Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese...Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese subjects, those with secondary hypertension or resistant, diabetics, subjects with metabolic syndrome or sleep apnea syndrome. The objective of this study was to evaluate the contribution of ABPM in the diagnosis and evaluation of the level of control of hypertension under treatment at the Bel Air international clinic. Materials and Methods: This is a retrospective, cross-sectional and descriptive study, carried out at the Bel Air International Clinic in Conakry (Guinea) between January 2019 and November 30, 2022. It included a consecutive series of 180 consenting patients recruited through an ambulatory measurement of 24-hour blood pressure from a FUGADA brand device. Results: We collected 180 patients, with a male predominance (sex-ratio M/F = 2.46). The mean age of the patients was 48.48 ± 14.23 years. The most represented age group was that of 32 to 42 years with 50 cases (27.8%) followed by that of 43 to 52 years with 42 cases or 23.3%. The indication was for diagnostic purposes in 106 cases 58.9%, the therapeutic evaluation in 58 patients (32.2%). The examination was prescribed by a cardiologist in 98 cases (54.4%), a general practitioner in 71 cases (39.4%), a neurologist in 11 cases (6.1%). In the therapeutic evaluation, high blood pressure was controlled in 24 patients (13.3%) and uncontrolled in 34 cases (18.9%). In the diagnostic indication, high blood pressure was confirmed in 79 cases (43.9%) with a statistically significant link (Chi2</sup> = 4.57 and p-value = 0.032). The nycthemeral mean was 187.27 ± 26.22 mmHg for systolic blood pressure (SBP) and 110.37 ± 19.06 mmHg for diastolic blood pressure (DBP), during the day, 151.64 ± 21.45 mmHg for SBP and 71.59 ± 8.67 mmHg for diastolic blood pressure. During the study 65 patients (36.1%) were identified as dippers and 115 patients (63.9%) were no-dipping. The antihypertensive protocol used was monotherapy in 68 cases (37.8%), dual therapy in 46 cases (25.6%), triple therapy in 17 cases (9.4%). However 39 patients or 21.7% were not taking any antihypertensive. Conclusion: This preliminary study, despite the modest sample size, showed the importance of ABPM as a tool for diagnosis, monitoring of hypertensive patients and therapeutic adaptation. A large-scale national study would be necessary for the rational use of ambulatory blood pressure measurement in our context in order to improve the management of hypertensive patients.展开更多
Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hy...Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hypertensive patients led us to study the knowledge, compliance and effect of HDMs among Cameroonian hypertensive patients. Methods: This was a cross-sectional study carried out at the Douala General Hospital;the census of patients was carried out from 05 March to 10 May 2018. The data evaluated were knowledge and compliance with HDMs with an inference of their effect on blood pressure control. Results: We recruited 330 participants at mean age of 60 ± 11 years, 37.9% men;57.3% with blood pressure (BP) controlled. Out of 330 subjects, 308 (93.3%) who had been educated about dietary health measures for hypertension were assessed on knowledge, compliance and effect of these measures against 22 (6.7%) who had never heard about them. Around 85.7% of participants had good knowledge of HDMs and 78.9% had good compliance with them. There was no statistically significant influence of knowledge and compliance with HDMs on blood pressure control. Conclusion: The level of knowledge and adherence to HDMs of hypertensive patients at the Douala General Hospital was appreciable. It is however appropriate for physicians to intensify patient education on HDMs and BP control.展开更多
In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic...In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic BP (SBP) and the diastolic BP (DBP) fluctuated a large amount even though they were measured at a short interval. The first measurements were 6.7 and 2.4 mmHg higher than the second ones for SBP and DBP, suggesting a white coat effect. Then, the factors that might affect the differences between the two measurements were analyzed by the regression models. For both SBP and DBP, the difference increased as the first measurement increased. Age, gender, BMI and alcohol consumption were other important factors affecting the difference. In the case of a typical male individual, the typical criteria for hypertension of 140/90, 160/100 and 180/110 mmHg criteria in the first measurement would correspond to 135/86, 150/94 and 165/102 mmHg in the second measurement. The necessity of developing accurate and cost-efficient BP measurement methods is strongly suggested.展开更多
An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy...An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element(FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement.展开更多
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood ...This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators.The proposed platform measured the signal changes in PPG and converted them into physiological indicators,such as pulse transit time(PTT),pulse wave velocity(PWV),perfusion index(PI)and heart rate(HR);these indicators were then fed into the DL to calculate blood pressure.The hardware of the experiment comprised 2 PPG components(i.e.,Raspberry Pi 3 Model B and analog-todigital converter[MCP3008]),which were connected using a serial peripheral interface.The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure(SBP),diastolic blood pressure(DBP)and mean arterial pressure(MAP).To increase the robustness of the DL model,this study input data of 100 Asian participants into the training database,including those with and without cardiovascular disease,each with a proportion of approximately 50%.The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17±0.46 mmHg.The mean absolute error and standard deviation of DBP was 0.27±0.52 mmHg.The mean absolute error and standard deviation of MAP was 0.16±0.40 mmHg.展开更多
The principle for blood pressure measurement using pulse transit time is introduced in this paper.And the math model of synergetics theory is studied in detail.The synergetics theory is applied in the analysis of bloo...The principle for blood pressure measurement using pulse transit time is introduced in this paper.And the math model of synergetics theory is studied in detail.The synergetics theory is applied in the analysis of blood pressure measurement data.The simulation results show that the application of synergetics theory is helpful to judge the normal blood pressure,and the accuracy is up to 80%.展开更多
Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding o...Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding of the functional relationship between blood pressure and pulse wave signal conduction time.And through imaging photoelectric plethysmography(IPPG),pulse wave signal conduction time of forehead and hand was obtained with ordinary optical camera.First,the pulse wave conduction time was obtained by recording the video with an ordinary optical camera.Second,real-time blood pressure values were collected.Finally,based on the relationship between blood pressure and pulse wave conduction time,a non-contact blood pressure measurement prediction model was obtained through neural network fitting.So that non-contact blood pressure measurement with optical camera could be completed.The method in this paper has several advantages,such as low requirements on measuring equipment,low cost,and simple operation.It can let people get rid of the discomfort caused by measuring equipment such as cuff and can measure blood pressure at any time.The predicted blood pressure results were compared with an Omron wrist electronic sphygmomanometer.The calculated error of systolic blood pressure is-9.28%~3.16%,and the error of diastolic blood pressure is-9.84~4.35%.展开更多
AIMTo investigate the relationship between circadian vari-ations in blood pressure (BP) and albuminuria at rest, and during exercise in non-hypertensive type 2 diabetes (T2D) patients.METHODSWe conducted a cross-s...AIMTo investigate the relationship between circadian vari-ations in blood pressure (BP) and albuminuria at rest, and during exercise in non-hypertensive type 2 diabetes (T2D) patients.METHODSWe conducted a cross-sectional study in well controlled T2D patients, non-hypertensive, without clinical pro-teinuria and normal creatinine clearance. In each parti-cipant, we recorded the BP using ambulatory bloodTankeu AT et al . Exercise-induced albuminuria and BP in T2DMpressure monitoring (ABPM) for 24-h, and albuminuria at rest and after a standardized treadmill exercise.RESULTSWe enrolled 27 type 2 patients with a median age of 52; and a mean duration of diabetes and HbA1c of 3.6 ± 0.8 years and 6.3% ± 0.5% respectively. Using a 24-h ABPM, we recorded a mean diurnal systolic blood pressure (SBP) of 128 ± 17 mmHg vs nocturnal of 123 ± 19 mmHg ( P = 0.004), and mean diurnal diastolic blood pressure (DBP) of 83 ± 11 mmHg vs nocturnal 78 ± 14 mmHg ( P = 0.002). There was a signifcant difference between albuminuria at rest [median = 23 mg, interquartile range (IQR) = 10-51] and after exercise (median = 35 mg, IQR = 23-80, P 〈 0.001). Patients with exercise induced albuminuria had an increase in nocturnal BP values on all three components (128 mmHg vs 110 mmHg, P = 0.03 for SBP; 83 mmHg vs 66 mmHg, P = 0.04; 106 vs 83, P = 0.02 for mean arterial pressure), as well as albuminuric patients at rest. Moreover, exercise induced albuminuria detect a less increase in nocturnal DBP (83 vs 86, P = 0.03) than resting albuminuria.CONCLUSIONExercise induced albuminuria is associated with anincrease in nocturnal BP values in T2D patients.展开更多
AIM To investigated the relationship between exerciseinduced ambulatory blood pressure measurement(ABPM) abnormalities in type 1 diabetes mellitus(T1DM) adolescents. METHODS We conducted a case-control at the National...AIM To investigated the relationship between exerciseinduced ambulatory blood pressure measurement(ABPM) abnormalities in type 1 diabetes mellitus(T1DM) adolescents. METHODS We conducted a case-control at the National Obesity Center of the Yaoundé Central Hospital, Cameroon. We compared 24 h ABPM and urinary albumin-to-creatinine ratio(ACR) at rest and after a standardized treadmill exercise between 20 Cameroonian T1 DM patients and 20 matched controls. T1 DM adolescents were aged 12-18 years, with diabetes for at least one year, without proteinuria, with normal office blood pressure(BP) and renal function according to the general referencepopulation. Non-diabetic controls were adolescents of general population matched for sex, age and BMI.RESULTS Mean duration of diabetes was 4.2 ± 2.8 years. The mean 24 h systolic blood pressure(SBP) and diastolic blood pressure(DBP) were respectively 116 ± 9 mm Hg in the diabetic group vs 111 ± 8 mm Hg in the nondiabetic(P = 0.06), and 69 ± 7 mm Hg vs 66 ± 5 mm Hg(P = 0.19). There was no difference in the diurnal pattern of BP in diabetes patients and non-diabetic controls(SBP: 118 ± 10 mm Hg vs 114 ± 10 mm Hg, P = 0.11; DBP: 71 ± 7 mm Hg vs 68 ± 6 mm Hg, P = 0.22). Nighttime BP was higher in the diabetic group with respect to SBP(112 ± 11 mm Hg vs 106 ± 7 mm Hg, P = 0.06) and to the mean arterial pressure(MAP)(89 ± 9 mm Hg vs 81 ± 6 mm Hg, P = 0.06). ACR at rest was similar in both groups(5.5 mg/g vs 5.5 mg/g, P = 0.74), but significantly higher in diabetes patients after exercise(10.5 mg/g vs 5.5 mg/g, P = 0.03). SBP was higher in patients having exercise-induced albuminuria(116 ± 10 mm Hg vs 108 ± 10 mm Hg, P = 0.09). CONCLUSION Exercise-induced albuminuria could be useful for early diagnosis of kidney damage in adolescents with T1 DM.展开更多
Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate...Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate the dependence of the sub-harmonic generation on the overpressure with different excitation pressure amplitudes and pulse lengths. With 4-MHz ultrasound excitation at an applied acoustic pressure amplitude of 0.24 MPa, the measured sub-harmonic amplitude exhibits a decreasing change as overpressure increases; while non-monotonic change is observed for the applied acoustic pressures of 0.36 MPa and 0.48 MPa, and the peak position in the curve of the sub-harmonic response versus the overpres- sure shifts toward higher overpressure as the excitation pressure amplitude increases. Furthermore, the exciting pulse with long duration could lead to a better sensitivity of the sub-harmonic response to overpressure. The measured results are ex- plained by the numerical simulations based on the Marmottant model. The numerical simulations qualitatively accord with the measured results. This work might provide a preliminary proof for the optimization of the noninvasive blood pressure measurement through using sub-harmonic generation from microbubbles.展开更多
Background: Peripheral artery disease (PAD) is the least recognized form of atherosclerosis and may even result in amputation if the diagnosis is delayed. Manual pulse palpation is the traditional way to diagnose PAD....Background: Peripheral artery disease (PAD) is the least recognized form of atherosclerosis and may even result in amputation if the diagnosis is delayed. Manual pulse palpation is the traditional way to diagnose PAD. Doppler ultrasonographic measurement of ankle-brachial index (ABI) is the gold standard diagnosing method but requires training and is not necessarily available as an outpatient procedure. Using automated oscillometric blood pressure devices has been suggested as an easier method for measuring the ABI. Methods: A single observer palpated the arterial dorsalis pedis, examined hand joints and measured the ABI of one hundred diabetic patients using both Doppler and oscillometric methods. The purpose of this study was to compare the oscillometric method and the manual diagnosing methods to the gold standard method of using a hand held Doppler device for measuring the ABI and detecting PAD. Results: ABI was abnormal in 24 patients (24%) (22 males, 2 females) when measured with the Doppler method. Of these 24 patients, the oscillometric method would have missed 12 giving 12 false negatives. We found that the sensitivity of the oscillometric method was 50.0% and specificity 90.8%. Clinical examination with palpation of ADP combined with limited joint mobility (LJM) scoring would have missed only four cases. Conclusions: Although the oscillometric method is easy and accessible, it is not sensitive enough to be used as the only method in measuring ABI. The simple and inexpensive ADP pulse palpation combined with testing for LMJ was able to find 20 of the 24 (83%) patients with an abnormal ABI measured by Doppler stethoscope.展开更多
Intramedullary pressure increases after spinal cord injury, and this can be an important factor for secondary spinal cord injury. Until now there have been no studies of the dynamic changes of intramedullary pressure ...Intramedullary pressure increases after spinal cord injury, and this can be an important factor for secondary spinal cord injury. Until now there have been no studies of the dynamic changes of intramedullary pressure after spinal cord injury. In this study, telemetry systems were used to observe changes in intramedullary pressure in the 72 hours following spinal cord injury to explore its pathological mechanisms. Spinal cord injury was induced using an aneurysm clip at T10 of the spinal cord of 30 Japanese white rabbits, while another 32 animals were only subjected to laminectomy. The feasibility of this measurement was assessed. Intramedullary pressure was monitored in anesthetized and conscious animals. The dynamic changes of intramedullary pressure after spinal cord injury were divided into three stages: stage I(steep rise) 1–7 hours, stage Ⅱ(steady rise) 8–38 hours, and stage Ⅲ(descending) 39–72 hours. Blood-spinal barrier permeability, edema, hemorrhage, and histological results in the 72 hours following spinal cord injury were evaluated according to intramedullary pressure changes. We found that spinal cord hemorrhage was most severe at 1 hour post-spinal cord injury and then gradually decreased; albumin and aquaporin 4 immunoreactivities first increased and then decreased, peaking at 38 hours. These results confirm that severe bleeding in spinal cord tissue is the main cause of the sharp increase in intramedullary pressure in early spinal cord injury. Spinal cord edema and blood-spinal barrier destruction are important factors influencing intramedullary pressure in stages Ⅱ and Ⅲ of spinal cord injury.展开更多
In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied ...In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method.展开更多
文摘Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese subjects, those with secondary hypertension or resistant, diabetics, subjects with metabolic syndrome or sleep apnea syndrome. The objective of this study was to evaluate the contribution of ABPM in the diagnosis and evaluation of the level of control of hypertension under treatment at the Bel Air international clinic. Materials and Methods: This is a retrospective, cross-sectional and descriptive study, carried out at the Bel Air International Clinic in Conakry (Guinea) between January 2019 and November 30, 2022. It included a consecutive series of 180 consenting patients recruited through an ambulatory measurement of 24-hour blood pressure from a FUGADA brand device. Results: We collected 180 patients, with a male predominance (sex-ratio M/F = 2.46). The mean age of the patients was 48.48 ± 14.23 years. The most represented age group was that of 32 to 42 years with 50 cases (27.8%) followed by that of 43 to 52 years with 42 cases or 23.3%. The indication was for diagnostic purposes in 106 cases 58.9%, the therapeutic evaluation in 58 patients (32.2%). The examination was prescribed by a cardiologist in 98 cases (54.4%), a general practitioner in 71 cases (39.4%), a neurologist in 11 cases (6.1%). In the therapeutic evaluation, high blood pressure was controlled in 24 patients (13.3%) and uncontrolled in 34 cases (18.9%). In the diagnostic indication, high blood pressure was confirmed in 79 cases (43.9%) with a statistically significant link (Chi2</sup> = 4.57 and p-value = 0.032). The nycthemeral mean was 187.27 ± 26.22 mmHg for systolic blood pressure (SBP) and 110.37 ± 19.06 mmHg for diastolic blood pressure (DBP), during the day, 151.64 ± 21.45 mmHg for SBP and 71.59 ± 8.67 mmHg for diastolic blood pressure. During the study 65 patients (36.1%) were identified as dippers and 115 patients (63.9%) were no-dipping. The antihypertensive protocol used was monotherapy in 68 cases (37.8%), dual therapy in 46 cases (25.6%), triple therapy in 17 cases (9.4%). However 39 patients or 21.7% were not taking any antihypertensive. Conclusion: This preliminary study, despite the modest sample size, showed the importance of ABPM as a tool for diagnosis, monitoring of hypertensive patients and therapeutic adaptation. A large-scale national study would be necessary for the rational use of ambulatory blood pressure measurement in our context in order to improve the management of hypertensive patients.
文摘Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hypertensive patients led us to study the knowledge, compliance and effect of HDMs among Cameroonian hypertensive patients. Methods: This was a cross-sectional study carried out at the Douala General Hospital;the census of patients was carried out from 05 March to 10 May 2018. The data evaluated were knowledge and compliance with HDMs with an inference of their effect on blood pressure control. Results: We recruited 330 participants at mean age of 60 ± 11 years, 37.9% men;57.3% with blood pressure (BP) controlled. Out of 330 subjects, 308 (93.3%) who had been educated about dietary health measures for hypertension were assessed on knowledge, compliance and effect of these measures against 22 (6.7%) who had never heard about them. Around 85.7% of participants had good knowledge of HDMs and 78.9% had good compliance with them. There was no statistically significant influence of knowledge and compliance with HDMs on blood pressure control. Conclusion: The level of knowledge and adherence to HDMs of hypertensive patients at the Douala General Hospital was appreciable. It is however appropriate for physicians to intensify patient education on HDMs and BP control.
文摘In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic BP (SBP) and the diastolic BP (DBP) fluctuated a large amount even though they were measured at a short interval. The first measurements were 6.7 and 2.4 mmHg higher than the second ones for SBP and DBP, suggesting a white coat effect. Then, the factors that might affect the differences between the two measurements were analyzed by the regression models. For both SBP and DBP, the difference increased as the first measurement increased. Age, gender, BMI and alcohol consumption were other important factors affecting the difference. In the case of a typical male individual, the typical criteria for hypertension of 140/90, 160/100 and 180/110 mmHg criteria in the first measurement would correspond to 135/86, 150/94 and 165/102 mmHg in the second measurement. The necessity of developing accurate and cost-efficient BP measurement methods is strongly suggested.
基金supported in part by the National Natural Science Foundation of China (Grant 81370438)the SJTU Medical-Engineering Cross-cutting Research Project (Grant YG2015MS53)supported by the Hui-Chun Chin and Tsung-Dao Lee Chinese Undergraduate Research Program Endowment
文摘An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element(FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement.
基金This study was supported in part by the Ministry of Science and Technology MOST 108-2221-E-150-022-MY3 and Taiwan Ocean University.
文摘This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators.The proposed platform measured the signal changes in PPG and converted them into physiological indicators,such as pulse transit time(PTT),pulse wave velocity(PWV),perfusion index(PI)and heart rate(HR);these indicators were then fed into the DL to calculate blood pressure.The hardware of the experiment comprised 2 PPG components(i.e.,Raspberry Pi 3 Model B and analog-todigital converter[MCP3008]),which were connected using a serial peripheral interface.The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure(SBP),diastolic blood pressure(DBP)and mean arterial pressure(MAP).To increase the robustness of the DL model,this study input data of 100 Asian participants into the training database,including those with and without cardiovascular disease,each with a proportion of approximately 50%.The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17±0.46 mmHg.The mean absolute error and standard deviation of DBP was 0.27±0.52 mmHg.The mean absolute error and standard deviation of MAP was 0.16±0.40 mmHg.
文摘The principle for blood pressure measurement using pulse transit time is introduced in this paper.And the math model of synergetics theory is studied in detail.The synergetics theory is applied in the analysis of blood pressure measurement data.The simulation results show that the application of synergetics theory is helpful to judge the normal blood pressure,and the accuracy is up to 80%.
基金The work of this paper is supported by the National Natural Science Foundation of China under Grant No.61572038,the Innovation Project Foundation NCUT.
文摘Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding of the functional relationship between blood pressure and pulse wave signal conduction time.And through imaging photoelectric plethysmography(IPPG),pulse wave signal conduction time of forehead and hand was obtained with ordinary optical camera.First,the pulse wave conduction time was obtained by recording the video with an ordinary optical camera.Second,real-time blood pressure values were collected.Finally,based on the relationship between blood pressure and pulse wave conduction time,a non-contact blood pressure measurement prediction model was obtained through neural network fitting.So that non-contact blood pressure measurement with optical camera could be completed.The method in this paper has several advantages,such as low requirements on measuring equipment,low cost,and simple operation.It can let people get rid of the discomfort caused by measuring equipment such as cuff and can measure blood pressure at any time.The predicted blood pressure results were compared with an Omron wrist electronic sphygmomanometer.The calculated error of systolic blood pressure is-9.28%~3.16%,and the error of diastolic blood pressure is-9.84~4.35%.
文摘AIMTo investigate the relationship between circadian vari-ations in blood pressure (BP) and albuminuria at rest, and during exercise in non-hypertensive type 2 diabetes (T2D) patients.METHODSWe conducted a cross-sectional study in well controlled T2D patients, non-hypertensive, without clinical pro-teinuria and normal creatinine clearance. In each parti-cipant, we recorded the BP using ambulatory bloodTankeu AT et al . Exercise-induced albuminuria and BP in T2DMpressure monitoring (ABPM) for 24-h, and albuminuria at rest and after a standardized treadmill exercise.RESULTSWe enrolled 27 type 2 patients with a median age of 52; and a mean duration of diabetes and HbA1c of 3.6 ± 0.8 years and 6.3% ± 0.5% respectively. Using a 24-h ABPM, we recorded a mean diurnal systolic blood pressure (SBP) of 128 ± 17 mmHg vs nocturnal of 123 ± 19 mmHg ( P = 0.004), and mean diurnal diastolic blood pressure (DBP) of 83 ± 11 mmHg vs nocturnal 78 ± 14 mmHg ( P = 0.002). There was a signifcant difference between albuminuria at rest [median = 23 mg, interquartile range (IQR) = 10-51] and after exercise (median = 35 mg, IQR = 23-80, P 〈 0.001). Patients with exercise induced albuminuria had an increase in nocturnal BP values on all three components (128 mmHg vs 110 mmHg, P = 0.03 for SBP; 83 mmHg vs 66 mmHg, P = 0.04; 106 vs 83, P = 0.02 for mean arterial pressure), as well as albuminuric patients at rest. Moreover, exercise induced albuminuria detect a less increase in nocturnal DBP (83 vs 86, P = 0.03) than resting albuminuria.CONCLUSIONExercise induced albuminuria is associated with anincrease in nocturnal BP values in T2D patients.
文摘AIM To investigated the relationship between exerciseinduced ambulatory blood pressure measurement(ABPM) abnormalities in type 1 diabetes mellitus(T1DM) adolescents. METHODS We conducted a case-control at the National Obesity Center of the Yaoundé Central Hospital, Cameroon. We compared 24 h ABPM and urinary albumin-to-creatinine ratio(ACR) at rest and after a standardized treadmill exercise between 20 Cameroonian T1 DM patients and 20 matched controls. T1 DM adolescents were aged 12-18 years, with diabetes for at least one year, without proteinuria, with normal office blood pressure(BP) and renal function according to the general referencepopulation. Non-diabetic controls were adolescents of general population matched for sex, age and BMI.RESULTS Mean duration of diabetes was 4.2 ± 2.8 years. The mean 24 h systolic blood pressure(SBP) and diastolic blood pressure(DBP) were respectively 116 ± 9 mm Hg in the diabetic group vs 111 ± 8 mm Hg in the nondiabetic(P = 0.06), and 69 ± 7 mm Hg vs 66 ± 5 mm Hg(P = 0.19). There was no difference in the diurnal pattern of BP in diabetes patients and non-diabetic controls(SBP: 118 ± 10 mm Hg vs 114 ± 10 mm Hg, P = 0.11; DBP: 71 ± 7 mm Hg vs 68 ± 6 mm Hg, P = 0.22). Nighttime BP was higher in the diabetic group with respect to SBP(112 ± 11 mm Hg vs 106 ± 7 mm Hg, P = 0.06) and to the mean arterial pressure(MAP)(89 ± 9 mm Hg vs 81 ± 6 mm Hg, P = 0.06). ACR at rest was similar in both groups(5.5 mg/g vs 5.5 mg/g, P = 0.74), but significantly higher in diabetes patients after exercise(10.5 mg/g vs 5.5 mg/g, P = 0.03). SBP was higher in patients having exercise-induced albuminuria(116 ± 10 mm Hg vs 108 ± 10 mm Hg, P = 0.09). CONCLUSION Exercise-induced albuminuria could be useful for early diagnosis of kidney damage in adolescents with T1 DM.
基金Project supported by the National Basic Research Program from Ministry of Science and Technology,China(Grant No.2011CB707900)the National Natural Science Foundation of China(Grant Nos.81271589,81227004,11174141,11374155,11612032,and 81301616)the Natural Science Foundation of Jiangsu Province,China(Grant Nos.BE2011110 and BK20131017)
文摘Sub-harmonic component generated from microbubbles is proven to be potentially used in noninvasive blood pressure measurement. Both theoretical and experimental studies are performed in the present work to investigate the dependence of the sub-harmonic generation on the overpressure with different excitation pressure amplitudes and pulse lengths. With 4-MHz ultrasound excitation at an applied acoustic pressure amplitude of 0.24 MPa, the measured sub-harmonic amplitude exhibits a decreasing change as overpressure increases; while non-monotonic change is observed for the applied acoustic pressures of 0.36 MPa and 0.48 MPa, and the peak position in the curve of the sub-harmonic response versus the overpres- sure shifts toward higher overpressure as the excitation pressure amplitude increases. Furthermore, the exciting pulse with long duration could lead to a better sensitivity of the sub-harmonic response to overpressure. The measured results are ex- plained by the numerical simulations based on the Marmottant model. The numerical simulations qualitatively accord with the measured results. This work might provide a preliminary proof for the optimization of the noninvasive blood pressure measurement through using sub-harmonic generation from microbubbles.
文摘Background: Peripheral artery disease (PAD) is the least recognized form of atherosclerosis and may even result in amputation if the diagnosis is delayed. Manual pulse palpation is the traditional way to diagnose PAD. Doppler ultrasonographic measurement of ankle-brachial index (ABI) is the gold standard diagnosing method but requires training and is not necessarily available as an outpatient procedure. Using automated oscillometric blood pressure devices has been suggested as an easier method for measuring the ABI. Methods: A single observer palpated the arterial dorsalis pedis, examined hand joints and measured the ABI of one hundred diabetic patients using both Doppler and oscillometric methods. The purpose of this study was to compare the oscillometric method and the manual diagnosing methods to the gold standard method of using a hand held Doppler device for measuring the ABI and detecting PAD. Results: ABI was abnormal in 24 patients (24%) (22 males, 2 females) when measured with the Doppler method. Of these 24 patients, the oscillometric method would have missed 12 giving 12 false negatives. We found that the sensitivity of the oscillometric method was 50.0% and specificity 90.8%. Clinical examination with palpation of ADP combined with limited joint mobility (LJM) scoring would have missed only four cases. Conclusions: Although the oscillometric method is easy and accessible, it is not sensitive enough to be used as the only method in measuring ABI. The simple and inexpensive ADP pulse palpation combined with testing for LMJ was able to find 20 of the 24 (83%) patients with an abnormal ABI measured by Doppler stethoscope.
基金supported by the National Natural Science Foundation of China,No.81272164(to JJL)the Special Fund for Basic Scientific Research of Central Public Research Institutes in China,No.2016CZ-4(to JJL),2018CZ-1(to JJL)+1 种基金the Beijing Institute for Brain Disorders in China,No.0000-100031(to JJL)the Basic Scientific Research Foundation of China Rehabilitation Research Center,No.2017ZX-22,2017ZX-20(to JJL)
文摘Intramedullary pressure increases after spinal cord injury, and this can be an important factor for secondary spinal cord injury. Until now there have been no studies of the dynamic changes of intramedullary pressure after spinal cord injury. In this study, telemetry systems were used to observe changes in intramedullary pressure in the 72 hours following spinal cord injury to explore its pathological mechanisms. Spinal cord injury was induced using an aneurysm clip at T10 of the spinal cord of 30 Japanese white rabbits, while another 32 animals were only subjected to laminectomy. The feasibility of this measurement was assessed. Intramedullary pressure was monitored in anesthetized and conscious animals. The dynamic changes of intramedullary pressure after spinal cord injury were divided into three stages: stage I(steep rise) 1–7 hours, stage Ⅱ(steady rise) 8–38 hours, and stage Ⅲ(descending) 39–72 hours. Blood-spinal barrier permeability, edema, hemorrhage, and histological results in the 72 hours following spinal cord injury were evaluated according to intramedullary pressure changes. We found that spinal cord hemorrhage was most severe at 1 hour post-spinal cord injury and then gradually decreased; albumin and aquaporin 4 immunoreactivities first increased and then decreased, peaking at 38 hours. These results confirm that severe bleeding in spinal cord tissue is the main cause of the sharp increase in intramedullary pressure in early spinal cord injury. Spinal cord edema and blood-spinal barrier destruction are important factors influencing intramedullary pressure in stages Ⅱ and Ⅲ of spinal cord injury.
基金supported by the National Natural Science Foundation of China (No.61675174)the Natural Science Foundation of Fujian Province (No.2020J01705)。
文摘In this paper, we present a method based on self-mixing interferometry combing extreme learning machine for real-time human blood pressure measurement. A signal processing method based on wavelet transform is applied to extract reversion point in the self-mixing interference signal, thus the pulse wave profile is successfully reconstructed. Considering the blood pressure values are intrinsically related to characteristic parameters of the pulse wave, 80 samples from the MIMIC-II database are used to train the extreme learning machine blood pressure model. In the experiment, 15 measured samples of pulse wave signal are used as the prediction sets. The results show that the errors of systolic and diastolic blood pressure are both within 5 mm Hg compared with that by the Coriolis method.