期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Synthetic tidal parameters for gravity over China and its neighbor area
1
作者 周江存 孙和平 《Acta Seismologica Sinica(English Edition)》 CSCD 2007年第6期656-663,共8页
The synthetic tidal parameters with high spatial resolution for gravity over China and its neighbor area are constructed with Earth's tidal model and ocean tide loading calculated using TPXO7 global ocean tide model ... The synthetic tidal parameters with high spatial resolution for gravity over China and its neighbor area are constructed with Earth's tidal model and ocean tide loading calculated using TPXO7 global ocean tide model as well as tidal data over China seas. The comparison between synthetic parameters and ones observed by spring gravimeters at some seismic network stations and Hong Kong station and one observed by super-conducting gravimeter at Wuhan station shows that the average differences in amplitude factors and phases are smaller than 0.005 and 0.5° respectively; and that the discrepancies between observational and synthetic parameters are dependent on gravimetric technique in that the synthetic parameters are in well agreement with the superconducting gravimetric observations. This also indicates that the synthetic result is a good estimation for tidal gravity, and the numerical results in the present paper not only can provide ground and space gravimetry such as absolute gravimetry with correction model of tidal gravity, but also provide effective tidal parameters over areas where no observation is carried out. 展开更多
关键词 synthetic tidal parameters for gravity Earth's tidal model ocean tide loading TPXO7 ocean tide model tidal data over China seas
下载PDF
Scintrex CG5 used for superconducting gravimeter calibration 被引量:6
2
作者 Bruno Meurers 《Geodesy and Geodynamics》 2018年第3期197-203,共7页
The scale factor accuracy of superconducting gravimeters (SG) can be largely improved by a high repetition rate of calibration experiments. At stations where the availability of absolute gravimeters is limited, care... The scale factor accuracy of superconducting gravimeters (SG) can be largely improved by a high repetition rate of calibration experiments. At stations where the availability of absolute gravimeters is limited, carefully calibrated spring gravimeters can be used for providing the reference signal assuming the irregular drift is properly adjusted. The temporal stability of the SG scale factor is assessable by comparing the temporal variations of M2 tidal parameters observed at neighboring SG sites or from synthetic tide models. Combining these methods reduces the SG scale factor error to a few 0.1%0. The paper addresses the particular procedure required for evaluating the calibration experiments based on spring gravimeters and presents results obtained at Conrad observatory (Austria). Comparing the M2 amplitude factor modulation helped to reveal a SG scale factor offset of about 0.2%0 due to re-installation. 展开更多
关键词 Superconducting gravimeter CG-5 Scintrex gravimeterScale factor Calibration accuracy M2 tidal parameter variation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部