The experimental results of the thermal conductivities of xonotlite-type calcium silicate insulation materials were presented at different temperatures and pressures. Two appropriative surroundings, i.e. an elevated t...The experimental results of the thermal conductivities of xonotlite-type calcium silicate insulation materials were presented at different temperatures and pressures. Two appropriative surroundings, i.e. an elevated temperature surrounding from ambient temperature to 1450 K and a vacuum surrounding from atmosphere pressure to 10-3 Pa, were designed for the transient hot-strip (THS) method. The thermal conductivities of xonotlite-type calcium silicate with four densities from ambient temperature to 1000 K and 0.045 Pa to atmospheric pressure were measured. The results show that the thermal conductivity of xonotlite-type calcium silicate decreases apparently with the fall of density, and decreases apparently with the drop of pressure, and reaches the least value at about 100 Pa. The thermal conductivity of xonotlite-type calcium silicate increases almost linearly with T0, and increases more abundantly with low density than with high density. The thermal conductivity measurement uncertainty is estimated to be approximately 3% at ambient temperature, and 6% at 800 K.展开更多
Porcine cimovirus type 2 (PCV2) infection causes huge economic losses, but no serological method is available for batch detection of field samples. The aim of the study was to develop a method for large-batch detectio...Porcine cimovirus type 2 (PCV2) infection causes huge economic losses, but no serological method is available for batch detection of field samples. The aim of the study was to develop a method for large-batch detection of PCV2 infection. Colloidal gold-labeled staphylococcal protein A (SPA) was sprayed on glass fibers to prepare a conjugate pad. The recombinant ORF2 protein of PCV2 was blotted on the test line of the nitrocellulose (NC) membrane, and pig IgG was streaked on the control line of the NC membrane. Then, the immunochromatographic strip was used for detection of antibodies against PCV2. The results show that the strip test was simple and the results could be determined within 10 min with naked eyes. The test strip was highly specific for pig serum against PCV2 and no cross-reaction with pig serum against other pathogens was observed. The test strip had close similarity with ELISA. Storage at RT for 6 months did not affect the specificity and sensitivity obviously. A total of 324 clinical pig sera were detected by both ELISA and the developed test strip, and the coincidence was 98.77%. Therefore, the developed immunochromatographic strip is specific, sensitive, stable, fast and simple, and it is suitable for on-site detection of antibodies against PCV2.展开更多
LPCNi 3.55 Co 0.75 Mn 0.4 Al 0.3 hydrogen storage alloy was investigated, and the effects of thickness of its strip casting ingots(as cast) on the electrochemical performances were discussed. It was ...LPCNi 3.55 Co 0.75 Mn 0.4 Al 0.3 hydrogen storage alloy was investigated, and the effects of thickness of its strip casting ingots(as cast) on the electrochemical performances were discussed. It was found that the 0.2 C discharge capacity increased with the increase of the thickness (from 1 mm to 10 mm) of the ingots, mainly due to the enlargement of the unit cell volume; Among the thickness of the ingots in our study, 10 mm sample showed a better activation property; LPCNi 3.55 Co 0.75 Mn 0.4 Al 0.3 alloy with 10mm showed higher comprehensive properties than those with other thickness under 1C rate.展开更多
The effect of thickness (1 similar to 10 mm) of the ingots on the electrochemical properties of as-cast and annealed strip cast LPCNi3.55Co0.75Mn0.4Al0.3 hydrogen storage alloys was investigated. It is found that the ...The effect of thickness (1 similar to 10 mm) of the ingots on the electrochemical properties of as-cast and annealed strip cast LPCNi3.55Co0.75Mn0.4Al0.3 hydrogen storage alloys was investigated. It is found that the 0.2 C discharge capacity of as-cast LPCNi3.55Co0.75Mn0.4Al0.3 alloy increases with the increase of the thickness of the ingots. As-east alloy with the thickness of 10 mm shows better activation property, higher 1C discharge capacity and better cyclic stability than others. It is mainly contributed to its larger unit cell volume and less internal stress. Annealed LPCNi3.55Co0.75Mn0.4Al0.3 alloy with the thickness of 3 mm shows much better comprehensive electrochemical properties than as-east one; The cyclic. stability of the alloy with the thickness of 6 mm and the activation properties of the alloys with the thickness of 3 similar to 6 mm are improved after annealing. It is mainly owing to the great release of internal stress and the decrease of the segregation of Mn in the alloys.展开更多
基金supported by the National Natural Science Foundation of China (No.50806021)
文摘The experimental results of the thermal conductivities of xonotlite-type calcium silicate insulation materials were presented at different temperatures and pressures. Two appropriative surroundings, i.e. an elevated temperature surrounding from ambient temperature to 1450 K and a vacuum surrounding from atmosphere pressure to 10-3 Pa, were designed for the transient hot-strip (THS) method. The thermal conductivities of xonotlite-type calcium silicate with four densities from ambient temperature to 1000 K and 0.045 Pa to atmospheric pressure were measured. The results show that the thermal conductivity of xonotlite-type calcium silicate decreases apparently with the fall of density, and decreases apparently with the drop of pressure, and reaches the least value at about 100 Pa. The thermal conductivity of xonotlite-type calcium silicate increases almost linearly with T0, and increases more abundantly with low density than with high density. The thermal conductivity measurement uncertainty is estimated to be approximately 3% at ambient temperature, and 6% at 800 K.
文摘Porcine cimovirus type 2 (PCV2) infection causes huge economic losses, but no serological method is available for batch detection of field samples. The aim of the study was to develop a method for large-batch detection of PCV2 infection. Colloidal gold-labeled staphylococcal protein A (SPA) was sprayed on glass fibers to prepare a conjugate pad. The recombinant ORF2 protein of PCV2 was blotted on the test line of the nitrocellulose (NC) membrane, and pig IgG was streaked on the control line of the NC membrane. Then, the immunochromatographic strip was used for detection of antibodies against PCV2. The results show that the strip test was simple and the results could be determined within 10 min with naked eyes. The test strip was highly specific for pig serum against PCV2 and no cross-reaction with pig serum against other pathogens was observed. The test strip had close similarity with ELISA. Storage at RT for 6 months did not affect the specificity and sensitivity obviously. A total of 324 clinical pig sera were detected by both ELISA and the developed test strip, and the coincidence was 98.77%. Therefore, the developed immunochromatographic strip is specific, sensitive, stable, fast and simple, and it is suitable for on-site detection of antibodies against PCV2.
文摘LPCNi 3.55 Co 0.75 Mn 0.4 Al 0.3 hydrogen storage alloy was investigated, and the effects of thickness of its strip casting ingots(as cast) on the electrochemical performances were discussed. It was found that the 0.2 C discharge capacity increased with the increase of the thickness (from 1 mm to 10 mm) of the ingots, mainly due to the enlargement of the unit cell volume; Among the thickness of the ingots in our study, 10 mm sample showed a better activation property; LPCNi 3.55 Co 0.75 Mn 0.4 Al 0.3 alloy with 10mm showed higher comprehensive properties than those with other thickness under 1C rate.
文摘The effect of thickness (1 similar to 10 mm) of the ingots on the electrochemical properties of as-cast and annealed strip cast LPCNi3.55Co0.75Mn0.4Al0.3 hydrogen storage alloys was investigated. It is found that the 0.2 C discharge capacity of as-cast LPCNi3.55Co0.75Mn0.4Al0.3 alloy increases with the increase of the thickness of the ingots. As-east alloy with the thickness of 10 mm shows better activation property, higher 1C discharge capacity and better cyclic stability than others. It is mainly contributed to its larger unit cell volume and less internal stress. Annealed LPCNi3.55Co0.75Mn0.4Al0.3 alloy with the thickness of 3 mm shows much better comprehensive electrochemical properties than as-east one; The cyclic. stability of the alloy with the thickness of 6 mm and the activation properties of the alloys with the thickness of 3 similar to 6 mm are improved after annealing. It is mainly owing to the great release of internal stress and the decrease of the segregation of Mn in the alloys.