期刊文献+
共找到89,881篇文章
< 1 2 250 >
每页显示 20 50 100
Effectiveness of magnetic resonance imaging and spiral computed tomography in the staging and treatment prognosis of colorectal cancer
1
作者 Lu-Na Bai Lu-Xian Zhang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2135-2144,共10页
BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosi... BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosis of CRC are crucial for improving treatment success and patient survival rates.Recently,imaging techniques have been hypothesized to be essential in managing CRC,with magnetic resonance imaging(MRI)and spiral computed tomography(SCT)playing a significant role in enhancing diagnostic and treatment approaches.AIM To explore the effectiveness of MRI and SCT in the preoperative staging of CRC and the prognosis of laparoscopic treatment.METHODS Ninety-five individuals admitted to Zhongshan Hospital Xiamen University underwent MRI and SCT and were diagnosed with CRC.The precision of MRI and SCT for the presurgical classification of CRC was assessed,and pathological staging was used as a reference.Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of blood volume,blood flow,time to peak,permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction on the prognosis of patients with CRC.RESULTS Pathological biopsies confirmed the following CRC stages:23,23,32,and 17 at T1,T2,T3,and T4,respectively.There were 39 cases at the N0 stage,22 at N1,34 at N2,44 at M0 stage,and 51 at M1.Using pathological findings as the benchmark,the combined use of MRI and SCT for preoperative TNM staging in patients with CRC demonstrated superior sensitivity,specificity,and accuracy compared with either modality alone,with a statistically significant difference in accuracy(P<0.05).Receiver operating characteristic curve analysis revealed the predictive values for laparoscopic treatment prognosis,as indicated by the areas under the curve for blood volume,blood flow,time to peak,and permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction were 0.750,0.683,0.772,0.761,0.709,0.719,and 0.910,respectively.The corresponding sensitivity and specificity values were also obtained(P<0.05).CONCLUSION MRI with SCT is effective in the clinical diagnosis of patients with CRC and is worthy of clinical promotion. 展开更多
关键词 Magnetic resonance imaging spiral computed tomography Colorectal cancer PROGNOSIS Receiver operating characteristic curve Retrospective study
下载PDF
Efficacy of multi-slice spiral computed tomography in evaluating gastric cancer recurrence after endoscopic submucosal dissection 被引量:2
2
作者 Jian-Jun Yin Xiao Hu +1 位作者 Sen Hu Guo-Hong Sheng 《World Journal of Gastrointestinal Oncology》 SCIE 2023年第9期1636-1643,共8页
BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enha... BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enhance clinical treatment of the disease.AIM To explore the role of computed tomography(CT)recurrence in evaluating EGC after ESD treatment.METHODS We retrospectively recruited patients from our endoscopy department,between January 2002 and December 2015,and analyzed their basic characteristics,including symptoms,CT results,and results of endoscopy with biopsy,among others.RESULTS Among a total of 2150 patients EGC patients surveyed,1362 met our inclusion and exclusion criteria and were therefore enrolled in our study.The cohort’s sensitivity of CT for recurrent GC and specificity were 44.22%and 43.86%,respectively,with negative and positive predictive values of 40.15%(275/685)and 48.01%(325/677),respectively.The area under the curve of arterial and venous CT values for recurrent EGC were 0.545,and 0.604,respectively.Receiver operating characteristic curve revealed no statistically significant differences between arterial and venous CT values for recurrent EGC.CONCLUSION Enhanced CT has superior diagnostic efficacy,but less accuracy,compared to gold standard techniques in patients with recurrent EGC. 展开更多
关键词 Computed tomography Early gastric cancer Gastric cancer Multi-slice spiral computed tomography
下载PDF
Segmental radiofrequency ablation of pulmonary vein ostia for patients with refractory paroxysmal atrial fibrillation using multi-slice spiral computed tomography guidance 被引量:6
3
作者 JIANG Chen-yang(蒋晨阳) +7 位作者 WANG Jian-an(王建安) HE Hong(何红) SUN Yong(孙勇) ZHOU Bin-quan(周斌全) 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第12期1153-1156,共4页
Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral ... Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT) guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32-79) years and no obvious organic heart disease. Before ablation, patients received MSCT to generate 3-dimentional image of the left atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation ofPV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1 time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening. 展开更多
关键词 Atrial fibrillation Pulmonary vein Radiofrequency ablation Multi-slice spiral computed tomography
下载PDF
Multi-slice spiral computed tomography in diagnosing unstable pelvic fractures in elderly and effect of less invasive stabilization 被引量:5
4
作者 Jian-Guo Huang Zhi-Yuan Zhang +2 位作者 Liang Li Guang-Bao Liu Xiong Li 《World Journal of Clinical Cases》 SCIE 2022年第14期4470-4479,共10页
BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can c... BACKGROUND Older people are more likely to experience pelvic fractures than younger people.Multi-slice spiral computed tomography(CT)uses three-dimensional(3D)reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of fractures and detect fractures at a higher rate.AIM To investigate the clinical value of multi-slice spiral CT 3D reconstruction in the diagnosis of unstable pelvic fractures in the elderly as well as the effect of less invasive stabilization.METHODS A total of 86 patients with unstable pelvic fractures treated between March 2016 and March 2019 underwent femoral supracondylar bone traction before surgery.Pelvic radiography and multi-row spiral CT were performed successively once the patient’s vital signs and hemodynamic indices were stable.Secondary processing of the original data was performed to obtain 3D reconstruction images and determine the vertical displacement of the pelvis.After basic or complete reduction,minimally invasive internal fixation using hollow lag screws was performed.The detection rates of fracture location and classification by X-ray and CT reconstruction were compared.Patients were divided into two groups according to the presence or absence of preoperative 3D reconstruction to compare postoperative reduction,wound healing time,fracture healing time,hospitalization time,visual analog scale(VAS)score,poor internal fixation,and functional recovery.RESULTS The diagnostic coincidence rates of X-rays for pubic symphysis,ilium wing,sacroiliac periarticular,and sacral fractures were lower than those of CT reconstruction.The coincidence rate of CT reconstruction in the clinical classification of pelvic fractures was 100%,whereas 11 cases were misdiagnosed by X-ray;the total coincidence rate was 87.21%.The total excellent and good rates of postoperative reduction were significantly higher in the study group than in the control group(P<0.05).The wound healing,fracture healing,and hospitalization times were significantly shorter in the study group than in the control group(P<0.05).The VAS scores decreased in both groups postoperatively and were lower in the study group than in the control group(P<0.05).The total incidence of poor postoperative internal fixation was significantly lower in the study group than in the control group(P<0.05).The overall rate of postoperative functional recovery was significantly higher in the study group than in the control group(P<0.05).CONCLUSION Multi-slice spiral CT has high guiding significance for the diagnosis,classification,and treatment of unstable pelvic fractures in the elderly.Preoperative 3D reconstruction can effectively shorten the operation time and promote fracture healing,while minimally invasive internal fixation can effectively reduce pain and promote functional recovery of fracture sites,making it worthy of clinical application. 展开更多
关键词 Multi-slice spiral computed tomography Three-dimensional reconstruction Unstable pelvic fracture Minimally invasive internal fixation Diagnostic value
下载PDF
Multi-slice spiral computed tomography in differential diagnosis of gastric stromal tumors and benign gastric polyps,and gastric stromal tumor risk stratification assessment 被引量:4
5
作者 Xiao-Long Li Peng-Fei Han +2 位作者 Wei Wang Li-Wei Shao Ying-Wei Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2022年第10期2004-2013,共10页
BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of t... BACKGROUND The biological characteristics of gastric stromal tumors are complex,and their incidence has increased in recent years.Gastric stromal tumors(GST)have potential malignant tendencies,and the probability of transformation into malignant tumors is as high as 20%-30%.AIM To investigate the value of multi-slice spiral computed tomography(MSCT)in the differential diagnosis of GST and benign gastric polyps,and GST risk stratification assessment.METHODS We included 64 patients with GST(GST group)and 60 with benign gastric polyps(control group),confirmed by pathological examination after surgery in PLA General Hospital,from January 2016 to June 2021.The differences in the MSCT imaging characteristic parameters and enhanced CT values between the two groups before surgery were compared.According to the National Institutes of Health’s standard,GST is divided into low-and high-risk groups for MSCT imaging characteristic parameters and enhanced CT values.RESULTS The incidences of extraluminal growth,blurred boundaries,and ulceration in the GST group were significantly higher than those in the control group(P<0.05).The CT values and enhanced peak CT values in the arterial phase in the CST group were higher than those in the control group(P<0.05).The MSCT differential diagnosis of GST and gastric polyp sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and areas under the curve(AUCs)were 73.44%,83.33%,26.56%,16.67%,0.784,respectively.The receiver operating characteristic curves were plotted with the arterial CT value and enhanced peak CT value,with a statistical difference.The results showed that the sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of arterial CT in the differential diagnosis of GST and gastric polyps were 80.18%,62.20%,19.82%,37.80%,and 0.710,respectively.The sensitivity,specificity,misdiagnosis rate,missed diagnosis rate,and AUC value of the enhanced peak CT value in the differential diagnosis of GST and gastric polyps were 67.63%,60.40%,32.37%,39.60%,and 0.710,respectively.The incidence of blurred lesion boundaries and ulceration in the high-risk group was significantly higher than that in the low-risk group(P<0.05).The arterial phase and enhanced peak CT values in the high-risk group were significantly higher than those in the low-risk group(P<0.05).CONCLUSION Presurgical MSCT examination has important value in the differential diagnosis of GST and gastric benign polyps and can effectively evaluate the risk grade of GST patients. 展开更多
关键词 Multi-slice spiral computed tomography Differential diagnosis Gastric stromal tumor Benign gastric polyps Risk stratification
下载PDF
3D Reconstruction with Spiral Computed Tomography in Choroidal Osteoma 被引量:1
6
作者 Francisco Javier Ascaso Laura Herrera +4 位作者 Laura Villén Rafael Lasierra Juan Ibanez Diana Pérez José Angel Cristóbal 《Open Journal of Ophthalmology》 2013年第1期4-6,共3页
Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtap... Choroidal osteoma (CO) is a rare, ossifying benign tumor originated in the choroid that typically occurs in otherwise healthy young women (1,2). It is characterized by a yellowish, well demarcated lesion in the juxtapapillary or macular area. The diagnosis is clinical and can be confirmed with the use of fluorescein or indocyanine angiography, optical coherence tomography, computed tomography or magnetic resonance imaging. Choroidal neovascularization or subretinal fluid, the main causes for vision loss, can be treated with laser therapy, photodynamic therapy or intravitreal antivascular endothelial growth factor therapy. We present a case of choroidal osteoma, showing the role of the high resolution 3D spiral computed tomography. 展开更多
关键词 Choroidal Osteoma 3D spiral Computed tomography ULTRASONOGRAPHY Fluorescein Angiography
下载PDF
Diagnostic ability of multi-detector spiral computed tomography for pathological lymph node metastasis of advanced gastric cancer 被引量:7
7
作者 Zhi-Yong Jiang Shinichi Kinami +5 位作者 Naohiko Nakamura Takashi Miyata Hideto Fujita Hiroyuki Takamura Nobuhiko Ueda Takeo Kosaka 《World Journal of Gastrointestinal Oncology》 SCIE CAS 2020年第4期435-446,共12页
BACKGROUND The reliability of preoperative nodal diagnosis of advanced gastric cancer by multi-detector spiral computed tomography(MDCT)is still unclear.AIM To examine the diagnostic ability of MDCT more precisely by ... BACKGROUND The reliability of preoperative nodal diagnosis of advanced gastric cancer by multi-detector spiral computed tomography(MDCT)is still unclear.AIM To examine the diagnostic ability of MDCT more precisely by using data on intranodal pathological metastatic patterns.METHODS A total of 108 patients with advanced gastric cancer who underwent MDCT and curative gastrectomy at Kanazawa Medical University Hospital were enrolled in this study.The nodal sizes measured on computed tomography(CT)images were compared with the pathology results.A receiver-operating characteristic curve was constructed,from which the critical value(CV)was calculated by using the data of the first 69 patients retrospectively.By using the CV,sensitivity and specificity were calculated with prospectively collected data from 39 consecutive patients.This enabled a more precise one-to-one correspondence of lymph nodes between CT and pathological examination by using the size data of lymph node mapping.The intranodal pathological metastatic patterns were classified into the following four types:Small nodular,peripheral,large nodular,and diffuse.RESULTS Although all the cases were clinically suspected as having metastasis,81 had lymph node metastasis and 27 had no metastasis.The number of dissected,detected on CT,and metastatic nodes were,4241,897,and 801,respectively.The CV obtained from the receiver-operating characteristic was 7.6 mm for the long axis.The sensitivity was 91.4%and the specificity was 47.3%in the prospective phase.The large nodular and diffuse metastases were easy to diagnose becausemetastatic nodes with a large axis often exhibit these forms.CONCLUSION The ability of MDCT to contribute to a nodal diagnosis of advanced gastric cancer was examined prospectively with precise size data from node mapping,using a CV of 7.6 mm for the long axis that was calculated from the retrospectively collected data.The sensitivity was as high as 91%,and would be improved when referring to the enhanced patterns.However,its specificity was as low as 47%,because most of metastatic nodes in gastric cancer being small in size.The small nodular or peripheral type metastatic nodes were often small and considered difficult to diagnose. 展开更多
关键词 Advanced GASTRIC cancer LYMPH node METASTASIS Multi-detector spiral COMPUTED tomography PATHOLOGICAL diagnosis
下载PDF
NON-INVASIVE IMAGING OF CORONARY ARTERY WITH 16-SLICE SPIRAL COMPUTED TOMOGRAPHY 被引量:6
8
作者 Zhu-huaZhang Zheng-yuJin +14 位作者 Dong-jingLi Song-baiLin Shu-yangZhang Ling-yanKong YunWang Lin-huiWang Wen-minZhao Wen-binMou Li-RenZhang Wen-lingZhu ChaoNi HuaRen Hong-quanYu QiMiao QiFang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期174-179,共6页
To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensa... To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD. 展开更多
关键词 ANGIOGRAPHY tomography X-ray computed coronary artery
下载PDF
FINDINGS OF CHEST RADIOGRAPH AND SPIRAL COMPUTED TOMOGRAPHY IN SWYER-JAMES SYNDROME 被引量:1
9
作者 He-shui Shi Fan Yang Ping Han Jin-long Zheng Gan-sheng Feng Yong-hua Liu Zhi-liang Tian Gang Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第1期53-56,共4页
Objective To evaluate the value of X-ray and spiral computed tomography (SCT) in the diagnosis of Swyer-James syndrome (SJS).Methods A total of 28 patients, 12 males and 16 females, were studied retrospectively.Ages r... Objective To evaluate the value of X-ray and spiral computed tomography (SCT) in the diagnosis of Swyer-James syndrome (SJS).Methods A total of 28 patients, 12 males and 16 females, were studied retrospectively.Ages ranged from 11 to 57 years, the mean age was 32 years.All patients underwent inspiratory chest X-ray films, 5 with expiratory chest films and 1 with bronchogram.Furthermore, inspiratory and expiratory SCT scans were performed.The SCT findings were analyzed and compared with X-ray films.Results SCT demonstrated 56 lobes with hyperlucency and diminished vascularity.The size of 51 lobes were smaller and 5 were normal.X-ray films showed that hyperlucency was only in 29 lobes, in which 19 lobes were small-sized and the other 10 lobes normal.There were 56 lobes with air-trapping on expiratory SCT scans, but only 5 lobes with air-trapping on expiratory X-ray films.Bronchogram in 1 case demonstrated bronchiectasis and bronchiolitis obliterans.SCT showed 24 patients with bronchiectasis, 9 patients with tuberculosis, 10 patients with bronchiolitis, and 2 with segmental collapse.Conclusion SCT scan is superior to chest radiography in the diagnosis and differential diagnosis of SJS. 展开更多
关键词 EMPHYSEMA LUNG computed tomography Swyer-James syndrome
下载PDF
Accuracy of linear vs spiral tomography:Alveolar crest to sinus/nasal floor height
10
作者 Mahsa Yoozbashizadeh Seyed Ahmad Fatemitabar +1 位作者 Ehsan Sedighara Arash Nikgoo 《World Journal of Stomatology》 2013年第4期91-96,共6页
AIM:To determine the accuracy of tomography in the linear measurement of alveolar bone at maxillary sinus/nose location.METHODS:Two dry skulls each marked with 10 pairs of guttaperchas placed on buccal and lingual sid... AIM:To determine the accuracy of tomography in the linear measurement of alveolar bone at maxillary sinus/nose location.METHODS:Two dry skulls each marked with 10 pairs of guttaperchas placed on buccal and lingual sides of the maxillary ridge were used in this in vitro study.The distance between the alveolar crest and the sinus/nasal floor was measured on tomographic views,prepared by linear and spiral techniques.The ridges were then sectioned so that each section would include one pair of buccal and lingual guttaperchas.The actual distances directly measured on the sections were compared to those of the equivalent tomographic sections(the magnification co-efficient was applied).Paired t-test was used to statistically analyze the data.RESULTS:The measurement error with the application of linear tomography and spiral tomography wasshown to be 0.455±0.838 mm(P=0.029)and 0.17±0.78 mm(P=0.347),respectively.There was a statistically significant difference between the liner tomography values and actual values(P=0.029).This difference was representative of underestimation.McNamara’s test was used to assess the±1 mm error;73.7%of the linear values and 84.2%of the spiral values were within the±1 mm error limit.Mc Namara’s test did not show any significant differences between the 2methods in this regard(P=0.625).The linear values were significantly different to the actual values(P=0.029)but not to the spiral values(P=0.185).CONCLUSION:Spiral tomography has enough accuracy for the measurement of alveolar ridge height.Although linear tomography somewhat underestimates the actual values it provides satisfactory accuracy. 展开更多
关键词 LINEAR tomography spiral tomography MAXILLARY SINUS Dental implants
下载PDF
Utility of Spiral Computed Tomography in the Study of Dislocation of Cricoarytenoid Joint
11
作者 王志斌 夏黎明 王承缘 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2003年第1期78-80,共3页
The cricoarytenoid relationship presented with spiral computed tomography was demonstrated and the reconstruction of arytenoid dislocation was presented by using multiplanar reconstruction algorithms. Fifteen patients... The cricoarytenoid relationship presented with spiral computed tomography was demonstrated and the reconstruction of arytenoid dislocation was presented by using multiplanar reconstruction algorithms. Fifteen patients with arytenoid dislocation documented by fiberoptic laryngoscopy and strobovideolaryngoscopy and 10 normal persons were displayed by spiral computed tomography (CT). A making design of our own had been used to diagnose arytenoid dislocation on axial CT image. Results showed that dislocation of cricoarytenoid joint was consistently demonstrated on several of the overlapping thin axial reconstructions in each of the 15 patients, in whom asymmetry of the bilateral cricoarytenoid joints was noted on axial images. It was found that on the glottic-fissure level the basal angle on abnormal side was larger in 8 patients than that on the normal side and smaller in 7 patients in patient group, whereas right basal angle was equal to the left in 8 subjects, except 2 in control group. There was statistically significant difference in the number of the equal to two basal angles of glottic fissure between control group and patient group (P<0.025). High-quality sagittal and coronal reconstructive images often were helpful in confirming or clarifying the complex arytenoid orientations. The findings that two-side basal angle was not equal in triangle of glottic fissure can be used as an objective parameter to diagnose arytenoid dislocation. Spiral CT is a useful adjunct in the diagnosis and treatment of dislocation of cricoarytenoid joint. 展开更多
关键词 laryngeal diseases tomography X-ray computed dislocation of cricoarytenoid joint
下载PDF
Tectonic evolution of the Karakoram metamorphic complex(NW Himalayas)reflected in the 3D structures of spiral garnets:Insights from X-ray computed micro-tomography
12
作者 M.Sayab D.Aerden +1 位作者 J.Kuva W.U.Hassan 《Geoscience Frontiers》 SCIE CAS CSCD 2021年第3期528-540,共13页
Spiral garnet porphyroblasts are known to record lengthy periods of deformation and metamorphism by preserving single or multiple FIAs(Foliation Intersection Axis)formed normal to tectonic shortening directions.Thanks... Spiral garnet porphyroblasts are known to record lengthy periods of deformation and metamorphism by preserving single or multiple FIAs(Foliation Intersection Axis)formed normal to tectonic shortening directions.Thanks to technological advances in X-ray computed micro-tomography(XCMT),FIAs can now be readily determined in relatively large samples in contrast to previous methods that require the preparation of a set of radial vertical and horizontal thin sections of samples.XCMT scanning not only alleviates tedious thin section based procedures but also illuminates the complete internal architecture of a rock sample allowing three-dimensional(3D)quantitative shape analysis of an individual porphyroblast as well as precise measurement of FIAs.We applied the technique to a sample from the Hunza Valley in the Karakoram metamorphic complex(KMC),NW Himalayas,containing numerous garnet porphyroblasts with spiral-shaped inclusion trails.The XCMT imaging reveals an E-W trending FIA within the sample,which is consistent with orthogonal N-S collision of the India-Kohistan Island Arc with Asia.Garnet long axes(X_(GT))have variable plunges that define a broad sub-vertical maximum and a small sub-horizontal maximum.The X_(GT) principle maxima lie at N-090 and N-120.Smaller maxima lie at N-020 and N-340.Geometric relationships between X_(GT) axes and FIA orientation in the sample suggest that porphyroblast shapes are controlled by the geometry of the lens-shaped microlithons in which they tend to nucleate and grow.The orientation of inclusion trails and matrix foliations in the sample are correlated with three discrete tectono-metamorphic events that respectively produced andalusite,sillimanite and kyanite in the KMC.Late staurolite growth in the sample reveals how the rocks extruded to the surface via a significant role of roll-on tectonics,which can be correlated with the Central Himalayas. 展开更多
关键词 PORPHYROBLAST Garnet FIA X-ray tomography KARAKORAM HIMALAYAS
下载PDF
128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram-triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral
13
作者 Lu Lin Yi-ning Wang +9 位作者 Ling-yan Kong Zheng-yu Jin Guang-ming Lu Zhao-qi Zhang Jian Cao Shuo Li Lan Song Zhi-wei Wang Kang Zhou Ming Wang 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期195-200,共6页
Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequen- tial scan mo... Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequen- tial scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrilla- tion referred for a second-generation 128-slice DSCT coronary angiography were included in the prospec- tive study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG.~triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel- lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each natient were comDared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean FIR (t= 1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by readerl and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by readerl and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27+0.19 vs. 1.25+0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively ECG-gated spiral scan, prospectively ECG-triggered sequential DSCT coronary angiography provides similarly diagnostically valuable images in patients with atrial fibrillation and significantly reduces radiation dose. 展开更多
关键词 atrial fibrillation computed tomography coronary angiography prospectivelyelectrocardiogram-triggered sequential scan
下载PDF
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
14
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 X-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering X-ray source Monte Carlo simulation
下载PDF
Aflibercept combined with triamcinolone acetonide in the treatment of diabetic macular edema:optical coherence tomography and optical coherence tomography angiography
15
作者 De-Shuang Li Hong-Xia Liao +4 位作者 Chuan-He Zhang Jian-Guo Huang Wei Chen Jing-Lin Zhang Bo Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期670-675,共6页
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone... AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography hyperreflective foci subretinal fluid foveal avascular zone AFLIBERCEPT
下载PDF
Energy spectrum computed tomography multi-parameter imaging in preoperative assessment of vascular and neuroinvasive status in gastric cancer
16
作者 Jing Wang Jian-Cheng Liang +1 位作者 Fa-Te Lin Jun Ma 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2511-2520,共10页
BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent ye... BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent years,energy spectrum computed tomography(CT)multiparameter imaging technology has been gradually applied in clinical practice because of its advantages in tissue contrast and lesion detail display.AIM To explore and analyze the value of multiparameter energy spectrum CT imaging in the preoperative assessment of vascular invasion(LVI)and nerve invasion(PNI)in GC patients.METHODS Data from 62 patients with GC confirmed by pathology and accompanied by energy spectrum CT scanning at our hospital between September 2022 and September 2023,including 46 males and 16 females aged 36-71(57.5±9.1)years,were retrospectively collected.The patients were divided into a positive group(42 patients)and a negative group(20 patients)according to the presence of LVI/PNI.The CT values(CT40 keV,CT70 keV),iodine concentration(IC),and normalized IC(NIC)of lesions in the upper energy spectrum CT images of the arterial phase,venous phase,and delayed phase 40 and 70 keV were measured,and the slopes of the energy spectrum curves[K(40-70)]from 40 to 70 keV were calculated.Arterial Core Tip:To investigate the application value of multiparameter energy spectrum computed tomography(CT)imaging in the preoperative assessment of vascular and nerve infiltration in patients with gastric cancer(GC).The imaging data of GC patients were retrospectively analyzed to evaluate the accuracy and sensitivity of CT for identifying and quantifying vascular and nerve infiltration and for comparison with postoperative pathological results.The purpose of this study was to verify the clinical feasibility and potential advantages of multiparameter energy spectrum CT imaging in guiding preoperative diagnosis and treatment decision-making and to provide a new imaging basis for improving the diagnostic accuracy and prognosis of GC patients. 展开更多
关键词 tomography X-ray computer Energy spectrum computed tomography Gastric cancer Vascular invasion Nerve invasion Cross-sectional study
下载PDF
Computed tomography for prediction of esophageal variceal bleeding
17
作者 Mohammed Elhendawy Ferial Elkalla 《World Journal of Gastrointestinal Endoscopy》 2024年第3期175-177,共3页
This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is ... This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is one of the most common and severe complications related to portal hypertension(PH).Despite marked advances in its management during the last three decades,EVB is still associated with significant morbidity and mortality.The risk of first EVB is related to the severity of both PH and liver disease,and to the size and endoscopic appearance of esophageal varices.Indeed,hepatic venous pressure gradient(HVPG)and esophagogastroduodenoscopy(EGD)are currently recognized as the“gold standard”and the diagnostic reference standard for the prediction of EVB,respectively.However,HVPG is an invasive,expensive,and technically complex procedure,not widely available in clinical practice,whereas EGD is mainly limited by its invasive nature.In this scenario,computed tomography(CT)has been recently proposed as a promising modality for the non-invasive prediction of EVB.While CT serves solely as a diagnostic tool and cannot replace EGD or HVPG for delivering therapeutic and physiological information,it has the potential to enhance the prediction of EVB more effectively when combined with liver disease scores,HVPG,and EGD.However,to date,evidence concerning the role of CT in this setting is still lacking,therefore we aim to summarize and discuss the current evidence concerning the role of CT in predicting the risk of EVB. 展开更多
关键词 Esophageal variceal bleeding Variceal upper gastrointestinal bleeding Portal hypertension Computed tomography Computed tomography angiography
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
18
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report 被引量:2
19
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst Computer tomography MISDIAGNOSIS HEMORRHAGE INFECTION Case report
下载PDF
Glaucoma surgery experiments using digital microscope-integrated optical coherence tomography and OCT-compatible instruments 被引量:1
20
作者 Tianliang Jiang Jinyu Fan +2 位作者 Ning Tang Yi He Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第5期105-113,共9页
There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)... There is a certain failure rate in traditional glaucoma surgery because of the lack of depth information in microscope images.In this work,we present a digital microscope-integrated optical coherence tomography(MIOCT)system and several custom-made OCT-compatible instruments for glaucoma surgery.Sixteen ophthalmologists were asked to perform trabeculectomy and canaloplasty on live porcine eyes using the system and instruments.After surgery,a subjective feedback survey about the user experience was taken.The experiment results showed that our system can help surgeons easily locate important tissue structures during surgery.The custom-made instruments also solved the shadowing problem in OCT imaging.Surgeons preferred to use the system in their future practice. 展开更多
关键词 Microscope-integrated optical coherence tomography OCT-compatible instruments glaucoma surgery TRABECULECTOMY CANALOPLASTY
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部