This paper rejuvenates the notion of conformance testing in order to assess the security of networks. It leverages the Testing and Test Control Notation Version 3 (TTCN-3) by applying it to a redefined notion of <i...This paper rejuvenates the notion of conformance testing in order to assess the security of networks. It leverages the Testing and Test Control Notation Version 3 (TTCN-3) by applying it to a redefined notion of <i>System under Test</i> (<i>SUT</i>). Instead of testing, as it is classically done, a software/firmware/ hardware element, an intangible object, namely the network, is tested in order to infer some of its security properties. After a brief introduction of TTCN-3 and Titan, its compilation and execution environment, a couple of use cases are provided to illustrate the feasibility of the approach. The pros and cons of using TTCN-3 to implement a scalable and flexible network testing environment are discussed.展开更多
In the construction and maintenance of particle accelerators,all the accelerator elements should be installed in the same coordinate system,only in this way could the devices in the actual world be consistent with the...In the construction and maintenance of particle accelerators,all the accelerator elements should be installed in the same coordinate system,only in this way could the devices in the actual world be consistent with the design drawings.However,with the occurrence of the movements of the reinforced concrete cover plates at short notice or building deformations in the long term,the control points upon the engineering structure will be displaced,and the fitness between the subnetwork and the global control network may be irresponsible.Therefore,it is necessary to evaluate the deformations of the 3D alignment control network.Different from the extant investigations,in this paper,to characterize the deformations of the control network,all of the congruent models between the points measured in different epochs have been identified,and the congruence model with the most control points is considered as the primary or fundamental model,the remaining models are recognized as the additional ones.Furthermore,the discrepancies between the primary S-transformation parameters and the additional S-transformation parameters can reflect the relative movements of the additional congruence models.Both the iterative GCT method and the iterative combinatorial theory are proposed to detect multiple congruence models in the control network.Considering the actual work of the alignment,it is essential to identify the competitive models in the monitoring network,which can provide us a hint that,even the fitness between the subnetwork and the global control network is good,there are still deformations which may be ignored.The numerical experiments show that the suggested approaches can describe the deformation of the 3D alignment control network roundly.展开更多
应用测试和测试控制表示法第三版(testing and test control notation version 3,TTCN-3)设计了一种名址分离协议(locator/identity separation protocol,LISP)的一致性自动化测试系统。该系统根据LISP协议标准RFC6830和RFC6833,运用抽...应用测试和测试控制表示法第三版(testing and test control notation version 3,TTCN-3)设计了一种名址分离协议(locator/identity separation protocol,LISP)的一致性自动化测试系统。该系统根据LISP协议标准RFC6830和RFC6833,运用抽象语法规则1(abstract syntax notation one,ASN.1)描述报文结构,设计测试用例,编写测试脚本。脚本通过自动下发配置,构造数据报文,完成交互过程。对LISP基本功能实现的9个测试点进行协议一致性测试,测试结果表明,9个测试点均通过测试。展开更多
文摘This paper rejuvenates the notion of conformance testing in order to assess the security of networks. It leverages the Testing and Test Control Notation Version 3 (TTCN-3) by applying it to a redefined notion of <i>System under Test</i> (<i>SUT</i>). Instead of testing, as it is classically done, a software/firmware/ hardware element, an intangible object, namely the network, is tested in order to infer some of its security properties. After a brief introduction of TTCN-3 and Titan, its compilation and execution environment, a couple of use cases are provided to illustrate the feasibility of the approach. The pros and cons of using TTCN-3 to implement a scalable and flexible network testing environment are discussed.
文摘In the construction and maintenance of particle accelerators,all the accelerator elements should be installed in the same coordinate system,only in this way could the devices in the actual world be consistent with the design drawings.However,with the occurrence of the movements of the reinforced concrete cover plates at short notice or building deformations in the long term,the control points upon the engineering structure will be displaced,and the fitness between the subnetwork and the global control network may be irresponsible.Therefore,it is necessary to evaluate the deformations of the 3D alignment control network.Different from the extant investigations,in this paper,to characterize the deformations of the control network,all of the congruent models between the points measured in different epochs have been identified,and the congruence model with the most control points is considered as the primary or fundamental model,the remaining models are recognized as the additional ones.Furthermore,the discrepancies between the primary S-transformation parameters and the additional S-transformation parameters can reflect the relative movements of the additional congruence models.Both the iterative GCT method and the iterative combinatorial theory are proposed to detect multiple congruence models in the control network.Considering the actual work of the alignment,it is essential to identify the competitive models in the monitoring network,which can provide us a hint that,even the fitness between the subnetwork and the global control network is good,there are still deformations which may be ignored.The numerical experiments show that the suggested approaches can describe the deformation of the 3D alignment control network roundly.
文摘应用测试和测试控制表示法第三版(testing and test control notation version 3,TTCN-3)设计了一种名址分离协议(locator/identity separation protocol,LISP)的一致性自动化测试系统。该系统根据LISP协议标准RFC6830和RFC6833,运用抽象语法规则1(abstract syntax notation one,ASN.1)描述报文结构,设计测试用例,编写测试脚本。脚本通过自动下发配置,构造数据报文,完成交互过程。对LISP基本功能实现的9个测试点进行协议一致性测试,测试结果表明,9个测试点均通过测试。