期刊文献+
共找到73,634篇文章
< 1 2 250 >
每页显示 20 50 100
Multidetector computer tomography and magnetic resonance imaging of double superior mesenteric veins:A case report
1
作者 Wei Tang Song Peng 《World Journal of Clinical Cases》 SCIE 2024年第17期3265-3270,共6页
BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMA... BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMARY We describe the case of a 34-year-old male,who underwent both MDC and MRI examinations of the upper abdomen because of liver cirrhosis.MDCT and MRI angiography images of the upper abdomen revealed an anatomic variation of the superior mesenteric vein(SMV),the double SMVs.CONCLUSION The double SMVs are a congenital abnormality without potential clinical manifestation.Physicians need to be aware of this anatomical variation during abdominal surgery to avoid iatrogenic injury. 展开更多
关键词 Superior mesenteric vein Anatomic variation Magnetic resonance imaging Multidetector computer tomography Case report
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report 被引量:2
2
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst Computer tomography MISDIAGNOSIS HEMORRHAGE INFECTION Case report
下载PDF
Study on sex differences and potential clinical value of threedimensional computerized tomography pelvimetry in rectal cancer patients
3
作者 Xiao-Cong Zhou Fei-Yue Ke +2 位作者 Gaurav Dhamija Hao Chen Qiang Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期773-786,共14页
BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampe... BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampers the establishment of consistent conclusions.AIM To comprehensively assess 16 pelvic and 7 soft tissue parameters through computerized tomography(CT)-based three-dimensional(3D)reconstruction,providing a strong theoretical basis to address challenges in laparoscopic rectal cancer radical surgery.METHODS We analyzed data from 218 patients who underwent radical laparoscopic surgery for rectal cancer,and utilized CT data for 3D pelvic reconstruction.Specific anatomical points were carefully marked and measured using advanced 3D modeling software.To analyze the pelvic and soft tissue parameters,we emp-loyed statistical methods including paired sample t-tests,Wilcoxon rank-sum tests,and correlation analysis.RESULTS The investigation highlighted significant sex disparities in 14 pelvic bone parameters and 3 soft tissue parameters.Males demonstrated larger measurements in pelvic depth and overall curvature,smaller measurements in pelvic width,a larger mesorectal fat area,and a larger anterior-posterior abdominal diameter.By contrast,females exhibited wider pelvises,shallower depth,smaller overall curvature,and an increased amount of subcutaneous fat tissue.However,there were no significant sex differences observed in certain parameters such as sacral curvature height,superior pubococcygeal diameter,rectal area,visceral fat area,waist circumference,and transverse abdominal diameter.CONCLUSION The reconstruction of 3D CT data enabled accurate pelvic measurements,revealing significant sex differences in both pelvic and soft tissue parameters.This study design offer potential in predicting surgical difficulties and creating personalized surgical plans for male rectal cancer patients with a potentially“difficult pelvis”,ultimately improving surgical outcomes.Further research and utilization of these parameters could lead to enhanced surgical methods and patient care in laparoscopic rectal cancer radical surgery. 展开更多
关键词 Computerized tomography Rectal cancer Three-dimensional reconstruction PELVIMETRY Sex differences
下载PDF
Avoiding misdiagnosis of multilocular thymic cysts as malignant tumors on computer tomography
4
作者 Yu-Hong Zhang Yan-Miao Liu +2 位作者 Kai-Li Shen Jing-Jing Wu Fu-Shan Tang 《World Journal of Clinical Cases》 SCIE 2024年第19期3671-3675,共5页
This editorial provides insights from a case report by Sun et al published in the World Journal of Clinical Cases.The case report focuses on a case where a multilocular thymic cyst(MTC)was misdiagnosed as a thymic tum... This editorial provides insights from a case report by Sun et al published in the World Journal of Clinical Cases.The case report focuses on a case where a multilocular thymic cyst(MTC)was misdiagnosed as a thymic tumor,resulting in an unnecessary surgical procedure.Both MTCs and thymic tumors are rare conditions that heavily rely on radiological imaging for accurate diagnosis.However,the similarity in their imaging presentations can lead to misinterpretation,resulting in unnecessary surgical procedures.Due to the ongoing lack of comprehensive knowledge about MTCs and thymic tumors,we offer a summary of diagnostic techniques documented in recent literature and examine potential causes of misdiagnosis.When computer tomography(CT)values surpass 20 Hounsfield units and display comparable morphology,there is a risk of misdiagnosing MTCs as thymic tumors.Employing various differential diagnostic methods like biopsy,molecular biology,multi-slice CT,CT functional imaging,positron emission tomography/CT molecular functional imaging,magnetic resonance imaging and radiomics,proves advantageous in reducing clinical misdiagnosis.A deeper understanding of these conditions requires increased attention and exploration by healthcare providers.Moreover,the continued advancement and utilization of various diagnostic methods are expected to enhance precise diagnoses,provide appropriate treatment options,and improve the quality of life for patients with thymic tumors and MTCs in the future.continued advancement and utilization of various diagnostic methods are expected to enhance precise diagnoses,provide appropriate treatment options,and improve the quality of life for patients with thymic tumors and MTCs in the future. 展开更多
关键词 Thymic tumor Multilocular thymic cyst MISDIAGNOSIS Differential diagnosis Imaging manifestation Computed tomography
下载PDF
Detection of tracheal branching with computerized tomography:The relationship between the angles and age-gender
5
作者 Şevket Kahraman Mesut Furkan Yazar +2 位作者 Hüseyin Aydemir Mecit Kantarci Sonay Aydin 《World Journal of Radiology》 2023年第4期118-126,共9页
BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physi... BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physiology.AIM To determine the tracheobronchial branching angles in pediatric and adult populations by using the multislice computed tomography(CT)and minimum intensity projection(MinIP)technique,which is a non-invasive method.METHODS Our study was carried out retrospectively.Patients who underwent contrast and non-contrast CT examination,whose anatomically and pathophysiologically good tracheobronchial system and lung parenchyma images were obtained,were included in the study.Measurements were made in the coronal plane of the lung parenchyma.In the coronal plane,right main bronchus-left main bronchus angle,right upper lobe bronchus-intermedius bronchus angle,right middle lobe bronchus-right lower lobe bronchus angle,left upper lobe bronchus-left lower lobe bronchus angle were measured.RESULTS The study population consisted of 1511 patients,753 pediatric(mean age:13.4±4.3;range:1-18 years)and 758 adults(mean age:54.3±17.3;range:19-94 years).In our study,tracheal bifurcation angle was found to be 73.3°±13.7°(59.6°-87°)in the whole population.In the pediatric group,the right-left main coronal level was found to be higher in boys compared to girls(74.6°±12.9°vs 71.2°±13.9°,P=0.001).In the adult group,the right-left main coronal level was found to be lower in males compared to females(71.9°±12.9°vs 75.8°±14.7°,P<0.001).CONCLUSIONS Our study,with the number of 1511 patients,is the first study in the literature with the largest number of patient populations including pediatric and adult demographic data,measuring the angle values of the tracheobronchial system using multislice CT and MinIP technique.Study data will not only be a guide during invasive procedures,but it can also guide studies to be done with imaging methods. 展开更多
关键词 Tracheobronchial branching angles Subcarinal angle Multislice computerized tomography Minimum intensity projection technique
下载PDF
Reduction of the Beam Hardening Artifacts in the X-Ray Computer Tomography: Energy Discrimination with a Photon-Counting Detector
6
作者 Yukino Imura Takuto Yanagida +2 位作者 Hisashi Morii Hidenori Mimura Toru Aoki 《World Journal of Nuclear Science and Technology》 2012年第4期169-173,共5页
The material identification is a pressing requirement for the sensitive security applications. Dual-energy X-ray computer tomography (DXCT) has been investigated for material identification in the medical and security... The material identification is a pressing requirement for the sensitive security applications. Dual-energy X-ray computer tomography (DXCT) has been investigated for material identification in the medical and security fields. It requires two tomographic images at sufficiently different energies. To discriminate dangerous materials of light elements such as plastic bombs in luggage, it is needed to measure accurately with several tens of kilo electron volts where such materials exhibit significant spectral differences. However, CT images in that energy region often include artifacts from beam hardening. To reduce these artifacts, a novel reconstruction method has been investigated. It is an extension of the Al-gebraic Reconstruction Technique and Total Variation (ART-TV) method that reduces the artifacts in a lower-energy CT image by referencing it to an image obtained at higher energy. The CT image of a titanium sample was recon-structed using this method in order to demonstrate the artifact reduction capability. 展开更多
关键词 x-ray Computer tomography ARTIFACTS PHOTON COUNTING Iterative Reconstruction ART-TV Titanium Sample Security Applications
下载PDF
X-Ray Industrial Computerized Tomography System for Testing Advanced Structural Ceramics
7
作者 张朝宗 《High Technology Letters》 EI CAS 1995年第2期86-89,共4页
This paper presents a X-ray industrial CT system with an image intensifier for NDT of ceramics, which was developed by Tsinghua University in 1990, and another one with discrete detectors, which is under constructing,... This paper presents a X-ray industrial CT system with an image intensifier for NDT of ceramics, which was developed by Tsinghua University in 1990, and another one with discrete detectors, which is under constructing, and puts forward the work plan for the near future. 展开更多
关键词 CT tomography DETECTOR RECONSTRUCTION CERAMICS RADIOGRAPHY
下载PDF
Pore structure of ore granular media by computerized tomography image processing 被引量:6
8
作者 吴爱祥 杨保华 +1 位作者 习泳 江怀春 《Journal of Central South University of Technology》 EI 2007年第2期220-224,共5页
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ... The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%. 展开更多
关键词 ore granular media pore structure x-ray computerized tomography image processing
下载PDF
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
9
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
下载PDF
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
10
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor x-ray computed tomography(CT)
下载PDF
Experimental Study on Effect of Compound Biejia Ruangan Prescription (复方鳖甲软肝方) on High Resolution Computerized Tomographic Images in Bleomycin Induced Pulmonary Fibrosis Rats 被引量:2
11
作者 张东伟 王继峰 +2 位作者 牛建昭 高宝华 李贡宇 《Chinese Journal of Integrated Traditional and Western Medicine》 2003年第4期270-275,共6页
Objective: To study the therapeutic effect of Com pound Biejia Ruangan prescription (CBRP) on rat model with pulmonary fibrosis in duced by bleomycin. Methods: Fifty four male Sprague Dawley rats were rando mly divide... Objective: To study the therapeutic effect of Com pound Biejia Ruangan prescription (CBRP) on rat model with pulmonary fibrosis in duced by bleomycin. Methods: Fifty four male Sprague Dawley rats were rando mly divided into 6 groups (9 rats in each group). From the first day to the 28th day of the experiment, except to those in the sham model control group that were treated with normal saline, the same amount of bleomycin injection as the n ormal saline given to the control group was given through endotracheal instillat ion to all the rats in all the other groups. From the 29th day of the modeling, CBRP solution of different dosages was respectively injected into the rats in th e high, moderate and low CBRP dose group, while equal volume of normal saline w as given to those in the sham model control group and the model control group , and an equal volume of prednisone solution was given to rats in the prednisone group. On the 80th day, the high resolution computerized tomographic (HRCT) images were observed on an equal footing, and HRCT pathology was correlativel y studied. Results: Different HRCT pathological changes were shown in th e rats with pulmonary fibrosis, such as lung consolidation, thickening of interl obular septum and interlobular mesenchyma as well as lobular deformation, nodule shadow, abnormal brochiovascular tract, thickened pleura with irregular junctio n and polished glass like dense shadows. Honeycomb lung was observed in some cases. Pathological sections showed fibrotic proliferation of lung tissues and noticeable pulmonary interstitial fibrosis. CBRP could improve HRCT images of rats with pulmonary fibrosis, and lower fibrotic p roliferation of the lung tissue.Conclusion: CBRP plays its therapeutic role possibly through its effect on the structure of the lung in rats with pulmonary fibrosis. 展开更多
关键词 Compound Biejia Ruangan prescription rat s pulmonary fibrosis high resolution computerizd tomography
下载PDF
Comments on the article about correlation between computerized tomography and surgery in acute pancreatitis 被引量:1
12
作者 Enver Zerem Goran Imamovi +1 位作者 Zoran Mavija Bahrija Harai 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第3期407-408,共2页
We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the natu... We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections found at surgery. The results of their study indicate that most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue and CECT has a limited role in differentiating various types of collections. However, there are some points that need to be addressed, including data about the stage of acute pancreatitis in which CECT was done and the time span between CECT examination and surgery. 展开更多
关键词 Acute pancreatitis Pancreatic necrosis Peripancreatic fluid collection Contrast-enhanced computerized tomography SURGERY
下载PDF
Screening for lung cancer with chest computerized tomography: Is it cost efficient?
13
作者 Tomasz Jaroslaw Szczesny Malgorzata Kanarkiewicz Janusz Kowalewski 《World Journal of Respirology》 2015年第2期160-165,共6页
Despite lung cancer(LC) screening by low-dose computerized tomography(LDCT) gaining many proponents worldwide, for many years it was not recognized as a life-prolonging and cost-effective procedure, until recently. Pr... Despite lung cancer(LC) screening by low-dose computerized tomography(LDCT) gaining many proponents worldwide, for many years it was not recognized as a life-prolonging and cost-effective procedure, until recently. Prospective observational studies had not been able to prove that this screening prolongs survival, but they helped to specify the inclusion and exclusion criteria. Long-awaited results of a prospective, randomized trial finally provided the evidence that LC screening with LDCT can prolong survival of the screened population. Several costeffectiveness analyses were performed to justify mass introduction of this screening. Results of these analyses are equivocal, although conclusions highly depend upon inclusion and exclusion criteria, methods of analysis and prices of medical procedures which differ between countries as well as the incidence of other pulmonary nodules, especially tuberculosis. Therefore, costeffectiveness analysis should be performed separately for every country. Cost-effectiveness depends especially upon the rate of false-positive results and the rate of unnecessary diagnostic, screening and treatment procedures. To ensure high cost-effectiveness, LC screening should be performed in accordance with screening protocol, in dedicated screening centers equipped with nodule volume change analysis, or as a prospective non-randomized trial, to ensure compliance with the inclusion and exclusion criteria. To ensure high cost-effectiveness of LC screening, future research should concentrate on determination of highrisk groups and further specifying the inclusion and exclusion criteria. 展开更多
关键词 Lung cancer Non-small cell lung cancers SCREENING COST-EFFECTIVENESS Computerized tomography Low-dose computerized tomography
下载PDF
Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping, transcranial Doppler sonography and computer tomography examinations
14
作者 Dongruo He Xiaoying Xu +1 位作者 Yinghui Zhang Guochao Han 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期379-381,共3页
BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderat... BACKGROUND: It has been proved that brain electrical activity mapping (BEAM) and transcranial Doppler (TCD) detection can reflect the function of brain cell and its diseased degree of infant patients with moderate to severe hypoxic-ischemic encephalopathy (HIE). OBJECTIVE: To observe the abnormal results of HIE at different degrees detected with BEAM and TCD in infant patients, and compare the detection results at the same time point between BEAM, TCD and computer tomography (CT) examinations. DESIGN : Contrast observation SETTING: Departments of Neuro-electrophysiology and Pediatrics, Second Affiliated Hospital of Qiqihar Medical College. PARTICIPANTS: Totally 416 infant patients with HIE who received treatment in the Department of Newborn Infants, Second Affiliated Hospital of Qiqihar Medical College during January 2001 and December 2005. The infant patients, 278 male and 138 female, were at embryonic 37 to 42 weeks and weighing 2.0 to 4.1 kg, and they were diagnosed with CT and met the diagnostic criteria of HIE of newborn infants compiled by Department of Neonatology, Pediatric Academy, Chinese Medical Association. According to diagnostic criteria, 130 patients were mild abnormal, 196 moderate abnormal and 90 severe abnormal. The relatives of all the infant patients were informed of the experiment. METHOOS: BEAM and TCD examinations were performed in the involved 416 infant patients with HIE at different degrees with DYD2000 16-channel BEAM instrument and EME-2000 ultrasonograph before preliminary diagnosis treatment (within 1 month after birth) and 1,3,6,12 and 24 months after birth, and detected results were compared between BEAM, TCD and CT examinations. MAIN OUTCOME MEASURES: Comparison of detection results of HIE at different time points in infant patients between BEAM. TCD and CT examinations. RESULTS: All the 416 infant patients with HIE participated in the result analysis. (1) Comparison of the detected results in infant patients with mild HIE at different time points after birth between BEAM, TCD and CT examinations: BEAM examination showed that the recovery was delayed, and the abnormal rate of BEAM examination was significantly higher than that of CT examination 1 and 3 months after birth [55.4%(72/130)vs. 17.0% (22/130 ),x^2=41.66 ;29.2% ( 38/130 ) vs. 6.2% ( 8/130 ), x^2=23.77, P 〈 0.01 ], exceptional patients had mild abnormality and reached the normal level in about 6 months. TCD examination showed that the disease condition significantly improved and infant patients with HIE basically recovered 1 or 2 months after birth, while CT examination showed that infant patients recovered 3 or 4 months after birth. (2) Comparison of detection results of infant patients with moderate HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination 1,3,6 and 12 months after birth [90.8% (178/196),78.6% (154/196),x^2=4.32,P 〈 0.05;64.3% (126/196),43.9% (86/196) ,x^2=16.44 ;44.9% (88/196) ,22.4% (44/196),x^2=22.11 ;21.4% (42/196), 10.2% (20/196),x^2=9.27, P 〈 0.01]. BEAM examination showed that there was still one patient who did not completely recovered in the 24^th month due to the relatives of infant patients did not combine the treatment,. TCD examination showed that the abnormal rate was 23.1%(30/196)in the 1^st month after birth, and all the patients recovered to the normal in the 3^rd month after birth, while CT examination showed that mild abnormality still existed in the 24^th month after birth (1.0% ,2/196). (3) Comparison of detection results of infant patients with severe HIE at different time points between BEAM, TCD and CT examinations: The abnormal rate of BEAM examination was significantly higher than that of CT examination in the 1^st, 3^rd, 6^th and 12^th months after birth[86.7% (78/90),44.4% (40/90),x^2=35.53;62.2% (56/90),31.1% (28/90),x^2=17.51 ;37.8% (34/90),6.7% (6/90), x^2=27.14, P 〈 0.01]. BEAM examination showed that mild abnormality still existed in 4 infant patients in the 24^th month after birth. TCD examination showed that the abnormal rate was 11.1% (10/90) in the 3^rd month after birth, and all the infant patients recovered in the 6^th month after birth. CT examination showed that the abnormal rate was 6.7%(6/90) in the 12^th month after birth, and all of infant patients recovered to the normal in the 24^th month after birth.CONCLUSION : BEAM is the direct index to detect brain function of infant patients with HIE, and positive reaction is still very sensitive in the tracking detection of convalescent period. The positive rate of morphological reaction in CT examination is superior to that in TCD examination, and the positive rate is very high in the acute period of HIE in examination. 展开更多
关键词 HIE Comparison of detection results of hypoxic-ischemic encephalopathy at different degrees in infant patients between brain electrical activity mapping transcranial Doppler sonography and computer tomography examinations
下载PDF
Clinical significance of mesenteric panniculitis-like abnormalities on abdominal computerized tomography in patients with malignant neoplasms 被引量:8
15
作者 Eli D Ehrenpreis Grigory Roginsky Richard M Gore 《World Journal of Gastroenterology》 SCIE CAS 2016年第48期10601-10608,共8页
AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric pan... AIM To clarify the association of malignancy with mesenteric panniculitis-like changes on computed tomography(CT).METHODS All abdominal CT scans performed at North Shore University HealthS ystem showing mesenteric panniculitis from January 2005 to August 2010 were identified in the Radnet(Rad Net Corporation, Los Angeles, CA) database. Patients with a new or known diagnosis of a malignancy were included for this analysis. Longitudinal clinical histories were obtained from electronic medical records.RESULTS In total, 147794 abdominal CT scans were performed during the study period. Three hundred and fiftynine patients had mesenteric panniculitis(MP)-like abnormalities on their abdominal CT. Of these patients, 81 patients(22.6%) had a known history of cancer at the time of their CT scan. Nineteen(5.3%) had a new diagnosis of cancer in concurrence with their CT, but the majority of these(14/19, 74%) were undergoing CT as part of a malignancy evaluation. Lymphomas were the most common cancers associated with MPlike findings on CT(36 cases, 36%), with follicular lymphoma being the most frequent subtype(17/36). A variety of solid tumors, most commonly prostate(7) and renal cell cancers(6) also were seen. CT follow up was obtained in 56 patients. Findings in the mesentery were unchanged in 45(80%), worsened in 6(11%), and improved in 5 patients(9%). Positron emission tomography(PET) scans performed in 44 patients only showed a positive uptake in the mesenteric mass in 2 patients(5%). CONCLUSION A new diagnosis of cancer is uncommon in patients with CT findings suggestive of MP. MP-like mesenteric abnormalities on CT generally remain stable in patients with associated malignancies. PET scanning is not recommended in the evaluation of patients with mesenteric panniculitis-like findings on CT. 展开更多
关键词 PANNICULITIS PERITONEAL X ray Neoplasms Computed tomography Small INTESTINE Misty MESENTERY Lymphoma tomography Positron emission tomography
下载PDF
Laparoscopic vs computerized tomography-guided radiofrequency ablation for large hepatic hemangiomas abutting the diaphragm 被引量:16
16
作者 Jun Gao Jian Kong +9 位作者 Xue-Mei Ding Shan Ke Hai-Gang Niu Zong-Hai Xin Chun-Min Ning Shi-Gang Guo Xiao-Long Li Long Zhang Yong-Hong Dong Wen-Bing Sun 《World Journal of Gastroenterology》 SCIE CAS 2015年第19期5941-5949,共9页
AIM: To compare safety and therapeutic efficacy of laparoscopic radiofrequency(RF) ablation vs computed tomography(CT)-guided RF ablation for large hepatic hemangiomas abutting the diaphragm.METHODS: We retrospectivel... AIM: To compare safety and therapeutic efficacy of laparoscopic radiofrequency(RF) ablation vs computed tomography(CT)-guided RF ablation for large hepatic hemangiomas abutting the diaphragm.METHODS: We retrospectively reviewed our sequential experience of treating 51 large hepatic hemangiomas abutting the diaphragm in 51 patients by CT-guided or laparoscopic RF ablation due to either the presence of symptoms and/or the enlargement of hemangioma.Altogether, 24 hemangiomas were ablated via a CTguided percutaneous approach(CT-guided ablation group), and 27 hemangiomas were treated via a laparoscopic approach(laparoscopic ablation group).RESULTS: The mean diameter of the 51 hemangiomas was 9.6 ± 1.8 cm(range, 6.0-12.0 cm). There was nodifference in the diameter of hemangiomas between the two groups(P > 0.05). RF ablation was performed successfully in all patients. There was no difference in ablation times between groups(P > 0.05). There were 23 thoracic complications in 17 patients: 15(62.5%, 15/24) in the CT-guided ablation group and2(7.4%, 2/27) in the laparoscopic ablation group(P< 0.05). According to the Dindo-Clavien classification,two complications(pleural effusion and diaphragmatic rupture grade Ⅲ) were major in two patients. All others were minor(grade Ⅰ). Both major complications occurred in the CT-guided ablation group. The minor complications were treated successfully with conservative measures, and the two major complications underwent treatment by chest tube drainage and thoracoscopic surgery, respectively. Complete ablation was achieved in 91.7%(22/24) and 96.3%(26/27) in the CT-guided and the laparoscopic ablation groups,respectively(P > 0.05).CONCLUSION: Laparoscopic RF ablation therapy should be used as the first-line treatment option for large hepatic hemangiomas abutting the diaphragm.It avoids thermal injury to the diaphragm and reduces thoracic complications. 展开更多
关键词 Hepatic HEMANGIOMA RADIOFREQUENCY ablation DIAPHRAGM COMPUTED tomography LAPAROSCOPY
下载PDF
Application of high resolution computer tomography in external ear canal cholesteatoma diagnosis 被引量:2
17
作者 Yubin Chen Peng Li 《Journal of Otology》 CSCD 2018年第1期25-28,共4页
Objective: To evaluate High Resolution Computer Tomography(HRCT) in the diagnosis of external ear canal cholesteatoma.Methods: In this retrospective study, HRCTs of 27 patients with external ear canal cholesteatoma we... Objective: To evaluate High Resolution Computer Tomography(HRCT) in the diagnosis of external ear canal cholesteatoma.Methods: In this retrospective study, HRCTs of 27 patients with external ear canal cholesteatoma were reviewed. The changes in the external ear canal, tympanic membrane(TM), scutum, tympanum and mastoid were measured and categorized.Results: Fourteen patients showed no or mild destruction in the external ear canal(stage Ⅰ group). Eight patients had obvious enlargement in the external ear canal(stage Ⅱ group) but showed limited destructions of the mastoid bone and no damage of the tympanums. Five patients had serious destruction of the mastoid bone and damage of the tympanum(stage Ⅲ group). All patients in the stage Ⅲ group showed a compression of manubriums and TMs, with 3 having damages on ossicular chain. Bone destruction of the vertical section of facial nerve canal was discovered in one case in the stage Ⅲ group.Conclusion: HRCT can provide detail information about the extent of external ear canal cholesteatoma. Such information can be used to identify special situations with serious complications and to differentiate external ear canal cholesteatoma from middle ear cholesteatoma. 展开更多
关键词 EXTERNAL EAR CANAL CHOLESTEATOMA COMPUTER tomography
下载PDF
Optic nerve sheath diameters in healthy adults measured by computer tomography 被引量:3
18
作者 Michael Vaiman Rani Abuita Inessa Bekerman 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第6期1240-1244,共5页
AIMTo measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring.METHODSIn a pros... AIMTo measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring.METHODSIn a prospective cohort study, CT data of 300 healthy adults were analyzed (600 eyes). In all cases, the CT investigation was performed at the Emergency Department because of the various conditions that proved not to be connected with ophthalmological or neurological pathology. The ONSD were measured at 3 mm and 8 mm distance from the globe, and 3 mm from the anterior opening of the optic canal. The correlation analysis was performed with gender, age, and ethnic background.RESULTSThe right/left ONSD are 4.94&#x000b1;1.51/5.17&#x000b1;1.34 mm at 3 mm, 4.35&#x000b1;0.76/4.45&#x000b1;0.62 mm at 8 mm from the globe, and 3.55&#x000b1;0.82/3.65&#x000b1;0.7 mm at 3 mm from the optic canal. No significant differences correlated with gender of the patients, their age, and ethnic background were found.CONCLUSIONIn healthy persons, the ONSD varies from 5.17&#x000b1;1.34 mm to 3.55&#x000b1;0.82 mm in different locations within the intraorbital space. The most stable results with lesser standard deviation can be obtained if it is measured 8-10 mm from the globe. 展开更多
关键词 optic nerve sheath computer tomography intracranial pressure
下载PDF
Application of Proton Magnetic Resonance Spectroscopy and Computerized Tomography in the Diagnosis and Treatment of Nonalcoholic Fatty Liver Disease 被引量:4
19
作者 王南 董慧 +1 位作者 魏世超 陆付耳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期295-298,共4页
In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluati... In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluation of therapeutic effects, 22 patients with NAFLD were selected according to the Chinese Medical Association's (CMA) standard of the NAFLD in comparison with 20 healthy volunteers (as control group). Blood samples for biochemistry were collected. The severity of hepatosteatosis was evaluated by ^1H-MRS scan and CT scan of liver. The intrahepatic content of lipid (IHCL) and CT value ratio of liver to spleen were calculated. The patients in NAFLD group were treated with Ganzhixiao Capsule for 8 weeks. The changes in IHCL and CT value ratio of liver to spleen were observed before and after treatment. In NAFLD group serum ALT, TG, IHCL calculated by ^1HMRS were increased and CT value ratio of liver to spleen decreased significantly as compared with control group. After treatment for 8 weeks serum ALT, TG, IHCL were decreased significantly, while CT value ratio of liver to spleen increased significantly in NAFLD group. It was suggested that IHCL could be measured precisely by ^1HMRS. NAFLD was treated effectively by Ganzhixiao capsule. 展开更多
关键词 proton magnetic resonance spectroscopy computerized tomography nonalcoholic fatty liver disease
下载PDF
Effects of Irregular Respiratory Motion on the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography 被引量:1
20
作者 Xiang Li Tianfang Li +9 位作者 Ellen Yorke Gig Mageras Xiaoli Tang Maria Chan Weijun Xiong Marsha Reyngold Richard Gewanter Abraham Wu John Cuaron Margie Hunt 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第2期173-183,共11页
For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT ... For positioning a moving target, a maximum intensity projection (MIP) or average intensity projection (AIP) image derived from 4DCT is often used as the reference image which is matched to free breathing cone-beam CT (FBCBCT) before treatment. This method can be highly accurate if the respiratory motion of the patient is stable. However, a patient’s breathing pattern is often irregular. The purpose of this study is to investigate the effects of irregular respiration on positioning accuracy for a moving target aligned with FBCBCT. Nine patients’ respiratory motion curves were selected to drive a Quasar motion phantom with one embedded cubic and two spherical targets. A 4DCT of the phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. FBCBCTs of the phantom driven by the same respiratory curves were also acquired on a Varian TrueBeam and fused such that both CBCT and MIP/AIP images share the same target zero positions. The sphere and cube volumes and centroid differences (alignment error) determined by MIP, AIP and FBCBCT images were calculated, respectively. Compared to the volume determined by MIP, the volumes of the cube, large sphere, and small sphere in AIP and FBCBCT images were smaller. The alignment errors for the cube, large sphere and small sphere with center to center matches between MIP and FBCBCT were 2.5 ± 1.8 mm, 2.4 ± 2.1 mm, and 3.8 ± 2.8 mm, and the alignment errors between AIP and FBCBCT were 0.5 ± 1.1 mm, 0.3 ± 0.8 mm, and 1.8 ± 2.0 mm, respectively. AIP images appear to be superior reference images to MIP images. However, irregular respiratory pattern could compromise the positioning accuracy, especially for smaller targets. 展开更多
关键词 CONE Beam COMPUTERIZED tomography RESPIRATORY Motion Effect
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部