期刊文献+
共找到2,062篇文章
< 1 2 104 >
每页显示 20 50 100
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
1
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
下载PDF
Response of multi-step compound pre-equilibrium reaction cross sections for the(p,n)reactions to forms of optical model parameters 被引量:1
2
作者 Felix S.Olise Oludaisi I.Oladunjoye +2 位作者 Afis Ajala Sunday D.Olorunfunmi Hezekiah B.Oianiyi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第10期65-70,共6页
In furtherance to improving agreement between calculated and experimental nuclear data, the nuclear reaction code GAMME was used to calculate the multistep compound(MSC) nucleus double differential cross sections(DDCs... In furtherance to improving agreement between calculated and experimental nuclear data, the nuclear reaction code GAMME was used to calculate the multistep compound(MSC) nucleus double differential cross sections(DDCs) for proton-induced neutron emission reactions using the Feshbach-Kerman-Koonin(FKK) formalism. The cross sections were obtained for reactor structural materials involving ^(52)Cr(p, n)^(52)Mn,^(56)Fe(p,n)^(56)Co, and ^(60)Ni(p, n)^(60)Cu reactions at 22.2 MeV incident energy using the zero-range reaction mechanism. Effective residual interaction strength was 28 MeV, and different optical potential parameters were used for the entrance and exit channels of the proton-neutron interactions. The calculated DDCs were fitted to experimental data at the same backward angle of 150°, where the MSC processes dominate. The calculated and experimental data agree well in the region of pre-equilibrium(MSC) reaction dominance against a weaker fit at the lower emission energies. We attribute underestimations to contributions from the other reaction channels and disagreement at higher outgoing energies to reactions to collectively excited states. Contrary to the FKK multi-step direct calculations, contributions from the higher stages to the DDCs are significant. Different sets of parameters resulted in varying levels of agreement of calculated and experimental data for the considered nuclei. 展开更多
关键词 反应截面 光学势参数 预平衡 模型参数 多步 复合 相互作用强度 实验数据
下载PDF
Magneto-optical Disk Material for Improving the Density of Information Storage
3
作者 夏红霞 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2001年第2期54-57,共4页
This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal dis... This paper introduces the fundamental principle and features ofmagneto-optical storage technol- ogy, and discuses the trend and aseries of key techniques for increasing the data storage density ofmagneto-opti- cal disk. The three ways including MO media, recordingmethod and readout method for increasing the disk ca- pacity havebeen discussed. Moreover, the importance with the exchange-coupledeffect between the magnetic layers and recording domain morphology isemphasized. 展开更多
关键词 magneto-optical disk information storage recording density
下载PDF
Refined Anam-Net:Lightweight Deep Learning Model for Improved Segmentation Performance of Optic Cup and Disc for Glaucoma Diagnosis
4
作者 Khursheed Aurangzeb Syed Irtaza Haider Musaed Alhussein 《Computers, Materials & Continua》 SCIE EI 2024年第7期1381-1405,共25页
In this work,we aim to introduce some modifications to the Anam-Net deep neural network(DNN)model for segmenting optic cup(OC)and optic disc(OD)in retinal fundus images to estimate the cup-to-disc ratio(CDR).The CDR i... In this work,we aim to introduce some modifications to the Anam-Net deep neural network(DNN)model for segmenting optic cup(OC)and optic disc(OD)in retinal fundus images to estimate the cup-to-disc ratio(CDR).The CDR is a reliable measure for the early diagnosis of Glaucoma.In this study,we developed a lightweight DNN model for OC and OD segmentation in retinal fundus images.Our DNN model is based on modifications to Anam-Net,incorporating an anamorphic depth embedding block.To reduce computational complexity,we employ a fixed filter size for all convolution layers in the encoder and decoder stages as the network deepens.This modification significantly reduces the number of trainable parameters,making the model lightweight and suitable for resource-constrained applications.We evaluate the performance of the developed model using two publicly available retinal image databases,namely RIM-ONE and Drishti-GS.The results demonstrate promising OC segmentation performance across most standard evaluation metrics while achieving analogous results for OD segmentation.We used two retinal fundus image databases named RIM-ONE and Drishti-GS that contained 159 images and 101 retinal images,respectively.For OD segmentation using the RIM-ONE we obtain an f1-score(F1),Jaccard coefficient(JC),and overlapping error(OE)of 0.950,0.9219,and 0.0781,respectively.Similarly,for OC segmentation using the same databases,we achieve scores of 0.8481(F1),0.7428(JC),and 0.2572(OE).Based on these experimental results and the significantly lower number of trainable parameters,we conclude that the developed model is highly suitable for the early diagnosis of glaucoma by accurately estimating the CDR. 展开更多
关键词 Refined Anam-Net parameter tuning deep learning optic cup optic disc cup-to-disc ratio glaucoma diagnosis
下载PDF
The change of anterior segment parameters after cataract surgery in normal-tension glaucoma 被引量:3
5
作者 Wonseok Lee Hyoung Won Bae +1 位作者 Chart Yun Kim Gong Je Seong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第8期1239-1245,共7页
AIM: To investigate the change of anterior chamber angle morphology and intraocular pressure (lOP) reduction after cataract surgery in patients with normal-tension glaucoma (NTG) using swept-source optical cohere... AIM: To investigate the change of anterior chamber angle morphology and intraocular pressure (lOP) reduction after cataract surgery in patients with normal-tension glaucoma (NTG) using swept-source optical coherence tomography (SS-OCT). METHODS: This prospective, comparative, observational study recruited patients into two groups. Group 1 was the control group including normal subjects except those with cataracts (cataract group, n=67 eyes of 67 patients), and group 2 was NTG group including patients who were diagnosed with NTG and cataracts (n=43 eyes of 43 patients), which were treated with phacoemulsification and intraocular lens implantation. Before surgery, and at postoperative 1 and 6too, anterior chamber angles were evaluated by SS-OCT under dark conditions using three- dimensional angle analysis scan protocol. Angle opening distance (AOD), angle recess area (ARA), and trabecular- iris surface area (TISA) at four quadrants (temporal, nasal, superior, and inferior) were calculated automatically by SS-OGT, after the observer marked scleral spurs. RESULTS: A total of 106 patients (54 males and 52 females) were enrolled in the study. Angle parameters, AOD, ARA, and TISA were increased after surgery in both groups. However, changes of angle parameters were only significant in group 2. In group 2, preoperative lOP was 13.2+2.9 mm Hg, and postoperative lOP at 1 and 6mo were 10.5+3.0 and 10.7+2.8 mm Hg, respectively. In group 1, preoperative lOP was 12.42.8 mm Hg, and postoperative lOP at 1 and 6mo were 11.6+2.5 and 12.0+2.8 mm Hg, respectively. After cataract surgery, angle parameters changed significantly while IOP significantly reduced and was maintained in group 2 (P〈0.001). The changes in angle parameters (&AOD500, ATISAS00 at temporal; &AOD500, S, RA500 at nasal) were linearly correlated with postoperative IOP changes. CONCLUSION: Cataract surgery may have improved antedor chamber angle parameters and decreased lOP in NTG patients. 展开更多
关键词 normal-tension glaucoma cataract surgery intraocular pressure reduction swept-source optical coherence tomography angle parameters
下载PDF
Supercontinuum spectra generation in the single-mode optical fibre with concave dispersion profile 被引量:1
6
作者 徐文成 高洁丽 +2 位作者 梁湛强 陈巧红 刘颂豪 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第4期715-720,共6页
In this paper, a new method is proposed to generate broad supercontinuum (SC) spectra in the single-mode optical fibre with concave dispersion profile, We numerically simulate pulse evolutions and discuss physics me... In this paper, a new method is proposed to generate broad supercontinuum (SC) spectra in the single-mode optical fibre with concave dispersion profile, We numerically simulate pulse evolutions and discuss physics mechanism in detail for SC spectrum generation in the optical fibre with concave dispersion profile. Furthermore, general criteria are presented for specifying the shape of SC spectrum by introducing normalized parameters, which are related to the fibres and the initial pump pulses. The results show that the flat and broad SC spectra are indeed generated in our proposed optical fibre. 展开更多
关键词 supercontinuum spectrum optical pulse compression dispersion-flattened / dispersion-decreasing fibre normalized parameters
下载PDF
On the possibility of disk-fed formation in supergiant high-mass X-ray binaries
7
作者 Ali Taani Shigeyuki Karino +3 位作者 Liming Song Mashhoor Al-Wardat Awni Khasawneh Mohammad K.Mardini 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2019年第1期123-130,共8页
We consider the existence of a neutron star magnetic field by the detected cyclotron lines. We collected data on nine sources of high-mass X-ray binaries with supergiant companions as a test case for our model, to dem... We consider the existence of a neutron star magnetic field by the detected cyclotron lines. We collected data on nine sources of high-mass X-ray binaries with supergiant companions as a test case for our model, to demonstrate their distribution and evolution. The wind velocity, spin period and magnetic field strength are studied under different mass loss rates. In our model, correlations between mass-loss rate and wind velocity are found and can be tested in further observations. We examine the parameter space where wind accretion is allowed, avoiding the barrier of rotating magnetic fields, with robust data on the magnetic field of neutron stars. Our model shows that most sources(six of nine systems) can be fed by the wind with relatively slow velocity, and this result is consistent with previous predictions. In a few sources,our model cannot fit the standard wind accretion scenario. In these peculiar cases, other scenarios(disk formation, partial Roche lobe overflow) should be considered. This would provide information about the evolutionary tracks of various types of binaries, and thus exhibit a clear dichotomy behavior in wind-fed X-ray binary systems. 展开更多
关键词 binaries:X-rays stars:neutron stars:fundamental parameters ACCRETION diskS FORMATION magnetic fields
下载PDF
STUDY ON THE POLING PROPERTIES OF NONLINEAR OPTICAL ACTIVE DERIVATIVE OF POLY (p-HYDROXYSTYRENE):(PS)O-DCV
8
作者 叶成 王加赋 冯知明 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1993年第2期185-192,共8页
In this paper, the poling properties of (PS)O-DCV, a derivative of poly (p-hydroxystyrene ), was reported. The investigations showed that the thermochromism correction, which was neglected in the literatures, should b... In this paper, the poling properties of (PS)O-DCV, a derivative of poly (p-hydroxystyrene ), was reported. The investigations showed that the thermochromism correction, which was neglected in the literatures, should be considered in the measurements of order parameter of poled films with electrochromism technique Here, another linear optical method, IR and polarized IR spectra for characterizing of poled films was suggested first time. The bulk second nonlinear optical coefficient d_(33) of poled films could be estimated by measured order parameter semi-qualitatively. 展开更多
关键词 Nonlinear optical polymer POLING ELECTROCHROMISM IR dichroism Order parameter
下载PDF
Effect of the Sputtering Parameters on the Structure and Properties of Cu_3N Thin Film Materials
9
作者 钱显毅 黄致新 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第6期935-937,共3页
Copper nitride (Cu3N) thin films were successfully deposited on glass substrates by reactive radio frequency magnetron sputtering.The effects of sputtering parameters on the structure and properties of the films wer... Copper nitride (Cu3N) thin films were successfully deposited on glass substrates by reactive radio frequency magnetron sputtering.The effects of sputtering parameters on the structure and properties of the films were studied.The experimental results show that with increasing of RF power and nitrogen partial pressure,the preferential crystalline orientation of Cu3N film is changed from (111) to (100).With increasing of substrate temperature from 70 ℃ to 200 ℃,the film phase is changed from Cu3N phase to Cu.With increasing sputtering power from 80 W to 120 W,the optical energy decreases from 1.85 eV to 1.41 eV while the electrical resistivity increases from 1.45 ×102 Ω·cm to 2.99×103 Ω·cm,respectively. 展开更多
关键词 copper nitride sputtering parameters STRUCTURE electrical and optical properties
下载PDF
Theoretical investigation of light generated by optical parametric down-conversion and its application in the demonstration of the EPR paradox
10
作者 赵超樱 《Journal of Shanghai University(English Edition)》 CAS 2007年第2期195-196,共2页
Parametric down-conversion is a useful method to obtain non-classical state in quantum optics. (1) An analytical solution to the Fokker-Planck equation of non-degenerate optical parametric amplification (NOPA) fo... Parametric down-conversion is a useful method to obtain non-classical state in quantum optics. (1) An analytical solution to the Fokker-Planck equation of non-degenerate optical parametric amplification (NOPA) for generation of squeezed light is presented. The maximum intra-cavity compression of squeezed light derived from the analytical solution is 1/16 (vacuum fluctuations 1/4). To compare it with the previous 1/8 of degenerate optical parametric amplification (DOPA), it seems that squeezing for NOPA is superior to DOPA. 展开更多
关键词 degenerate optical parameter amplification non-degenerate optical parameter amplification quantumfluctuation EPR paradox.
下载PDF
Influence of gamma-ray irradiation on optical and thermal degradation of poly (ethyl-methacrylate) (PEMA) polymer
11
作者 S. Fares 《Natural Science》 2012年第7期499-507,共9页
Polymer based on (polyethyl-methacrylate) (PEMA) were exposed to different doses of gamma radiation up to 100 kGy and the physical properties have been studied. The effects of gamma irradiation on the optical spectrum... Polymer based on (polyethyl-methacrylate) (PEMA) were exposed to different doses of gamma radiation up to 100 kGy and the physical properties have been studied. The effects of gamma irradiation on the optical spectrum of PEMA films have been investigated using spectrophotometric measurements of reflectance and transmittance in the wavelength range 200-1100 nm. The structure of the sample is analyzed by X-ray diffraction technique and is found to be amorphous and partially crystalline. TGA studies revealed that the thermal stability of polyethyl methacrylate, improved after irradiation doses up to 100 kGy. On other hand driving absorption coefficient α(ω), consequently the band tail width Ee and optical band gap estimated. This behavior is believed to be associated with the generation of excess of electronic localized states. Also, Optical constants such as refractive index (n), extinction coefficient (K) have been determined using Swanepole method. Optical dispersion parameters and the dispersion parameters, such as Eo (single–oscillator energy), Ed (dispersive energy) are discussed in terms of the single-oscillator Wemple-DiDomenico model. 展开更多
关键词 Gamma Radiation PEMA X-Ray Diffraction Technique opticAL parameters Dispersion parameters TGA theRMOGRAVIMETRIC
下载PDF
An investigation on the magneto-optic properties of terbium gallium garnet under high magnetic field
12
作者 杨国 张国营 +3 位作者 高娇 薛刘萍 夏天 张学龙 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第1期631-638,共8页
This paper reports that a series of Nd3+:Er3+:yb3+ co-doped borosilicate glasses have been prepared and their absorption spectra measured. The J-O intensity parameters Ωk (k = 2, 4, 6), spontaneous radiative l... This paper reports that a series of Nd3+:Er3+:yb3+ co-doped borosilicate glasses have been prepared and their absorption spectra measured. The J-O intensity parameters Ωk (k = 2, 4, 6), spontaneous radiative lifetime Trad, spontaneous transition probability A, fluorescence branching ratio β and oscillator strength fed of the Nd3+ ions at room temperature are calculated based on Judd-Ofelt (J-O) theory. The temperature dependence of the up-conversion photoluminescence characteristics in a Nd3+:Er3+:Yb3+ co-doped sample is studied under a 978 nm semiconductor laser excitation, and the energy transfer mechanisms among Yb3+, Er3+ and Nd3+ ions are analysed. The results show that the J-O intensity parameters Ω2 increase when the Nd3+ concentration of the Nd3+:Er3+:yb3+ co-doped borosilicate glasses increases. The possibility of spontaneous transition is small and lifetimes are long at levels of 4F5/2 and 4F3/2. The intensity of Nd3+ emissions at 595, 691, 753, 813 and 887 nm axe markedly enhanced when the sample temperature exceeds 400 K. The reasons being the cooperation of the secondary sensitization from Era+ to Nd3+ and the contribution of a multi-phonon. 展开更多
关键词 Nd3+:Er3+:yb3+ co-doped borosilicate glasses optical parameters photoluminescence characteristics high temperature
下载PDF
An Optical Disdrometer for Measuring Present Weather Parameters
13
作者 JIA Sheng-Jie Lü Da-Ren XUAN Yue-Jian 《Atmospheric and Oceanic Science Letters》 CSCD 2014年第6期559-563,共5页
A new present weather identifier(PWI) based on occlusion and scattering techniques is presented in the study. The present weather parameters are detectable by the meteorological optical range(MOR) approximately up to ... A new present weather identifier(PWI) based on occlusion and scattering techniques is presented in the study. The present weather parameters are detectable by the meteorological optical range(MOR) approximately up to 50 km and by droplets with diameters ranging from 0.125 mm to 22 mm with velocities up to 16 m s-1. The MOR error is less than 8% for the MOR within 10 km and less than 15% for farther distances. Moreover, the size errors derived from various positions of the light sheet by the particles were checked within ± 0.1 mm ± 5%. The comparison shows that the MOR, in a sudden shower event, is surprisingly consistent with those of the sentry visibility sensors(SVS) with a correlation coefficient up to 98%. For the rain amounts derived from the size and velocity of the droplets, the daily sums by the PWI agree within 10% of those by the Total Rain Weighing Sensor(TRwS205) and the rain gauge. Combined with other sensors such as temperature, humidity, and wind, the PWI can serve as a present weather sensor to distinguish several weather types such as fog, haze, mist, rain, hail, and drizzle. 展开更多
关键词 present weather parameters present weather identifier precipitation measurement hydrometeor classification meteorological optical range
下载PDF
Experimental Study of Multi Optical Parameter Imaging Technology under the Fog Condition
14
作者 Weiwei Feng Ligang Chen 《Optics and Photonics Journal》 2017年第8期86-91,共6页
A multi optical parametric imaging system is introduced and established in order to improve the contrast of object in the fog. A few targets are observed in the fog weather based on the system level radiation model of... A multi optical parametric imaging system is introduced and established in order to improve the contrast of object in the fog. A few targets are observed in the fog weather based on the system level radiation model of multi optical parametric imaging and the calibrated model parameters. The results show that the building’s windows can be distinguished clear in the linear polariza-tion, circular polarization and angle of polarization images because of the strong reflected polarization light of the glass;The vehicles in intersection can hardly be seen in the intensity image, and it is fuzzy in degree of linear polarization and angle of polarization image because of the doped polarization information of trees near in fog;The circular polarization image raises the contrast of the vehicles by 20% because the circle polarization of the trees is less in the fog. 展开更多
关键词 MULTI opticAL PARAMETER Radiation Model POLARIZATION Imaging
下载PDF
Synthesis and study the influence of yttrium doping on band structure,optical,non-linear optical and dielectric results for Ca_(12)Al_(14)O_(33) (C12A7) single crystals grown using traveling-solvent floating zone (TSFZ) method
15
作者 A.Abdel Moez Ahmed I.Ali A.Tayel 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第1期626-630,共5页
Ca_(12)Al_(14)O_(33)(C12A7)and Y_(0.02)Ca_(11.98)Al_(14)O_(33)(Y-C12A7)single crystals were grown by using the traveling-solvent floating zone(TSFZ)method.The temperature was increased to avoid the bubbles and cracks ... Ca_(12)Al_(14)O_(33)(C12A7)and Y_(0.02)Ca_(11.98)Al_(14)O_(33)(Y-C12A7)single crystals were grown by using the traveling-solvent floating zone(TSFZ)method.The temperature was increased to avoid the bubbles and cracks which may be formed during the preparation of the ingot material.We have started with the flux higher than the normal to avoid the bubbles and make good treatment for the solid-liquid interface.The structures of both Ca_(12)Al_(14)O_(33)(C12A7)and Y_(0.02)Ca_(11.98)Al_(14)O_(33)(Y-C12A7)were studied by using x-ray diffraction(XRD).Optical properties for C12A7 and Y-C12A7 single crystals have been studied in order to determine the optical parameters such as optical energy gap(Eg),refractive index n,oscillating energy(Eo),dispersion energy(Ed),volume energy loss function(VELF),and surface energy loss function(SELF).Finally,a new result for these samples is that the third-order nonlinear optical susceptibility(χ(3))was determined.The results have been discussed with effect of Y-doping on the C12A7 single crystals for optical and industrial applications. 展开更多
关键词 syntheses Ca_(12)Al_(14)O_(33)(C12A7)single crystals Y-doping optical parameters dielectric results nonlinear optical susceptibility
下载PDF
Optical Characterization of (TMA)<sub>2</sub>ZnCl<sub>4</sub>Single Crystals in the Normal Phase
16
作者 A. Abu El-Fadl M. Almokhtar A. M. Nashaat 《Open Journal of Applied Sciences》 2015年第4期169-181,共13页
The transmittance (T) and the reflectance (R) were measured for (TMA)2ZnCl4 single crystals and hence the absorption coefficient (α), extinction coefficient (Kex.), refractive index (n), real and im-aginary dielectri... The transmittance (T) and the reflectance (R) were measured for (TMA)2ZnCl4 single crystals and hence the absorption coefficient (α), extinction coefficient (Kex.), refractive index (n), real and im-aginary dielectric constants (ε', ε") of (TMA)2ZnCl4 crystals were calculated as a function of photon energy. The analysis of the spectra behavior of the absorption coefficient in the absorption region revealed indirect transition. The dispersion of the refractive index is discussed in terms of the sin-gle oscillator Wemple-DiDomenico model. The single oscillator energy (E0), the dispersion energy (Ed), the lattice dielectric constant (εL) and the ratio of free charge carrier concentration to the ef-fective mass (N/m*) were estimated. The FTIR spectra were recorded to study the functional groups of the as grown and annealed samples. 展开更多
关键词 (TMA)2ZnCl4 Single CRYSTALS optical Band Gap Refractive Index Dispersion parameters FTIR Spectroscopy
下载PDF
Study on Stereometric Parameters of Optic Nerve Head of Normal, Big-cupped Disk and Glaucomatous Eyes Using Heidelberg Retina Tomograph
17
作者 Xing liu, Yunlan Ling, Xiaoping Zheng, Jingjing HuangZhongshan Ophthalmic Center, Sun Yat-sen University of Medical Sciences, Guangzhou 510060, China 《眼科学报》 2000年第3期163-167,共5页
Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 ... Purpose: To investigate the difference of stereometric parameters of optic nerve head between the normal subjects and patients with big-cupped disk and primary open angle glaucoma (POAG).Methods: Twenty-two cases (44 eyes) of normal subjects, 17 cases (34 eyes) of patients with big-cupped disk and 19 cases (37 eyes) of patients with POAG underwent Heidelberg Retina Tomograph (HRT) examination to get topography images and stereometric parameters of optic nerve head.Results: The stereometric parameters of optic nerve head of the normal, patients with big-cupped disk and POAG were 1) disk area (mm2): 1. 995± 0. 501, 2. 407±0. 661 and 2. 248±0.498; 2) cup area (mm2): 0.573±0.264, 1. 095±0. 673 and 1. 340±0. 516; 3) cup/disk ratio: 0. 25±0. 095, 0. 428±0. 176 and 0. 589±0.195; 4) rim area (mm2): 1.461±0.328, 1.312±0.418 and 0. 905± 0.409; 5)cup volume (mm3): 0. 108±0. 073, 0. 347±0. 346 and 0. 550 ±0. 394; 6) rim volume (mm3): 0. 421±0. 111, 0. 378±0. 225 and 0. 224±0. 189; 7) mean cup 展开更多
关键词 青光眼 视网膜图 视乳头杯 视神经乳头
下载PDF
Effects of preparation parameters on growth and properties of β-Ga_(2)O_(3) film 被引量:3
18
作者 陈子豪 王永胜 +8 位作者 张宁 周兵 高洁 吴艳霞 马永 黑鸿君 申艳艳 贺志勇 于盛旺 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期440-447,共8页
The Ga_(2)O_(3) films are deposited on the Si and quartz substrates by magnetron sputtering, and annealing. The effects of preparation parameters(such as argon–oxygen flow ratio, sputtering power, sputtering time and... The Ga_(2)O_(3) films are deposited on the Si and quartz substrates by magnetron sputtering, and annealing. The effects of preparation parameters(such as argon–oxygen flow ratio, sputtering power, sputtering time and annealing temperature)on the growth and properties(e.g., surface morphology, crystal structure, optical and electrical properties of the films) are studied by x-ray diffractometer(XRD), scanning electron microscope(SEM), and ultraviolet-visible spectrophotometer(UV-Vis). The results show that the thickness, crystallization quality and surface roughness of the β-Ga_(2)O_(3) film are influenced by those parameters. All β-Ga_(2)O_(3) films show good optical properties. Moreover, the value of bandgap increases with the enlarge of the percentage of oxygen increasing, and decreases with the increase of sputtering power and annealing temperature, indicating that the bandgap is related to the quality of the film and affected by the number of oxygen vacancy defects. The I–V curves show that the Ohmic behavior between metal and β-Ga_(2)O_(3) films is obtained at 900℃. Those results will be helpful for the further research of β-Ga_(2)O_(3) photoelectric semiconductor. 展开更多
关键词 β-Ga_(2)O_(3) magnetron sputtering growth parameters optical and electrical properties
下载PDF
Optical remote sensing image characteristics of large amplitude convex mode-2 internal solitary waves:an experimental study
19
作者 Zhixin Li Meng Zhang +1 位作者 Keda Liang Jing Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2023年第6期16-23,共8页
A series of experiments are designed to propose a new method to study the characteristics of convex mode-2internal solitary waves(ISWs)in optical remote sensing images using a laboratory-based optical remote sensing s... A series of experiments are designed to propose a new method to study the characteristics of convex mode-2internal solitary waves(ISWs)in optical remote sensing images using a laboratory-based optical remote sensing simulation platform.The corresponding wave parameters of large-amplitude convex mode-2 ISWs under smooth surfaces are investigated along with the optical remote sensing characteristic parameters.The mode-2 ISWs in the experimentally obtained optical remote sensing image are produced by their overall modulation effect on the water surface,and the extreme points of the gray value of the profile curve of bright-dark stripes appear at the same location as the real optical remote sensing image.The present data extend to a larger range than previous studies,and for the characteristics of large amplitude convex mode-2 ISWs,the experimental results show a second-order dependence of wavelength on amplitude.There is a close relationship between optical remote sensing characteristic parameters and wave parameters of mode-2 ISWs,in which there is a positive linear relationship between the bright-dark spacing and wavelength and a nonlinear relationship with the amplitude,especially when the amplitude is very large,there is a significant increase in bright-dark spacing. 展开更多
关键词 mode-2 internal solitary waves optical remote sensing characteristic parameter wave characteristic
下载PDF
Role of Retinal Nerve Fiber Layer Thickness and Optic Disk Measurement by OCT onEarly Diagnosis of Glaucoma 被引量:3
20
作者 Zanmei Hua Qiuyun Fang +2 位作者 Xiangyin Sha Ruiming Yang Zuopeng Hong 《Eye Science》 CAS 2015年第1期7-12,共6页
Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal ner... Purpose:.Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography.(OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters.A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer(RNFL) thickness and the optic disc tomography by spectraldomain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma(POAG).Methods:.This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control(n=51, 98 eyes), suspected glaucoma(n=81,.146 eyes), and POAG groups(n=55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness,.disc area(DA), cup area(CA), rim area(RA), disc volume(DV),cup volume(CV), rim volume(RV), cup / disc area ratio(CA / DA), rim / disc area ratio(RA / DA), cup / disc volume ratio(CV / DV) and rim / disc volume ratio(RV / DV).Results: Superior, nasal, and mean RNFL parameters, DA,CA,RA, DV, CV, CA / DA, RA / DA, CV / DV and RV / DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group,.the maximum area under the ROC curve(AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA / DA(0.998), followed by CA / DA(0.997). The AROC of CA, RA, CV, and DV were all > 0.900.Conclusion:.OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG. 展开更多
关键词 视神经损伤 厚度控制 早期诊断 青光眼 视网膜 纤维层 华侨城 视盘
下载PDF
上一页 1 2 104 下一页 到第
使用帮助 返回顶部