期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Thermal Characterization of Concrete and Cement Mortar from Construction Sites and Industrial Production Units in the City of Ouagadougou with a View to Standardization in Energy Certification
1
作者 Saïdou Bamogo Fati Zoma +1 位作者 Etienne Malbila David Y. K. Toguyeni 《Engineering(科研)》 2023年第6期396-415,共20页
The present study allowed to carry out a thermal characterization of concrete and cement mortar. Thermal tests were carried out with the KD2 Pro device, on concrete and mortar samples taken from twenty-six (26) constr... The present study allowed to carry out a thermal characterization of concrete and cement mortar. Thermal tests were carried out with the KD2 Pro device, on concrete and mortar samples taken from twenty-six (26) construction sites of office buildings and two (2) industrial production units in the city of Ouagadougou. The tests were carried out on rectangular specimens after four weeks (4) of conservation on the site of construction or production of materials. This study seeks to determine the thermal properties of the materials, in particular the thermal conductivity, the thermal diffusivity and the thermal capacity of the samples, in the real conditions of execution of the buildings and environment. The thermal conductivity varies from 1.413 to 1.965 W/m·K, 0.940 - 1.658 W/m·K and 0.703 - 1.149 W/m·K respectively for concrete, cinder block mortar and plaster mortar. Regarding the other properties, especially the capacity and thermal diffusivity, the values vary respectively, from 1070.59 - 1974.67 kJ/kg·K and (3.74 - 6.70) × 10-7</sup> m2</sup>/s for concrete, from 1123.69 - 1586.81 kJ/kg·K and (3.38 - 5.65) × 10<sup>-</sup>7</sup> m2</sup>/s for plaster mortar and 1202.51 - 1736.01 kJ/kg·K and (3.82 - 7.36) × 10-7</sup> m2</sup>/s for the mortar of building blocks. The conductivity, capacity and thermal diffusivity of industrial mortar vary from 1.019 - 1.229 W/m·K, 792.18 - 1862.58 J/kg·K and (2.75 - 6.80) × 10-7</sup> m2</sup>/s, respectively. Only the correlations made between the thermal properties and the density of the samples of the plaster mortar, give good relations namely R2</sup> = 0.9308 for the thermal conductivity, R2</sup> = 0.7823 for the thermal capacity and R2</sup> = 0.9272 for the thermal diffusivity. This study contributes to the establishment of a thermal regulation in Burkina Faso for the adoption of the West African Economic and Monetary Union (WAEMU) Directive 05 on energy efficiency in buildings. 展开更多
关键词 CONCRETE MORTAR thermal Conductivity thermal capacity thermal Diffusivity
下载PDF
Numerical simulation on thermal accumulation of cemented tailings backfill 被引量:3
2
作者 ZHANG Xiao-yan ZHAO Min +4 位作者 LIU Lang HUAN Chao SONG KI-IL XU Mu-yan WEN De 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第7期2221-2237,共17页
Based on the collaborative exploitation of deep mineral resources and geothermal resources, the thermal accumulation process of cemented tailings backfill(CTB) was studied by numerical simulation. The effects of therm... Based on the collaborative exploitation of deep mineral resources and geothermal resources, the thermal accumulation process of cemented tailings backfill(CTB) was studied by numerical simulation. The effects of thermal accumulation time, slurry proportions and temperature conditions on the thermal accumulation of backfill are analyzed, the influence of the heat conduction between backfill and surrounding rock, the heat convection between backfill and airflow on thermal accumulation were compared simultaneously. The results show that the total thermal accumulation capacity increases by approximately 85% within 10-90 d. The influence of surrounding rock temperature and initial temperature on total thermal accumulation capacity is more significant and it is approximately 2 times of the influence of slurry proportions under the conditions of this study. It is clear that the rise of surrounding rock temperature and the decrease of initial temperature can improve the thermal accumulation capacity more effectively. Moreover, the heat conduction accounts for a considerable proportion in the process of thermal accumulation, the average heat conduction capacity is approximately 25 times of the heat convection capacity. This study can provide the theoretical basis and application reference for the optimization of thermal accumulation process of CTB in the exploitation of geothermal resources. 展开更多
关键词 cemented tailings backfill thermal accumulation heat conduction heat convection total thermal accumulation capacity
下载PDF
Anomalous low-temperature heat capacity in antiperovskite compounds
3
作者 Xin-Ge Guo Jian-Chao Lin +5 位作者 Peng Tong Shuai Lin Cheng Yang Wen-Jian Lu Wen-Hai Song Yu-Ping Sun 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期370-374,共5页
The low-temperature heat capacities are studied for antiperovskite compounds AX M_3(A = Al, Ga, Cu, Ag, Sn, X = C,N, M = Mn, Fe, Co). A large peak in(C- γ T)/T^3 versus T is observed for each of a total of 18 com... The low-temperature heat capacities are studied for antiperovskite compounds AX M_3(A = Al, Ga, Cu, Ag, Sn, X = C,N, M = Mn, Fe, Co). A large peak in(C- γ T)/T^3 versus T is observed for each of a total of 18 compounds investigated,indicating an existence of low-energy phonon mode unexpected by Debye T^3 law. Such a peak is insensitive to the external magnetic field up to 80 k Oe(1 Oe = 79.5775 A·m-1). For compounds with smaller lattice constant, the peak shifts towards higher temperatures with a reduction of peak height. This abnormal peak in(C- γ T)/T^3 versus T of antiperovskite compound may result from the strongly dispersive acoustic branch due to the heavier A atoms and the optical-like mode from the dynamic rotation of X M_6 octahedron. Such a low-energy phonon mode may not contribute negatively to the normal thermal expansion in AX M_3 compounds, while it is usually concomitant with negative thermal expansion in open-structure material(e.g., ZrW_2O_8, Sc F_3). 展开更多
关键词 low-temperature heat capacity low-energy phonon modes antiperovskite compound negative thermal expansion
下载PDF
The Solving of the Inverse Thermal Conductivity Problem for Study the Short Linear Heat Pipes
4
作者 Arkady Vladimirovich Seryakov 《Engineering(科研)》 2022年第6期185-216,共32页
The results of studies by solving the inverse thermal conductivity problem of the heat capacity of evaporator of the short linear heat pipes (HP’s) with a Laval nozzle-liked vapour channel and intended for cooling sp... The results of studies by solving the inverse thermal conductivity problem of the heat capacity of evaporator of the short linear heat pipes (HP’s) with a Laval nozzle-liked vapour channel and intended for cooling spacecraft and satellites with strict take-off mass regulation are presented. Mathematical formulation of the inverse problem for the HP’s thermal conductivity in one-dimensional coordinate system is accompanied by the measurement results using the monotonic heating method in a vacuum adiabatic calorimeter the HP’s surface temperatures along the longitudinal axis over the entire temperature load range, thermal resistance, and arrays of thermal power data on the evaporator Q<sub>ev</sub> and vortex flow calorimeter Q<sub>cond</sub> for the condensation surface allow us to estimate the average value of the evaporator heat capacity C<sub>ev</sub> by solving the inverse thermal conductivity problem in the HP’s evaporator region. Since at the beginning of working fluid boiling for a certain time interval, the temperature of the capillary-porous evaporator remains close to constant, and with the continuation of heating and by solving the inverse thermal conductivity problem, it becomes possible to calculate the heat capacity of the working evaporator and the evaporation specific heat of the boiling working fluid and compare it with the table values. 展开更多
关键词 Short Linear HP’s The Inverse Problem of thermal Conductivity The Monotonic Heating Method thermal Resistance and Heat capacity
下载PDF
The shortest period of coal spontaneous combustion on the basis of oxidative heat release intensity 被引量:5
5
作者 Yang Yongliang Li Zenghua +3 位作者 Hou Shisong Gu Fanjun Gao Siyuan Tang Yibo 《International Journal of Mining Science and Technology》 SCIE EI 2014年第1期99-103,共5页
It’s necessary to forecast the shortest spontaneous combustion period for preventing and controlling the coal spontaneous combustion.During the experimental process,a calculating model of the SSCP is established on t... It’s necessary to forecast the shortest spontaneous combustion period for preventing and controlling the coal spontaneous combustion.During the experimental process,a calculating model of the SSCP is established on the basis of the oxidative heat release intensity and thermal capacity at different temperatures.According to the basic parameters of spontaneous combustion,heat of water evaporation and gas desorption,the SSCPs of different coals are further predicted.Finally,this study analyzed the relationships of the SSCP and the judging indexes of the self-ignite tendency.The result shows that the SSCP non-linearly increases with the decrease of dynamic oxygen adsorption and increase of activation energy.Compared with the practical fire situation of mine,this reliable method can meet the actual requirement of mine production. 展开更多
关键词 Coal spontaneous combustion The shortest period of spontaneouscom bustion Heat release intensity of coal oxidation thermal capacity Judging indexes
下载PDF
Comparing phreatic evaporation at zero water table depth with water surface evaporation
6
作者 HU Shunjun GAN Yongde CHEN Yongbao 《Journal of Arid Land》 SCIE CSCD 2018年第6期968-976,共9页
Salt-affected soils are mostly found in irrigated areas within arid and semi-arid regions where the groundwater table is shallow.Soils of this type have become an increasingly severe problem because they threaten both... Salt-affected soils are mostly found in irrigated areas within arid and semi-arid regions where the groundwater table is shallow.Soils of this type have become an increasingly severe problem because they threaten both the environment and the sustainable development of irrigated agriculture.A tool to estimate phreatic evaporation is therefore urgently required to minimize the salinization potential of salt-affected areas.In this context,phreatic evaporation at zero water table depth(E0)is a key parameter for establishing a model for calculating phreatic evaporation.The aim of this study was to explore the law of phreatic evaporation and to develop structurally rational empirical models for calculating phreatic evaporation,based on E0data of six types of soil(i.e.,gravel,fine sand,sandy loam,light loam,medium loam,and heavy loam)observed using the non-weighing lysimeter and water surface evaporation(E601)data observed using a E601 evaporator of same evaporation area with a lysimeter-tube at the groundwater balance station of the Weigan River Management Office in Xinjiang Uygur Autonomous Region,China,during the non-freezing period(April to October)between 1990 and 1994.The relationship between E0and E601was analyzed,the relationship between the ratio of E0to E601and the mechanical compositions of different soils was presented,and the factors influencing E0were discussed.The results of this study reveal that E0is not equal to E601.In fact,only values of the former for fine sand are close to those of the latter.Data also show that E0values are related to soil texture as well as to potential atmospheric evaporation,the ratio of E0to E601and the silt-clay particle content(grain diameter less than 0.02 mm)is negatively exponentially correlated,and that soil thermal capacity plays a key role in phreatic evaporation at E0.The results of this analysis therefore imply that the treatment of zero phreatic depth is an essential requirement when constructing groundwater balance stations to study the law of phreatic evaporation. 展开更多
关键词 phreatic evaporation water table depth water surface evaporation soil texture soil thermal capacity
下载PDF
Super Performance InGaP/GaAs HBT with Novel Structure 被引量:6
7
作者 白大夫 刘训春 +2 位作者 王润梅 袁志鹏 孙海锋 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2004年第7期756-761,共6页
A kind of super performance InGaP/GaAs HBT with f T=108GHz and f max =140GHz is demonstrated.The excellent frequency performance results from the novel structure of the U shaped emitter,together with sel... A kind of super performance InGaP/GaAs HBT with f T=108GHz and f max =140GHz is demonstrated.The excellent frequency performance results from the novel structure of the U shaped emitter,together with self aligned emitter and LEU(lateral etched undercut) technologies.The HBT with the novel structure shows a distinguished performance with BV CEO up to 25V.And excellent performance of low V offset of 105mV and V knee of 0 50V is great favor of low power applications.The differences due to the different structure are also compared. 展开更多
关键词 heterojunction bipolar transistor U shaped emitter self aligned emitter thermal handling capacity
下载PDF
Impacts of solar multiple on the performance of direct steam generation solar power tower plant with integrated thermal storage 被引量:2
8
作者 Yah LUO Xiaoze DU +2 位作者 Lijun YANG Chao XU Muhammad AMJAD 《Frontiers in Energy》 SCIE CSCD 2017年第4期461-471,共11页
Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and therm... Solar multiple (SM) and thermal storage capacity are two key design parameters for revealing the performance of direct steam generation (DSG) solar power tower plant. In the case of settled land area, SM and thermal storage capacity can be optimized to obtain the minimum levelized cost of electricity (LCOE) by adjusting the power generation output. Taking the dual-receiver DSG solar power tower plant with a given size of solar field equivalent electricity of 100 MWe in Sevilla as a reference case, the minimum LCOE is 21.77 /kWhe with an SM of 1.7 and a thermal storage capacity of 3 h. Besides Sevilla, two other sites are also introduced to discuss the influence of annual DNI. When compared with the case of Sevilla, the minimum LCOE and optimal SM of the San Jose site change just slightly, while the minimum LCOE of the Bishop site decreases by 32.8% and the optimal SM is reduced to 1.3. The influence of the size of solar field equivalent electricity is studied as well. The minimum LCOE decreases with the size of solar field, while the optimal SM and thermal storage capacity still remain unchanged. In addition, the sensitivity of different investment in sub-system is investigated. In terms ofoptimal SM and thermal storage capacity, they can decrease with the cost of thermal storage system but increase with the cost of power generation unit. 展开更多
关键词 direct steam generation solar power tower solar multiple thermal energy storage capacity levelizedcost of electricity (LCOE)
原文传递
A Reexamination of Methods of Hierarchic Composition in the AHP 被引量:7
9
作者 ZHANG Zhi-yong Economics and Management Department, Xi′an Petroleum University, Xi′an 710065, Shaanxi Province, China 《Systems Science and Systems Engineering》 CSCD 2002年第4期503-510,共8页
This paper demonstrates that we should use two different hierarchic composition methods for the two different types of levels in the AHP. The first method is using the weighted geometric mean to synthesize the judgmen... This paper demonstrates that we should use two different hierarchic composition methods for the two different types of levels in the AHP. The first method is using the weighted geometric mean to synthesize the judgments of alternative-type-level elements, which is the only hierarchic composition method for the alternative-type level in an AHP hierarchy, and the rank is preserved automatically. The second one is using the weighted arithmetic mean to synthesize the priorities of the criteria-type-level elements, which is the only hierarchic composition method for all the criteria-type levels, and rank reversals are allowed. 展开更多
关键词 analytic hierarchy process multicriteria analysis decision theory hierarchic composition priority synthesis rank preservation and reversal of the soil thermodynamic parameters such as the soil thermal conductivity soil heat capacity so
原文传递
上一页 1 下一页 到第