Objectives To study characteristics of psychosomatic symptoms related to sterilization, to find out risk factors and their roles ascribed to psychosomatic symptoms, and to establish a mathematic model for screening...Objectives To study characteristics of psychosomatic symptoms related to sterilization, to find out risk factors and their roles ascribed to psychosomatic symptoms, and to establish a mathematic model for screening out susceptible women. Methods: This study enrolled 776 women in rural area at three counties of Linxiang, Qiyang, Changsha of Hunan province in China between February 1990 and April 1992. Brief Neurosis Screening Scale (BNSS), Symptom Checklist 90 (SCL-90), sensitivity to pain, suggestibility were used to indicate subjects' psychological status. Logistic regression model and retrograde discriminant analysis were applied to develop a mathematical model. Results: Prevalence of psychosomatic reactions or symptoms was 54.8% before sterilization, 26.6% at three months and 16.4% at one year after operation respectively. Psychosomatic symptoms were verified to be the result of joint effects of multiple risk factors. The following risk factors were associated with postoperative symptoms: anger-hostility (RR=33.71), high suggestibility (RR=4.53), high neuroticism (RR=3.44), sensitivity to pain (RR=2.14) and operative sites (RR=2.05). A mathematical model to estimate the probability of developing psychosomatic symptoms in sterilization was established.Conclusions: More than half of women suffered from psychosomatic reactions before operation, and some of them did not recover after operation. The postoperative psychosomatic symptoms are the joint effect of multiple risk factors.展开更多
One thousand and twenty-nine women with microsurgical tubal reversal after tubal sterilization were followed up.The rate of intrauterine pregnancy was found to be 93.29%.The rate of intrauterine pregnancy was the high...One thousand and twenty-nine women with microsurgical tubal reversal after tubal sterilization were followed up.The rate of intrauterine pregnancy was found to be 93.29%.The rate of intrauterine pregnancy was the highest(73.28%)in the first year after tubal reversal.In the first year,the chance of pregnancy in the first 6 months was higher (54.81%)than that(40.86%)in the second 6 months(P<0.01),and the chance in the first 3 months was higher(37.41%)than that(27.80%)in the second 3 months(P<0.01).The rates of ectopic pregnancy after tubal reversal in various stages were not significantly different(P>0.05).The rate of intrauterine pregnancy was not related with the period from sterilization to tubal reversal.Early postoperative hydropertubation can only decrease the rate of intrauterine pregnancy.The rate of intra uterine pregnancy of the tubal reversal after Uchida's method and clips tubal sterilization was higher than that after Pomeroy's tubal ligation.The reanastomosis of isthmus and isthmus resulted in the highest rate of intra uterine pregnancy,so we think that Uchida's or elips tubal sterilization in the isthmus of the tubal are ideal and reversible techniques at present.展开更多
The present objective is to observe the side effects and complications of fem ale tubalsterilization by phenol-atabrinepaste (PAP) and phenolm ucilage (PM). 1 705 eligible w om en w ere divided random ly into tw o g...The present objective is to observe the side effects and complications of fem ale tubalsterilization by phenol-atabrinepaste (PAP) and phenolm ucilage (PM). 1 705 eligible w om en w ere divided random ly into tw o groups, 871 usinig PAP and 834 w om en using PM. Results: Thefeverratesw ere8.0and 4.4( P< 0.01 ) respec- tively in group PAP and group PM. Infection rates of the appendages w ere 2.3 and 1.2 respectively. The incidence of chem ical peritonitis, w ithin the lim its of pelvic cavity, w ere 1.1and 2.4respectively. Perforation of uterus, pelvic ab- scessand ectopicpregnancy w ere notfound during thisobservation. Slightabdom inal pain after the proceduresw ere 33.6and 30.8respectively. Slightvaginalbleed- ing after the procedure w as 23.2 and 18.0 respectively. Menstruation of the w om en w as not affected by the instillation. This five-year follow -up study neither show ed a positivePap testnor a potentialdeseasecaused by thesterilizing agents. This technique isa safe and efficientm ethod for fem ale sterilization.展开更多
A multi center randomized clinical trial was adopted in the present study. 1705 eligible women with identical demographic and gynecological characteristics were divided into two groups: 871 using phenol atabrine pas...A multi center randomized clinical trial was adopted in the present study. 1705 eligible women with identical demographic and gynecological characteristics were divided into two groups: 871 using phenol atabrine paste (PAP) and 834 using phenol mucilage (PM). The five year follow up rates for the two groups were 97.5% and 98.1%, respectively. The multiple decrement life table analysis showed that there was a significant difference in the gross cumulative failure rates between the two groups. The 60th month gross cumulative failure rates for PAP group and PM group were 4.61% and 11.87%, respectively, thus indicating the efficacy of PAP to be significantly higher than that of PM. 97.7% users had cervical smear examinations, but no suspected cancer cells or cancer cells were found. Meanwhile, there was no known diseases related to the chemical reagent. This follow up study indicates that tubal sterilization by chemical instillation is a simple,safe and efficient female method. It suggested that this method would be introduced to a wider use on the basis of modification in the composition of chemical agents, standardized operational procedure, and improved administrative regulation in the use of this technology.展开更多
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup...Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.展开更多
Tubal ligation or tubectomy (also known as having one's "tubes tied" (ligation)) is a surgical procedure for sterilization in which a woman's fallopian tubes are clamped and blocked, or severed and s...Tubal ligation or tubectomy (also known as having one's "tubes tied" (ligation)) is a surgical procedure for sterilization in which a woman's fallopian tubes are clamped and blocked, or severed and sealed, either method of which prevents eggs from展开更多
Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emergi...Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emerging field of plasma application,which puts higher requirements on the miniaturization,operational stability,and operating cost of plasma device.In this study,a novel magnetically driven rotating gliding arc(MDRGA)discharge device was used to sterilize Lactobacillus fermentation.Compared with the traditional gas-driven gliding arc,this device has a simple structure and a more stable gliding arc.Simulation using COMSOL Multiphysics showed that adding permanent magnets can form a stable magnetic field,which is conducive to the formation of gliding arcs.Experiments on the discharge performance,ozone concentration,and sterilization effect were conducted using different power supply parameters.The results revealed that the MDRGA process can be divided into three stages:starting,gliding,and extinguishing.Appropriate voltage was the key factor for stable arc gliding,and both high and low voltages were not conducive to stable arc gliding and ozone production.In this experimental setup,the sterilization effect was the best at 6.6 kV.A high modulation duty ratio was beneficial for achieving stable arc gliding.However,when the duty ratio exceeded a certain value,the improvement in the sterilization effect was slow.Therefore,considering the sterilization effect and energy factors comprehensively,we chose 80%as the optimal modulation duty ratio for this experimental device.展开更多
The massive use of antibiotics has led to the aggravation of bacterial resistance and also brought environmental pollution problems.This poses a great threat to human health.If the dosage of antibiotics is reduced by ...The massive use of antibiotics has led to the aggravation of bacterial resistance and also brought environmental pollution problems.This poses a great threat to human health.If the dosage of antibiotics is reduced by increasing its bactericidal performance,the emergence of drug resistance is certainly delayed,so that there's not enough time for developing drug resistance during treatment.Therefore,we selected typical representative materials of metal Ag and semiconductor ZnO nano-bactericides to design and synthesize Ag/ZnO hollow core-shell structures(AZ for short).Antibiotics are grafted on the surface of AZ through rational modification to form a composite sterilization system.The research results show that the antibacterial efficiency of the composite system is significantly increased,from the sum(34.7%+22.8%-57.5%)of the antibacterial efficiency of AZ and gentamicin to 80.2%,net synergizes 22.7%,which fully reflects the effect of 1+1>2.Therefore,the dosage of antibiotics can be drastically reduced in this way,which makes both the possibility of bacterial resistance and medical expenses remarkably decrease.Subsequently,residual antibiotics can be degraded under simple illumination using AZ-self as a photocatalyst,which cuts off the path of environmental pollution.In short,such an innovative route has guiding significance for drug resistance.展开更多
There is a currently a lack of large-area plasma sterilization devices that can intelligently identify the shape of a wound for automatic steriliza-tion.For this reason,in this work,a plasma sterilization device with ...There is a currently a lack of large-area plasma sterilization devices that can intelligently identify the shape of a wound for automatic steriliza-tion.For this reason,in this work,a plasma sterilization device with wound-edge recognition was developed using afield-programmable gate array(FPGA)and a high-performance image-processing platform to realize intelligent and precise sterilization of wounds.SOLIDWORKS was used to design the mechanical structure of the device,and it was manufactured using 3D printing.The device used an improvement of the traditional Sobel detection algorithm,which extends the detection of edges in only the x and y directions to eight directions(0○,45○,90○,135○,180○,225○,270○,and 315○),completing the wound-edge detection by adaptive thresholding.The device can be controlled according to different shapes of sterilization area to adjust the positioning of a single plasma-jet tube in the horizontal plane for two-dimensional move-ment;the distance between the plasma-jet tube and the surface of the object to be sterilized can be also adjusted in the vertical direction.In this way,motors are used to move the plasma jet and achieve automatic,efficient,and accurate plasma sterilization.It was found that a good sterilization effect could be achieved at both the culture-medium level and the biological-tissue level.The ideal sterilization parameters at the culture-medium level were a speed of 2 mm/s and aflow rate of 0.6 slm,while at the biological-tissue level,these values were 1 mm/s and 0.6 slm,respectively.展开更多
Guilin rice noodles, a unique cuisine from Guilin, Guangxi, is renowned both domestically and internationally as one of the top ten “Guilin Classics”. Utilizing a heat conduction model, this study explores the effec...Guilin rice noodles, a unique cuisine from Guilin, Guangxi, is renowned both domestically and internationally as one of the top ten “Guilin Classics”. Utilizing a heat conduction model, this study explores the effectiveness of the cooking process in sterilizing Guilin rice noodles before consumption. The model assumes that a large pot is filled with boiling water which is maintained at a constant high temperature heat resource through continuous gentle heating. And the room temperature is set as the initial temperature for the preheating process and the final temperature for the cooling process. The objective is to assess whether the cooking process achieves satisfactory sterilization results. The temperature distribution function of rice noodle with time is analytically obtained using the separation of variables method in the three-dimensional cylindrical coordinate system. Meanwhile, the thermal diffusion coefficient of Guilin rice noodles is obtained in terms of Riedel’ theory. By analyzing the elimination characteristics of Pseudomonas cocovenenans subsp. farinofermentans, this study obtains the optimal time required for effective sterilization at the core of Guilin rice noodles. The results show that the potential Pseudomonas cocovenenans subsp. farinofermentans will be completely eliminated through continuously preheating more than 31 seconds during the cooking process before consumption. This study provides a valuable reference of food safety standards in the cooking process of Guilin rice noodles, particularly in ensuring the complete inactivation of potentially harmful strains such as Pseudomonas cocovenenans subsp. farinofermentans.展开更多
Objective:This study aims to evaluate the application value of biological monitoring and different types of chemical indicator cards in batch monitoring of hydrogen peroxide low-temperature plasma sterilization.The go...Objective:This study aims to evaluate the application value of biological monitoring and different types of chemical indicator cards in batch monitoring of hydrogen peroxide low-temperature plasma sterilization.The goal is to standardize the selection of loading conditions for this sterilization method and avoid positive biological monitoring results.Methods:Physical monitoring,Class I chemical indicator card monitoring,Class IV chemical indicator card monitoring,and biological monitoring were used to monitor the hydrogen peroxide low-temperature plasma sterilization process.The sterilization effect on instruments inside the Johnson&Johnson 100S plasma sterilizer was monitored and the qualification of various monitoring methods was compared.Results:The comparison showed that when non-standard or adsorption-prone packaging materials were used,the interception rate of biological monitoring and Class IV chemical indicator cards was significantly higher than that of physical monitoring and Class I chemical indicator cards.These methods more intuitively and effectively detected sterilization failures.Conclusion:Biological monitoring and Class IV chemical indicator cards are safe,fast,accurate,and easy to interpret in hydrogen peroxide low-temperature plasma sterilization,especially for monitoring instruments inside packages.They provide a reliable basis for the release of sterilized instrument packages.Identifying the reasons for positive biological monitoring results in hydrogen peroxide low-temperature plasma sterilization and taking effective measures promptly can minimize associated risks.展开更多
[Objective] The aim was to study the explants sterilization and callus induction of Aquilegia oxysepala.[Method] the seeds of Aquilegia oxysepala were sterilized by different kinds and concentrations of disinfectants,...[Objective] The aim was to study the explants sterilization and callus induction of Aquilegia oxysepala.[Method] the seeds of Aquilegia oxysepala were sterilized by different kinds and concentrations of disinfectants,and the pollution rate and pollution speed were investigated so as to find the best way to build sterile seedling setup.Taking the roots,stem segments and leaves of the sterile seedlings from Aquilegia oxysepala seeds as explants,the optimum explants and medium were screened by adding MS basic medium with different hormone proportions.[Result] The best germicidal treatment was as follows:explants were soaked in 75% alcohol for 30 s firstly,washed by sterile water for 5 times,then soaked in 0.2% mercuric chloride liquid for 2 min,finally washed by sterile water for 5 times again.The sterilization treatment could get the lowest pollution rate,the highest germinating capacity and the best sterile seedling.Roots were the optimum explants for the callus induction of Aquilegia oxysepala,meanwhile the optimal medium was MS+0.6 mg/L 2,4-D+0.5 mg/L 6-BA.[Conclusion] The research provides technical support for the large scale production of Aquilegia oxysepala and also makes a contribution to the medicinal and ornamental value of Aquilegia oxysepala.展开更多
An aircraft cabin is a narrow,closed-space environment.To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning sy...An aircraft cabin is a narrow,closed-space environment.To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning system,called the ultra-high-temperature instantaneous sterilization air conditioning system(UHTACS),is proposed.Based on the proposed system,a simulation of the UHT-ACS is analysed in various flight states.In the UHT-ACS,the mixing air temperature of return and bleed air can reach temperature up to 148.8°C,which is high enough to kill bacilli and viruses in 2一8 s.The supply air temperature of the UHT-ACS in a mixing cavity is about 12 C in cooling mode both on the ground and in the air.The supply air temperature is about 42 C in heating mode.Compared with the air conditioning systems(ACS)of traditional aircraft the supply air temperatures of the UHT-ACS in the mixing cavity are in good agreement with those of a traditional ACS with 60%fresh air and 40%return air.Furthermore the air temperature at the turbine outlet of the UHT-ACS is higher than that of a traditional ACS which will help to reduce the risk of icing at the outlet.Therefore the UHT-ACS can operate normally in various flight states.展开更多
With the epidemic of the coronavirus disease(COVID-19) infection, AlGaN-based ultraviolet-C light emitting diodes(UVC-LEDs) have attracted widespread attention for their sterilization application. However, the sterili...With the epidemic of the coronavirus disease(COVID-19) infection, AlGaN-based ultraviolet-C light emitting diodes(UVC-LEDs) have attracted widespread attention for their sterilization application. However, the sterilization characters of high power integrated light sources(ILSs) haven’t been widely investigated before utilizing in public sanitary security. In this work,by integrating up to 195 UVC-LED chips, high power UVC-LED ILSs with a light output power(LOP) of 1.88 W were demonstrated. The UVC-LED ILSs were verified to have efficient and rapid sterilization capability, which have achieved more than99.9% inactivation rate of several common pathogenic microorganisms within 1 s. In addition, the corresponding air sterilization module based on them was also demonstrated to kill more than 97% of Staphylococcus albus in the air of 20 m3 confined room within 30 min. This work demonstrates excellent sterilization ability of UVC-LED ILSs with high LOP, revealing great potential of UVC-LEDs in sterilization applications in the future.展开更多
This paper reviewed the latest progress on the sterilization technology of medicinal flowers, and briefly introduced its principle and application. Compared with the traditional chemical sterilization and autoclave st...This paper reviewed the latest progress on the sterilization technology of medicinal flowers, and briefly introduced its principle and application. Compared with the traditional chemical sterilization and autoclave sterilization techniques, irradiation sterilization, light radiation sterilization and gas sterilization own their unique advan- tages for different drugs sterilization requirements, which are worth further promotion.展开更多
The sterilization of the simulated unearthed silk fabrics using an atmospheric pressure plasma jet(APPJ) system employing Ar/O2 or He/O2 plasma to inactivate the mycete attached on the silk fabrics is reported. The ...The sterilization of the simulated unearthed silk fabrics using an atmospheric pressure plasma jet(APPJ) system employing Ar/O2 or He/O2 plasma to inactivate the mycete attached on the silk fabrics is reported. The effects of the APPJ characteristics(particularly the gas type and discharge power) on the fabric strength, physical-chemical structures,and sterilizing efficiency were investigated. Experimental results showed that the Ar/O2 APPJ plasma can inactivate the mycete completely within 4.0 min under a discharge power of 50.0 W. Such an APPJ treatment had negligible impact on the mechanical strength of the fabric and the surface chemical characteristics. Moreover, the Ar ions, O and OH radicals were shown to play important roles on the sterilization of the mycete attached on the unearthed silk fabrics.展开更多
Non-convex methods play a critical role in low-rank tensor completion for their approximation to tensor rank is tighter than that of convex methods.But they usually cost much more time for calculating singular values ...Non-convex methods play a critical role in low-rank tensor completion for their approximation to tensor rank is tighter than that of convex methods.But they usually cost much more time for calculating singular values of large tensors.In this paper,we propose a double transformed tubal nuclear norm(DTTNN)to replace the rank norm penalty in low rank tensor completion(LRTC)tasks.DTTNN turns the original non-convex penalty of a large tensor into two convex penalties of much smaller tensors,and it is shown to be an equivalent transformation.Therefore,DTTNN could take advantage of non-convex envelopes while saving time.Experimental results on color image and video inpainting tasks verify the effectiveness of DTTNN compared with state-of-the-art methods.展开更多
Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues.Tissues like bone,skin,amniotic membrane and soft tissues obtained from human donor can be used for repa...Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues.Tissues like bone,skin,amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body.Allograft tissues from human donor provide an excellent alternative to autografts.However,major concern with the use of allografts is the risk of infectious disease transmission.Therefore,tissue allografts should be sterilized to make them safe for clinical use.Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues.This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts.展开更多
In this work, a Dielectric Barrier Discharge (DBD) air plasma was used to sterilize Escherichia eoli (E. coli) on the surface of medical Polyethylene Terephthalate (PET) film. The leakage of cellular DNA and pro...In this work, a Dielectric Barrier Discharge (DBD) air plasma was used to sterilize Escherichia eoli (E. coli) on the surface of medical Polyethylene Terephthalate (PET) film. The leakage of cellular DNA and protein by optical absorbance measurement at 260 nm and 280 nm, together with transmission electron microscopy (TEM) about cell morphology were performed after sterilization to analyse inactivation mechanisms. The results indicated that the DBD air plasma was very effective in E. coli sterilization. The plasma germicidal efficiency depended on the plasma treatment time, the air-gap distance, and the applied voltage. Within 5 min of plasma treatment, the germicidal efficiency against E. coli could reach 99.99%. An etching action on cell membranes by electrons, ions and radicals is the primary mechanism for DBD air plasma sterilization, which leads to the effusion of cellular contents (DNA and protein) and bacterial death.展开更多
文摘Objectives To study characteristics of psychosomatic symptoms related to sterilization, to find out risk factors and their roles ascribed to psychosomatic symptoms, and to establish a mathematic model for screening out susceptible women. Methods: This study enrolled 776 women in rural area at three counties of Linxiang, Qiyang, Changsha of Hunan province in China between February 1990 and April 1992. Brief Neurosis Screening Scale (BNSS), Symptom Checklist 90 (SCL-90), sensitivity to pain, suggestibility were used to indicate subjects' psychological status. Logistic regression model and retrograde discriminant analysis were applied to develop a mathematical model. Results: Prevalence of psychosomatic reactions or symptoms was 54.8% before sterilization, 26.6% at three months and 16.4% at one year after operation respectively. Psychosomatic symptoms were verified to be the result of joint effects of multiple risk factors. The following risk factors were associated with postoperative symptoms: anger-hostility (RR=33.71), high suggestibility (RR=4.53), high neuroticism (RR=3.44), sensitivity to pain (RR=2.14) and operative sites (RR=2.05). A mathematical model to estimate the probability of developing psychosomatic symptoms in sterilization was established.Conclusions: More than half of women suffered from psychosomatic reactions before operation, and some of them did not recover after operation. The postoperative psychosomatic symptoms are the joint effect of multiple risk factors.
文摘One thousand and twenty-nine women with microsurgical tubal reversal after tubal sterilization were followed up.The rate of intrauterine pregnancy was found to be 93.29%.The rate of intrauterine pregnancy was the highest(73.28%)in the first year after tubal reversal.In the first year,the chance of pregnancy in the first 6 months was higher (54.81%)than that(40.86%)in the second 6 months(P<0.01),and the chance in the first 3 months was higher(37.41%)than that(27.80%)in the second 3 months(P<0.01).The rates of ectopic pregnancy after tubal reversal in various stages were not significantly different(P>0.05).The rate of intrauterine pregnancy was not related with the period from sterilization to tubal reversal.Early postoperative hydropertubation can only decrease the rate of intrauterine pregnancy.The rate of intra uterine pregnancy of the tubal reversal after Uchida's method and clips tubal sterilization was higher than that after Pomeroy's tubal ligation.The reanastomosis of isthmus and isthmus resulted in the highest rate of intra uterine pregnancy,so we think that Uchida's or elips tubal sterilization in the isthmus of the tubal are ideal and reversible techniques at present.
文摘The present objective is to observe the side effects and complications of fem ale tubalsterilization by phenol-atabrinepaste (PAP) and phenolm ucilage (PM). 1 705 eligible w om en w ere divided random ly into tw o groups, 871 usinig PAP and 834 w om en using PM. Results: Thefeverratesw ere8.0and 4.4( P< 0.01 ) respec- tively in group PAP and group PM. Infection rates of the appendages w ere 2.3 and 1.2 respectively. The incidence of chem ical peritonitis, w ithin the lim its of pelvic cavity, w ere 1.1and 2.4respectively. Perforation of uterus, pelvic ab- scessand ectopicpregnancy w ere notfound during thisobservation. Slightabdom inal pain after the proceduresw ere 33.6and 30.8respectively. Slightvaginalbleed- ing after the procedure w as 23.2 and 18.0 respectively. Menstruation of the w om en w as not affected by the instillation. This five-year follow -up study neither show ed a positivePap testnor a potentialdeseasecaused by thesterilizing agents. This technique isa safe and efficientm ethod for fem ale sterilization.
文摘A multi center randomized clinical trial was adopted in the present study. 1705 eligible women with identical demographic and gynecological characteristics were divided into two groups: 871 using phenol atabrine paste (PAP) and 834 using phenol mucilage (PM). The five year follow up rates for the two groups were 97.5% and 98.1%, respectively. The multiple decrement life table analysis showed that there was a significant difference in the gross cumulative failure rates between the two groups. The 60th month gross cumulative failure rates for PAP group and PM group were 4.61% and 11.87%, respectively, thus indicating the efficacy of PAP to be significantly higher than that of PM. 97.7% users had cervical smear examinations, but no suspected cancer cells or cancer cells were found. Meanwhile, there was no known diseases related to the chemical reagent. This follow up study indicates that tubal sterilization by chemical instillation is a simple,safe and efficient female method. It suggested that this method would be introduced to a wider use on the basis of modification in the composition of chemical agents, standardized operational procedure, and improved administrative regulation in the use of this technology.
文摘Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.
文摘Tubal ligation or tubectomy (also known as having one's "tubes tied" (ligation)) is a surgical procedure for sterilization in which a woman's fallopian tubes are clamped and blocked, or severed and sealed, either method of which prevents eggs from
基金supported by National Natural Science Foundation of China(Nos.52077129 and 52277150)the Natural Science Foundation of Shandong Province(No.ZR2022ME037).
文摘Plasma sterilization is a new generation of high-tech sterilization method that is fast,safe,and pollution free.It is widely used in medical,food,and environmental protection fields.Home air sterilization is an emerging field of plasma application,which puts higher requirements on the miniaturization,operational stability,and operating cost of plasma device.In this study,a novel magnetically driven rotating gliding arc(MDRGA)discharge device was used to sterilize Lactobacillus fermentation.Compared with the traditional gas-driven gliding arc,this device has a simple structure and a more stable gliding arc.Simulation using COMSOL Multiphysics showed that adding permanent magnets can form a stable magnetic field,which is conducive to the formation of gliding arcs.Experiments on the discharge performance,ozone concentration,and sterilization effect were conducted using different power supply parameters.The results revealed that the MDRGA process can be divided into three stages:starting,gliding,and extinguishing.Appropriate voltage was the key factor for stable arc gliding,and both high and low voltages were not conducive to stable arc gliding and ozone production.In this experimental setup,the sterilization effect was the best at 6.6 kV.A high modulation duty ratio was beneficial for achieving stable arc gliding.However,when the duty ratio exceeded a certain value,the improvement in the sterilization effect was slow.Therefore,considering the sterilization effect and energy factors comprehensively,we chose 80%as the optimal modulation duty ratio for this experimental device.
基金supported by the National Natural Science Foundation of China(Nos.22176145,82172612)the State Key Laboratory of Fine Chemicals,Dalian University of Technology(KF 2001)the Fundamental Research Funds for the Central Universities(22120210137).
文摘The massive use of antibiotics has led to the aggravation of bacterial resistance and also brought environmental pollution problems.This poses a great threat to human health.If the dosage of antibiotics is reduced by increasing its bactericidal performance,the emergence of drug resistance is certainly delayed,so that there's not enough time for developing drug resistance during treatment.Therefore,we selected typical representative materials of metal Ag and semiconductor ZnO nano-bactericides to design and synthesize Ag/ZnO hollow core-shell structures(AZ for short).Antibiotics are grafted on the surface of AZ through rational modification to form a composite sterilization system.The research results show that the antibacterial efficiency of the composite system is significantly increased,from the sum(34.7%+22.8%-57.5%)of the antibacterial efficiency of AZ and gentamicin to 80.2%,net synergizes 22.7%,which fully reflects the effect of 1+1>2.Therefore,the dosage of antibiotics can be drastically reduced in this way,which makes both the possibility of bacterial resistance and medical expenses remarkably decrease.Subsequently,residual antibiotics can be degraded under simple illumination using AZ-self as a photocatalyst,which cuts off the path of environmental pollution.In short,such an innovative route has guiding significance for drug resistance.
基金supported by:the National Natural Science Foundation of China under Grant Nos.62163009 and 61864001the Natural Science Foundation of Guangxi Province under Grant No.2021JJD170019+1 种基金the Foundation of Guangxi Key Laboratory of Automatic Detecting Technology and Instruments(Guilin University of Electronic Technology)under Grant No.YQ23103the Innovation Project of Guangxi Graduate Education under Grant No.YCSW2022277.
文摘There is a currently a lack of large-area plasma sterilization devices that can intelligently identify the shape of a wound for automatic steriliza-tion.For this reason,in this work,a plasma sterilization device with wound-edge recognition was developed using afield-programmable gate array(FPGA)and a high-performance image-processing platform to realize intelligent and precise sterilization of wounds.SOLIDWORKS was used to design the mechanical structure of the device,and it was manufactured using 3D printing.The device used an improvement of the traditional Sobel detection algorithm,which extends the detection of edges in only the x and y directions to eight directions(0○,45○,90○,135○,180○,225○,270○,and 315○),completing the wound-edge detection by adaptive thresholding.The device can be controlled according to different shapes of sterilization area to adjust the positioning of a single plasma-jet tube in the horizontal plane for two-dimensional move-ment;the distance between the plasma-jet tube and the surface of the object to be sterilized can be also adjusted in the vertical direction.In this way,motors are used to move the plasma jet and achieve automatic,efficient,and accurate plasma sterilization.It was found that a good sterilization effect could be achieved at both the culture-medium level and the biological-tissue level.The ideal sterilization parameters at the culture-medium level were a speed of 2 mm/s and aflow rate of 0.6 slm,while at the biological-tissue level,these values were 1 mm/s and 0.6 slm,respectively.
文摘Guilin rice noodles, a unique cuisine from Guilin, Guangxi, is renowned both domestically and internationally as one of the top ten “Guilin Classics”. Utilizing a heat conduction model, this study explores the effectiveness of the cooking process in sterilizing Guilin rice noodles before consumption. The model assumes that a large pot is filled with boiling water which is maintained at a constant high temperature heat resource through continuous gentle heating. And the room temperature is set as the initial temperature for the preheating process and the final temperature for the cooling process. The objective is to assess whether the cooking process achieves satisfactory sterilization results. The temperature distribution function of rice noodle with time is analytically obtained using the separation of variables method in the three-dimensional cylindrical coordinate system. Meanwhile, the thermal diffusion coefficient of Guilin rice noodles is obtained in terms of Riedel’ theory. By analyzing the elimination characteristics of Pseudomonas cocovenenans subsp. farinofermentans, this study obtains the optimal time required for effective sterilization at the core of Guilin rice noodles. The results show that the potential Pseudomonas cocovenenans subsp. farinofermentans will be completely eliminated through continuously preheating more than 31 seconds during the cooking process before consumption. This study provides a valuable reference of food safety standards in the cooking process of Guilin rice noodles, particularly in ensuring the complete inactivation of potentially harmful strains such as Pseudomonas cocovenenans subsp. farinofermentans.
文摘Objective:This study aims to evaluate the application value of biological monitoring and different types of chemical indicator cards in batch monitoring of hydrogen peroxide low-temperature plasma sterilization.The goal is to standardize the selection of loading conditions for this sterilization method and avoid positive biological monitoring results.Methods:Physical monitoring,Class I chemical indicator card monitoring,Class IV chemical indicator card monitoring,and biological monitoring were used to monitor the hydrogen peroxide low-temperature plasma sterilization process.The sterilization effect on instruments inside the Johnson&Johnson 100S plasma sterilizer was monitored and the qualification of various monitoring methods was compared.Results:The comparison showed that when non-standard or adsorption-prone packaging materials were used,the interception rate of biological monitoring and Class IV chemical indicator cards was significantly higher than that of physical monitoring and Class I chemical indicator cards.These methods more intuitively and effectively detected sterilization failures.Conclusion:Biological monitoring and Class IV chemical indicator cards are safe,fast,accurate,and easy to interpret in hydrogen peroxide low-temperature plasma sterilization,especially for monitoring instruments inside packages.They provide a reliable basis for the release of sterilized instrument packages.Identifying the reasons for positive biological monitoring results in hydrogen peroxide low-temperature plasma sterilization and taking effective measures promptly can minimize associated risks.
基金Supported by the Fundamental Research Funds for the Central Universities(DL09BA16)Science Research Foundation for Young Scientists of northeast Forestry University(09047 )Graduate Project Technology Innovation Funds of Northeast Forestry University~~
文摘[Objective] The aim was to study the explants sterilization and callus induction of Aquilegia oxysepala.[Method] the seeds of Aquilegia oxysepala were sterilized by different kinds and concentrations of disinfectants,and the pollution rate and pollution speed were investigated so as to find the best way to build sterile seedling setup.Taking the roots,stem segments and leaves of the sterile seedlings from Aquilegia oxysepala seeds as explants,the optimum explants and medium were screened by adding MS basic medium with different hormone proportions.[Result] The best germicidal treatment was as follows:explants were soaked in 75% alcohol for 30 s firstly,washed by sterile water for 5 times,then soaked in 0.2% mercuric chloride liquid for 2 min,finally washed by sterile water for 5 times again.The sterilization treatment could get the lowest pollution rate,the highest germinating capacity and the best sterile seedling.Roots were the optimum explants for the callus induction of Aquilegia oxysepala,meanwhile the optimal medium was MS+0.6 mg/L 2,4-D+0.5 mg/L 6-BA.[Conclusion] The research provides technical support for the large scale production of Aquilegia oxysepala and also makes a contribution to the medicinal and ornamental value of Aquilegia oxysepala.
基金the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)and the Foundation of Jiangsu Postdoctoral(No.2019K126)。
文摘An aircraft cabin is a narrow,closed-space environment.To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning system,called the ultra-high-temperature instantaneous sterilization air conditioning system(UHTACS),is proposed.Based on the proposed system,a simulation of the UHT-ACS is analysed in various flight states.In the UHT-ACS,the mixing air temperature of return and bleed air can reach temperature up to 148.8°C,which is high enough to kill bacilli and viruses in 2一8 s.The supply air temperature of the UHT-ACS in a mixing cavity is about 12 C in cooling mode both on the ground and in the air.The supply air temperature is about 42 C in heating mode.Compared with the air conditioning systems(ACS)of traditional aircraft the supply air temperatures of the UHT-ACS in the mixing cavity are in good agreement with those of a traditional ACS with 60%fresh air and 40%return air.Furthermore the air temperature at the turbine outlet of the UHT-ACS is higher than that of a traditional ACS which will help to reduce the risk of icing at the outlet.Therefore the UHT-ACS can operate normally in various flight states.
基金supported by the Guangdong Basic and Application Basic Research Foundation of Guangdong Province (Nos. 2021A1515111149, 2021B1515120022, 2020B 010174003)。
文摘With the epidemic of the coronavirus disease(COVID-19) infection, AlGaN-based ultraviolet-C light emitting diodes(UVC-LEDs) have attracted widespread attention for their sterilization application. However, the sterilization characters of high power integrated light sources(ILSs) haven’t been widely investigated before utilizing in public sanitary security. In this work,by integrating up to 195 UVC-LED chips, high power UVC-LED ILSs with a light output power(LOP) of 1.88 W were demonstrated. The UVC-LED ILSs were verified to have efficient and rapid sterilization capability, which have achieved more than99.9% inactivation rate of several common pathogenic microorganisms within 1 s. In addition, the corresponding air sterilization module based on them was also demonstrated to kill more than 97% of Staphylococcus albus in the air of 20 m3 confined room within 30 min. This work demonstrates excellent sterilization ability of UVC-LED ILSs with high LOP, revealing great potential of UVC-LEDs in sterilization applications in the future.
文摘This paper reviewed the latest progress on the sterilization technology of medicinal flowers, and briefly introduced its principle and application. Compared with the traditional chemical sterilization and autoclave sterilization techniques, irradiation sterilization, light radiation sterilization and gas sterilization own their unique advan- tages for different drugs sterilization requirements, which are worth further promotion.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11665005,11505032,11547139,51672249,and 11565003)the Zhejiang Natural Science Foundation of China(Grant No.LY16A050002)+3 种基金the Natural Science Foundation of Jiangxi Province,China(Grant Nos.20161BAB211026,20171ACB21049,and 20171BAB211012)the Science and Technology Project of Jiangxi Provincial Department of Education,China(Grant No.GJJ150981)the Program for Innovative Research Team of Zhejiang Sci-Tech University,Chinathe Opening Foundation of Insititue of Textile Technology,Wuhan Texitle Universitiy,China(Grant No.GCZX201702)
文摘The sterilization of the simulated unearthed silk fabrics using an atmospheric pressure plasma jet(APPJ) system employing Ar/O2 or He/O2 plasma to inactivate the mycete attached on the silk fabrics is reported. The effects of the APPJ characteristics(particularly the gas type and discharge power) on the fabric strength, physical-chemical structures,and sterilizing efficiency were investigated. Experimental results showed that the Ar/O2 APPJ plasma can inactivate the mycete completely within 4.0 min under a discharge power of 50.0 W. Such an APPJ treatment had negligible impact on the mechanical strength of the fabric and the surface chemical characteristics. Moreover, the Ar ions, O and OH radicals were shown to play important roles on the sterilization of the mycete attached on the unearthed silk fabrics.
基金financially supported by the National Nautral Science Foundation of China(No.61703206)
文摘Non-convex methods play a critical role in low-rank tensor completion for their approximation to tensor rank is tighter than that of convex methods.But they usually cost much more time for calculating singular values of large tensors.In this paper,we propose a double transformed tubal nuclear norm(DTTNN)to replace the rank norm penalty in low rank tensor completion(LRTC)tasks.DTTNN turns the original non-convex penalty of a large tensor into two convex penalties of much smaller tensors,and it is shown to be an equivalent transformation.Therefore,DTTNN could take advantage of non-convex envelopes while saving time.Experimental results on color image and video inpainting tasks verify the effectiveness of DTTNN compared with state-of-the-art methods.
文摘Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues.Tissues like bone,skin,amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body.Allograft tissues from human donor provide an excellent alternative to autografts.However,major concern with the use of allografts is the risk of infectious disease transmission.Therefore,tissue allografts should be sterilized to make them safe for clinical use.Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues.This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts.
文摘In this work, a Dielectric Barrier Discharge (DBD) air plasma was used to sterilize Escherichia eoli (E. coli) on the surface of medical Polyethylene Terephthalate (PET) film. The leakage of cellular DNA and protein by optical absorbance measurement at 260 nm and 280 nm, together with transmission electron microscopy (TEM) about cell morphology were performed after sterilization to analyse inactivation mechanisms. The results indicated that the DBD air plasma was very effective in E. coli sterilization. The plasma germicidal efficiency depended on the plasma treatment time, the air-gap distance, and the applied voltage. Within 5 min of plasma treatment, the germicidal efficiency against E. coli could reach 99.99%. An etching action on cell membranes by electrons, ions and radicals is the primary mechanism for DBD air plasma sterilization, which leads to the effusion of cellular contents (DNA and protein) and bacterial death.