The objective of this study is to develop an analytical methodology to evaluate the effectiveness of vibro stone column (S.C.) and dynamic compaction (D.C.) techniques supplemented with wick drains to densify and miti...The objective of this study is to develop an analytical methodology to evaluate the effectiveness of vibro stone column (S.C.) and dynamic compaction (D.C.) techniques supplemented with wick drains to densify and mitigate liquefaction in saturated sands and non-plastic silty soils. It includes the following: (i) develop numerical models to simulate and analyze soil densitication during S.C. installation and D.C. process, and (ii) identify parameters controlling post-improvement soil density in both cases, and (iii) develop design guidelines for densification of silty soils using the above techniques. An analytical procedure was developed and used to simulate soil response during S.C. and D.C. installations, and the results were compared with available case history data. Important construction design parameters and soil properties that affect the effectiveness of these techniques, and construction design choices suitable for sands and non-plastic silty soils were identified. The methodology is expected to advance the use of S.C. and D.C. in silty soils reducing the reliance on expensive field trials as a design tool. The ultimate outcome of this research will be design charts and design guidelines for using composite stone columns and composite dynamic compaction techniques in liquefaction mitigation of saturated silty soils.展开更多
The shaking table model test was conducted to investigate earthquake resistant behavior of stone columns under the intensity of an earthquake resistance of buildings is VIII. The test results show that when accelerati...The shaking table model test was conducted to investigate earthquake resistant behavior of stone columns under the intensity of an earthquake resistance of buildings is VIII. The test results show that when acceleration is less than 0.20 g, composite foundation is not liquefied, settlement is also small and pile dislocation is not observed; when acceleration is 0.3g, ground outside embankment's slope toe is liquefied and ground within stone column composite foundation is not. It is suggesting that reinforcement scale of stone column foundation should be widened properly. The designed stone column composite foundation meets the requirements for seismic resistance.展开更多
基金Federal Highway Administration(FHWA)Under Grant No.DTFH61-98-C-0094
文摘The objective of this study is to develop an analytical methodology to evaluate the effectiveness of vibro stone column (S.C.) and dynamic compaction (D.C.) techniques supplemented with wick drains to densify and mitigate liquefaction in saturated sands and non-plastic silty soils. It includes the following: (i) develop numerical models to simulate and analyze soil densitication during S.C. installation and D.C. process, and (ii) identify parameters controlling post-improvement soil density in both cases, and (iii) develop design guidelines for densification of silty soils using the above techniques. An analytical procedure was developed and used to simulate soil response during S.C. and D.C. installations, and the results were compared with available case history data. Important construction design parameters and soil properties that affect the effectiveness of these techniques, and construction design choices suitable for sands and non-plastic silty soils were identified. The methodology is expected to advance the use of S.C. and D.C. in silty soils reducing the reliance on expensive field trials as a design tool. The ultimate outcome of this research will be design charts and design guidelines for using composite stone columns and composite dynamic compaction techniques in liquefaction mitigation of saturated silty soils.
文摘The shaking table model test was conducted to investigate earthquake resistant behavior of stone columns under the intensity of an earthquake resistance of buildings is VIII. The test results show that when acceleration is less than 0.20 g, composite foundation is not liquefied, settlement is also small and pile dislocation is not observed; when acceleration is 0.3g, ground outside embankment's slope toe is liquefied and ground within stone column composite foundation is not. It is suggesting that reinforcement scale of stone column foundation should be widened properly. The designed stone column composite foundation meets the requirements for seismic resistance.