracer gases.Experiments were carried out on a cold CFB test rig with a cross-section of 0.42 m×0.73 m and a height of 5.50 m.The effects of superficial velocity,SA ratio,bed inventory,and particle diameter on the SA mixing were investigated.The results indicate that there are some differences in the measurement results obtained using different tracer gases,wherein the deviation between CO and CO_(2) ranges from 42%to 66%and that between O_(2) and CO_(2) ranges from 45%to 71%in the lower part of the fluidized bed.However,these differences became less pronounced as the bed height increased.Besides,the high solid concentration and fine particle diameter in the CFB may weaken the difference.The measurement results of different tracer gases show the same trends under the variation of operating parameters.Increasing superficial velocity and SA ratio and decreasing particle diameter result in better mixing of the SA.The effect of bed inventory on SA mixing is not monotonic.展开更多
Circulating fluidized bed flue gas desulfurization(CFB-FGD) process has been widely applied in recent years. However, high cost caused by the use of high-quality slaked lime and difficult operation due to the complex ...Circulating fluidized bed flue gas desulfurization(CFB-FGD) process has been widely applied in recent years. However, high cost caused by the use of high-quality slaked lime and difficult operation due to the complex flow field are two issues which have received great attention. Accordingly, a laboratory-scale fluidized bed reactor was constructed to investigate the effects of physical properties and external conditions on desulfurization performance of slaked lime, and the conclusions were tried out in an industrial-scale CFB-FGD tower. After that, a numerical model of the tower was established based on computational particle fluid dynamics(CPFD) and two-film theory. After comparison and validation with actual operation data, the effects of operating parameters on gas-solid distribution and desulfurization characteristics were investigated. The results of experiments and industrial trials showed that the use of slaked lime with a calcium hydroxide content of approximately 80% and particle size greater than 40 μm could significantly reduce the cost of desulfurizer. Simulation results showed that the flow field in the desulfurization tower was skewed under the influence of circulating ash. We obtained optimal operating conditions of 7.5 kg·s^(-1)for the atomized water flow, 70 kg·s^(-1)for circulating ash flow, and 0.56 kg·s^(-1)for slaked lime flow, with desulfurization efficiency reaching 98.19% and the exit flue gas meeting the ultraclean emission and safety requirements. All parameters selected in the simulation were based on engineering examples and had certain application reference significance.展开更多
In this paper,using the computational fluid dynamics based on Euler Lagrange and the commercial software Barracuda VR,the gas-particle hydrodynamics and the erosion of particles on the inner wall and internal componen...In this paper,using the computational fluid dynamics based on Euler Lagrange and the commercial software Barracuda VR,the gas-particle hydrodynamics and the erosion of particles on the inner wall and internal components of the spouted bed in the integrated multi-jet swirling spout-fluidized bed(IMSSFB)are studied.Erosion experiments have obtained the characterization of particle erosion on internal components and verified the relevant numerical models.The results show that:the particle distribution within the IMSSFB is uneven due to the cyclonic effect of the axial swirl vane(ASV),resulting in particle erosion for the ASV being concentrated on one side;when the gas reaches the top,too high an erosion gas velocity leads to gas backflow.As the filling height increases,there is a tendency for the erosion position of the particles on the ASV to expand upwards.However,the effect of increasing gas velocity on the erosion position is insignificant.展开更多
The tests of flue gas desulfurization were carried out on a circulating fluidized bed reactor in which the flue gas had different velocities at different sections. The SO 2 removal efficiency could be as high as 80% ...The tests of flue gas desulfurization were carried out on a circulating fluidized bed reactor in which the flue gas had different velocities at different sections. The SO 2 removal efficiency could be as high as 80% when Ca/S molar ratio was 1 1 and a small amount of water was sprayed into the reactor by a two phase (gas liquid) system nozzle.展开更多
A three-dimensional Eulerian multiphase model, with closure law according to the kinetic theory of granular flow, was used to study the gas/solid flow behaviors in spout-fluid beds. The influences of the coefficient o...A three-dimensional Eulerian multiphase model, with closure law according to the kinetic theory of granular flow, was used to study the gas/solid flow behaviors in spout-fluid beds. The influences of the coefficient of restitution due to non-ideal particle collisions on the simulated results were tested. It is demonstrated that the simulated result is strongly affected by the coefficient of restitution. Comparison of simulations with experiments in a small spout-fluid bed showed that an appropriate coefficient of restitution of 0.93 was necessary to simulate the flow characteristics in an underdesigned large size of spout-fluid bed coal gasifier with diameter of lm and height of 6m. The internal jet and gas/solid flow patterns at different operating conditions were obtained. The simulations show that an optimal gas/solid flow pattern for coal gasification is found when the spouting gas flow rate is equal to the fluidizing gas flow rate and the total of them is two and a half times the minimum fluidizing gas flow rate. Besides, the radial distributions of particle velocity and gas velocity show similar tendencies; the radial distributions of particle phase pressure due to particle collisions and the particle pseudo-temperature corresponding to the macroscopic kinetic energy of the random particle motion also show similar tendencies. These indicate that both gas drag force and particle collisions dominate the movement of particles.展开更多
In the last several decades, circulating fluidized bed reactors have been studied in many aspects including hydrodynamics, heat and mass transfer and gas–solid two phase contacting. However, despite the abundance of ...In the last several decades, circulating fluidized bed reactors have been studied in many aspects including hydrodynamics, heat and mass transfer and gas–solid two phase contacting. However, despite the abundance of review papers on hydrodynamics, there is no summary paper on gas–solid contact efficiency to date, especially on high density circulating fluidized beds(CFBs). This paper gives an introduction to, and a review of the measurement of contact efficiency in circulating fluidized bed riser. Firstly, the popular testing method of contact efficiency including the method of heating transfer experiment and hot model reaction are discussed, then previous published papers are reviewed based on the discussed methods. Some key results of the experimental work are described and discussed. Gas–solid contact efficiency is affected by the operating conditions as well as the particle size distribution. The result of the contact efficiency shows that the CFB riser is far away from an ideal plug flow reactor due to the characteristics of hydrodynamics in the riser. Lacunae in the available literature have been delineated and recommendations have been made for further work.展开更多
A novel process for synthesis gas production over Circulating Fluidized Bed (CFB) using oxygen storage materials as oxygen carder was reported. First, oxygen in the air was chemically fixed and converted to lattice ...A novel process for synthesis gas production over Circulating Fluidized Bed (CFB) using oxygen storage materials as oxygen carder was reported. First, oxygen in the air was chemically fixed and converted to lattice oxygen of oxygen storage materials over regenerator, and then methane was selectively oxidized to synthesis gas with lattice oxygen of oxygen storage materials over riser reactor. The results from simulation reaction of CFB by sequential redox reaction on a fixed bed reactor using lanthanum-based perovskite LaFeO3 and La0.8Sr0.2Fe0.9CO0.1O3 oxides prepared by sol-gel, suggested that the depleted oxygen species could be regenerated, and methane could be oxidized to synthesis gas by lattice oxygen with high selectivity. The partial oxidation of methane to synthesis gas over CFB using lattice oxygen of the oxygen storage materials instead of gaseous oxygen should be possibly applicable.展开更多
Short residence time of the sorbent in the gas stream and formation of a dense layer of reaction product surrounding its surface influence the sulfur removal efficiency. A practical means of improving the process perf...Short residence time of the sorbent in the gas stream and formation of a dense layer of reaction product surrounding its surface influence the sulfur removal efficiency. A practical means of improving the process performance is to employ fluidized bed reaction in replacement of entrained bed reaction on normally used in cool side desulfurizaiton. This paper describes cold modeling study of a circulating fluidized bed reactor. Several aspects of the problem are discussed: fluidization behavior of CaO, attrition of the sorbent and solids entrainment from the fluidized bed. Mechanisms and key controlling parameters are identified, and an integral model based on rate of attrition and mass balance is developed for predicting steady state mass flows and particle size distributions of the system. A process flow scheme is finally presented for conducting desulfurization tests in the second stage of the study.展开更多
Different two-equation k-ε models were used to simulate the gas flow field generated by a new type of circulating fluidized bed reactor with venturi gas distributor. The numerical results were compared with the exper...Different two-equation k-ε models were used to simulate the gas flow field generated by a new type of circulating fluidized bed reactor with venturi gas distributor. The numerical results were compared with the experimental data. It has been shown that the simulation results from the standard k-ε model have the best match with the experimental data. Based on this model, the gas flow field in the venturi diffuser and riser was analyzed by the concept of velocity nonuniformity and dead zone percentage. Both the nonuniformity of gas velocity and the dead zone percentage reach the maximum at the venturi outlet due to the effect of the vortex. At the same time, it provides a good platform for the further optimization of the inlet configuration of circulating fluidized bed reactor.展开更多
A full-cycle numerical simulation of a circulating fluidized bed(CFB)by the use of the computational particle fluid dynamics(CPFD)method has been developed.The effects of the presence or absence of the secondary air,d...A full-cycle numerical simulation of a circulating fluidized bed(CFB)by the use of the computational particle fluid dynamics(CPFD)method has been developed.The effects of the presence or absence of the secondary air,different secondary air positions,and different secondary air ratios on the gas–solid flow characteristics were explored.The results show that the presence of the secondary air makes a core-annular structure of the velocity distribution of particles in the fluidized bed,which enhances the uniformity of particles’distribution and the stability of fluidization.The position and the ratio of the secondary air have a significant impact on the particle distribution,particle flow rate,and gas flow rate in the fluidized bed.When the secondary air position and ratio are optimal,the particles,particle flow rate,and air flow rate in the CFB are evenly distributed,the gas–solid flow state is good,and the CFB can operate stably.展开更多
The oxidizing highly reactive absorbent was prepared from fly ash,industry lime,and an oxidizing additive M.Experiments of simultaneous desulfurization and denitrification were carried out in a flue gas circulating fl...The oxidizing highly reactive absorbent was prepared from fly ash,industry lime,and an oxidizing additive M.Experiments of simultaneous desulfurization and denitrification were carried out in a flue gas circulating fluidized bed(CFB).The effects of influencing factors and calcium availability were also investigated on the removal efficiencies of desulfurization and denitrification.Removal efficiencies of 95.5%for SO2 and 64.8%for NO were obtained respectively under the optimal experimental conditions. The component of the spent absorbent was analyzed with chemical analysis methods.The results in- dicated that more nitrogen species appeared in the spent absorbent except sulfur species.A scanning electron microscope(SEM)and an accessory X-ray energy spectrometer were used to observe micro-properties of the samples,including fly ash,oxidizing highly reactive absorbent and spent absorbent.The simultaneous removal mechanism of SO2 and NO based on this absorbent was pro- posed according to the experimental results.展开更多
An experimental study has been performed systematically on flue gas desulphurization by using circulating fluidized bed. The relationship, between desulphurization efficiency and the parameters of thermodynamics and c...An experimental study has been performed systematically on flue gas desulphurization by using circulating fluidized bed. The relationship, between desulphurization efficiency and the parameters of thermodynamics and chemistry, was investigated basically. It is shown that the bed temperature and the vapor partial pressure in the bed are the important parameters that influence the desulphurization efficiency. The closer the bed temperature to the dew point and the higher the vapor partial pressure, the higher is the desulphurization efficiency. With increasing of Ca/S. the desulphurization efficiency ascends. Comparing with different operating methods, the optimum method has been found.展开更多
To better understand the hydrodynamic behavior of an internally circulating fluidized bed, solids holdup in the down-comer (Eso), solids circulation rate (Gs) and gas bypassing fraction (from down-comer to riser ...To better understand the hydrodynamic behavior of an internally circulating fluidized bed, solids holdup in the down-comer (Eso), solids circulation rate (Gs) and gas bypassing fraction (from down-comer to riser y^R, and from riser to down-comer yRD) were experimentally studied. The effects of gas velocities in the riser and in the down-comer (UR and UD), orifice diameter in the draft tube (dor), and draft tube height (HR) were investigated. Experimental results showed that increase of gas velocities led to increase in Gs and yDR, and slight decrease in yeD. Larger orifice diameter on the draft tube led to higher 8sD, Gs and yDR, but had insignificant influence on YRD. with increasing draft tube height, both Gs and YDR first increased and then decreased, while yRD first decreased and then increased. Proposed correlations for predicting the hydrodynamic parameters agreed reasonably well with experimental values.展开更多
An "Oxygen-enriched" highly reactive absor- bent was prepared by mixing fly ash, lime and a small quantity of KMnO4 for simultaneous desulfiarization and denitrification. Removal of SO2 and NO simultaneously was car...An "Oxygen-enriched" highly reactive absor- bent was prepared by mixing fly ash, lime and a small quantity of KMnO4 for simultaneous desulfiarization and denitrification. Removal of SO2 and NO simultaneously was carried out using this absorbent in a flue gas circulating fluidized bed (CFB). The highest simultaneous removal efficiency, 94.5% of SO2 and 64.2% of NO, was achieved under the optimal experiment conditions. Scanning Electron Microscope (SEM) and Accessory X-ray Energy Spectrometer (EDX) were used to observe the surface characteristics of fly ash, lime, "Oxygen-enriched" highly reactive absorbent and the spent absorbent. An ion chromatograph (IC) and chemical analysis methods were used to determine the contents of sulfate, sulfite, nitrate and nitrite in the spent absorbents, the results showed that sulfate and nitrite were the main products for desulfurization and denitrification respectively. The mechanism of removing SO2 and NO simultaneously was proposed based on the analysis results of SEM, EDX, IC and the chemical analysis methods.展开更多
To investigate the non-uniform distribution of different gases passing through the parallel cyclones,experiments were conducted on a circulating fluidized bed(CFB)equipped with six asymmetrical cyclones.A multi-tracer...To investigate the non-uniform distribution of different gases passing through the parallel cyclones,experiments were conducted on a circulating fluidized bed(CFB)equipped with six asymmetrical cyclones.A multi-tracer gas method was used,with CO,O_(2),and CO_(2) chosen to represent gases with different properties in the flue gas at the inlets of the cyclones.The uniformity of multi-gas distribution was evaluated by measuring the concentration deviations of each tracer gas passing through individual cyclones.The results indicate that the concentrations of multi-tracer gases are higher in the middle cyclone among the three,which are located on the tracer gas injection side during the test of single-side secondary air(SA)tracing.The maximum concentration deviation of tracer gases is for CO_(2),while the minimum is for CO.At the three cyclone inlets on the opposite side,the tracer gas with higher density exhibits a more uniform distribution,and the gas uniformity decreases as the density decreases.The effects of superficial velocity,SA ratio,bed inventory,and tracer gas injection region on the uniformity of gas distribution were studied.The results show that superficial velocity and SA ratio primarily affect the uniformity of higher density gases,while bed inventory has a greater influence on lower density gases.The gas distributions are most non-uniform,especially for CO_(2),when the tracer gas injection region is near the rear wall closer to the induced draft fan during the test of regional SA tracing.展开更多
基金the Key Project of the National Research Program of China(2020YFB0606201)。
文摘A multitracer-gas method was proposed to study the secondary air(SA)mixing along the bed height in a circulating fluidized bed(CFB)using carbon monoxide(CO),oxygen(O_(2)),and carbon dioxide(CO_(2))as tracer gases.Experiments were carried out on a cold CFB test rig with a cross-section of 0.42 m×0.73 m and a height of 5.50 m.The effects of superficial velocity,SA ratio,bed inventory,and particle diameter on the SA mixing were investigated.The results indicate that there are some differences in the measurement results obtained using different tracer gases,wherein the deviation between CO and CO_(2) ranges from 42%to 66%and that between O_(2) and CO_(2) ranges from 45%to 71%in the lower part of the fluidized bed.However,these differences became less pronounced as the bed height increased.Besides,the high solid concentration and fine particle diameter in the CFB may weaken the difference.The measurement results of different tracer gases show the same trends under the variation of operating parameters.Increasing superficial velocity and SA ratio and decreasing particle diameter result in better mixing of the SA.The effect of bed inventory on SA mixing is not monotonic.
基金supported by National Natural Science Foundation of China(52336005 and 52106133).
文摘Circulating fluidized bed flue gas desulfurization(CFB-FGD) process has been widely applied in recent years. However, high cost caused by the use of high-quality slaked lime and difficult operation due to the complex flow field are two issues which have received great attention. Accordingly, a laboratory-scale fluidized bed reactor was constructed to investigate the effects of physical properties and external conditions on desulfurization performance of slaked lime, and the conclusions were tried out in an industrial-scale CFB-FGD tower. After that, a numerical model of the tower was established based on computational particle fluid dynamics(CPFD) and two-film theory. After comparison and validation with actual operation data, the effects of operating parameters on gas-solid distribution and desulfurization characteristics were investigated. The results of experiments and industrial trials showed that the use of slaked lime with a calcium hydroxide content of approximately 80% and particle size greater than 40 μm could significantly reduce the cost of desulfurizer. Simulation results showed that the flow field in the desulfurization tower was skewed under the influence of circulating ash. We obtained optimal operating conditions of 7.5 kg·s^(-1)for the atomized water flow, 70 kg·s^(-1)for circulating ash flow, and 0.56 kg·s^(-1)for slaked lime flow, with desulfurization efficiency reaching 98.19% and the exit flue gas meeting the ultraclean emission and safety requirements. All parameters selected in the simulation were based on engineering examples and had certain application reference significance.
基金supported by the National Natural Science Foundation of China(22178286)Shaanxi Qin Chuangyuan“scientist and engineer”team construction project(2022KXJ-041)。
文摘In this paper,using the computational fluid dynamics based on Euler Lagrange and the commercial software Barracuda VR,the gas-particle hydrodynamics and the erosion of particles on the inner wall and internal components of the spouted bed in the integrated multi-jet swirling spout-fluidized bed(IMSSFB)are studied.Erosion experiments have obtained the characterization of particle erosion on internal components and verified the relevant numerical models.The results show that:the particle distribution within the IMSSFB is uneven due to the cyclonic effect of the axial swirl vane(ASV),resulting in particle erosion for the ASV being concentrated on one side;when the gas reaches the top,too high an erosion gas velocity leads to gas backflow.As the filling height increases,there is a tendency for the erosion position of the particles on the ASV to expand upwards.However,the effect of increasing gas velocity on the erosion position is insignificant.
文摘The tests of flue gas desulfurization were carried out on a circulating fluidized bed reactor in which the flue gas had different velocities at different sections. The SO 2 removal efficiency could be as high as 80% when Ca/S molar ratio was 1 1 and a small amount of water was sprayed into the reactor by a two phase (gas liquid) system nozzle.
基金Supported by the National Key Program of Basic Research in China (No.2004CB217702, No.2005CB221202, No.2006CB20030201) and the National Natural Science Foundation of China (No.20590367, No.50676021, No.50606006).
文摘A three-dimensional Eulerian multiphase model, with closure law according to the kinetic theory of granular flow, was used to study the gas/solid flow behaviors in spout-fluid beds. The influences of the coefficient of restitution due to non-ideal particle collisions on the simulated results were tested. It is demonstrated that the simulated result is strongly affected by the coefficient of restitution. Comparison of simulations with experiments in a small spout-fluid bed showed that an appropriate coefficient of restitution of 0.93 was necessary to simulate the flow characteristics in an underdesigned large size of spout-fluid bed coal gasifier with diameter of lm and height of 6m. The internal jet and gas/solid flow patterns at different operating conditions were obtained. The simulations show that an optimal gas/solid flow pattern for coal gasification is found when the spouting gas flow rate is equal to the fluidizing gas flow rate and the total of them is two and a half times the minimum fluidizing gas flow rate. Besides, the radial distributions of particle velocity and gas velocity show similar tendencies; the radial distributions of particle phase pressure due to particle collisions and the particle pseudo-temperature corresponding to the macroscopic kinetic energy of the random particle motion also show similar tendencies. These indicate that both gas drag force and particle collisions dominate the movement of particles.
基金Supported by the Scientific Research Funds from China University of Petroleum(Beijing)(No.2462014YJRC018)partially supported by the National Natural Science Foundation of China(No.21506253 and No.91534204)
文摘In the last several decades, circulating fluidized bed reactors have been studied in many aspects including hydrodynamics, heat and mass transfer and gas–solid two phase contacting. However, despite the abundance of review papers on hydrodynamics, there is no summary paper on gas–solid contact efficiency to date, especially on high density circulating fluidized beds(CFBs). This paper gives an introduction to, and a review of the measurement of contact efficiency in circulating fluidized bed riser. Firstly, the popular testing method of contact efficiency including the method of heating transfer experiment and hot model reaction are discussed, then previous published papers are reviewed based on the discussed methods. Some key results of the experimental work are described and discussed. Gas–solid contact efficiency is affected by the operating conditions as well as the particle size distribution. The result of the contact efficiency shows that the CFB riser is far away from an ideal plug flow reactor due to the characteristics of hydrodynamics in the riser. Lacunae in the available literature have been delineated and recommendations have been made for further work.
基金Project supported by the National Natural Science Foundation of China (20306016, 20322201)
文摘A novel process for synthesis gas production over Circulating Fluidized Bed (CFB) using oxygen storage materials as oxygen carder was reported. First, oxygen in the air was chemically fixed and converted to lattice oxygen of oxygen storage materials over regenerator, and then methane was selectively oxidized to synthesis gas with lattice oxygen of oxygen storage materials over riser reactor. The results from simulation reaction of CFB by sequential redox reaction on a fixed bed reactor using lanthanum-based perovskite LaFeO3 and La0.8Sr0.2Fe0.9CO0.1O3 oxides prepared by sol-gel, suggested that the depleted oxygen species could be regenerated, and methane could be oxidized to synthesis gas by lattice oxygen with high selectivity. The partial oxidation of methane to synthesis gas over CFB using lattice oxygen of the oxygen storage materials instead of gaseous oxygen should be possibly applicable.
文摘Short residence time of the sorbent in the gas stream and formation of a dense layer of reaction product surrounding its surface influence the sulfur removal efficiency. A practical means of improving the process performance is to employ fluidized bed reaction in replacement of entrained bed reaction on normally used in cool side desulfurizaiton. This paper describes cold modeling study of a circulating fluidized bed reactor. Several aspects of the problem are discussed: fluidization behavior of CaO, attrition of the sorbent and solids entrainment from the fluidized bed. Mechanisms and key controlling parameters are identified, and an integral model based on rate of attrition and mass balance is developed for predicting steady state mass flows and particle size distributions of the system. A process flow scheme is finally presented for conducting desulfurization tests in the second stage of the study.
文摘Different two-equation k-ε models were used to simulate the gas flow field generated by a new type of circulating fluidized bed reactor with venturi gas distributor. The numerical results were compared with the experimental data. It has been shown that the simulation results from the standard k-ε model have the best match with the experimental data. Based on this model, the gas flow field in the venturi diffuser and riser was analyzed by the concept of velocity nonuniformity and dead zone percentage. Both the nonuniformity of gas velocity and the dead zone percentage reach the maximum at the venturi outlet due to the effect of the vortex. At the same time, it provides a good platform for the further optimization of the inlet configuration of circulating fluidized bed reactor.
基金the National Key Research and Development Program of China(grant No.2022YFC2904401)Guangxi Science and Technology Major Project(grant No.GuiKe AA23023033).
文摘A full-cycle numerical simulation of a circulating fluidized bed(CFB)by the use of the computational particle fluid dynamics(CPFD)method has been developed.The effects of the presence or absence of the secondary air,different secondary air positions,and different secondary air ratios on the gas–solid flow characteristics were explored.The results show that the presence of the secondary air makes a core-annular structure of the velocity distribution of particles in the fluidized bed,which enhances the uniformity of particles’distribution and the stability of fluidization.The position and the ratio of the secondary air have a significant impact on the particle distribution,particle flow rate,and gas flow rate in the fluidized bed.When the secondary air position and ratio are optimal,the particles,particle flow rate,and air flow rate in the CFB are evenly distributed,the gas–solid flow state is good,and the CFB can operate stably.
基金the Significant Pre-research Foundation of North China Electric PowerUniversity(D03-035)
文摘The oxidizing highly reactive absorbent was prepared from fly ash,industry lime,and an oxidizing additive M.Experiments of simultaneous desulfurization and denitrification were carried out in a flue gas circulating fluidized bed(CFB).The effects of influencing factors and calcium availability were also investigated on the removal efficiencies of desulfurization and denitrification.Removal efficiencies of 95.5%for SO2 and 64.8%for NO were obtained respectively under the optimal experimental conditions. The component of the spent absorbent was analyzed with chemical analysis methods.The results in- dicated that more nitrogen species appeared in the spent absorbent except sulfur species.A scanning electron microscope(SEM)and an accessory X-ray energy spectrometer were used to observe micro-properties of the samples,including fly ash,oxidizing highly reactive absorbent and spent absorbent.The simultaneous removal mechanism of SO2 and NO based on this absorbent was pro- posed according to the experimental results.
文摘An experimental study has been performed systematically on flue gas desulphurization by using circulating fluidized bed. The relationship, between desulphurization efficiency and the parameters of thermodynamics and chemistry, was investigated basically. It is shown that the bed temperature and the vapor partial pressure in the bed are the important parameters that influence the desulphurization efficiency. The closer the bed temperature to the dew point and the higher the vapor partial pressure, the higher is the desulphurization efficiency. With increasing of Ca/S. the desulphurization efficiency ascends. Comparing with different operating methods, the optimum method has been found.
基金the financial support by the Beijing New Star Project on Science&Technology of China under grant no.2009B35
文摘To better understand the hydrodynamic behavior of an internally circulating fluidized bed, solids holdup in the down-comer (Eso), solids circulation rate (Gs) and gas bypassing fraction (from down-comer to riser y^R, and from riser to down-comer yRD) were experimentally studied. The effects of gas velocities in the riser and in the down-comer (UR and UD), orifice diameter in the draft tube (dor), and draft tube height (HR) were investigated. Experimental results showed that increase of gas velocities led to increase in Gs and yDR, and slight decrease in yeD. Larger orifice diameter on the draft tube led to higher 8sD, Gs and yDR, but had insignificant influence on YRD. with increasing draft tube height, both Gs and YDR first increased and then decreased, while yRD first decreased and then increased. Proposed correlations for predicting the hydrodynamic parameters agreed reasonably well with experimental values.
文摘An "Oxygen-enriched" highly reactive absor- bent was prepared by mixing fly ash, lime and a small quantity of KMnO4 for simultaneous desulfiarization and denitrification. Removal of SO2 and NO simultaneously was carried out using this absorbent in a flue gas circulating fluidized bed (CFB). The highest simultaneous removal efficiency, 94.5% of SO2 and 64.2% of NO, was achieved under the optimal experiment conditions. Scanning Electron Microscope (SEM) and Accessory X-ray Energy Spectrometer (EDX) were used to observe the surface characteristics of fly ash, lime, "Oxygen-enriched" highly reactive absorbent and the spent absorbent. An ion chromatograph (IC) and chemical analysis methods were used to determine the contents of sulfate, sulfite, nitrate and nitrite in the spent absorbents, the results showed that sulfate and nitrite were the main products for desulfurization and denitrification respectively. The mechanism of removing SO2 and NO simultaneously was proposed based on the analysis results of SEM, EDX, IC and the chemical analysis methods.
基金financed by the Key Project of the National Research Program of China(grant No.2020YFB0606201).
文摘To investigate the non-uniform distribution of different gases passing through the parallel cyclones,experiments were conducted on a circulating fluidized bed(CFB)equipped with six asymmetrical cyclones.A multi-tracer gas method was used,with CO,O_(2),and CO_(2) chosen to represent gases with different properties in the flue gas at the inlets of the cyclones.The uniformity of multi-gas distribution was evaluated by measuring the concentration deviations of each tracer gas passing through individual cyclones.The results indicate that the concentrations of multi-tracer gases are higher in the middle cyclone among the three,which are located on the tracer gas injection side during the test of single-side secondary air(SA)tracing.The maximum concentration deviation of tracer gases is for CO_(2),while the minimum is for CO.At the three cyclone inlets on the opposite side,the tracer gas with higher density exhibits a more uniform distribution,and the gas uniformity decreases as the density decreases.The effects of superficial velocity,SA ratio,bed inventory,and tracer gas injection region on the uniformity of gas distribution were studied.The results show that superficial velocity and SA ratio primarily affect the uniformity of higher density gases,while bed inventory has a greater influence on lower density gases.The gas distributions are most non-uniform,especially for CO_(2),when the tracer gas injection region is near the rear wall closer to the induced draft fan during the test of regional SA tracing.