期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
A simulation study of a windowless gas-stripping room in an E//B neutral particle analyzer 被引量:1
1
作者 Yuan Luo Wei-Ping Lin +9 位作者 Pei-Pei Ren Guo-Feng Qu Jing-Jun Zhu Xing-Quan Liu Xiao-Bing Luo Zhu An Roy Wada Lin-Ge Zang Yu-Fan Qu Zhong-Bing Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第7期22-30,共9页
The neutral particle analyzer(NPA)is one of the crucial diagnostic devices in a Tokamak facility.The stripping unit is one of the main parts of the NPA.A windowless gas-stripping room with two differential pipes has b... The neutral particle analyzer(NPA)is one of the crucial diagnostic devices in a Tokamak facility.The stripping unit is one of the main parts of the NPA.A windowless gas-stripping room with two differential pipes has been constructed in a parallel electric and magnetic fields(E//B)NPA.The pressure distributions in the stripping chamber are simulated by ANSYS Fluent together with MolFlow+.Based on the pressure distributions obtained from the simulation,the stripping efficiency of the E//B NPA is studied using GEANT4.Hadron reaction physics is modified to track the charge state of each particle in a cross-section-based method in GEANT4.The transmission rates(R)and stripping efficiencies f_(+1)are examined for particle energies ranging from 20 to 200 keV with the input pressure(P_(0)),ranging from 20 to 400 Pa.According to the combined global efficiency,R×f_(+1),P_(0)=240 Pa is obtained as the optimum pressure for the maximum global efficiency in the incident energy range investigated. 展开更多
关键词 Neutral particle analyzer Windowless gas-stripping chamber stripping efficiency Ansys Fluent MolFlow+ GEANT4
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部