期刊文献+
共找到72,687篇文章
< 1 2 250 >
每页显示 20 50 100
Tracking the phase transformation and microstructural evolution of Sn anode using operando synchrotron X-ray energy-dispersive diffraction and X-ray tomography 被引量:1
1
作者 Kang Dong Fu Sun +4 位作者 Andre Hilger Paul H.Kamm Markus Osenberg Francisco Garcia-Moreno Ingo Manke 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第1期429-437,I0011,共10页
Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evol... Tin(Sn)holds great promise as an anode material for next-generation lithium(Li)ion batteries but suffers from massive volume change and poor cycling performance.To clarify the dynamic chemical and microstructural evolution of Sn anode during lithiation and delithiation,synchrotron X-ray energydispersive diffraction and X-ray tomography are simultaneously employed during Li/Sn cell operation.The intermediate Li-Sn alloy phases during de/lithiation are identified,and their dynamic phase transformation is unraveled which is further correlated with the volume variation of the Sn at particle-and electrode-level.Moreover,we find that the Sn particle expansion/shrinkage induced particle displacement is anisotropic:the displacement perpendicular to the electrode surface(z-axis)is more pronounced compared to the directions(x-and y-axis)along the electrode surface.This anisotropic particle displacement leads to an anisotropic volume variation at the electrode level and eventually generates a net electrode expansion towards the separator after cycling,which could be one of the root causes of mechanical detachment and delamination of electrodes during long-term operation.The unraveled chemical evolution of Li-Sn and deep insights into the microstructural evolution of Sn anode provided here could guide future design and engineering of Sn and other alloy anodes for high energy density Li-and Na-ion batteries. 展开更多
关键词 Sn anode Li-Sn phase transformation x-ray tomography Operando x-ray diffraction Anisotropic displacement Digital volume correlation(DVC)
下载PDF
Importance of computed tomography in posterior malleolar fractures:Added information to preoperative X-ray studies
2
作者 NoéDe Marchi Neto Pietro Felice Tomazini Nesello +3 位作者 Jordanna Maria Bergamasco Marco Tulio Costa Ralph Walter Christian Nilson Roberto Severino 《World Journal of Orthopedics》 2023年第12期868-877,共10页
BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was g... BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was greater than 25%of the joint.Currently,computed tomography(CT)has been gaining traction in the preoperative evaluation of ankle fractures.AIM To elucidate the similarity in dimensions and to correlate PM size in X-ray images with the articular surface of the affected tibial plafond in the axial view on CT(AXCT)of a PM fracture.METHODS Eighty-one patients(mean age:39.4±13.5 years)were evaluated(54.3%were male).Two independent examiners measured PM size in profile X-ray images(PMXR)and sagittal CT(SAGCT)slices.The correlation of the measurements between the examiners and the difference in the PM fragment sizes between the two images were compared.Next,the PM size in PMXR was compared with the surface of the tibial plafond involved in the fracture in AXCT according to the Haraguchi classification.RESULTS The correlation rates between the examiners were 0.93 and 0.94 for PMXR and SAGCT,respectively(P<0.001).Fragments were 2.12%larger in SAGCT than in PMXR(P=0.018).In PMXR,there were 56 cases<25%and 25 cases≥25%.When PMXR was<25%,AXCT corresponded to 10.13%of the tibial plafond.When PMXR was≥25%,AXCT was 24.52%(P<0.001).According to the Haraguchi classification,fracture types I and II had similar PMXR measurements that were greater than those of type III.When analyzing AXCT,a significant difference was found between the three types,with II>I>III(P<0.001).CONCLUSION PM fractures show different sizes using X-ray or CT images.CT showed a larger PM in the sagittal plane and allowed the visualization of the real dimensions of the tibial plafond surface. 展开更多
关键词 Ankle fracture Posterior malleolar fracture Computed tomography x-ray Posterior malleolus fracture Trimalleolar facture
下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
3
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution x-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios 被引量:1
4
作者 张晓丹 夏成杰 +1 位作者 肖相辉 王宇杰 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第4期373-376,共4页
We present a fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can... We present a fast synchrotron X-ray tomography study of the packing structures of rods with different aspect ratios. Utilizing the high flux of the X-rays generated from the third-generation synchrotron source, we can complete a high- resolution tomography scan within a short period of time, after which the three-dimensional (3D) packing structure can be obtained for the subsequent structural analysis. The image phase-retrieval procedure has been implemented to enhance the image contrast. We systematically investigated the effects of particle shape and aspect ratio on the structural properties including packing density and contact number. It turns out that large aspect ratio rod packings will have wider distributions of free volume fraction and larger mean contact numbers. 展开更多
关键词 synchrotron x-ray imaging tomography rod packing structure
下载PDF
Study of sawtooth oscillations on the HT-7 tokamak using 2D tomography of soft x-ray signal 被引量:1
5
作者 马天鹏 胡立群 +8 位作者 万宝年 阮怀林 高翔 甄香君 周立武 孙有文 陈忠勇 林士耀 孔伟 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第10期2061-2067,共7页
It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmo... It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmonic reconstruction method, and using the singular value decomposition to analyse the data from soft x-ray cameras. By these two arrays, 2D image reconstruction of soft x-ray emissivity can be obtained without assumption of plasma rigid rotation. Tomographic reconstruction of the m=1 mode structure is obtained during the precursor oscillation of the sawtooth crash. The crescent-shaped mode structure appearing on the contour map of the soft x-ray emissivity is consistent with the quasiinterchange mode. The characteristics of the m=1/n=1 mode structure observed in the soft x-ray tomography are as follows: the magnetic surface is made up of the crescent-shaped “hot core” and the circular “cold bubble”. The structure of the magnetic surface rotates in the direction of the electron diamagnetic drift and the rotation frequency is the oscillation frequency of soft x-ray signals. 展开更多
关键词 soft x-ray tomography sawtooth oscillation singular value decomposition (SVD)
下载PDF
Performance evaluation of the simpli¯ed spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging 被引量:1
6
作者 Haibo Zhang Guohua Geng +6 位作者 Yanrong Chen Fengjun Zhao Yuqing Hou Huangjian Yi Shunli Zhang Jingjing Yu Xiaowei He 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第3期97-106,共10页
As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)dis... As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)distribution of the probes from surface measurements.A proper photon-transportation model is critical to accuracy of XLCT.Here,we presented a systematic comparison between the common-used Monte Carlo model and simplified spherical harmonics(SPN).The performance of the two methods was evaluated over several main spec-trums using a known XLCT material.We designed both a global measurement based on the cosine similarity and a locally-averaged relative error,to quantitatively assess these methods.The results show that the SP_(3) could reach a good balance between the modeling accuracy and computational efficiency for all of the tested emission spectrums.Besides,the SP_(1)(which is equivalent to the difusion equation(DE))can be a reasonable alternative model for emission wavelength over 692nm.In vivo experiment further demonstrates the reconstruction perfor-mance of the SP:and DE.This study would provide a valuable guidance for modeling the photon-transportation in CB-XLCT. 展开更多
关键词 Cone-beam x-ray luminescence computed tomography photon-transportation model .simplified spherical harmonics approximation diffusion equations.
下载PDF
Three-dimensional morphology of the Sinocyclocheilus hyalinus(Cypriniformes: Cyprinidae) horn based on synchrotron X-ray microtomography 被引量:2
7
作者 You HE Xiao-Yong CHEN +1 位作者 Ti-Qao XIAO Jun-Xing YANG 《Zoological Research》 CAS CSCD 北大核心 2013年第5期I0020-I0026,共7页
Sinocyclocheilus is a cave-dwelling cyprinid genus endemic to southwest China. Several species possess a conspicuous horn on their head, which has been suggested as a constructive troglomorphic trait but lacks substan... Sinocyclocheilus is a cave-dwelling cyprinid genus endemic to southwest China. Several species possess a conspicuous horn on their head, which has been suggested as a constructive troglomorphic trait but lacks substantial evidence. We used non- invasive, high spatial resolution synchrotron X-ray microtomography to investigate the three-dimensional (3D) morphology of the horn of Sinocyclocheilus hyalinus, one of eight such troglobiotic species. 3D renderings demonstrated the osteological components, which were comprised of a rear wall comprised of the supraoccipital bone, a remaining frontal wall with numerous fenestrae, and the bottom continuous with the parietal and epiotic. A horn cavity occurred within the horn. The fenestrae in the frontal wall were continuous in the horn cavity and showed elaborate channeling, and were, connected to the cranial cavity by soft tissue. We tentatively called this configuration the "otocornual connection" due to its anatomic and putative functional similarity to the otolateralic connection in clupeids and loricariids, which provide an indirect pathway to enhance perception of underwater sound signals. This study provides a functional morphology context for further histological and physiological investigations of such horn structures in Sinocyclocheilus cavefish, and we suggest that the horn might enhance acoustic perception to compensate for visual loss in subterranean life, which warrants future physiological examination as lab-reared S. hyalinus become available. 展开更多
关键词 Sinocyclocheilus hyalinus CAVEFISH HORN Troglomorphism Synchrotron x-ray microtomography
下载PDF
Soft X-ray Tomography on HT-7
8
作者 陈开云 胡立群 +2 位作者 丁玥 马天鹏 段艳敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第4期472-476,共5页
The soft X-ray imaging system on HT-7 is introduced. Fourier-Bessel expansion method is used to reconstruct the soft X-ray emission distribution. Simulation results show that the inversion accuracy is associated with ... The soft X-ray imaging system on HT-7 is introduced. Fourier-Bessel expansion method is used to reconstruct the soft X-ray emission distribution. Simulation results show that the inversion accuracy is associated with the angular expansion limit and the hot core displacement. In addition, tomographic results of sawtooth oscillations in a typical low hybrid current drive (LHCD) plasma are presented. It is shown that the reconstructions are reliable to analyze the perturbative mode and the evolution. 展开更多
关键词 tomography SAWTOOTH soft x-ray
下载PDF
Soft X-ray Tomography and Sawtooth Oscillations during IBW in HT-7 Tokamak
9
作者 阮怀林 万宝年 +1 位作者 鲍抑 胡立群 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期851-858,共8页
Tomographic reconstructions of soft x-ray emissivity in the HT-7 tokamak have been obtained using 86 miniature soft-x-ray detectors. Because there are two-detector arrays which are distributed in horizontal and vertic... Tomographic reconstructions of soft x-ray emissivity in the HT-7 tokamak have been obtained using 86 miniature soft-x-ray detectors. Because there are two-detector arrays which are distributed in horizontal and vertical directions on one poloidal plane, two-dimensional images of x-ray emissivity are obtained without having resort to a rotational model. The algorithm of Fourier-Bessel expansion was employed. The data analysed so far have been used principally to study MHD instabilities, and the illustrative examples of the sawtooth crash in IBW-heated plasma are described. 展开更多
关键词 Soft x-ray tomography and Sawtooth Oscillations during IBW in HT-7 Tokamak HT MODE
下载PDF
Three-dimensional morphology of the Sinocyclocheilus hyalinus(Cypriniformes:Cyprinidae)horn based on synchrotron X-ray microtomography
10
作者 You HE Xiao-Yong CHEN +1 位作者 Ti-Qao XIAO Jun-Xing YANG 《Zoological Research》 SCIE CAS CSCD 北大核心 2013年第S05期128-134,共7页
Sinocyclocheilus is a cave-dwelling cyprinid genus endemic to southwest China.Several species possess a conspicuous horn on their head,which has been suggested as a constructive troglomorphic trait but lacks substanti... Sinocyclocheilus is a cave-dwelling cyprinid genus endemic to southwest China.Several species possess a conspicuous horn on their head,which has been suggested as a constructive troglomorphic trait but lacks substantial evidence.We used non-invasive,high spatial resolution synchrotron X-ray microtomography to investigate the three-dimensional(3D)morphology of the horn of Sinocyclocheilus hyalinus,one of eight such troglobiotic species.3D renderings demonstrated the osteological components,which were comprised of a rear wall comprised of the supraoccipital bone,a remaining frontal wall with numerous fenestrae,and the bottom continuous with the parietal and epiotic.A horn cavity occurred within the horn.The fenestrae in the frontal wall were continuous in the horn cavity and showed elaborate channeling,and were,connected to the cranial cavity by soft tissue.We tentatively called this configuration the“otocornual connection”due to its anatomic and putative functional similarity to the otolateralic connection in clupeids and loricariids,which provide an indirect pathway to enhance perception of underwater sound signals.This study provides a functional morphology context for further histological and physiological investigations of such horn structures in Sinocyclocheilus cavefish,and we suggest that the horn might enhance acoustic perception to compensate for visual loss in subterranean life,which warrants future physiological examination as lab-reared S.hyalinus become available. 展开更多
关键词 Sinocyclocheilus hyalinus CAVEFISH HORN Troglomorphism Synchrotron x-ray microtomography
下载PDF
Microstructure Evolution of Sandstone Cemented by Microbe Cement Using X-ray Computed Tomography 被引量:4
11
作者 RONG Hui QIAN Chunxiang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1134-1139,共6页
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica... The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone. 展开更多
关键词 microbe cement bio-sandstone microstructure evolution x-ray computed tomography CALCITE
下载PDF
Effects of dry-wet cycles on three-dimensional pore structure and permeability characteristics of granite residual soil using X-ray micro computed tomography 被引量:13
12
作者 Ran An Lingwei Kong +1 位作者 Xianwei Zhang Chengsheng Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第3期851-860,共10页
Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive to... Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results. 展开更多
关键词 Granite residual soil Dry-wet cycle x-ray micro computed tomography(micro-CT) Three-dimensional(3D)pore distribution Seepage simulations PERMEABILITY
下载PDF
Three dimensional distribution of surfactant in microspheres revealed by synchrotron radiation X-ray microcomputed tomography 被引量:2
13
作者 Li Wu Manli Wang +7 位作者 Vikramjeet Singh Haiyan Li Zhen Guo Shuangying Gui Peter York Tiqiao Xiao Xianzhen Yin Jiwen Zhang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2017年第4期326-334,共9页
This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion s... This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion solvent evaporation method using acetone and liquid paraffin system containing sucrose stearate as a surfactant. The fabricated microspheres were evaluated for encapsulation efficiency, particle size, production yield, and in vitro release characteristics. The internal structures of microspheres were characterized using synchrotron radiation X-ray microcomputed tomography(SR-μCT). The enhanced contrast made the sucrose stearate distinguished from Eudragit to have its three dimensional(3D) distribution. Results indicated that the content and concentration determined the state of sucrose stearate and had significant influences on the release kinetics of protein. The dispersity of sucrose stearate was the primary factor that controlled the structure of the microspheres and further affected the encapsulation efficiency, effective drug loading, as well as in vitro release behavior. In conclusion, the 3D internal distribution of surfactant in microspheres and its effects on protein release behaviors have been revealed for the first time. The highly resolved 3D architecture provides new evidence for the deep understanding of the microsphere formation mechanism. 展开更多
关键词 Three dimensional SYNCHROTRON radiation x-ray microcomputed tomography DISTRIBUTION MICROSPHERE SUCROSE STEARATE
下载PDF
Review of X-ray and computed tomography scan findings with a promising role of point of care ultrasound in COVID-19 pandemic 被引量:5
14
作者 Darshan Gandhi Kriti Ahuja +4 位作者 Hemal Grover Pranav Sharma Shantanu Solanki Nishant Gupta Love Patel 《World Journal of Radiology》 CAS 2020年第9期195-203,共9页
As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not... As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not only helps assess the disease at the time of diagnosis but also aids evaluation of response to management,it is critical to examine the role of different modalities currently in use,such as baseline X-rays and computed tomography scans carefully.In this article,we will draw attention to the critical findings for the radiologist.Further,we will look at point of care ultrasound,an increasingly a popular tool in diagnostic medicine,as a component of COVID-19 management. 展开更多
关键词 x-ray Computed tomography Point of care ultrasound COVID-19 CORONAVIRUS WUHAN
下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
15
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
下载PDF
Full-field mapping of internal strain distribution in red sandstone specimen under compression using digital volumetric speckle photography and X-ray computed tomography 被引量:5
16
作者 Lingtao Mao Jianping Zuo +1 位作者 Zexun Yuan Fu-Pen Chiang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第2期136-146,共11页
It is always desirable to know the interior deformation pattern when a rock is subjected to mechanicalload. Few experimental techniques exist that can represent full-field three-dimensional (3D) straindistribution i... It is always desirable to know the interior deformation pattern when a rock is subjected to mechanicalload. Few experimental techniques exist that can represent full-field three-dimensional (3D) straindistribution inside a rock specimen. And yet it is crucial that this information is available for fully understandingthe failure mechanism of rocks or other geomaterials. In this study, by using the newlydeveloped digital volumetric speckle photography (DVSP) technique in conjunction with X-ray computedtomography (CT) and taking advantage of natural 3D speckles formed inside the rock due to materialimpurities and voids, we can probe the interior of a rock to map its deformation pattern under load andshed light on its failure mechanism. We apply this technique to the analysis of a red sandstone specimenunder increasing uniaxial compressive load applied incrementally. The full-field 3D displacement fieldsare obtained in the specimen as a function of the load, from which both the volumetric and the deviatoricstrain fields are calculated. Strain localization zones which lead to the eventual failure of the rock areidentified. The results indicate that both shear and tension are contributing factors to the failuremechanism. 2015 Institute of Rock and Soil Mechanics, Chinese Academy of Sciences. Production and hosting byElsevier B.V. All rights reserved. 展开更多
关键词 Red sandstone Strain localization Uniaxial compression Digital volumetric speckle photography(DVSP) x-ray micro-tomography
下载PDF
Effect of slurry conditioning on flocculant-aided filtration of coal tailings studied by low-field nuclear magnetic resonance and X-ray micro-tomography 被引量:12
17
作者 Pengfei Hu Long Liang +2 位作者 Guangyuan Xie Shaoqi Zhou Yaoli Peng 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2020年第6期859-864,共6页
The present work aimed to study the effect of slurry conditioning on flocculant-aided filtration of coal tailings by the analysis of filtration kinetics and filter cake structure.Laboratory filtration tests of the coa... The present work aimed to study the effect of slurry conditioning on flocculant-aided filtration of coal tailings by the analysis of filtration kinetics and filter cake structure.Laboratory filtration tests of the coal tailings showed that both the shear rate and agitation time have significant effects on filtration rate and cake moisture.Moderate agitation at the shear rate of 92 s^-1 was favorable for fast filtration,but high cake moisture was encountered.The low-field 1H nuclear magnetic resonance(NMR)measurements of the filter cake showed that the slurry conditioning has a significant effect on the residual water in large pores and a negligible effect on the residual water in small pores.The X-ray micro-tomography(XRM)measurements indicated that the filter cake formed at the shear rate of 92 s^-1 has more macro-pores and higher porosity than that formed at the shear rate of 53 s1,hence more residual water was entrapped in filter cake.The slurry conditioning in the presence of flocculant will change the structure of filter cake and affect the filtration performance.There was a paradox between fast filtration rate and low filter cake moisture.The findings enable better understanding of the effect of slurry conditioning on flocculant-aided filtration of coal tailings. 展开更多
关键词 Coal tailings FILTRATION Slurry conditioning Nuclear magnetic resonance x-ray micro-tomography
下载PDF
Isotropic compression behavior of granular assembly with non-spherical particles by X-ray micro-computed tomography and discrete element modeling 被引量:1
18
作者 Nan Zhang Ahmadreza Hedayat +4 位作者 Shaoyang Han Runlin Yang Héctor Gelber Bolaños Sosa Juan JoséGonzález Cárdenas Guido Edgard SalasÁlvarez 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2021年第5期972-984,共13页
The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.Howe... The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.However,limited studies on investigating the microscopic behavior of the granular assembly with real particle shapes under isotropic compression were reported.In this study,X-ray computed tomography(mCT)and discrete element modeling(DEM)were utilized to investigate isotropic compression behavior of the granular assembly with regard to the particle morphological properties,such as particle sphericity,concavity and interparticle frictions.The mCT was first used to extract the particle morphological parameters and then the DEM was utilized to numerically investigate the influences of the particle morphological properties on the isotropic compression behavior.The image reconstruction from mCT images indicated that the presented particle quantification algorithm was robust,and the presented microscopic analysis via the DEM simulation demonstrated that the particle surface concavity significantly affected the isotropic compression behavior.The observations of the particle connectivity and local void ratio distribution also provided insights into the granular assembly under isotropic compression.Results found that the particle concavity and interparticle friction influenced the most of the isotropic compression behavior of the granular assemblies. 展开更多
关键词 x-ray computed tomography(mCT) Discrete element modeling(DEM) Isotropic compression Particle surface curvature Particle morphology
下载PDF
Kernel crack characteristics for X-ray computed microtomography(μCT)and their relationship with the breakage rate of maize varieties 被引量:2
19
作者 DONG Peng-fei XIE Rui-zhi +6 位作者 WANG Ke-ru MING Bo HOU Peng HOU Jun-feng XUE Jun LI Chao-hai LI Shao-kun 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2020年第11期2680-2689,共10页
The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mec... The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mechanical grain harvesting.However,conventional BR evaluation and measurement methods have challenges and limitations.Microstructural crack parameters evaluation of maize kernel is of great importance to BR.In this connection,X-ray computed microtomography(μ-CT)has proven to be a quite useful method for the assessment of microstructure,as it provides important microstructural parameters,such as object volume,surface,surface/volume ratio,number of closed pores,and others.X-ray computed microtomography is a non-destructive technique that enables the reuse of samples already measured and also yields bidimensional(2D)cross-sectional images of the sample as well as volume rendering.In this paper,six different maize hybrid genotypes are used as materials,and the BR of the maize kernels of each variety is tested in the field mechanical grain harvesting,and the BR is used as an index for evaluating the breakage resistance of the variety.The crack characteristic parameters of kernel were detected by X-ray micro-computed tomography,and the relationship between the BR and the kernel crack characteristics was analyzed by stepwise regression analysis.Establishing a relationship between crack characteristic parameters and BR of maize is vital for judging breakage resistance.The results of stepwise multiple linear regression(MLR)showed that the crack characteristics of the object surface,number of closed pores,surface of closed pores,and closed porosity percent were significantly correlated to the BR of field mechanical grain harvesting,with the standard partial regression coefficients of–0.998,–0.988,–0.999,and–0.998,respectively.The R2 of this model was 0.999.Results validation showed that the Stepwise MLR Model could well predict the BR of maize based on these four variables. 展开更多
关键词 breakage rate kernel crack MAIZE MICROSTRUCTURE x-ray computed microtomography
下载PDF
Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity 被引量:1
20
作者 张瀚铭 王林元 +3 位作者 李磊 闫镔 蔡爱龙 胡国恩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期557-565,共9页
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t... The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation. 展开更多
关键词 computed tomography image reconstruction sparsity exploitation nonlocal gradient
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部