期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Prognostic value of cortisol and thyroid function tests in poisoned patients admitted to toxicology ICU 被引量:7
1
作者 Shahin Shadnia Nasim Zamani +3 位作者 Hossein Hassanian-Moghaddam Hamed Shafaroodi Mina Padandar Mohammad Hasan Rezaeizadeh 《World Journal of Emergency Medicine》 SCIE CAS 2018年第1期51-55,共5页
BACKGROUND: Prognostic value of cortisol and thyroid function tests(TFTs) has previously been evaluated in medical ICUs. We aimed to evaluate prognostic efficacy of cortisol and TFTs in critically ill poisoned patient... BACKGROUND: Prognostic value of cortisol and thyroid function tests(TFTs) has previously been evaluated in medical ICUs. We aimed to evaluate prognostic efficacy of cortisol and TFTs in critically ill poisoned patients admitted to toxicology intensive care unit(ICU).METHODS: In a prospective study of consecutively enrolled subjects admitted to the toxicology ICU, lab analyses included TFTs(total T3 and T4 as well as TSH) and cortisol levels drawn between 8 am–10 am during period of the first 24 hours post-ingestion/exposure. Simplified Acute Physiology Score Ⅱ(SAPS Ⅱ) and Acute Physiology and Chronic Health Evaluation Ⅱ(APACHE Ⅱ) were recorded. All scores were compared to detect the best prognostic factor. Type of poisoning was also included.RESULTS: In 200 patients evaluated, 129 were male and mean age was 31 years. In general, SAPS Ⅱ, T4, and cortisol could prognosticate death. After regression analysis, only cortisol had such efficacy(P=0.04; OR=1.06; 95%CI=1.05–1.08; cut-off=42 μg/d L; sensitivity=70%; specificity=82%). Between aluminium phosphide(ALP)-and non ALP-poisoned patients, level of consciousness, mean arterial pressure, and cortisol level could prognosticate death in ALP poisoning(all Ps<0.001 in both uni and multivariate analyses). Median(interquartile range; IQR) GCS was 7(6, 10) and 15(8, 15) in non-ALP and ALP-poisoned patients(P<0.003). SAPS Ⅱ and APACHE Ⅱ could not prognosticate death at all.CONCLUSION: Cortisol best prognosticated outcomes for subjects admitted to the toxicology ICU. Its level is higher in ALP-poisoned patients probably due to the higher stress while they remain conscious till the final stages of toxicity and are aware of deterioration of their clinical condition or may be due to their significantly lower blood pressures. 展开更多
关键词 PROGNOSIS Intensive care unit CORTISOL thyroid function tests POISONING
下载PDF
Protective effect of thyroid and restores of ovarian function of Buzhong Yiqi granule(补中益气颗粒)on experimental autoimmune thyroiditis in female rats
2
作者 WANG Yuezhu ZHANG Yuyang +2 位作者 QIAO Jiajun LU Yuyuan XIA Zhongyuan 《Journal of Traditional Chinese Medicine》 SCIE CSCD 2024年第2期315-323,共9页
OBJECTIVE:To observe the effects of Buzhong Yiqi granule(补中益气颗粒)on thyroid function and ovarian function in rats with experimental autoimmune thyroiditis(EAT).METHODS:EAT model was replicate by using the method ... OBJECTIVE:To observe the effects of Buzhong Yiqi granule(补中益气颗粒)on thyroid function and ovarian function in rats with experimental autoimmune thyroiditis(EAT).METHODS:EAT model was replicate by using the method of mixing and injecting porcine thyroglobulin with Freund's adjuvant and high iodine.Rats were randomly divided into normal control(NC)group,EAT model(EAT)group,selenium yeast(PC)group,low dose Buzhong Yiqi(BZYQ-L)group,medium dose Buzhong Yiqi(BZYQ-M)group and high dose Buzhong Yiqi(BZYQ-H)group.After two months of drug intervention according to dosage,enzyme-linked immunosorbent assay(ELISA)was used to measure the levels of free triiodothyronine(FT3),free thyroxine(FT4),thyroid-stimulating hormone(TSH),antithyroid peroxidase antibody(TPOAb),thyroglobulin antibody(TGAb)in peripheral blood of rats.The pathological changes of rat thyroid tissues were observed under light microscope with HE staining;ELISA was used to determine estradiol(E2),follicle-stimulating hormone(FSH),luteinizing hormone(LH),testosterone(T),antimüllerian hormone(AMH),and the pathological changes of rat ovarian tissues were observed under light microscope with hematoxylin and eosin staining.RESULTS:Compared with the NC group,BZYQ granule improved the thyroid and ovarian tissue morphology,and the levels of TPOAb,TGAb and TSH in the model group rats significantly increased(P<0.05),the thyroid tissue was severely destroyed,the levels of E2,FSH,LH,T,AMH significantly increased(P<0.05),and the ovary exhibited polycystic changes;Compared with the model group,TSH level in the BZYQ-L group rats decreased(P<0.05),FSH,T,AMH levels decreased(P<0.05),in the BZYQ-M group TPOAb,TSH levels decreased(P<0.05),FSH,LH,T,AMH levels significantly decreased(P<0.05),BZYQ-H group TPOAb,TGAb,TSH levels significantly decreased(P<0.05),FSH,LH,T,AMH levels significantly decreased(P<0.05),with the greatest improvement and significantly better than selenium yeast group(P<0.05).CONCLUSIONS:BZYQ granule could regulate the thyroid function of EAT rats,reduce thyroid antibody titers,then act on the ovarian function,regulate hormone disorders,and alleviate the pathological damage of rat's ovarian tissues.The effect of high dose Buzhong Yiqi granule is the best. 展开更多
关键词 thyroidITIS AUTOIMMUNE thyroid function tests gonadal steroid hormones thyroid antibody Buzhong Yiqi granule
原文传递
Comparison of the Reference Intervals Used for the Evaluation of Maternal Thyroid Function During Pregnancy Using Sequential and Nonsequential Methods 被引量:6
3
作者 Jian-Xia Fan Shuai Yang +2 位作者 Wei Qian Feng-Tao Shi He-Feng Huang 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第7期785-791,共7页
Background: Maternal thyroid dysfunction is common during pregnancy, and physiological changes during pregnancy can lead to the overdiagnosis of hyperthyroidism and misdiagnosis of hypothyroidism with nongestation-sp... Background: Maternal thyroid dysfunction is common during pregnancy, and physiological changes during pregnancy can lead to the overdiagnosis of hyperthyroidism and misdiagnosis of hypothyroidism with nongestation-specific reference intervals. Our aim was to compare sequential with nonsequential methods for the evaluation of thyroid function in pregnant women. Methods: We tested pregnant women who underwent their trimester prenatal screening at our hospital from February 2011 to September 2012 for serum thyroid stimulating hormone (TSH) and free thyroxine (FT4) using the Abbott and Roche kits. There were 447 and 200 patients enrolled in the nonsequential and sequential groups, respectively. The central 95% range between the 2.5th and the 97.5th percentiles was used as the reference interval for the thyroid function parameter. Results: The nonsequential group exhibited a significantly larger degree of dispersion in the TSH reference interval during the 2nd and 3rd trimesters as measured using both the Abbott and Roche kits (all P 〈 0.05). The TSH reference intervals were significantly larger in the nonsequential group than in the sequential group during the 3rd trimester as measured with both the Abbott (4.95 vs. 3.77 mU/L, P 〈 0.001) and Roche kits (6.62 vs. 5.01 mU/L, P〈 0.004). The nonsequential group had a significantly larger FT4 reference interval as measured with the Abbott kit during all trimesters ( 12.64 vs. 5.82 pmol/L; 7,96 vs. 4.77 pmol/L; 8.10 vs. 4.77 pmol/L, respectively, all P 〈 0.05), whereas a significantly larger FT4 reference interval was only observed during the 2nd trimester with the Roche kit (7.76 vs. 5.52 pmol/L, P = 0.002). Conclusions: It was more reasonable to establish reference intervals for the evaluation of maternal thyroid function using the sequential method during each trimester of pregnancy. Moreover, the exclusion of pregnancy-related complications should be considered in the inclusion criteria for thyroid function tests. 展开更多
关键词 Nonsequential Pregnancy Trimester Reference Interval SEQUENTIAL thyroid function tests
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部