期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Obtaining 2D Soil Resistance Profiles from the Integration of Electrical Resistivity Data and Standard Penetration Test (SPT) and Light Dynamic Penetrometer (DPL) Resistance Tests—Applications in Mass Movements Studies
1
作者 Cassiano Antonio Bortolozo Tatiana Sussel Gonçalves Mendes +10 位作者 Mariana Ferreira Benessiuti Motta Silvio Jorge Coelho Simões Tristan Pryer Daniel Metodiev Marcio Roberto Magalhães de Andrade Maiconn Vinicius de Moraes Danielle Silva de Paula Nélio José Bastos Luana Albertani Pampuch Rodolfo Moreda Mendes Marcio Augusto Ernesto de Moraes 《International Journal of Geosciences》 2023年第9期840-854,共15页
In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occ... In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occurrences. The multifaceted nature of these influences makes the surveillance of mass movements a highly intricate task, requiring an understanding of numerous interdependent variables. Recent years have seen an emergence in scholarly research aimed at integrating geophysical and geotechnical methodologies. The conjoint examination of geophysical and geotechnical data offers an enhanced perspective into subsurface structures. Within this work, a methodology is proposed for the synchronous analysis of electrical resistivity geophysical data and geotechnical data, specifically those extracted from the Light Dynamic Penetrometer (DPL) and Standard Penetration Test (SPT). This study involved a linear fitting process to correlate resistivity with N10/SPT N-values from DPL/SPT soundings, culminating in a 2D profile of N10/SPT N-values predicated on electrical profiles. The findings of this research furnish invaluable insights into slope stability by allowing for a two-dimensional representation of penetration resistance properties. Through the synthesis of geophysical and geotechnical data, this project aims to augment the comprehension of subsurface conditions, with potential implications for refining landslide risk evaluations. This endeavor offers insight into the formulation of more effective and precise slope management protocols and disaster prevention strategies. 展开更多
关键词 GEOPHYSICS Geotechnical Data Electrical Resistivity Method standard penetration test (SPT) Light Dynamic Penetrometer (DPL) Mass Movements
下载PDF
Comparison of Vs and SPT Soil Liquefaction Assessments of NCEER: Including Hypothesis Testing
2
作者 Min-Hao Wu Jui-Pin Wang Chih-Kun Liao 《International Journal of Geosciences》 2023年第11期1085-1099,共15页
Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of ... Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of soil liquefaction studies were conducted and reported, including the liquefaction potential assessment methods utilizing the shear wave velocity (V<sub>s</sub>) or SPT-N profiles (SPT: standard penetration test). This study used the V<sub>s</sub> and SPT methods recommended by the National Center for Earthquake Engineering Research (NCEER) to examine which is more conservative according to the assessment results on 41 liquefiable soil layers at sites in two major cities in Taiwan. Statistical hypothesis testing was used to make the analysis more quantitative and objective. Based on three sets of hypothesis tests, it shows that the hypothesis—the SPT method is more conservative than the V<sub>s</sub> method—was not rejected on a 5% level of significance. 展开更多
关键词 Soil Liquefaction standard penetration test Shear Wave Velocity Hypothesis testing
下载PDF
Proposals of SPT-CPT and DPL-CPT correlations for sandy soils in Brazil 被引量:1
3
作者 Mirella Dalvi dos Santos Kátia Vanessa Bicalho 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2017年第6期1152-1158,共7页
Field tests in geotechnical engineering are fundamental for identification of the underground conditions.The standard penetration test(SPT) is the most commonly used geotechnical approach. There has been an increase b... Field tests in geotechnical engineering are fundamental for identification of the underground conditions.The standard penetration test(SPT) is the most commonly used geotechnical approach. There has been an increase both in the use and application of the in situ tests: cone penetration test(CPT) and dynamic probing(DP). Several empirical SPT-CPT and dynamic probing light(DPL)-CPT correlations for sandy soils have been discussed in the literature. New SPT-CPT and DPL-CPT correlations for the sandy soils of the city of Vitoria, in the southeast of Brazil, are suggested in this paper. Statistical analyses to evaluate the quality of the data used are performed, and the suggested correlations are validated with several previous published datasets. The paper also provides some insights into SPT-CPT correlations and soil characteristics(i.e. the mean particle size and the fines fraction of the soil). 展开更多
关键词 standard penetration test(SPT) Cone penetration test(CPT) Dynamic probing light(DPL) CORRELATIONS SANDS Statistical evaluations
下载PDF
Use of GIS Based Maps for Preliminary Assessment of Subsoil of Guwahati City 被引量:1
4
作者 Binu Sharma Shaffi Kamal Rahman 《Journal of Geoscience and Environment Protection》 2016年第5期106-116,共11页
Guwahati, the major city in the North Eastern region of India is growing rapidly in every aspect with major infrastructures like sports complex, educational institutions, hospitals, flyovers, multiplex halls, etc. Kno... Guwahati, the major city in the North Eastern region of India is growing rapidly in every aspect with major infrastructures like sports complex, educational institutions, hospitals, flyovers, multiplex halls, etc. Knowledge of the subsurface soil condition is necessary to ensure the structural safety and serviceability of the above mentioned structures before any construction. Therefore, contour maps of Standard penetration test N value, ground water table and shear wave velocity map using Geographical Information System (GIS) platform will be of great help to the foundation designers at the initial stage for site selection and preliminary foundation design under static and seismic condition. Contour maps of Standard penetration test N value at different depth and average contour map of N value of Guwahati city have been prepared. Standard penetration Test N values and depth of water table were taken from a data base of 200 boreholes up to 30 meter depth to prepare N value contour map of Guwahati city. A regression equation between shear wave velocity V<sub>s</sub> and Standard penetration test N value based on twenty seven previous similar correlations was also developed. This regression equation was used to determine shear wave velocity of Guwahati city. The average shear wave velocities for 30 m depth for all locations had been determined and used to generate map on (GIS) platform. Other subsurface geotechnical information of Guwahati city like soil classification and depth to water level from ground surface is also presented in the form of GIS based maps in order to form a data base. 展开更多
关键词 standard penetration test Shear Wave Velocity Contour Map GIS Based Maps Subsurface Investigation
下载PDF
Bearing Capacity Analysis of Shallow Foundations Supported on an Artificial Fill(Substation at Kashari,Tirana)
5
作者 Neritan Shkodrani Guxim Rrudhani Anxhela Shaha 《Journal of Civil Engineering and Architecture》 2022年第10期479-487,共9页
The paper presents conclusions related to the design of shallow foundations,at the site where the Substation at Kashari,in Tirana is foreseen to be constructed.The project includes buildings with small to medium struc... The paper presents conclusions related to the design of shallow foundations,at the site where the Substation at Kashari,in Tirana is foreseen to be constructed.The project includes buildings with small to medium structures with 1-3 stories.The geological survey works include 6 boreholes of a depth 20.0 m,90 SPT(Standard Penetration Tests)tests,and laboratory works include 13 direct shear tests,27 unconfined and compressive strength tests,7 CU(consolidated undrained)tests and 9 UU(unconsolidated undrained)tests,etc.The foundation design must fulfill both,bearing and settlement criteria,but in this case the settlements of foundations are not possible to be calculated,since the laboratory works do not include any consolidation test.So,the local bearing capacity is expected to control the design in terms of bearing capacity and settlements.The local bearing capacity of shallow square foundations is evaluated by using Terzaghi’s formula,based on reduced shear strength parameters of soils below the bottom of foundations.The results are compared with the bearing capacity values calculated by using Burland and Burbdige(1984)method,based on the data of SPT tests.This method is used for checking the settlement(serviceability)criterion in the foundation design,when the direct settlement calculation is missing.The paper presents some conclusions related to local bearing capacity foundation-based design. 展开更多
关键词 Bearing capacity ultimate/allowable bearing capacity local bearing capacity bore hole standard penetration test
下载PDF
In situ-based assessment of soil liquefaction potential-Case study of an earth dam in Tunisia 被引量:1
6
作者 Ikram GUETTAYA Mohamed Ridha EL OUNI 《Frontiers of Structural and Civil Engineering》 CSCD 2014年第4期456-461,共6页
The present paper examines the evaluation of liquefaction potential of an earth dam foundation in Tunisia. The assessment of soil liquefaction was made using deterministic and probabilistic simplified procedures devel... The present paper examines the evaluation of liquefaction potential of an earth dam foundation in Tunisia. The assessment of soil liquefaction was made using deterministic and probabilistic simplified procedures developed from several case histories. The data collected from the field investigation performed before and after the vibrocompaction are analyzed and the results are reported. The obtained results show that after vibrocompaction, a significant improvement of the soil resistance reduces the liquefaction potential of the sandy foundation. Indeed, in the untreated layers, the factor of safety FS drops below 1 which means that the soil is susceptible for liquefaction. However, in the compacted horizons, the values of FS exceed the unit which justifies the absence of liquefaction hazard of the foundation. 展开更多
关键词 LIQUEFACTION cone penetration test (CPT) standard penetration test (SPT) vibrcompaction SAND
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部