期刊文献+
共找到121篇文章
< 1 2 7 >
每页显示 20 50 100
Tomographic inversion of near-surface Q factor by combining surface and cross-hole seismic surveys 被引量:9
1
作者 李国发 郑浩 +2 位作者 祝文亮 王明超 翟桐立 《Applied Geophysics》 SCIE CSCD 2016年第1期93-102,219,220,共12页
The estimation of the quality factor Q plays a fundamental role in enhancing seismic resolution via absorption compensation in the near-surface layer.We present a new geometry that can be used to acquire field data by... The estimation of the quality factor Q plays a fundamental role in enhancing seismic resolution via absorption compensation in the near-surface layer.We present a new geometry that can be used to acquire field data by combining surface and cross-hole surveys to decrease the effect of geophone coupling on Q estimation.In this study,we drilled number of receiver holes around the source hole,each hole has different depth and each geophone is placed geophones into the bottom of each receiver hole to avoid the effect of geophone coupling with the borehole wall on Q estimation in conventional cross-hole seismic surveys.We also propose a novel tomographic inversion of the Q factor without the effect of the source signature,and examine its stability and reliability using synthetic data.We estimate the Q factors of the near-surface layer in two different frequency bands using field data acquired in the Dagang Oilfield.The results show that seismic absorption in the nearsurface layer is much greater than that in the subsurface strata.Thus,it is of critical practical importance to enhance the seismic solution by compensating for near-surface absorption.In addition,we derive different Q factors from two frequency bands,which can be treated,to some extent,as evidence of a frequency-dependent Q. 展开更多
关键词 near surface Q factor tomographic inversion spectral ratio method frequency dependence
下载PDF
Tomographic inversion for microseismic source parameters in mining 被引量:4
2
作者 缪华祥 姜福兴 +2 位作者 宋雪娟 杨淑华 焦俊如 《Applied Geophysics》 SCIE CSCD 2012年第3期341-348,362,共9页
We propose a new method for inverting source function of microseismic event induced in mining. The observed data from microseismic monitoring during mining are represented by a wave equation in a spherical coordinate ... We propose a new method for inverting source function of microseismic event induced in mining. The observed data from microseismic monitoring during mining are represented by a wave equation in a spherical coordinate system and then the data are transformed from the time-space domain to the time-slowness domain based on tomographic principle, from whichwe can obtain the signals related to the source in the time-slowness domain. Through analyzing the relationship between the signal located at the maximum energy and the source function, we derive the tomographic equations to compute the source function from the signals and to calculate the effective radiated energy based on the source function. Moreover, we fit the real amplitude spectrum of the source function computed from the observed data into the co-2 model based on the least squares principle and determine the zero-frequency level spectrum and the corner frequency, finally, the source rupture radius of the event is calculated and The synthetic and field examples demonstrate that the proposed tomographic inversion methods are reliable and efficient 展开更多
关键词 tomographic image microseismic event source function source spectrum the time-slowness domain
下载PDF
Wave equation tomographic velocity inversion method based on the Born/Rytov approximation 被引量:5
3
作者 张凯 尹正 +1 位作者 李振春 陈永芮 《Applied Geophysics》 SCIE CSCD 2013年第3期314-322,358,359,共11页
This paper discusses Born/Rytov approximation tomographic velocity inversion methods constrained by the Fresnel zone. Calculations of the sensitivity kernel function and traveltime residuals are critical in tomographi... This paper discusses Born/Rytov approximation tomographic velocity inversion methods constrained by the Fresnel zone. Calculations of the sensitivity kernel function and traveltime residuals are critical in tomographic velocity inversion. Based on the Bom/Rytov approximation of the frequency-domain wave equation, we derive the traveltime sensitivity kemels of the wave equation on the band-limited wave field and simultaneously obtain the traveltime residuals based on the Rytov approximation. In contrast to single-ray tomography, the modified velocity inversion method improves the inversion stability. Tests of the near- surface velocity model and field data prove that the proposed method has higher accuracy and Computational efficiency than ray theory tomography and full waveform inversion methods. 展开更多
关键词 tomographic inversion Fresnel zone sensitivity kernels Bom approximation Rytov approximation
下载PDF
Tomographic velocity inversion for ADCIGs in areas with a rugged surface 被引量:2
4
作者 张凯 李振春 +2 位作者 曾同生 秦宁 姚云霞 《Applied Geophysics》 SCIE CSCD 2012年第3期313-318,361,共7页
Pre-stack depth migration velocity analysis is one of the key techniques influencing image quality. As for areas with a rugged surface and complex subsurface, conventional prestack depth migration velocity analysis co... Pre-stack depth migration velocity analysis is one of the key techniques influencing image quality. As for areas with a rugged surface and complex subsurface, conventional prestack depth migration velocity analysis corrects the rugged surface to a known datum or designed surface velocity model on which to perform migration and update the velocity. We propose a rugged surface tomographic velocity inversion method based on angle-domain common image gathers by which the velocity field can be updated directly from the rugged surface without static correction for pre-stack data and improve inversion precision and efficiency. First, we introduce a method to acquire angle-domain common image gathers (ADCIGs) in rugged surface areas and then perform rugged surface tornographic velocity inversion. Tests with model and field data prove the method to be correct and effective. 展开更多
关键词 Rugged surface angle-domain common image gathers tomographic inversion velocity modeling
下载PDF
Tomographic Principle of Multiconjugate Correction in Adaptive Optics
5
作者 阎吉祥 俞信 +1 位作者 赵达尊 周仁忠 《Journal of Beijing Institute of Technology》 EI CAS 1995年第2期159+156-159,共5页
A wavefront sensing and correction correction is proposed that would allow the field of view (FOV) of an adaptive optics spstem to be increased in size by a factor of several tens. This concept is based on the idea of... A wavefront sensing and correction correction is proposed that would allow the field of view (FOV) of an adaptive optics spstem to be increased in size by a factor of several tens. This concept is based on the idea of placing multiple deformable mirrors (DMs) at locations that are conjugate to corresponding. layers of atmospheric turbulence. In order to control properly each DM, a tomographic method for determining the phase distortion contributed by each atmospheric layer has been developed and used in dealing with the circumstance of two layers. 展开更多
关键词 adaptive optics multiconjugate correction tomographic principle
下载PDF
Automatically positioning microseismic sources in mining by the stereo tomographic method using full wavefields 被引量:3
6
作者 缪华祥 姜福兴 +3 位作者 宋雪娟 宋建勇 杨淑华 焦俊如 《Applied Geophysics》 SCIE CSCD 2012年第2期168-176,234,235,共11页
For microseisimic monitoring it is difficult to determine wave modes and their propagation velocity. In this paper, we propose a new method for automatically inverting in real time the source characteristics of micros... For microseisimic monitoring it is difficult to determine wave modes and their propagation velocity. In this paper, we propose a new method for automatically inverting in real time the source characteristics of microseismic events in mine engineering without wave mode identification and velocities. Based on the wave equation in a spherical coordinate system, we derive a tomographic imaging equation and formulate a scanning parameter selection criterion by which the microseisimic event maximum energy and corresponding parameters can be determined. By determining the maximum energy positions inside a given risk district, we can indentify microseismic events inside or outside the risk districts. The synthetic and field examples demonstrate that the proposed tomographic imaging method can automatically position microseismic events by only knowing the risk district dimensions and range of velocities without identifying the wavefield modes and accurate velocities. Therefore, the new method utilizes the full wavefields to automatically monitor microseismic events. 展开更多
关键词 microseismic full wavefields wavefield mode identification tomographic image source parameters automatic positioning
下载PDF
Tomographic PIV investigation of coherent structures in a turbulent boundary layer flow 被引量:15
7
作者 Zhan-Qi Tang Nan Jiang +1 位作者 Andreas Schroder Reinhard Geisler 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第3期572-582,共11页
Tomographic particle image velocimetry was used to quantitatively visualize the three-dimensional co- herent structures in the logarithmic region of the turbulent boundary layer in a water tunnel. The Reynolds number ... Tomographic particle image velocimetry was used to quantitatively visualize the three-dimensional co- herent structures in the logarithmic region of the turbulent boundary layer in a water tunnel. The Reynolds number based on momentum thickness is Reo = 2 460. The in- stantaneous velocity fields give evidence of hairpin vortices aligned in the streamwise direction forming very long zones of low speed fluid, which is flanked on either side by high- speed ones. Statistical support for the existence of hairpins is given by conditional averaged eddy within an increasing spanwise width as the distance from the wall increases, and the main vortex characteristic in different wall-normal re- gions can be reflected by comparing the proportion of ejec- tion and its contribution to Reynolds stress with that of sweep event. The pre-multiplied power spectra and two-point cor- relations indicate the presence of large-scale motions in the boundary layer, which are consistent with what have been termed very large scale motions (VLSMs). The three dimen-sional spatial correlations of three components of veloc- ity further indicate that the elongated low-speed and high- speed regions will be accompanied by a counter-rotating roll modes, as the statistical imprint of hairpin packet structures, all of which together make up the characteristic of coherent structures in the logarithmic region of the turbulent boundary layer (TBL). 展开更多
关键词 tomographic particle image velocimetry Tur-bulent boundary layer Coherent structures Hairpin vortex Very large scale motion
下载PDF
Splanchnic vein thrombosis in necrotizing acute pancreatitis: Detection by computed tomographic venography 被引量:9
8
作者 Wei Jiang Jing Zhou +4 位作者 Lu Ke Gang Li Zhi-Hui Tong Wei-Qin Li Jie-Shou Li 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16698-16701,共4页
AIM: To assess the diagnostic accuracy of computed tomographic venography(CTV) for splanchnic vein thrombosis(SVT) detection in necrotizing acute pancreatitis(AP) patients.METHODS:Forty-three patients with necrotizing... AIM: To assess the diagnostic accuracy of computed tomographic venography(CTV) for splanchnic vein thrombosis(SVT) detection in necrotizing acute pancreatitis(AP) patients.METHODS:Forty-three patients with necrotizing AP who underwent both CTV and digital subtraction angiography(DSA)within 3 d were analyzed in this retrospective comparative study.All CTV procedures were performed with a dual-source CT scanner.The presence and location of SVT were determined via blinded imaging data analyses.RESULTS:According to the DSA results,17(39.5%)of the total 43 patients had SVT.The sensitivity,specificity,positive and negative predictive values of CTV for SVT detection were 100%(95%CI:77.1%-100%),92.3%(95%CI:73.4%-98.7%),89.5%(95%CI:65.5%-98.2%)and 100%(95%CI:82.8%-100%),respectively.CONCLUSION:CTV is an effective examination for SVT detection in patients with necrotizing AP with high positive and negative predictive values. 展开更多
关键词 Splanchnic vein THROMBOSIS Necrotizing acute pancreatitis Computed tomographic venography Digital subtraction angiography
下载PDF
Quantitative Investigation of Tomographic Effects in Abnormal Regions of Complex Structures 被引量:9
9
作者 Longjun Dong Xiaojie Tong Ju Ma 《Engineering》 SCIE EI 2021年第7期1011-1022,共12页
The detection of abnormal regions in complex structures is one of the most challenging targets for underground space engineering.Natural or artificial geologic variations reduce the effectiveness of conventional explo... The detection of abnormal regions in complex structures is one of the most challenging targets for underground space engineering.Natural or artificial geologic variations reduce the effectiveness of conventional exploration methods.With the emergence of real-time monitoring,seismic wave velocity tomography allows the detection and imaging of abnormal regions to be accurate,intuitive,and quantitative.Since tomographic results are affected by multiple factors in practical small-scale applications,it is necessary to quantitatively investigate those influences.We adopted an improved three-dimensional(3D)tomography method combining passive acoustic emission acquisition and active ultrasonic measurements.By varying individual parameters(i.e.,prior model,sensor configuration,ray coverage,event distributions,and event location errors),37 comparative tests were conducted.The quantitative impact of different factors was obtained.Synthetic experiments showed that the method could effectively adapt to complex structures.The optimal input parameters based on quantization results can significantly improve the detection reliability in abnormal regions. 展开更多
关键词 Detection of abnormal regions tomographic effects Wave velocity Ray path
下载PDF
Study on local topology model of low/high streak structures in wall-bounded turbulence by tomographic time-resolved particle image velocimetry 被引量:6
10
作者 Haiping TIAN Nan JIANG +1 位作者 Yongxiang HUANG Shaoqiong YANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2015年第9期1121-1130,共10页
The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry... The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak. 展开更多
关键词 wall turbulence quadrupole topological structure hairpin vortex low/highspeed streak tomographic time-resolved particle image velocimetry (TRPIV) system
下载PDF
Convection and correlation of coherent structure in turbulent boundary layer using tomographic particle image velocimetry 被引量:4
11
作者 王维 管新蕾 姜楠 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期323-333,共11页
The present experimental work focuses on a new model for space-time correlation and the scale-dependencies of convection velocity and sweep velocity in turbulent boundary layer over a flat wail. A turbulent boundary l... The present experimental work focuses on a new model for space-time correlation and the scale-dependencies of convection velocity and sweep velocity in turbulent boundary layer over a flat wail. A turbulent boundary layer flow at Reo = 2460 is measured by tomographic particle image velocimetry (tomographic PIV). It is demonstrated that arch, cane, and hairpin vortices are dominant in the logarithmic layer. Hairpins and hairpin packets are responsible for the elongated low-momentum zones observed in the instantaneous flow field. The conditionally-averaged coherent structures systemically illustrate the key roles of hairpin vortice in the turbulence dynamic events, such as ejection and sweep events and energy transport. The space-time correlations of instantaneous streamwise fluctuation velocity are calculated and confirm the new elliptic model for the space-time correlation instead of Taylor hypothesis. The convection velocities derived from the space-time correlation and conditionally-averaged method both suggest the scaling with the local mean velocity in the logarithmic layer. Convection velocity result based on Fourier decomposition (FD) shows stronger scale- dependency in the spanwise direction than in streamwise direction. Compared with FD, the proper orthogonal decomposition (POD) has a distinct distribution of convection velocity for the large- and small-scales which are separated in light of their contributions of turbulent kinetic energy. 展开更多
关键词 turbulent boundary layer tomographic particle image velocimetry space-time correlation ellipticmodel
下载PDF
Evaluation of contrast-enhanced computed tomographic colonography in detection of local recurrent colorectal cancer 被引量:7
12
作者 Yau-Tong You Chung-Rong Chang Chien +6 位作者 Jeng-Yi Wang Koon-Kwan Ng Jinn-Shiun Chen Reiping Tang Jy-Ming Chiang Chien-Yuh Yeh Pao-Shiu Hsieh 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第1期123-126,共4页
AIM: TO evaluate the diagnostic accuracy, sensitivity, specificity of contrast-enhanced computed tomographic colonography in detecting local recurrence of colorectal cancer. METHODS: From January 2000 to December 20... AIM: TO evaluate the diagnostic accuracy, sensitivity, specificity of contrast-enhanced computed tomographic colonography in detecting local recurrence of colorectal cancer. METHODS: From January 2000 to December 2004, 434 patients after potentially curative resection for invasive colorectal cancer were followed up for a period ranging from 20 to 55 mo. Eighty of the four hundred and thirty-four patients showing strong clinical evidence for recurring colorectal cancer during the last followup were enrolled in this study. Each patient underwent contrast-enhanced computed tomographic colonography and colonoscopy on the same day. Any lesions, biopsies, identified during the colonoscopic examination, immediate complications and the duration of the procedure were recorded. The results of contrast-enhanced computed tomographic colonography were evaluated by comparing to those of colonoscopy, surgical finding, and clinical follow-up. RESULTS: Contrast-enhanced computed tomographic colonography had a sensitivity of 100%, a specificity of 83% and an overall accuracy of 94% in detecting local recurrent colorectal cancer. CONCLUSION: Conventional colonoscopy and contrastenhanced tomographic colonography can complement each other in detecting local recurrence of colorectal cancer. 展开更多
关键词 Computed tomographic colonography Recurrent colorectal cancer
下载PDF
Improvements in seismic event locations in a deep western U.S. coal mine using tomographic velocity models and an evolutionary search algorithm 被引量:7
13
作者 LURKA Adam SWANSON Peter 《Mining Science and Technology》 EI CAS 2009年第5期599-603,共5页
Methods of improving seismic event locations were investigated as part of a research study aimed at reducing ground control safety hazards. Seismic event waveforms collected with a 23-station three-dimensional sensor ... Methods of improving seismic event locations were investigated as part of a research study aimed at reducing ground control safety hazards. Seismic event waveforms collected with a 23-station three-dimensional sensor array during longwall coal mining provide the data set used in the analyses. A spatially variable seismic velocity model is constructed using seismic event sources in a passive tomographic method. The resulting three-dimensional velocity model is used to relocate seismic event positions. An evolutionary optimization algorithm is implemented and used in both the velocity model development and in seeking improved event location solutions. Results obtained using the different velocity models are compared. The combination of the tomographic velocity model development and evolutionary search algorithm provides improvement to the event locations. 展开更多
关键词 seismic event location tomographic velocity model an evolutionary search algorithm
下载PDF
Computed tomographic colonography:Hope or hype? 被引量:3
14
作者 Otto Schiueh-Tzang Lin 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第8期915-920,共6页
Computed tomographic colonography (CTC) is a promising emerging technology for imaging of the colon. This concise review discusses the currently available data on CTC technique,test characteristics,acceptance,safety,c... Computed tomographic colonography (CTC) is a promising emerging technology for imaging of the colon. This concise review discusses the currently available data on CTC technique,test characteristics,acceptance,safety,cost-effectiveness,follow-up strategy,and extracolonic findings. In summary,CTC technique is still evolving,and further research is needed to clarify the role of automated colonic insufflation,smooth-muscle relaxants,intravenous and oral contrast,soft-ware rendering,and patient positioning. Currently,full bowel preparation is still required to achieve optimal results. The sensitivity for detecting large polyps (> 1 cm) can be as high as 85%,with specificity of up to 97%. These test characteristics are almost comparable to those of conventional colonoscopy. Patient acceptance of CTC is generally higher than that for colonoscopy,especially in patients who have never undergone either procedure. CTC is generally safe,although uncommon instances of colonic perforation have been documented. In terms of cost-effectiveness,most decision analyses have concluded that CTC would only be cost-effective if it were considerably cheaper than conventional colonoscopy. The proper follow-up strategy for small polyps or incidental extracolonic findings discovered during CTC is still under debate. At present,the exact clinical role of virtual colonoscopy still awaits determination. Even though widespread CTC screening is not available today,in the future there may eventually be a role for this technology. Technological advances in this area will undoubtedly continue,with multi-detector row CT scanners allowing thinner collimation and higher reso-lution images. Stool-tagging techniques are likely to evolve and may eventually allow for low-preparation CTC. Perceptual and fatigue-related reading errors can potentially be minimized with the help of computer-aided detection software. Further research will define the exact role of this promising technology in our diagnostic armamentarium. 展开更多
关键词 Computed tomographic colonography COLONOSCOPY Colonic neoplasms Cancer screening Colonic polyps
下载PDF
THE HIGH RESOLUTION SEISMIC TOMOGRAPHIC IMAGE IN QINGHAI—TIBET PLATEAU AND ITS DYNAMIC IMPLICATIONS 被引量:2
15
作者 Zhu Jieshou,Cai Xuelin,Cao Jiamin,Yan Zhongqun,Cao Xiaolin,Liang Chuntao 《地学前缘》 EI CAS CSCD 2000年第S1期354-356,共3页
The Qinghai—Tibet plateau and its surrounding areas including Indian subcontinent, Xinjiang, Mongolia, is a largest lithosphere convergence place in the world, which characterized by continent\|continent collision wi... The Qinghai—Tibet plateau and its surrounding areas including Indian subcontinent, Xinjiang, Mongolia, is a largest lithosphere convergence place in the world, which characterized by continent\|continent collision with a thick crust and lithosphere. The high resolution seismic surface wave tomographic inversion has been conducted for studying the 3D velocity structure of crust and upper mantle in those areas. The seismic surface waveform data are from the archives of the CDSN, GSN and GEOSCOPE. About 2400 long period surface waveform recordings are available for both dispersion and waveform tomographic inversion. The block inversion by grid 1°×1°in Qinghai—Tibet plateau and 2°×2°in the surrounding areas were adapted. The resulting maps show the high resolution 3D shear wave velocity variation from earth’s surface to 400km depth. 展开更多
关键词 SEISMIC tomographic IMAGE high resolution DYNAMIC Qinghai—Tibet PLATEAU
下载PDF
Internal Structure of Cambrian Fossil Embryo Markuelia Revealed in the Light of Synchrotron Radiation X-ray Tomographic Microscopy 被引量:5
16
作者 CHENG Gong PENG Fan +1 位作者 DUAN Baichuan DONG Xiping 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2011年第1期81-90,共10页
In the light of Synchrotron Radiation X-ray Tomographic Microscopy (SRXTM), the internal structure of Markuelia hunanensis is revealed. In one example, vitrification and peeling show the annuli hidden under the chor... In the light of Synchrotron Radiation X-ray Tomographic Microscopy (SRXTM), the internal structure of Markuelia hunanensis is revealed. In one example, vitrification and peeling show the annuli hidden under the chorion. Sectioning and 3-D reconstruction display an intact digestive tract from the inverted introvert to the terminal anus. The inverted introvert forms a rugby cavum. The following digestive tract is rope-like coiling, parallel to the body axis, about 650 μm in length, and uniform in diameter (-80 μm). An exquisitely preserved pipe-like structure is hidden in the middle of the rope-like structure, diameter 20--40 lam, with a length of -120 μm. We interpret this pipe-like structure as the possible epidermis of the gut and its surroundings as the possible residue of musculature, similar to that in Priapulans. The two symmetrical rod-shape structures connecting the body wall and digestive tract are interpreted as the possible retractor muscles. After comparing the well preserved Left-form and Right-form Body of Markuelia, we suggest that they may represent a dimorphism. Counted directly, one sample of Markuelia hunanensis possesses 62 annulations and the other 68. 展开更多
关键词 Markuelia Synchrotron Radiation X-ray tomographic Microscopy (SRXTM) dimorphism
下载PDF
Static CSI Extraction and Application in the Tomographic Channel Model 被引量:2
17
作者 Haihan Li Yunzhou Li +1 位作者 Shidong Zhou Jing Wang 《China Communications》 SCIE CSCD 2019年第12期132-144,共13页
In this paper, the statistical properties of parameters of each path in wireless channel models are analyzed to prove that there is the static part in channel state information(CSI) which can be extracted from huge am... In this paper, the statistical properties of parameters of each path in wireless channel models are analyzed to prove that there is the static part in channel state information(CSI) which can be extracted from huge amounts of CSI data. Based on the analysis, the concept of the Tomographic Channel Model(TCM) is presented. With cluster algorithms, the static CSI database can be built in an off-line manner. The static CSI database can provide prior information to help pilot design to reduce overhead and improve accuracy in channel estimation. A new CSI prediction method and a new channel estimation method between different frequency bands are introduced based on the static CSI database. Using measurement data, the performance of the new channel prediction method is compared with that of the Auto Regression(AR) predictor. The results indicate that the prediction range of the new method is better than that of the AR method and the new method can predict with fewer pilot symbols. Using measurement data, the new channel estimation method between different frequency bands can estimate the CSI of one frequency band based on known CSI of another frequency band without any feedback. 展开更多
关键词 big data tomographic channel model channel prediction channel estimation channel feedback K-means clustering
下载PDF
Tomographic PIV investigation on coherent vortex structures over shark-skin-inspired drag-reducing riblets 被引量:8
18
作者 Shao-Qiong Yang Shan Li +2 位作者 Hai-Ping Tian Qing-Yi Wang Nan Jiang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2016年第2期284-294,共11页
Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-insp... Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-inspired riblets on coherent vortex structures in a turbulent boundary layer(TBL) is investigated.This is done by means of tomographic particle image velocimetry(TPIV) measurements in channel fl ws over an acrylic plate of drag-reducing riblets at a friction Reynolds number of 190.The turbulent fl ws over drag-reducing riblets are verifie by a planar time-resolved particle image velocimetry(TRPIV) system initially,and then the TPIV measurements are performed.Two-dimensional(2D) experimental results with a dragreduction rate of around 4.81% are clearly visible over triangle riblets with a peak-to-peak spacing s+of 14,indicating from the drag-reducing performance that the buffer layer within the TBL has thickened;the logarithmic law region has shifted upward and the Reynolds shear stress decreased.A comparison of the spatial topological distributions of the spanwise vorticity of coherent vortex structures extracted at different wall-normal heights through the improved quadrant splitting method shows that riblets weaken the amplitudesof the spanwise vorticity when ejection(Q2) and sweep(Q4) events occur at the near wall,having the greatest effect on Q4 events in particular.The so-called quadrupole statistical model for coherent structures in the whole TBL is verified Meanwhile,their spatial conditional-averaged topological shapes and the spatial scales of quadrupole coherent vortex structures as a whole in the overlying turbulent fl w over riblets are changed,suggesting that the riblets dampen the momentum and energy exchange between the regions of near-wall and outer portion of the TBL by depressing the bursting events(Q2 and Q4),thereby reducing the skin friction drag. 展开更多
关键词 Turbulent boundary layer(TBL) Coherent vortex structure Flow control Drag reduction Shark-skininspired riblet tomographic particle image velocimetry(TPIV)
下载PDF
Myocardial bridging analysis by coronary computed tomographic angiography in a Saudi population 被引量:1
19
作者 Ragab Hani Donkol Zizi Saad 《World Journal of Cardiology》 CAS 2013年第11期434-441,共8页
AIM: To assess the incidence, location, morphology and clinical association of myocardial bridging in a Saudi population using coronary computed tomographic angiography(CCTA). METHODS: A total of 350 CCTA of Saudi pat... AIM: To assess the incidence, location, morphology and clinical association of myocardial bridging in a Saudi population using coronary computed tomographic angiography(CCTA). METHODS: A total of 350 CCTA of Saudi patients were included in this study(236 men, 114 women) with a mean age of 56.3 years. All patients were examined for appropriateness criteria of CCTA indications(typical chest pain, recent onset cardiomyopathy, left bundle branch block, etc.). The scans were retrospectively reviewed for the presence of myocardial bridging and any other pathological association. RESULTS: Myocardial bridging was found in 89 of 350(22.5%) patients. Most of the intramuscular segments were of the superficial type and found in the mid left anterior descending(LAD)(24.6%), followed by distal LAD(3.7%), diagonal branches(2%), ramus intermedius artery(1.4%) and obtuse marginal artery(0.8%). No myocardial bridging was detected in the right coronary or circumflex arteries. No significant differences were found between males and females(P = 0.14). Coronary artery atherosclerosis was found in 51 of 89(57.3%) patients with MB. Atherosclerotic plaques were not detected in the intramuscular or distal segment of bridging arteries. Dynamic compression was observed in 35(94.5%) patients with full encasement. No evidence of myocardial hypoperfusion was found in the territories supplied by the bridging arteries. CONCLUSION: CCTA is excellent in analyzing myocardial bridging in a Saudi population and the results are comparable to other populations. However, finding the real incidence may need a large multicenter study. 展开更多
关键词 CORONARY heart disease MYOCARDIAL bridging CORONARY COMPUTED tomographic ANGIOGRAPHY CORONARY ARTERIES anatomy CORONARY atherosclerosis
下载PDF
Narrow-band tomographic radar imaging of precession cone targets 被引量:1
20
作者 Xizhang Wei Shixian Gong Xiaofeng Ding 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2012年第6期866-874,共9页
The principle and method of the narrow-band tomo-graphic radar imaging (NBTRI) of the precession cone target are studied. Firstly, the motion model and electromagnetic scattering characteristics of the precession co... The principle and method of the narrow-band tomo-graphic radar imaging (NBTRI) of the precession cone target are studied. Firstly, the motion model and electromagnetic scattering characteristics of the precession cone target are introduced. Secondly, based on the traditional NBTRI algorithm, a novel narrow-band tomography clean radar imaging (NBTCRI) algorithm is proposed to enhance the image quality of NBTRI results. In addition, the resolution performance of the NBTRI algorithm is analyzed. Finally, based on the ideal scattering point model, this paper discusses the relationship between the precession angle and the estimated target size from NBTRI results. By using the target's chamber data, NBTRI and NBTCRI results of the precession cone target are further analyzed, which indicates the effectiveness of the proposed method. 展开更多
关键词 NARROW-BAND tomographic PRECESSION tomographyclean.
下载PDF
上一页 1 2 7 下一页 到第