Software synchronous sampling is widely employed in periodic signal measurement, but measurement errors occur very commonly. This paper analyses the cause of the errors, deduces the mathematical model for the measure...Software synchronous sampling is widely employed in periodic signal measurement, but measurement errors occur very commonly. This paper analyses the cause of the errors, deduces the mathematical model for the measurement errors in measuring RMS voltage, RMS current and active power using the software synchronous sampling method. Some measures to reduce the errors are put forward by simulating.展开更多
As far as the vibration signal processing is concerned, composition ofvibration signal resulting from incipient localized faults in gearbox is too weak to be detected bytraditional detecting technology available now. ...As far as the vibration signal processing is concerned, composition ofvibration signal resulting from incipient localized faults in gearbox is too weak to be detected bytraditional detecting technology available now. The method, which includes two steps: vibrationsignal from gearbox is first processed by synchronous average sampling technique and then it isanalyzed by complex continuous wavelet transform to diagnose gear fault, is introduced. Twodifferent kinds of faults in the gearbox, i.e. shaft eccentricity and initial crack in tooth fillet,are detected and distinguished from each other successfully.展开更多
Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the proble...Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system,an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop(PLL)is built,and a high-precision synchronous sampling method is proposed,which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock.Based on the improved synchronous sampling model,the influence of clock stability,transmission delay and phase jitter on synchronous sampling error is analyzed,and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed.The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle,and compensate the influence of signal transmission delay on synchronous sampling error.At the same time,it greatly reduces the complexity of software and hardware implementation of synchronous sampling,and solves the problem of long locking time after changing the sampling rate in traditional methods.The experimental system of synchronous sampling for dual linear array is built,and the synchronous sampling accuracy is better than 5 ns.展开更多
In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling techniqu...In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks.展开更多
The China Seismo-Electromagnetic Satellite(CSES)deploys three payloads to detect the electromagnetic environment in the ionosphere.The tri-axial fluxgate magnetometers(FGM),as part of the high precision magnetometer(H...The China Seismo-Electromagnetic Satellite(CSES)deploys three payloads to detect the electromagnetic environment in the ionosphere.The tri-axial fluxgate magnetometers(FGM),as part of the high precision magnetometer(HPM),measures the Earth magnetic vector field in a frequency range from direct current(DC)to 15 Hz.The tri-axial search coil magnetometer(SCM)detects the alternating current(AC)related magnetic field in a frequency range from several Hz to 20 k Hz,and the electric field detector(EFD)measures the spatial electric field in a broad frequency band from DC to 3.5 MHz.This work mainly crosscalibrates the consistency of these three payloads in their overlapped detection frequency range and firstly evaluates CSES’s timing system and the sampling time differences between EFD and SCM.A sampling time synchronization method for EFD and SCM waveform data is put forward.The consistency between FGM and SCM in the ultra-low-frequency(ULF)range is validated by using the magnetic torque(MT)signal as a reference.A natural quasiperiodic electromagnetic wave event verifies SCM and EFD’s consistency in extremely low-frequency and very low-frequency(ELF/VLF)bands.This cross-calibration work is helpful to upgrade the data quality of CSES and brings valuable insights to similar electromagnetic detection solutions by low earth orbit satellites.展开更多
Utilizing shaft-speed information to analyse vibration signals is an important method for fault diagnosis and condition monitoring of rotating machineries,especially for those running at variable speeds.However,in man...Utilizing shaft-speed information to analyse vibration signals is an important method for fault diagnosis and condition monitoring of rotating machineries,especially for those running at variable speeds.However,in many cases,shaft-speed information is not always available,for a variety of reasons.Fortunately,in most of the measurements,the shaft-speed information is embedded in the vibration response in many different forms,such as in the format of the fundamental shaft-rotation-frequency response and its harmonics,and the gear-meshing-frequency response and its harmonics,etc.Proper signal processing can be used to extract the shaft instantaneous speed from the measured vibration responses.In existing instantaneous shaft-speed-identification methods,a narrow-bandpass filtering technique is used explicitly or implicitly.In a complex gearbox system,such as that used in a wind turbine,the gear-meshing-response component could be modulated by many other shaft speeds,due to the configuration of the gearbox or due to the existence of component damage.As a result,it is very difficult to isolate a single vibration-response component for instantaneous shaft-speed detection.In this paper,an innovative approach is presented.The instantaneous shaft speed is extracted based on maxima tracking from the vibration-response spectrogram.A numerical integration scheme is employed to obtain the shaft instantaneous phase.Digital-domain synchronous resampling is then applied to the vibration data by using the instantaneous phase information.Due to the nature of noise suppression in the numerical integration,the accuracy of synchronous sampling is greatly improved.This proposed approach demonstrates the feasibility and engineering applicability through a controlled laboratory test case and two field wind-turbine cases.More detailed results and conclusions of this research are presented at the end of this paper.展开更多
文摘Software synchronous sampling is widely employed in periodic signal measurement, but measurement errors occur very commonly. This paper analyses the cause of the errors, deduces the mathematical model for the measurement errors in measuring RMS voltage, RMS current and active power using the software synchronous sampling method. Some measures to reduce the errors are put forward by simulating.
基金Provicial Natural Science Foundation of Shanxi,China(No.991051)Provincial Foundation for Homecoming Personnel from Study Abroad of Shanxi,China(No.194-101005)
文摘As far as the vibration signal processing is concerned, composition ofvibration signal resulting from incipient localized faults in gearbox is too weak to be detected bytraditional detecting technology available now. The method, which includes two steps: vibrationsignal from gearbox is first processed by synchronous average sampling technique and then it isanalyzed by complex continuous wavelet transform to diagnose gear fault, is introduced. Twodifferent kinds of faults in the gearbox, i.e. shaft eccentricity and initial crack in tooth fillet,are detected and distinguished from each other successfully.
基金National Key Research and Development Program of China(No.2018YFE0208200)National Natural Science Foundation of China(Nos.61971307,61905175,51775377)+5 种基金National Key Research and Development Plan Project(No.2020YFB2010800)The Fok Ying Tung Education Foundation(No.171055)China Postdoctoral Science Foundation(No.2020M680878)Guangdong Province Key Research and Development Plan Project(No.2020B0404030001)Tianjin Science and Technology Plan Project(No.20YDTPJC01660)Project of Foreign Affairs Committee of China Aviation Development Sichuan Gas Turbine Research Institute(Nos.GJCZ-2020-0040,GJCZ-2020-0041)。
文摘Synchronous sampling is very essential in underwater multilinear array seismic exploration system in which every acquisition node(AN)samples analog signals by its own analog-digital converter(ADC).Aiming at the problems of complex synchronous sampling method and long locking time after varying sampling rate in traditional underwater seismic exploration system,an improved synchronous sampling model based on the master-slave synchronous model and local clock asynchronous drive with non phase locked loop(PLL)is built,and a high-precision synchronous sampling method is proposed,which combines the short-term stability of local asynchronous driving clock with the master-slave synchronous calibration of local sampling clock.Based on the improved synchronous sampling model,the influence of clock stability,transmission delay and phase jitter on synchronous sampling error is analyzed,and a high-precision calibration method of synchronous sampling error based on step-by-step compensation of transmission delay is proposed.The model and method effectively realize the immunity of phase jitter on synchronous sampling error in principle,and compensate the influence of signal transmission delay on synchronous sampling error.At the same time,it greatly reduces the complexity of software and hardware implementation of synchronous sampling,and solves the problem of long locking time after changing the sampling rate in traditional methods.The experimental system of synchronous sampling for dual linear array is built,and the synchronous sampling accuracy is better than 5 ns.
文摘In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks.
基金supported by the National Natural Science Foundation of China(Grant Nos.41874174 and 41574139)the National Key R&D Program of China(Grant No.2018YFC1503501)+1 种基金the APSCO Earthquake Research Project PhaseⅡand ISSI-BJ projectSouthern Yunnan Observatory for Cross-block Dynamic Process,Yuxi Yunnan,China。
文摘The China Seismo-Electromagnetic Satellite(CSES)deploys three payloads to detect the electromagnetic environment in the ionosphere.The tri-axial fluxgate magnetometers(FGM),as part of the high precision magnetometer(HPM),measures the Earth magnetic vector field in a frequency range from direct current(DC)to 15 Hz.The tri-axial search coil magnetometer(SCM)detects the alternating current(AC)related magnetic field in a frequency range from several Hz to 20 k Hz,and the electric field detector(EFD)measures the spatial electric field in a broad frequency band from DC to 3.5 MHz.This work mainly crosscalibrates the consistency of these three payloads in their overlapped detection frequency range and firstly evaluates CSES’s timing system and the sampling time differences between EFD and SCM.A sampling time synchronization method for EFD and SCM waveform data is put forward.The consistency between FGM and SCM in the ultra-low-frequency(ULF)range is validated by using the magnetic torque(MT)signal as a reference.A natural quasiperiodic electromagnetic wave event verifies SCM and EFD’s consistency in extremely low-frequency and very low-frequency(ELF/VLF)bands.This cross-calibration work is helpful to upgrade the data quality of CSES and brings valuable insights to similar electromagnetic detection solutions by low earth orbit satellites.
文摘Utilizing shaft-speed information to analyse vibration signals is an important method for fault diagnosis and condition monitoring of rotating machineries,especially for those running at variable speeds.However,in many cases,shaft-speed information is not always available,for a variety of reasons.Fortunately,in most of the measurements,the shaft-speed information is embedded in the vibration response in many different forms,such as in the format of the fundamental shaft-rotation-frequency response and its harmonics,and the gear-meshing-frequency response and its harmonics,etc.Proper signal processing can be used to extract the shaft instantaneous speed from the measured vibration responses.In existing instantaneous shaft-speed-identification methods,a narrow-bandpass filtering technique is used explicitly or implicitly.In a complex gearbox system,such as that used in a wind turbine,the gear-meshing-response component could be modulated by many other shaft speeds,due to the configuration of the gearbox or due to the existence of component damage.As a result,it is very difficult to isolate a single vibration-response component for instantaneous shaft-speed detection.In this paper,an innovative approach is presented.The instantaneous shaft speed is extracted based on maxima tracking from the vibration-response spectrogram.A numerical integration scheme is employed to obtain the shaft instantaneous phase.Digital-domain synchronous resampling is then applied to the vibration data by using the instantaneous phase information.Due to the nature of noise suppression in the numerical integration,the accuracy of synchronous sampling is greatly improved.This proposed approach demonstrates the feasibility and engineering applicability through a controlled laboratory test case and two field wind-turbine cases.More detailed results and conclusions of this research are presented at the end of this paper.