期刊文献+
共找到15,273篇文章
< 1 2 250 >
每页显示 20 50 100
Stent-assisted coiling of intracranial carotid ophthalmic segment aneurysm segment aneurysms:Long-term follow-up from a single center
1
作者 Wenquan Gu Geng Zhou +10 位作者 Aizada Aldiyarova Tengyue Liu Yi Zhang Weidong Liu Lingping Meng Binxian Gu MingHua Li Ming Su Chen Su Aihua Liu Wu Wang 《Journal of Interventional Medicine》 2023年第3期116-120,共5页
Background:To evaluate the efficacy of stent-assisted coiling(SAC)for the treatment of carotid ophthalmic segment aneurysm segment aneurysms(OSAs)of the internal carotid artery(ICA)through detailed long-term follow-up... Background:To evaluate the efficacy of stent-assisted coiling(SAC)for the treatment of carotid ophthalmic segment aneurysm segment aneurysms(OSAs)of the internal carotid artery(ICA)through detailed long-term follow-up of a large patient cohort.Methods:We retrospectively analyzed 88 consecutive patients with OSAs between January 2009 and January 2020 at our center.Angiographic results were evaluated using the modified Raymond grading system and clinical outcomes were evaluated using the mRS scale.The primary endpoints were major aneurysm recurrence and poor clinical outcomes for at least 18 months of follow-up.The patients were asked to attend clinical follow-up assessments and possibly undergo DSA or MR via telephone.Results:We enrolled 88 patients with 99 OSAs treated with coiling,of whom 76 were treated with SAC.The coiling procedures were successful in all 88 patients.Overall,complications occurred in 8 patients(9.1%).No procedure-related mortality was observed.67(76.1%)experienced immediate aneurysm occlusion at the end of the procedure.Long-term angiographic follow-up(18 months)was available in 45/88 aneurysms(51%)(average 18.7±5.2 months).Four patients continued their follow-up for 5 years after initial aneurysm treatment.After a clinical follow-up time of 28.7 months(range,12-51 months),85 patients(95.5%)achieved favorable clinical outcomes(mRS scores of 0-2).Conclusions:This study indicates that SAC treatment is a safe and effective therapeutic alternative for ruptured and unruptured OSAs.The procedural risks are low with relatively long-term effectiveness. 展开更多
关键词 Endovascular treatment stent-assisted coiling C6 segment aneurysm Occlusion rate Long-term follow-up
下载PDF
Application of 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm 被引量:1
2
作者 Qiuji Shao Qiang Li +4 位作者 Qiaowei Wu Tianxiao Lin Li Li Kaitao Chang Yingkun He 《Journal of Interventional Medicine》 2021年第2期71-76,共6页
Objectives:To assess 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm.Materials and methods:Between Oct 2018 and May 2019,we enrolled 25 ... Objectives:To assess 3D T1-SPACE combined with 3D-TOF sequence for follow-up evaluation of stent-assisted coil embolization for intracranial aneurysm.Materials and methods:Between Oct 2018 and May 2019,we enrolled 25 patients with intracranial aneurysm who underwent stent-assisted coil embolization.All patients were followed up for 6 to10 months after endovascular treatment(EVT)using 3D-TOF MRA,3D T1-SPACE and DSA to evaluate aneurysm occlusion and parent artery patency.Results:With regards to aneurysm occlusion,the specificity of 3D-TOF MRA was 86.9%(20/23)and the accuracy was 84%(21/25).There was no statistical significance(P=0.409)compared with the DSA.The parent artery by3D-TOF MRA showed that there were 14 patients with grade 3,8 patients with grade 2 and 3 patients with grade1.However,3D T1-SPACE showed that all 25 patients were grade 4,and were clearly displayed without metal artifacts.The comparison of the two MR techniques demonstrated that 3D T1-SPACE was superior to 3D-TOF MRA in the evaluation of parent artery(P<0.001).Conclusions:3D T1-SPACE sequence provides better image quality and higher accuracy for evaluating stented parent arteries compared to TOF-MRA.This study also shows that 3D-TOF MRA has a merit to evaluate aneurysm occlusion.The combination of these two modalities can be used as an optional follow-up evaluation after EVT of intracranial aneurysms. 展开更多
关键词 Intracranial aneurysm stent-assisted Magnetic resonance imaging FOLLOW-UP
下载PDF
Applications of multislice CT angiography in the surgical clipping and endovascular coiling of intracranial aneurysms 被引量:2
3
作者 Wenhua Chen Yilin Yang +4 位作者 Wei Xing Ya Peng Jianguo Qiu Zhongming He Qi Wang 《The Journal of Biomedical Research》 CAS 2010年第6期467-473,共7页
Prompt diagnosis and therapy of aneurysms are critical for patients with nontraumatic subarachnoid hemorrhage (SAH).The aim of our study was to assess the clinical usefulness of multislice computed tomography angiog... Prompt diagnosis and therapy of aneurysms are critical for patients with nontraumatic subarachnoid hemorrhage (SAH).The aim of our study was to assess the clinical usefulness of multislice computed tomography angiography (CTA) in the surgical and endovascular treatment of intracranial aneurysms.A total of 195 cases with 206 intracranial aneurysms underwent CTA.Fifty (24%) aneurysms underwent surgical clipping while 156 (76%) aneurysms underwent endovascular coiling.In the five missed aneurysms at digital substraction angiography and the nine aneurysms with mass intracerebral hematomas,surgical treatment was successfully performed based on 16-slice CTA alone,and the other 36 aneurysms were clipped on the main basis of the CTA.The intraoperative findings correlated well with the CTA findings and all aneurysms were clipped successfully.Sixteen-slice CTA image information has been shown to determine the choice of aneurysm therapy and assist the surgical and endovascular treatment of intracranial aneurysms. 展开更多
关键词 intracranial aneurysm computed tomography angiography CLIPPING coiling
下载PDF
Effect of Coiling Temperature on the Evolution of Texture in Ferritic Rolled Ti-IF Steel 被引量:1
4
作者 Zhaodong WANG Yanhui CUO Wenying XUE Xianghua LIU Cuodong WANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2007年第3期337-341,共5页
The effect of coiling temperatures on the evolution of texture in Ti-IF steel during ferritic hot rolling, cold rolling and annealing was studied. It was found that texture evolution at high temperature coiling is abs... The effect of coiling temperatures on the evolution of texture in Ti-IF steel during ferritic hot rolling, cold rolling and annealing was studied. It was found that texture evolution at high temperature coiling is absolutely different from that at low temperature one. The hot band texture includes a strong α-fiber as well as a weak γ-fiber after ferritic hot rolling and low temperature coiling. Both of them intensify after cold rolling and a γ-fiber with peak at {111}〈112〉 is the main texture of annealed samples. However, the main component of the hot band texture after high temperature coiling is v-fiber. After cold rolling, the intensity of γ texture reduces; α fiber (except {111}〈110〉 component) intensifies and a strong and well-proportioned γ-fiber forms in the annealed samples. 展开更多
关键词 Ti-IF steel Ferritic hot rolling coiling temperature TEXTURE
下载PDF
Effect of Coiling Temperature on Ti(C,N) Precipitation and Properties of Batch Annealed DC06EK Enamel Steel 被引量:3
5
作者 薛飞 董福涛 +3 位作者 TIAN Yaqiang 陈连生 DU Linxiu LIU Xianghua 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第3期697-702,共6页
The effects of hot-strip coiling temperature on Ti(C,N) precipitation, texture and hydrogen permeation behavior in DC06 EK enamel steel were investigated by TEM, EBSD test and electrochemical hydrogen permeation exp... The effects of hot-strip coiling temperature on Ti(C,N) precipitation, texture and hydrogen permeation behavior in DC06 EK enamel steel were investigated by TEM, EBSD test and electrochemical hydrogen permeation experiment. It was found that the Ti(C,N) particles in hot-strip coarsened with increasing coiling temperature, whereas after cold-rolling and annealing, the size difference of Ti(C,N) particles was lessened. The hot-strip coiling temperature has a significant impact on the recrystallized texture in the subsequent cold-rolled and annealed sheet. Hot-strip using high temperature(700 ℃) coiling leads to strong {111} recrystallized texture in annealed sheet, with peak intensity 9.2. On the contrary, in annealed sheets using hot-strip coiling at 650 ℃, their {111} recrystallized textures were weaker, which was also reflected in their rmvalues. Even though the hydrogen diffusion coefficient is slightly lower(7.76×10^(-5) mm^2/s) in annealed sheet using low temperature coiling(600 ℃), appropriately higher coiling temperature is more suitable for DC06 EK enamel steel combining both good drawability and fish-scale resistance. 展开更多
关键词 enamel steel coiling temperature Ti(C N) γ-fiber texture hydrogen diffusion
下载PDF
Safety and efficacy of complete versus near-complete coiling in treatment of intracranial aneurysms 被引量:4
6
作者 Guogdong Zhang Yongsheng Liu +3 位作者 Yongjian Liu Mingyi Wang Ke Li Feng Wang 《Journal of Interventional Medicine》 2020年第3期136-141,共6页
Objective:This study aimed to evaluate the clinical and angiographic outcomes of aneurysms that were completely or near-completely embolized and ascertain whether complete embolization is important in the stent-assist... Objective:This study aimed to evaluate the clinical and angiographic outcomes of aneurysms that were completely or near-completely embolized and ascertain whether complete embolization is important in the stent-assisted coiling(SAC)of intracranial aneurysms.Methods:This retrospective study enrolled 390 patients(417 aneurysms).Among them,complete(100%)or nearcomplete(>90%)angiographic obliteration of the aneurysms on immediate angiography was accomplished.Baseline characteristics,complications,angiography follow-up results,and clinical outcomes were analyzed.Results:Cumulative adverse events occurred in 30 patients(7.7%),including thromboembolic complications in 17(4.4%),intraoperative rupture in 10(2.6%),and others in 3(0.8%).Statistical analyses revealed an increased intraprocedural rupture rate in the initial completely occluded aneurysms(5.6%compared with 1.0%).The incidence of cumulative adverse events was higher in patients with completely occluded aneurysms(11.1%)than in those with near-completely occluded aneurysms(5.5%).Angiography follow-up was available for 173 aneurysms.Aneurysm occlusion status at follow-up was correlated with stent placement(p?0.000,odds ratio?5.847),size(p?0.000,odds ratio?6.446 for tiny aneurysms;and p?0.001,odds ratio?5.616 for small aneurysms),and initial aneurysm occlusion status(p?0.001,odds ratio?3.436).Complete occlusion at followup was seen in 82.6%of the initial complete occlusion group versus 63.0%of the initial near-complete occlusion group.The incidence of complete occlusion at follow-up was higher in the initial completely occluded aneurysms with SAC(100%)than in the initial completely occluded aneurysms with non-SAC(65.2%).Conclusions:Initial complete treatment may lead to higher complication rates and good clinical outcomes at follow-up.Stent placement may enhance progressive aneurysm occlusion.Initial complete occlusion with SAC can provide durable closure at follow-up. 展开更多
关键词 coil embolization Intracranial aneurysm STENT
下载PDF
Optimization of suspension system of heavy off-road vehicle for stability enhancement using integrated anti-roll bar and coiling spring mechanism 被引量:3
7
作者 Ilgar JAVANSHIR Andino MASELENO +1 位作者 Shahin TASOUJIAN Majid OVEISI 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第9期2289-2298,共10页
Short suspension system has an indispensable effect on vehicle handling and ride,so,optimization of vehicle suspension system is one of the most effective methods,which could considerably enhance the vehicle stability... Short suspension system has an indispensable effect on vehicle handling and ride,so,optimization of vehicle suspension system is one of the most effective methods,which could considerably enhance the vehicle stability and controllability.Motion control,stability maintenance and ride comfort improvement are fundamental issues in design of suspension system of off-road vehicles.In this work,a dependent suspension system mostly used in off-road vehicles is modeled using Trucksim software.Then,geometric parameters of suspension system are optimized using integrated anti-roll bar and coiling spring in a way that ride comfort,handling and stability of vehicle are improved.The simulation results of suspension system and variations of geometric parameters due to road roughness and different steering angles are presented in Trucksim and effects of optimization of suspension system during various driving maneuvers in both optimized and un-optimized conditions are compared.The simulation results indicate that the type of suspension system and geometric parameters have significant effect on vehicle performance. 展开更多
关键词 off-road vehicles HANDLING anti-roll bar coil spring vehicle lateral dynamic Trucksim software
下载PDF
Intelligent Control on Hot Strip Coiling Temperature 被引量:1
8
作者 Heping Liu Yanlong Zhao(Information Engineering School, University of Science and Technology Bejing, Beijing 100083, China)(Handan Iron & Steel (Group) Co, Handan 056015, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2000年第2期147-150,共4页
A new intelligent control scheme for hot strip coiling temperature is presented. In this scheme, the prediction mode1 of finishing temperature and the presetting model of main cooling zone are establish based on BP ne... A new intelligent control scheme for hot strip coiling temperature is presented. In this scheme, the prediction mode1 of finishing temperature and the presetting model of main cooling zone are establish based on BP neural network, the feed-forward open-loop control model of main cooling zone is constructed based on T-S fuzzy neural network, a new improved structure of T-S fuzzy neural network is developed, and the feedback close-loop control model of precision cooling zone is obtained based on fuzzy control. The effectiveness of the proposed scheme has been demonstrated by computer simulation with a satisfactory result. 展开更多
关键词 coiling temperature control laminar cooling fuzzy control neural network fuzzy neural network
下载PDF
The effect of cooling rate and coiling temperature on the microstructure and mechanical properties of a plain carbon steel 被引量:1
9
作者 ZHANG Chen HU Xiaoping +1 位作者 LIU Gang WANG Huanrong 《Baosteel Technical Research》 CAS 2018年第1期11-16,共6页
The effects of cooling rate and coiling temperature on microstructure and mechanical properties of a plain carbon steel were investigated by combining metallography and tensile experiments. The results indicate that f... The effects of cooling rate and coiling temperature on microstructure and mechanical properties of a plain carbon steel were investigated by combining metallography and tensile experiments. The results indicate that ferrite grain size is refined and bainite transformation occurs to ensure high strength and elongation, as the cooling rate is quick enough. Yield strength and tensite strength improve with the decreased finish cooling temperature, but the elongation decreases too significantly to meet the requirements. Thus, the cooling rate must be quick enough, and the appropriate coiling temperature should be carefully selected to obtain refined ferrite and a small amount of bainite to improve the strength while the plasticity is also ensured. Under this condition, the Mn element concentration can be reduced to save cost or produce higher strength steel with same chemical composition. 展开更多
关键词 plain carbon steel cooling rate coiling temperature
下载PDF
Application research on feedback control based on Dahlin algorithm for coiling temperature of hot strip
10
作者 WU Jianfeng WANG Xiaobo LIU Ye 《Baosteel Technical Research》 CAS 2012年第4期38-40,共3页
To improve the precision of the coiling temperature and the performance of the feedback control system with long pure time delay on hot strip mills, we analyzed the design process of the Dahlin algorithm in detail. Th... To improve the precision of the coiling temperature and the performance of the feedback control system with long pure time delay on hot strip mills, we analyzed the design process of the Dahlin algorithm in detail. The coiling temperature curves controlled by the PID algorithm and Dahlin algorithm were simulated and compared, which showed that the control precision with the Dahlin algorithm was higher than that with the PID algorithm. That was further verified by the production practice. 展开更多
关键词 Dahlin algorithm coiling temperature feedback control
下载PDF
Developing a Scale for Measuring Uncertainty in Patients with Unruptured Intracranial Aneurysms Undergoing Endovascular Coiling
11
作者 Mitsumi Masuda Hidenori Ohishi +1 位作者 Noriko Terunuma Ikuko Tojima 《Open Journal of Nursing》 2015年第10期917-926,共10页
A measure called the Uncertainty in Unruptured Intracranial Aneurysm Patients Undergoing Endovascular Coiling Scale (UUIACS) was developed and its validity and reliability were examined. The 49 questions that comprise... A measure called the Uncertainty in Unruptured Intracranial Aneurysm Patients Undergoing Endovascular Coiling Scale (UUIACS) was developed and its validity and reliability were examined. The 49 questions that comprised the original draft of the UUIACS were created based on interview data. Based on data from 172 participants, exploratory and confirmatory factor analyses were conducted. As a result of exploratory factor analysis, the UUIACS e retained 17 items and extracted four factors (“Lack of decision-making cues”, “Lack of information and complexity of information interpretation”, “The ambiguous nature of the disease”, and “The unpredictable living with UIA”). All of the UUIACS items showed adequate internal consistency. Between the UUIAC scale and the Universal Uncertainty in Illness Scale (UUIS), the Health Locus of Control (HLC) scale, and the SF-36v2&reg (Japanese version), positive correlations were found between the UUIACS and UUIS, and the HLC scale at a 1% significance level indicating concurrent validity. According to confirmatory factor analysis, the UUIACS had an acceptable goodness of fit. Given these findings, the UUIACS was judged to have satisfied the criteria for use in a clinical setting, although further investigation was required. 展开更多
关键词 UNRUPTURED Intracranial ANEURYSMS ENDOVASCULAR coiling UNCERTAINTY SCALE
下载PDF
Vasospasm as a Complication after Aneurysmal Rupture and Its Relation with Surgical Clipping and Endovascular Coiling among a Georgian Sample
12
作者 Maha Kassem Lama Alchaar +10 位作者 Ahmed Abdelkader Mohammad Eghbalbakhtiary Koka Gogichashvili Mirza Khinikadze Shriniwas Chandrasekhar Yadav Astha Zambani Sonali Mankar Mahalakshmi Jayasankar Mohamed Abdelsattar Atta Ismail Ali Sarah Ibrahim Natia Iashvili 《World Journal of Neuroscience》 CAS 2022年第3期153-162,共10页
Background: Potentially lethal, aneurysmal subarachnoid hemorrhage has a bad prognosis for many individuals. Over the past few decades, endovascular and surgical interventions have been developed, including surgical c... Background: Potentially lethal, aneurysmal subarachnoid hemorrhage has a bad prognosis for many individuals. Over the past few decades, endovascular and surgical interventions have been developed, including surgical clipping, and endovascular coiling. Patients who have aSAH are also susceptible to delayed cerebral ischemia and cerebral vasospasm. The aim of this study is to compare the outcome of endovascular coiling with surgical clipping in patients with SAH, specifically in relation to prevalence of vasospasm, in the country of Georgia. Method: In this study, we present a retrospective review of the outcomes of 217 patients with acute subarachnoid hemorrhage who underwent endovascular coiling or surgical clipping. The data were gathered from patients who are admitted to New Vision University Hospital and Caucasus Medical Center in Tbilisi, Georgia, between 2017 and 2022. Results: Vasospasm was prevalent in 217 of the patients who had aneurysmal rupture when they first appeared. Endovascular coiling or surgical clipping was used to treat aneurysmal rupture. In our sample, 24.81 percent of patients who underwent coiling experienced vasospasm after 14 days, compared to 31.25 percent of patients who underwent clipping. After endovascular coiling and surgical clipping, the severity of vasospasm was only slightly different, according to Lindegaard ratios. Finally, 32 patients (23.35 percent) died after coiling whereas 55 patients (68.75 percent) died within three decades of clipping. Conclusion: After 5 years of data collection, this study has demonstrated the most favorable option for treatment is endovascular coiling. However, the treatment choice takes multiple factors into account, and clipping is not ideal for some ruptured aneurysms. Despite the fact that endovascular coiling is usually successful and minimally invasive, complications can occur and additional monitoring and potential surgical intervention are indicated. 展开更多
关键词 ANEURYSMS Subarachnoid Hemorrhage Surgical Clipping Endovascular coiling VASOSPASM
下载PDF
Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system 被引量:1
13
作者 Yaohui Wang Weimin Wang +3 位作者 Hui Liu Shunzhong Chen Feng Liu Qiuliang Wang 《Magnetic Resonance Letters》 2024年第1期1-9,共9页
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f... The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets. 展开更多
关键词 MRI Gradient coil Superconducting magnet Cryogen-free Magnetic shielding
下载PDF
Stent-assisted recanalization of atherosclerotic intracranial stenosis
14
作者 Soo Mee Lim Dae Chul 《介入放射学杂志》 CSCD 2006年第9期571-574,共4页
关键词 TIA stent-assisted recanalization of atherosclerotic intracranial stenosis
下载PDF
Clipping versus Coiling in Ruptured Aneurysms of the Anterior Cerebral Circulation
15
作者 Farrag Mohammad Takashi Horiguchi +1 位作者 Katsuhiro Mizutani Kazunari Yoshida 《Open Journal of Modern Neurosurgery》 2020年第1期88-104,共17页
Objective: To evaluate and compare the outcomes of microsurgical clipping and endovascular coiling of ruptured anterior cerebral circulation aneurysms. Methods: The current study retrospectively included 61 patients p... Objective: To evaluate and compare the outcomes of microsurgical clipping and endovascular coiling of ruptured anterior cerebral circulation aneurysms. Methods: The current study retrospectively included 61 patients presented with subarachnoid hemorrhage (SAH), treated by clipping or coiling for ruptured aneurysms located in anterior circulation. Anatomic outcome and post-operative ischemic events were evaluated. The primary clinical outcomes were evaluated as operative complications while the secondary clinical outcome was evaluated by modified Rankin scale (mRS) at discharge. Results: Of 61 ruptured aneurysms, 47 and 14 were treated by surgery and coiling, respectively. The average follow-up duration was 19.1 ± 18.6 months for clipping and 21.7 ± 14.8 months for coiling. Complete occlusion was greater in surgery group (80.8%) than endovascular group (21.4%). Re-growth occurred in 2 cases of the coiling group only. Ischemic events were encountered in both groups;silent ones were higher in coiling group (21.4%) than in clipping group (6.3%), while symptomatic ones were higher in the clipping group (49%). Good outcome (mRS 0 - 2) was 51% and 71.4% after clipping and coiling respectively. Postoperative hospital period was longer after clipping (P = 0.04). Conclusions: For anterior circulation ruptured aneurysms, both treatments are feasible, coiling showed lower rate of morbidity while clipping results were better regarding durability and recurrence. Coil embolization may be preferred, which is the current point proved by the RCT like ISAT, but if you choose the patients carefully and find out the optimal candidate for the clipping, the clipping is still enough feasible as a mainstream. 展开更多
关键词 ANTERIOR Circulation SAH CLIPPING coiling RUPTURED ANEURYSMS
下载PDF
Effect of post-coiling transformation on coil collapse of hot-rolled advanced high-strength steel
16
作者 ZHONG Yong 《Baosteel Technical Research》 CAS 2022年第3期27-34,共8页
In this paper, the effect of hot-rolling processing parameters on the post-rolling transformation behavior of C-Mn-Cr-Cu weather-resistant martensitic steel was investigated.Results indicate that the post-rolling tran... In this paper, the effect of hot-rolling processing parameters on the post-rolling transformation behavior of C-Mn-Cr-Cu weather-resistant martensitic steel was investigated.Results indicate that the post-rolling transformation behavior, particularly the post-coiling transformation behavior, strongly depends on the coiling temperature.Under a high coiling temperature, ferrite/pearlite transformation was mainly observed with a low trans-formation speed and transformation dilation after coiling.With decreasing coiling temperature, the proportion of bainite transformation increased with an increased transformation speed and transformation dilation.The dependence of transformation behavior on the coiling temperature could be one of the most important reasons behind the coil collapse of the experimental steel.The optimization of hot-rolling and coiling processing parameters of the steel strip, including laminar flow cooling, coiling temperature, and suspension time on the winding machine, can signi-ficantly reduce the transformation dilation of the steel after hot rolling, thus effectively controlling the coil collapse of the steel. 展开更多
关键词 AHSS hot rolling coiling phase transformation thermal dilation
下载PDF
Degree of style coiling is associated with corolla-tube length in the nectarless flowers of Roscoea schneideriana
17
作者 Bo Wang Ze-Yu Tong +3 位作者 Ying-Ze Xiong Xiao-Fan Wang W.Scott Armbruster Shuang-Quan Huang 《Plant Diversity》 SCIE CAS CSCD 2023年第6期748-751,共4页
The plant-pollinator‘arms race’model posits that a major driver of the evolution of elongated corollas in flowers is reciprocal selection for‘morphological fit’between pollinator-tongue length and access distance ... The plant-pollinator‘arms race’model posits that a major driver of the evolution of elongated corollas in flowers is reciprocal selection for‘morphological fit’between pollinator-tongue length and access distance to nectar(usually corolla-tube length).Evidence for the pollinator-mediated selection on tube length and evolution of multiple,correlated floral traits remains inconclusive.To gain possible insights into the strength of stabilizing selection by assessing standing phenotypic variation,we measured a series of functionally important floral traits,including corolla tube length and‘effective’tube depth and degree of style coiling.We then calculated coefficients of variation(CV)for these traits in three field populations of R.schneideriana.Unlike in most long-tubed flowers,the bottom part of the corolla tube is completely occupied by the style,with no room for nectar.The length of this portion of the corolla tube was more variable(higher CV)than the upper part of the corolla tube,suggesting that functional tube depth was under stronger stabilizing selection.The degree of style coiling was negatively related to the corolla-tube length in all three populations of R.schneideriana,suggesting that there may be conflicting selection acting on style length and corolla-tube length,which are otherwise usually tightly correlated.Given the lack of nectar in the flowers of this species,the long corolla tubes and long styles may represent morphological holdovers from ancestors that were pollinated by long-tongued pollinators,as is still seen in related species in the western Himalayas. 展开更多
关键词 Coefficient of variation coiled style Corolla-tube length Nectar depth Pollinator shift Trait covariation
下载PDF
Microstructure Development after Coiling Process in Low-Si Content TRIP-Assisted Steels
18
作者 Seyed Mohammad Kazem Hosseini Abbass Zarei-Hanzaki Stephen Yue 《Journal of Mechanics Engineering and Automation》 2013年第10期650-655,共6页
The present work aimed to investigate the effect of coiling process conditions on microstructure development in a low-Si content TRIP (transformation-induced plasticity)-assisted steel after thermomechanical process... The present work aimed to investigate the effect of coiling process conditions on microstructure development in a low-Si content TRIP (transformation-induced plasticity)-assisted steel after thermomechanical processing. In this framework, compression samples which were deformed above Tnr and then intercritically annealed were held isothermally for different durations at temperatures below bainite transformation start temperature. Microstructure of samples were characterized by optical and electron microscopy, XRD (X-ray diffraction) and M6ssbauer spectroscopy. The results indicated that due to low-silicon content of the present steel, the incomplete bainite reaction phenomena was not observed and, hence, the maximum carbon enrichment of residual austenite was achieved in the samples which held for short durations. It was also shown that the maximum carbon enrichment and volume fraction of residual austenite were achieved at intermediate bainite hold temperature of 450 ℃ as the result of competing phenomena, such as microstructural refinement, dislocation density, carbide precipitation and growth. 展开更多
关键词 Thermomechanical processing TRIP-steels bainite transformation coiling process retained austenite
下载PDF
Enhancing silicon spectral emission in LIBS using Tesla coil discharge
19
作者 Shuang CUI Yang LIU +1 位作者 Anmin CHEN Mingxing JIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期132-139,共8页
Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity ... Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity of LIBS,increasing the spectral emission intensity is crucial.This paper explores the use of Tesla coil(TC)discharge as an alternative to spark discharge in silicon LIBS.The study examines the influence of TC discharge on both time-integrated and timeresolved spectra,with and without TC discharge;the corresponding electron temperature and density are obtained.The results show that TC discharge significantly amplifies the spectral intensity,improving signal sensitivity in LIBS analysis.Specifically,in the laser energy range from 7.4 to 24.0 mJ,TC discharge increased the average spectral line intensities of Si(II)385.60 nm and Si(I)390.55 nm by factors of 8.4 and 5.1,respectively.Additionally,the average electron temperature and density were enhanced by approximately 3.2%and 4.2%,respectively,under TC discharge.The advantages of TC discharge include higher energy deposition,extended discharge duration,reduced electrode erosion,and enhanced safety.This research contributes to advancing LIBS technology and expanding its applications in various fields. 展开更多
关键词 LIBS Tesla coil spectral enhancement SILICON
下载PDF
Giant aneurysm at the junction of the internal carotid and persistent primitive trigeminal artery (PPTA) treated with endovascular GDC coiling, a case report of experience in Ramathibodi hospital
20
作者 P. Jiarakongmun S. Pongpech J. Suvikrom 《介入放射学杂志》 CSCD 2004年第S1期86-87,共2页
关键词 PPTA treated with endovascular GDC coiling a case report of experience in Ramathibodi hospital Giant aneurysm at the junction of the internal carotid and persistent primitive trigeminal artery
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部