期刊文献+
共找到5,027篇文章
< 1 2 250 >
每页显示 20 50 100
Aflibercept combined with triamcinolone acetonide in the treatment of diabetic macular edema:optical coherence tomography and optical coherence tomography angiography
1
作者 De-Shuang Li Hong-Xia Liao +4 位作者 Chuan-He Zhang Jian-Guo Huang Wei Chen Jing-Lin Zhang Bo Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期670-675,共6页
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone... AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography hyperreflective foci subretinal fluid foveal avascular zone AFLIBERCEPT
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
2
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
3
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography OCT-compatible instruments glaucoma surgery TRABECULECTOMY CANALOPLASTY
下载PDF
Three-dimensional choroidal vascularity index and choroidal thickness in fellow eyes of acute and chronic primary angle-closure using swept-source optical coherence tomography 被引量:1
4
作者 Hai-Li Huang Guan-Hong Wang +1 位作者 Liang-Liang Niu Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期42-52,共11页
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of... AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma. 展开更多
关键词 choroidal thickness choroidal vascularity index swept-source optical coherence tomography acute primary angle-closure chronic primary angle-closure glaucoma
下载PDF
Intravascular photoacoustic and optical coherence tomography imaging dual-mode system for detecting spontaneous coronary artery dissection: A feasibility study 被引量:1
5
作者 Yongwei Wang Yuyang Wan Zhongjiang Chen 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期77-86,共10页
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ... In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications. 展开更多
关键词 Spontaneous coronary artery dissection(SCAD) intravascular optical coherence tomography(IVOCT) intravascular photoacoustic imaging(IVPAI)
下载PDF
Automatic diagnosis of diabetic retinopathy using vision transformer based on wide-field optical coherence tomography angiography
6
作者 Zenan Zhou Huanhuan Yu +3 位作者 Jiaqing Zhao Xiangning Wang Qiang Wu Cuixia Dai 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期35-44,共10页
Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,... Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,wide-field OCTA(WF-OCTA)provided more abundant information including that of the peripheral retinal degenerative changes and it can contribute in accurately diagnosing DR.The need for an automatic DR diagnostic system based on WF-OCTA pictures attracts more and more attention due to the large diabetic population and the prevalence of retinopathy cases.In this study,automatic diagnosis of DR using vision transformer was performed using WF-OCTA images(12 mm×12 mm single-scan)centered on the fovea as the dataset.WF-OCTA images were automatically classified into four classes:No DR,mild nonproliferative diabetic retinopathy(NPDR),moderate to severe NPDR,and proliferative diabetic retinopathy(PDR).The proposed method for detecting DR on the test set achieves accuracy of 99.55%,sensitivity of 99.49%,and specificity of 99.57%.The accuracy of the method for DR staging reaches up to 99.20%,which has been proven to be higher than that attained by classical convolutional neural network models.Results show that the automatic diagnosis of DR based on vision transformer and WF-OCTA pictures is more effective for detecting and staging DR. 展开更多
关键词 Wide field optical coherence tomography angiography diabetic retinopathy vision transformer image classification
下载PDF
Predictive visual field outcomes after optic chiasm decompressive surgery by retinal vessels parameters using optical coherence tomography angiography
7
作者 Wen-Juan Yu Jin Xiao +3 位作者 Guang-Xin Wang Chang Jiang Wei Zha Rong-Feng Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期365-373,共9页
AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary ne... AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary nerve fiber layer(pRNFL)and ganglion cell complex(GCC).METHODS:This prospective longitudinal observational study included patients with chiasmal compression due to sellar region mass scheduled for decompressive surgery.Generalized estimating equations were used to compare retinal vessel density and retinal layer thickness preand post-operatively and with healthy controls.Logistic regression models were used to assess the relationship between preoperative GCC,pRNFL,SRCP,and RPC parameters and visual field recovery after surgery.RESULTS:The study included 43 eyes of 24 patients and 48 eyes of 24 healthy controls.Preoperative RPC and SRCP vessel density and pRNFL and GCC thickness were lower than healthy controls and higher than postoperative values.The best predictive GCC and pRNFL models were based on the superior GCC[area under the curve(AUC)=0.866]and the tempo-inferior pRNFL(AUC=0.824),and the best predictive SRCP and RPC models were based on the nasal SRCP(AUC=0.718)and tempo-inferior RPC(AUC=0.825).There was no statistical difference in the predictive value of the superior GCC,tempo-inferior pRNFL,and tempo-inferior RPC(all P>0.05).CONCLUSION:Compression of the optic chiasm by tumors in the saddle area can reduce retinal thickness and blood perfusion.This reduction persists despite the recovery of the visual field after decompression surgery.GCC,pRNFL,and RPC can be used as sensitive predictors of visual field recovery after decompression surgery. 展开更多
关键词 sellar region mass retinal vessels optic chiasm optical coherence tomography angiography visual field decompressive surgery
下载PDF
Distal-scanning common path probe for optical coherence tomography
8
作者 Zhengyu Chen Bin He +8 位作者 Zichen Yin Zhangwei Hu Yejiong Shi Chengming Wang Xiao Zhang Ning Zhang Linkai Jing Guihuai Wang Ping Xue 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期84-92,共9页
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be... In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus. 展开更多
关键词 Common path optical coherence tomography endoscopic probe
下载PDF
Automated evaluation of parapapillary choroidal microvasculature in crowded optic discs:a controlled,optical coherence tomography angiography study
9
作者 Hatice Arda Hidayet Sener +5 位作者 Ozge Temizyurek Hatice Kubra Sonmez Duygu Gulmez Sevim Cem Evereklioglu Fatih Horozoglu Ayse Busra Gunay Sener 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期113-118,共6页
AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control... AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control subjects were enrolled in the study.One eye of each individual was included and OCT-A scans of optic discs were obtained in a 4.5×4.5 mm^(2) rectangular area.Radial peripapillary capillary(RPC)density,peripapillary retinal nerve fiber layer(pRNFL)thickness,cup volume,rim area,disc area,cup-to-disc(c/d)area ratio,and vertical c/d ratio were obtained automatically using device software.Automated parapapillary choroidal microvasculature(PPCMv)density was calculated using MATLAB software.When the vertical c/d ratio of the optic disc was absent or small cup,it was considered as a crowded disc.RESULTS:The mean signal strength index of OCT-A images was similar between the crowded discs and control eyes(P=0.740).There was no difference in pRNFL between the two groups(P=0.102).There were no differences in RPC density in whole image(P=0.826)and peripapillary region(P=0.923),but inside disc RPC density was higher in crowded optic discs(P=0.003).The PPCMv density in the inner-hemisuperior region was also lower in crowded discs(P=0.026).The pRNFL thickness was positively correlated with peripapillary RPC density(r=0.498,P<0.001).The inside disc RPC density was negatively correlated with c/d area ratio(r=-0.341,P=0.002).CONCLUSION:The higher inside disc RPC density and lower inner-hemisuperior PPCMv density are found in eyes with crowded optic discs. 展开更多
关键词 crowded optic disc ischemic optic neuropathy optical coherence tomography angiography parapapillary choroidal microvasculature
下载PDF
Evaluation of retinal and choroidal thickness changes in overweight and obese adults without ocular symptoms by swept-source optical coherence tomography
10
作者 Qing-Jian Li Sheng-Mei Zhou +7 位作者 Ling-Yu Zhang An-Ni Lin Yang Zhang Jing Jiang Xin Che Yi-Wen Qian Yan Liu Zhi-Liang Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期707-712,共6页
AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass... AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass index(BMI)results,the adults enrolled in the cross-sectional study were divided into the normal group(18.50≤BMI<25.00 kg/m^(2)),the overweight group(25.00≤BMI<30.00 kg/m^(2)),and the obesity group(BMI≥30.00 kg/m^(2)).The one-way ANOVA and the Chi-square test were used for comparisons.Pearson’s correlation analysis was used to evaluate the relationships between the measured variables.RESULTS:This research covered the left eyes of 3 groups of 434 age-and sex-matched subjects each:normal,overweight,and obesity.The mean BMI was 22.20±1.67,26.82±1.38,and 32.21±2.35 kg/m^(2) in normal,overweight and obesity groups,respectively.The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group(P<0.05 for all),while the retinal thickness of the three groups did not differ significantly.Pearson’s correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness,but no significant correlation was observed between BMI and retinal thickness.CONCLUSION:Choroidal thickness is decreased in people with overweight or obesity.Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults. 展开更多
关键词 OVERWEIGHT OBESITY body mass index choroidal thickness retinal thickness swept-source optical coherence tomography
下载PDF
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
11
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
下载PDF
Detecting early changes in choroidal vascularity and thickness using optical coherence tomography in patients with corneal crosslinking for keratoconus
12
作者 Selim Doganay Mehmet Omer Kiristioglu +1 位作者 Derya Doganay Elif Kacmaz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1267-1272,共6页
AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal cr... AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance. 展开更多
关键词 KERATOCONUS corneal crosslinking choroidal vascularity index enhanced depth imaging optical coherence tomography
下载PDF
Retinal capillary plexus in Parkinson’s disease using optical coherence tomography angiography
13
作者 Ioannis Giachos Spyridon Doumazos +6 位作者 Anastasia Tsiogka Konstantina Manoli George Tagaris Tryfon Rotsos Vassilios Kozobolis Ioannis Iliopoulos Marilita Moschos 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期131-136,共6页
AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of... AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of PD patients examined in the Ophthalmology Department of the General Hospital of Athens,“Georgios Gennimatas”from March 2021 to March 2022 was conducted.Totally 44 patients with PD were included and 18 healthy controls were examined,hence a total of 124 eyes were enrolled in the study.The foveal and parafoveal superficial and deep capillary plexus vascular density(fSCP-VD,fDCP-VD,pSCP-VD,pDCP-CD)and foveal avascular zone(FAZ)were quantified with OCTA.Optical coherence tomography(OCT)was used to measure macular thickness.Our statistical analysis was conducted by using a mixed effect linear regression model.RESULTS:After adjustment for age and gender,the mean parafoveal superficial capillary plexus vascular density(pSCP-VD)and mean parafoveal deep capillary plexus vascular density(pDCP-VD)were significantly decreased in individuals with PD(P<0.001 in both)by-2.35(95%CI-3.3,-1.45)and-7.5(95%CI-10.4,-4.6)respectively.fSCP-VD and fDCP-VD didn’t approach statistical significance.The FAZ area and perimeter were significantly decreased(P<0.001 in both)by-0.1 mm^(2)(95%CI-0.13,-0.07)and-0.49 mm^(2)(95%CI-0.66,-0.32)respectively.Circularity didn’t approach statistical significance.Central retinal thickness(CRT)was significantly decreased in individuals with PD(P<0.001)by-23.1μm(95%CI-30.2,-16)and temporal retinal thickness(TRT)was decreased(P=0.025)by-11μm(95%CI-22,-1.5)while nasal retinal thickness(NRT)only approached statistical significance(P=0.066).CONCLUSION:The mean pSCP-VD,pDCP-VD,CRT and TRT are significantly decreased and FAZ is altered in individuals with PD.These findings can be potentially used as biomarkers for the diagnosis and evaluation of early PD. 展开更多
关键词 Parkinson’s disease optical coherence tomography angiography retinal vascular density foveal avascular zone
下载PDF
Retinal microcirculation changes in prediabetic patients with shortterm increased blood glucose using optical coherence tomography angiography
14
作者 Bing-Jing Lv Hang-Jia Zuo +6 位作者 Qi-Fu Li Fan-Fan Huang Tong Zhang Rong-Xi Huang Shi-Jie Zheng Wen-Juan Wan Ke Hu 《World Journal of Radiology》 2024年第9期407-417,共11页
BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study ana... BACKGROUND Retinal microcirculation alterations are early indicators of diabetic microvascular complications.Optical coherence tomography angiography(OCTA)is a noninvasive method to assess these changes.This study analyzes changes in retinal microcirculation in prediabetic patients during short-term increases in blood glucose using OCTA.AIM To investigate the changes in retinal microcirculation in prediabetic patients experiencing short-term increases in blood glucose levels using OCTA.METHODS Fifty volunteers were divided into three groups:Group 1[impaired fasting glucose(IFG)or impaired glucose tolerance(IGT)],Group 2(both IFG and IGT),and a control group.Retinal microcirculation parameters,including vessel density(VD),perfusion density(PD),and foveal avascular zone(FAZ)metrics,were measured using OCTA.Correlations between these parameters and blood glucose levels were analyzed in both the fasting and postprandial states.RESULTS One hour after glucose intake,the central VD(P=0.023),central PD(P=0.026),and parafoveal PD(P<0.001)were significantly greater in the control group than in the fasting group.In Group 1,parafoveal PD(P<0.001)and FAZ circularity(P=0.023)also increased one hour after glucose intake.However,no significant changes were observed in the retinal microcirculation parameters of Group 2 before or after glucose intake(P>0.05).Compared with the control group,Group 1 had a larger FAZ area(P=0.032)and perimeter(P=0.018),whereas Group 2 had no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Compared with Group 1,Group 2 had greater central VD(P=0.013)and PD(P=0.008)and a smaller FAZ area(P=0.012)and perimeter(P=0.010).One hour after glucose intake,Group 1 had a larger FAZ area(P=0.044)and perimeter(P=0.038)than did the control group,whereas Group 2 showed no significant differences in retinal microcirculation parameters compared with the control group(P>0.05).Group 2 had greater central VD(P=0.042)and PD(P=0.022)and a smaller FAZ area(P=0.015)and perimeter(P=0.016)than Group 1.At fasting,central PD was significantly positively correlated with blood glucose levels(P=0.044),whereas no significant correlations were found between blood glucose levels and OCTA parameters one hour after glucose intake.CONCLUSION A short-term increase in blood glucose has a more pronounced effect on retinal microcirculation in prediabetic patients with either IFG or IGT. 展开更多
关键词 PREDIABETES Blood glucose optical coherence tomography angiography Retinal microcirculation Central vessel density Impaired fasting glucose Impaired glucose tolerance
下载PDF
In vivo quantification of human aqueous veins by enhanced depth imaging optical coherence tomography and optical coherence tomography angiography images 被引量:1
15
作者 Zhi-Qi Chen Wei Chen +3 位作者 Chao-Hua Deng Jing-Min Guo Hong Zhang Jun-Ming Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第9期1482-1488,共7页
AIM:To investigate the aqueous vein in vivo by using enhanced depth imaging optical coherence tomography(EDI-OCT)and optical coherence tomography angiography(OCTA).METHODS:In this cross-sectional comparative study,30 ... AIM:To investigate the aqueous vein in vivo by using enhanced depth imaging optical coherence tomography(EDI-OCT)and optical coherence tomography angiography(OCTA).METHODS:In this cross-sectional comparative study,30 healthy participants were enrolled.Images of the aqueous and conjunctival veins were captured by EDI-OCT and OCTA before and after water loading.The area,height,width,location depth and blood flow of the aqueous vein and conjunctival vein were measured by Image J software.RESULTS:In the static state,the area of the aqueous vein was 8166.7±3272.7μm^(2),which was smaller than that of the conjunctival vein(13690±7457μm^(2),P<0.001).The mean blood flow density of the aqueous vein was 35.3%±12.6%,which was significantly less than that of the conjunctival vein(51.5%±10.6%,P<0.001).After water loading,the area of the aqueous vein decreased significantly from 8725.8±779.4μm^(2)(baseline)to 7005.2±566.2μm^(2)at 45min but rose to 7863.0±703.2μm^(2)at 60min(P=0.032).The blood flow density of the aqueous vein decreased significantly from 41.2%±4.5%(baseline)to 35.4%±3.2%at 30min but returned to 45.6%±3.6%at 60min(P=0.021).CONCLUSION:The structure and blood flow density of the aqueous vein can be effectively evaluated by OCT and OCTA.These may become biological indicators to evaluate aqueous vein changes and aqueous outflow resistance under different interventions in glaucoma patients. 展开更多
关键词 aqueous vein optical coherence tomography optical coherence tomography angiography water drinking test
下载PDF
Retinal thickness and vascular parameters using optical coherence tomography in Alzheimer's disease:a meta-analysis
16
作者 Samran Sheriff Ting Shen +8 位作者 Sandra Abdal Danit Saks Mehdi Mirzaei Veer Gupta Nitin Chitranshi Yuyi You Angela Schultz Stuart L.Graham Vivek Gupta 《Neural Regeneration Research》 SCIE CAS CSCD 2023年第11期2504-2513,共10页
Examining the retinal tissue has the potential to provide a unique method and technique to quantify Alzheimer’s disease-related changes in participants at various stages of the disease.In this metaanalysis,we aimed t... Examining the retinal tissue has the potential to provide a unique method and technique to quantify Alzheimer’s disease-related changes in participants at various stages of the disease.In this metaanalysis,we aimed to investigate the association of various optical coherence tomography parameters with Alzheimer’s disease and whether retinal measurements can be used to diffe rentiate between Alzheimer’s disease and control subjects.Scientific databases including Google Schola r,Web of Science,and PubMed were systematically searched for published articles that evaluated retinal nerve fiber layer thickness and retinal microvascular network in Alzheimer’s disease and control subjects.Seventy-three studies(5850 participants,including 2249 Alzheimer’s disease patients and 3601controls) were included in this meta-analysis.Relative to controls,Alzheimer’s disease patients had a significantly lower global retinal nerve fiber layer thickness(standardized mean difference [SMD]=-0.79,95% confidence intervals [CI]:-1.03 to-0.54,P <0.00001) as well as each quadrant being thinner in Alzheimer’s disease versus controls.Regarding macular paramete rs,values measured by optical coherence tomography were significantly lower in Alzheimer’s disease than controls for macular thickness(pooled SMD:-0.44,95% CI:-0.67 to-0.20,P=0.0003),foveal thickness(pooled SMD=-0.39,95% CI:-0.58 to-0.19,P <0.0001),ganglion cell inner plexiform layer(SMD=-1.26,95% CI:-2.24 to-0.27,P=0.01) and macular volume(pooled SMD=-0.41,95% CI-0.76 to-0.07,P=0.02).Analysis using optical coherence tomography angiography parameters revealed mixed results between Alzheimer’s disease and controls.Superficial vessel density(pooled SMD=-0.42,95% CI:-0.68 to-0.17,P=0.0001) and deep vessel density(pooled SMD=-0.46,95% CI:-0.75 to-0.18,P=0.001) were found to be thinner in Alzheimer’s disease patients whereas the foveal avascular zone(SMD=0.84,95% CI:0.17-1.51,P=0.01) was larger in controls.Vascular density and thickness of various retinal laye rs were decreased in Alzheimer’s disease patients compared to controls.Our results provide evidence for optical coherence tomography technology having the potential to detect retinal and microvascular changes in patients diagnosed with Alzheimer’s disease and aid in monito ring and early diagnosis methods. 展开更多
关键词 Alzheimer’s disease foveal avascular zone macular thickness optical coherence tomography optical coherence tomography angiography RETINA retinal nerve fiber layer vessel density
下载PDF
Bibliometric analysis of artificial intelligence and optical coherence tomography images:research hotspots and frontiers 被引量:2
17
作者 Hai-Wen Feng Jun-Jie Chen +2 位作者 Zhi-Chang Zhang Shao-Chong Zhang Wei-Hua Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第9期1431-1440,共10页
AIM:To explore the latest application of artificial intelligence(AI)in optical coherence tomography(OCT)images,and to analyze the current research status of AI in OCT,and discuss the future research trend.METHODS:On J... AIM:To explore the latest application of artificial intelligence(AI)in optical coherence tomography(OCT)images,and to analyze the current research status of AI in OCT,and discuss the future research trend.METHODS:On June 1,2023,a bibliometric analysis of the Web of Science Core Collection was performed in order to explore the utilization of AI in OCT imagery.Key parameters such as papers,countries/regions,citations,databases,organizations,keywords,journal names,and research hotspots were extracted and then visualized employing the VOSviewer and CiteSpace V bibliometric platforms.RESULTS:Fifty-five nations reported studies on AI biotechnology and its application in analyzing OCT images.The United States was the country with the largest number of published papers.Furthermore,197 institutions worldwide provided published articles,where University of London had more publications than the rest.The reference clusters from the study could be divided into four categories:thickness and eyes,diabetic retinopathy(DR),images and segmentation,and OCT classification.CONCLUSION:The latest hot topics and future directions in this field are identified,and the dynamic evolution of AIbased OCT imaging are outlined.AI-based OCT imaging holds great potential for revolutionizing clinical care. 展开更多
关键词 artificial intelligence optical coherence tomography BIBLIOMETRIC deep learning machine learning
下载PDF
Microstructural morphology and visual acuity outcome in eyes with epiretinal membrane before,during,and after membrane peeling in intraoperative optical coherence tomography assisted macular surgery 被引量:2
18
作者 Melanie Weschta Moritz Pettenkofer +3 位作者 Julian EKlaas Nikolaus Feucht Chris PLohmann Mathias Maier 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期748-754,共7页
AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected... AIM:To measure the difference of intraoperative central macular thickness(CMT)before,during,and after membrane peeling and investigate the influence of intraoperative macular stretching on postoperative best corrected visual acuity(BCVA)outcome and postoperative CMT development.METHODS:A total of 59 eyes of 59 patients who underwent vitreoretinal surgery for epiretinal membrane was analyzed.Videos with intraoperative optical coherence tomography(OCT)were recorded.Difference of intraoperative CMT before,during,and after peeling was measured.Pre-and postoperatively obtained BCVA and spectral-domain OCT images were analyzed.RESULTS:Mean age of the patients was 70±8.13y(range 46-86y).Mean baseline BCVA was 0.49±0.27 log MAR(range 0.1-1.3).Three and six months postoperatively the mean BCVA was 0.36±0.25(P=0.01 vs baseline)and 0.38±0.35(P=0.08 vs baseline)log MAR respectively.Mean stretch of the macula during surgery was 29%from baseline(range 2%-159%).Intraoperative findings of macular stretching did not correlate with visual acuity outcome within 6mo after surgery(r=-0.06,P=0.72).However,extent of macular stretching during surgery significantly correlated with less reduction of CMT at the fovea centralis(r=-0.43,P<0.01)and 1 mm nasal and temporal from the fovea(r=-0.37,P=0.02 and r=-0.50,P<0.01 respectively)3mo postoperatively.CONCLUSION:The extent of retinal stretching during membrane peeling may predict the development of postoperative central retinal thickness,though there is no correlation with visual acuity development within the first 6mo postoperatively. 展开更多
关键词 retinal imaging treatment surgery intraoperative optical coherence tomography epiretinal membrane
下载PDF
Evaluation of optic nerve head vessels density changes after phacoemulsification cataract surgery using optical coherence tomography angiography 被引量:1
19
作者 Ze-Hui Zhu Yin-Ying Zhao +4 位作者 Rui Zou Han Zou Jia-Yan Fang Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第6期884-890,共7页
·AIM:To evaluate optic nerve head(ONH)vessel density(VD)changes after cataract surgery using optical coherence tomography angiography(OCTA).·METHODS:This was a prospective observational study.Thirty-four eye... ·AIM:To evaluate optic nerve head(ONH)vessel density(VD)changes after cataract surgery using optical coherence tomography angiography(OCTA).·METHODS:This was a prospective observational study.Thirty-four eyes with mild/moderate cataracts were included.ONH scans were obtained before and 3mo after cataract surgery using OCTA.Radial peripapillary capillary(RPC)density,all VD,large VD and retinal nerve fiber layer thickness(RNFLT)in total disc,inside disc,and different peripapillary sectors were assessed and analyzed.Image quality score(QS),fundus photography grading and bestcorrected visual acuity(BCVA)were also collected,and correlation analyses were performed between VD change and these parameters.·RESULTS:Compared with baseline,both RPC and all VD increased in inside disc area 3mo postoperatively(from 47.5%±5.3%to 50.2%±3.7%,and from 57.87%±4.30%to 60.47%±3.10%,all P<0.001),but no differences were observed in peripapillary area.However,large VD increased from 5.63%±0.77%to 6.47%±0.72%in peripapillary ONH region(P<0.001).RPC decreased in inferior and superior peripapillary ONH parts(P=0.019,<0.001 respectively).There were obvious negative correlations between RPC change and large VD change in inside disc,superior-hemi,and inferior-hemi(r=-0.419,-0.370,and-0.439,P=0.017,0.044,and 0.015,respectively).No correlations were found between VD change and other parameters including QS change,fundus photography grading,postoperative BCVA,and postoperative peripapillary RNFLT.·CONCLUSION:RPC density and all VD in the inside disc ONH region increase 3mo after surgery in patients with mild to moderate cataract.No obvious VD changes are found in peripapillary area postoperatively. 展开更多
关键词 PHACOEMULSIFICATION CATARACT optical coherence tomography angiography vessel density optic nerve head
下载PDF
Retinal neurodegeneration in metabolic syndrome:a spectral optical coherence tomography study
20
作者 Evrim Polat Ekrem Celik +1 位作者 Mesut Togac Afsun Sahin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期224-232,共9页
AIM:To evaluate the effects of metabolic syndrome(Met S)on retinal neurodegeneration by optical coherence tomography(OCT).METHODS:Patients diagnosed as Met S were compared with the age and sex-matched healthy control ... AIM:To evaluate the effects of metabolic syndrome(Met S)on retinal neurodegeneration by optical coherence tomography(OCT).METHODS:Patients diagnosed as Met S were compared with the age and sex-matched healthy control group(CG).Waist circumference measurements,fasting serological biochemical tests,and systemic blood pressures of all participants were evaluated.The Met S group was divided into 3 subgroups according to the number of Met S components:hypertension,diabetes mellitus,dyslipidemia(low-,high-density lipoprotein,hypertriglyceridemia),and visceral obesity findings;3-component Met S3,4-component Met S4,and all-component Met S5.All patients underwent complete eye examination and spectral OCT retinal imaging.RESULTS:Totally 58 eyes of 58 patients were included in the Met S group and 63 eyes of 63 age and sex-matched healthy subjects were included in CG.Met S group was composed of 22 subjects in Met S3,21 subjects in Met S4,and 15 subjects in the Met S5 subgroup.Mean foveal thickness(Met S,218.7±23.1μm vs CG,228.8±21.9μm,P=0.015),mean inferior(Met S,283.4±17.0μm vs CG,288.7±38.4μm,P=0.002),superior(Met S,287.0±18.5μm vs CG 297.3±17.1μm,P=0.001),nasal(Met S 287.3±16.7μm vs CG 297.9±13.9μm,P=0.000)and temporal(274.5±17.6μm vs CG 285.6±13.6μm,P=0.000)thickness in the 3 mm Early Treatment of Diabetic Retinopathy Study(ETDRS)circle was significantly lower in the Met S group.There was no statistically significant difference in the mean inferior,superior,nasal,and temporal thickness of 6 mm ETDRS circle,total macular volume,peripapillary and macular retinal nerve fiber layer,macular ganglion cell layer with inner plexiform layer,and ganglion cell complex.No statistically significant difference was found in these values between the Met S3,Met S4,and the Met S5 groups.CONCLUSION:A significant reduction in central macular region thickness in Met S is detected and macular thickness is more susceptible to Met S induced neurodegeneration than peripapillary retinal nerve fiber layer. 展开更多
关键词 metabolic syndrome retinal neurodegeneration HYPERTENSION diabetes mellitus DYSLIPIDEMIA optical coherence tomography
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部