期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Clinical Observation of Self-made Four-step Tendon Regulating Manipulation in the Treatment of 30 Cases of Thumb Stenotic Tenosynovitis
1
作者 Yu YANG Kaiwei ZHANG Tao REN 《Medicinal Plant》 CAS 2023年第4期80-83,共4页
[Objectives] To observe the effectiveness of four-step tendon manipulation in the treatment of thumb stenotic tenosynovitis, under the guidance of "tendon first" theory. [Methods] 30 patients with stenotic t... [Objectives] To observe the effectiveness of four-step tendon manipulation in the treatment of thumb stenotic tenosynovitis, under the guidance of "tendon first" theory. [Methods] 30 patients with stenotic tenosynovitis of thumb were treated with four-step tendon manipulation and traditional manipulation respectively, 3 times a week, a total of two weeks. The clinical efficacy, changes of visual analogue scale (VAS) and the recurrence rate after 15 d of follow-up treatment were observed before and after treatment. The differences were statistically significant ( P <0.05). [Results] After treatment, the VAS and the recurrence rate after 15 d of treatment in the observation group were significantly lower than those in the control group ( P <0.05). After treatment, the total effective rate was 73.33% in the control group and 93.33% in the observation group ( P <0.05). [Conclusions] The effect of four-step tendon regulating manipulation in the treatment of thumb stenotic tenosynovitis is ideal. The effect is significantly better than that of traditional Chinese medicine in improving thumb pain and function, which is worthy of clinical promotion. 展开更多
关键词 Taking reinforcement first Four-step tendon regulating manipulation stenotic tenosynovitis of thumb
下载PDF
Influence of magnetic field and Hall currents on blood flow through a stenotic artery 被引量:9
2
作者 Kh.S.Mekheimer M.A.El Kot 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2008年第8期1093-1104,共12页
A micropolar model for blood simulating magnetohydrodynamic flow through a horizontally nonsymmetric but vertically symmetric artery with a mild stenosis is presented. To estimate the effect of the stenosis shape, a s... A micropolar model for blood simulating magnetohydrodynamic flow through a horizontally nonsymmetric but vertically symmetric artery with a mild stenosis is presented. To estimate the effect of the stenosis shape, a suitable geometry has been considered such that the horizontal shape of the stenosis can easily be changed just by varying a parameter referred to as the shape parameter. Flow parameters, such as velocity, the resistance to flow (the resistance impedance), the wall shear stress distribution in the stenotic region, and its magnitude at the maximum height of the stenosis (stenosis throat), have been computed for different shape parameters, the Hartmann number and the Hall parameter. This shows that the resistance to flow decreases with the increasing values of the parameter determining the stenosis shape and the Hail parameter, while it increases with the increasing Hartmann number. The wall shear stress and the shearing stress on the wall at the maximum height of the stenosis possess an inverse characteristic to the resistance to flow with respect to any given value of the Hartmann number and the Hall parameter. Finally, the effect of the Hartmann number and the Hall parameter on the horizontal velocity is examined. 展开更多
关键词 stenotic artery Hall currents blood flow
下载PDF
NEEDLE-PRICKING TREATMENT FOR STENOTIC TENOVAGINITIS
3
作者 薛远志 李刚 《World Journal of Acupuncture-Moxibustion》 1996年第1期49-51,共3页
In this paper, effects of needle-pricking plus TDP lamp radiation and medication onstenotic tenovaginitis are compared. In the needle-pricking group, a three-edged needle is inserted intothe subcutaneous tissues perpe... In this paper, effects of needle-pricking plus TDP lamp radiation and medication onstenotic tenovaginitis are compared. In the needle-pricking group, a three-edged needle is inserted intothe subcutaneous tissues perpendicularly after the pain point of the affected finger is detected, then theneedIe body is inclined along the longitudinal axis of vagina tendinis, and the tip of the needle is movedhorizontally to prick the vagina tendinis for a few times until no snapping occurs when the patient isflexing and stretching his diseased finger. In the medication group, the injection of Prednisolone andProcaine is given topically. Results show that the therapeutic effect of needle pricking is superior tothat of medication (P【0. 01). Moreover, the recurrence rate of the needle-pricking group is lower. 展开更多
关键词 stenotic tenovaginitis Needle-pricking TDP LAMP RADIATION
下载PDF
The Wall Shear Stress of a Pulsatile Blood Flow in a Patient Specific Stenotic Right Coronary Artery
4
作者 Biyue Liu 《Engineering(科研)》 2013年第10期396-399,共4页
A computer simulation of the blood flow in a patient specific atherosclerotic right coronary artery is carried out to study the blood flow pattern and the wall shear stress (WSS) distribution in the artery. Both tempo... A computer simulation of the blood flow in a patient specific atherosclerotic right coronary artery is carried out to study the blood flow pattern and the wall shear stress (WSS) distribution in the artery. Both temporal and special distribution patterns of the WSS of the non-Newtonian blood flow are presented and the regions on the lumen surface where the WSS is constantly lower than 1N/m2are identified. 展开更多
关键词 WALL SHEAR Stress stenotic RIGHT CORONARY ARTERY Non-Newtonian
下载PDF
Mathematical modeling and parametric investigation of blood flow through a stenosis artery 被引量:1
5
作者 A.ALI M.HUSSAIN +1 位作者 M.S.ANWAR M.INC 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2021年第11期1675-1684,共10页
In this study,a mathematical model is formulated to examine the blood flow through a cylindrical stenosed blood vessel.The stenosis disease is caused because of the abnormal narrowing of flow in the body.This narrowin... In this study,a mathematical model is formulated to examine the blood flow through a cylindrical stenosed blood vessel.The stenosis disease is caused because of the abnormal narrowing of flow in the body.This narrowing causes serious health issues like heart attack and may decrease blood flow in the blood vessel.Mathematical modeling helps us analyze such issues.A mathematical model is considered in this study to explore the blood flow in a stenosis artery and is solved numerically with the finite difference method.The artery is an elastic cylindrical tube containing blood defined as a viscoelastic fluid.A complete parametric analysis has been done for the flow velocity to clarify the applicability of the defined problem.Moreover,the flow characteristics such as the impedance,the wall shear stress in the stenotic region,the shear stresses in the throat of the stenosis and at the critical stenosis height are discussed.The obtained results show that the intensity of the stenosis occurs mostly at the highest narrowing areas compared with all other areas of the vessel,which has a direct impact on the wall shear stress.It is also observed that the resistive impedance and wall shear pressure get the maximum values at the critical height of the stenosis. 展开更多
关键词 stenotic artery blood flow finite difference method Navier-Stokes equation
下载PDF
Couple stress nanofluid flow through a bifurcated artery—Application of catheterization process
6
作者 KM Surabhi Arpitha Ravikanti +1 位作者 D.Srikanth D.Srinivasacharya 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2021年第4期492-511,共20页
In this article,we are exploring the hemodynamics of nanofluid,flowing through a bifurcated artery with atherosclerosis in the presence of a catheter.For treating obstruction in the artery,one can use the catheter who... In this article,we are exploring the hemodynamics of nanofluid,flowing through a bifurcated artery with atherosclerosis in the presence of a catheter.For treating obstruction in the artery,one can use the catheter whose outer surface is carrying the drug coated with nano-particles.The resultant solvent is considered as blood nano-fluid.Blood being a complex fluid,is modeled by couple stress fluid.In the presence of nano-particles,the temperature and the concentration distribution are understood in a bifurcated stenotic artery.The concluded mathematical model is governed by coupled non-linear equations,and are solved by using the homotopy perturbation method.Consequently,we have explored is the effects of fluid and the embedded geometric parameters on the hemodynamics characteristics.It is also realized that high wall shear stress exists for couple stress nano-fluid when compared to Newtonian nano-fluid.which is computed at a location corresponding to maximum constriction(z=12.5)of the artery. 展开更多
关键词 couple stress uid bifurcated stenotic artery homotopy perturbation method wall shear stress
下载PDF
A Study for Analyzing the Effect of Overlapping Stenosis and Dilatation on Non-Newtonian Blood Flow in an Inclined Artery
7
作者 Mukesh Kumar Sharma Vinay Nasha P. R. Sharma 《Journal of Biomedical Science and Engineering》 2016年第12期576-596,共21页
The stenosis in the artery, which reduces the flow passage to blood, is a common cardiovascular disease that is responsible even for cardiac arrest sometimes. The hemodynaics reveals that the severe blockage in an art... The stenosis in the artery, which reduces the flow passage to blood, is a common cardiovascular disease that is responsible even for cardiac arrest sometimes. The hemodynaics reveals that the severe blockage in an artery due to stenosis generates pressure tangential stress that impacts adversely on the arterial wall downstream to stenosis and weakens the arterial wall. The site of weakened wall in the artery generates post stenotic dilatation. The objective of this paper is to study flow of blood, of non-Newtonian in nature described by Herschel-Bulkley model, in a diseased artery suffering with partly overlapped two stenoses and a dilatation distal to the stenoses. A mathematical model, describing the blood flow, has been derived using Navier-Stokes equations along with the prescribed geometry of the diseased artery. The expressions of velocity profile, resistive impedance to flow and wall shear stress (skin-friction) are derived. The effect of inclination of the vessel on the resistive impedance to flow is discussed along with the effect of rheological and geometrical parameters on the resistive impedance to flow and skin friction. 展开更多
关键词 stenotic Artery Overlapped Stenoses DILATATION Herschel-Bulkley Blood Yield Stress Resistive Impedance
下载PDF
Percutaneous transluminal stenting in patients with carotid artery stenosis 被引量:1
8
作者 张瑞岩 沈卫峰 何世华 《Chinese Medical Journal》 SCIE CAS CSCD 2001年第11期16-19,102,共5页
Objective To assess the efficacy and safety of percutaneous transluminal stenting for patients with carotid artery stenosis.Methods Selective percutaneous transluminal stenting was performed for patients with symptoma... Objective To assess the efficacy and safety of percutaneous transluminal stenting for patients with carotid artery stenosis.Methods Selective percutaneous transluminal stenting was performed for patients with symptomatic carotid artery stenosis(luminal narrowing ≥ 70%).Success rates and complications associated with the procedures were observed.During six months of follow-up,both recurrent symptom and restenosis rates were recorded.Results There were 17 bifurcating lesions among 27 stenoses in 26 patients,of whom 18 had concomitant coronary artery diseases.The acute procedural success rate was 96.3%(26/27),and the degree of stenosis was reduced from 88.6% ± 8.9%(range 70 - 100)to 0.4% ± 2.0%(range 0 - 10).Six patients developed severe bradycardia and hypotension,and 3 experienced transient loss of consciousness during balloon dilatation.During hospitalization,2 patients experienced loss of consciousness and convulsion,respectively,due to hyperperfusion,and both recovered 12 hours later.There were 2 minor stroke cases (7.4%)but no cases of major stroke or death.At the 6-month follow-up,there were no cases of TIA or new onset of stroke.There was no restenosis detected in 16 cases using angiography and in 10 cases using MRI in 6 to 16 months of follow-up.Conclusions Percutaneous transluminal stenting for patients with carotid artery stenosis has a high procedural success rate with few and acceptable complications.Few patients suffered from recurrent symptoms or showed restenosis in long-term follow-up. 展开更多
关键词 percutaneous transluminal stenting · carotid artery stenotic disease · atherosclerosis
原文传递
A HYDROMAGNETIC MATHEMATICAL MODEL FOR BLOOD FLOW OF CARREAU FLUID 被引量:2
9
作者 NAJMA SALEEM T. HAYAT A. ALSAEDI 《International Journal of Biomathematics》 2014年第1期173-186,共14页
This paper constructs a mathematical model for blood flow through an artery with mild stenosis. Constitutive equations for Carreau fluid are employed in the mathematical modeling. Analysis has been carried out in the ... This paper constructs a mathematical model for blood flow through an artery with mild stenosis. Constitutive equations for Carreau fluid are employed in the mathematical modeling. Analysis has been carried out in the presence of constant magnetic field. Symmetric and asymmetric shapes of stenosis are taken. Governing flow model is computed for the series solution. Whe flow quantities of interest, for instance, axial velocity, pressure gradient, pressure drop, impedance and shear stress at the walls of stenotic artery are described for various pertinent parameters entering into the problem. 展开更多
关键词 Carreau fluid magnetic field stenotic artery.
原文传递
A mathematical analysis of MHD blood flow of Eyring-Powell fluid through a constricted artery 被引量:1
10
作者 Najma Saleem Sufian Munawar 《International Journal of Biomathematics》 2016年第2期175-186,共12页
The present study deals with the flow of blood through a stenotic artery in the presence of a uniform magnetic field. Different flow situations are taken into account by considering the regular and irregular shapes of... The present study deals with the flow of blood through a stenotic artery in the presence of a uniform magnetic field. Different flow situations are taken into account by considering the regular and irregular shapes of stenosis lying inside the walls of artery. Blood inside the artery is assumed to be Eyring-Powell fluid. A mathematical model is developed and simplified under the physical assumptions of stenosis. The regular perturbation method is adopted to find the solutions for axial velocity and pressure gradient. The variations in pressure drop across the stenosis length, the impedance and the shear stress at the walls of stenotic artery are discussed in detail through graphs. It is observed that the Eyring-Powell fluid is helpful in reducing the resistance to the flow in stenotic artery. Moreover, symmetric form of stenosis is more hazardous as compared to asymmetric stenosis. 展开更多
关键词 Blood flow magnetic field stenotic artery Eyring-Powell fluid.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部