A rapid method of determination of BaP in various environmental samples,using synchronous fluorescence spectroscopy scanning in defined range of dual-wavelengths(SFDW)is described in this paper.
A sensitive analytical method, constant-energy synchronous fluorimetry, has been used to determine benzo[a]pyrene (BaP) selectively in airborne particulates (AP). A constant-energy difference of 1 400 cm^-1 was se...A sensitive analytical method, constant-energy synchronous fluorimetry, has been used to determine benzo[a]pyrene (BaP) selectively in airborne particulates (AP). A constant-energy difference of 1 400 cm^-1 was selected for obtaining single spectral peak. The method could easily identify BaP in an 18-component polycylic aromatic hydrocarbons(PAHs) mixtures. Calibration plots in methanol solution and in sodium dodecylsulfate (SDS) micellar media show a good linearity (R〉0.999) in the BaP concentration range generally fotund in the environment. The method gives a detection limit of 0.40 nmol/L in SDS micellar medium and 1.34 nmol/L in methanol solution.展开更多
Constant-energy synchronous fluorimetry was used for the identification of benzo[a]pyrene in mixtures with a detection limit of 1.34 nmol/L. The recovery experiments in cigarette smoke samples have also obtained satis...Constant-energy synchronous fluorimetry was used for the identification of benzo[a]pyrene in mixtures with a detection limit of 1.34 nmol/L. The recovery experiments in cigarette smoke samples have also obtained satisfactory results of 99.1-103.5% for benzo[a]pyrene.展开更多
文摘A rapid method of determination of BaP in various environmental samples,using synchronous fluorescence spectroscopy scanning in defined range of dual-wavelengths(SFDW)is described in this paper.
基金Supported by the Natural Science Foundation of Fujian Province (D0410027)
文摘A sensitive analytical method, constant-energy synchronous fluorimetry, has been used to determine benzo[a]pyrene (BaP) selectively in airborne particulates (AP). A constant-energy difference of 1 400 cm^-1 was selected for obtaining single spectral peak. The method could easily identify BaP in an 18-component polycylic aromatic hydrocarbons(PAHs) mixtures. Calibration plots in methanol solution and in sodium dodecylsulfate (SDS) micellar media show a good linearity (R〉0.999) in the BaP concentration range generally fotund in the environment. The method gives a detection limit of 0.40 nmol/L in SDS micellar medium and 1.34 nmol/L in methanol solution.
基金We thank the Natural Science Foundation of Fujian Province for the financial supports(No.D0410027).
文摘Constant-energy synchronous fluorimetry was used for the identification of benzo[a]pyrene in mixtures with a detection limit of 1.34 nmol/L. The recovery experiments in cigarette smoke samples have also obtained satisfactory results of 99.1-103.5% for benzo[a]pyrene.