AIM:To access the agreement of intraocular pressure(IOP)values obtained from biomechanically corrected tonometer[Corvis ST(CST)],non-contact tonometer(NCT),and Goldmann applanation tonometer(GAT)in children with NCT m...AIM:To access the agreement of intraocular pressure(IOP)values obtained from biomechanically corrected tonometer[Corvis ST(CST)],non-contact tonometer(NCT),and Goldmann applanation tonometer(GAT)in children with NCT measured-IOP(NCT-IOP)values of 22 mm Hg or more,and related factors.METHODS:A total of 51 eyes with NCT-IOP≥22 mm Hg in children aged 7 to 14y were examined and IOP was measured by CST,NCT,and GAT.Based on GAT measured IOP(GAT-IOP),ocular hypertension(OHT)group(≥22 mm Hg,24 eyes)and the non-OHT group(<22 mm Hg,27 eyes)were defined.We compared the agreement of the three measurements,i.e.,CST measured IOP(CST-IOP),GAT-IOP,and NCT-IOP,and further analyzed the correlation between the differences in tonometry readings,central corneal thickness(CCT),axial length(AL),optic disc rim volume,and age.RESULTS:Compared with the OHT group,thicker CCT,larger rim volume,and higher differences between NCTIOP and GAT-IOP,were found in the non-OHT group.The differences between CST-IOP and GAT-IOP were lower than the differences between NCT-IOP and GAT-IOP in both groups.The mean differences in CST-IOP and GAT-IOP were 1.26 mm Hg(95%limit of agreement ranged from 0.1 to 2.41 mm Hg,OHT group)and 1.20 mm Hg(95%limit of agreement ranged from-0.5 to 3.00 mm Hg,non-OHT group),and the mean differences in NCT and GAT were 3.90 mm Hg(95%limit of agreement ranged from-0.19 to 9.70 mm Hg,OHT group)and 6.00 mm Hg(95%limit of agreement ranged from 1.50 to 10.50 mm Hg,non-OHT group).The differences between CST-IOP and GAT-IOP were not related to CCT,age,and AL in both groups;while the differences between NCT-IOP and GAT-IOP were related to CCT in the OHT group(r=0.93,P<0.001)and to CCT and AL in the non-OHT group(r=0.66,P<0.001,r=-0.81,P<0.001).CONCLUSION:The accuracy of NCT in the diagnosis of pediatric OHT is low.The agreement of CST-IOP and GATIOP was significantly higher in children with and without OHT than in those with NCT-IOP and GAT-IOP.Therefore,CST can be used as a good alternative for IOP measurement in children.The impacts of CCT and AL on NCT measurement need to be fully considered when managing childhood IOP.展开更多
AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on ...AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values.展开更多
AIM:To develop normative data for meibomian gland dysfunction(MGD)parameters,using non-contact meibography technique of Sirius Costruzione Strumenti Oftalmici(CSO)machine,in an Egyptian population sample.METHODS:Obser...AIM:To develop normative data for meibomian gland dysfunction(MGD)parameters,using non-contact meibography technique of Sirius Costruzione Strumenti Oftalmici(CSO)machine,in an Egyptian population sample.METHODS:Observational,cross-sectional,analytic study,in which 104 Egyptian volunteers were included.Both upper lids were examined,using“Sirius CSO”machine.Each eyelid was given a degree of meibomian gland loss(MGL),which was calculated by the software of the machine.RESULTS:Mean percentage MGL in right upper lid was of 30.9%±12.6%,and that of left upper lid was 32.6%±11.8%.Thirty-four volunteers(32.7%)had first-degree MGL in their right upper lid,and 67.3%had second-degree loss.One volunteer(1%)had zero-degree MGL in left upper lid,28(26.9%)had first-degree loss,and 75(72.1%)had second-degree loss.Degree of MGL in right upper eyelid was not related to age,but degree of MGL in left upper eyelid increased with age.There was statistically significant difference between both genders for degree of MGL in right eye(P=0.036)and in left eye(P=0.027).CONCLUSION:Noncontact meibography is a useful non-invasive tool for diagnosing MGL.MGL is diagnosed in 100%of apparently normal individuals;26.9%-32.7%of which have first-degree MGL,and 67.3%-72.1%have second-degree MGL.展开更多
Deception detection plays a crucial role in criminal investigation.Videos contain a wealth of information regarding apparent and physiological changes in individuals,and thus can serve as an effective means of decepti...Deception detection plays a crucial role in criminal investigation.Videos contain a wealth of information regarding apparent and physiological changes in individuals,and thus can serve as an effective means of deception detection.In this paper,we investigate video-based deception detection considering both apparent visual features such as eye gaze,head pose and facial action unit(AU),and non-contact heart rate detected by remote photoplethysmography(rPPG)technique.Multiple wrapper-based feature selection methods combined with the K-nearest neighbor(KNN)and support vector machine(SVM)classifiers are employed to screen the most effective features for deception detection.We evaluate the performance of the proposed method on both a self-collected physiological-assisted visual deception detection(PV3D)dataset and a public bag-oflies(BOL)dataset.Experimental results demonstrate that the SVM classifier with symbiotic organisms search(SOS)feature selection yields the best overall performance,with an area under the curve(AUC)of 83.27%and accuracy(ACC)of 83.33%for PV3D,and an AUC of 71.18%and ACC of 70.33%for BOL.This demonstrates the stability and effectiveness of the proposed method in video-based deception detection tasks.展开更多
AIM: To evaluate the intraocular pressure(IOP)measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry(GAT). METHODS: Fifty patients using contact lens were include...AIM: To evaluate the intraocular pressure(IOP)measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry(GAT). METHODS: Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens(RTCL,RT respectively) and by GAT, as well as their central corneal thickness(CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis.RESULTS: Mean IOP values measured by RTCL, RT and GAT were 15.68 ±3.7, 14.50 ±3.4 and 14.16 ±2.8(P 【0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT(P 【0.001), while there was no difference between the measurements by GAT and RT(P =0.629). There was a good level of positive correlation between GAT and RTCL as well as RT(r =0.786 P 【0.001, r =0.833 P 【0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT(P =0.329), RTCL and GAT(P =0.07) as well as RT and GAT(P =0.189) in linear regression model.CONCLUSION: The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.展开更多
Non-contact sensing can be a rapid and convenient alternative for determining structure response compared to conventional instrumentation.Computer vision has been broadly implemented to enable accurate non-contact dyn...Non-contact sensing can be a rapid and convenient alternative for determining structure response compared to conventional instrumentation.Computer vision has been broadly implemented to enable accurate non-contact dynamic response measurements for structures.This study has analyzed the effect of non-contact sensors,including type,frame rate,and data collection platform,on the performance of a novel motion detection technique.Video recordings of a cantilever column were collected using a high-speed camera mounted on a tripod and an unmanned aerial system(UAS)equipped with visual and thermal sensors.The test specimen was subjected to an initial deformation and released.Specimen acceleration data were collected using an accelerometer installed on the cantilever end.The displacement from each non-contact sensor and the acceleration from the contact sensor were analyzed to measure the specimen′s natural frequency and damping ratio.The specimen′s first fundamental frequency and damping ratio results were validated by analyzing acceleration data from the top of the specimen and a finite element model.展开更多
Noncontact slit lamp examination of the ocular fundus has been classically done using high power convex lenses like+90D,+78D,and+60D.A real and inverted image of the fundus is formed in between the high power convex l...Noncontact slit lamp examination of the ocular fundus has been classically done using high power convex lenses like+90D,+78D,and+60D.A real and inverted image of the fundus is formed in between the high power convex lens and the slit lamp.The+20D lens is commonly used for binocular indirect ophthalmoscopy.The authors use this+20D lens展开更多
At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this ...At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.展开更多
A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, ...A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic...展开更多
The severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which caused the coronavirus disease 2019(COVID-19)pandemic,has affected more than 400 million people worldwide.With the recent rise of new Delta and Omi...The severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which caused the coronavirus disease 2019(COVID-19)pandemic,has affected more than 400 million people worldwide.With the recent rise of new Delta and Omicron variants,the efficacy of the vaccines has become an important question.The goal of various studies has been to limit the spread of the virus by utilizing wireless sensing technologies to prevent human-to-human interactions,particularly for healthcare workers.In this paper,we discuss the current literature on invasive/contact and non-invasive/noncontact technologies(including Wi-Fi,radar,and software-defined radio)that have been effectively used to detect,diagnose,and monitor human activities and COVID-19 related symptoms,such as irregular respiration.In addition,we focused on cutting-edge machine learning algorithms(such as generative adversarial networks,random forest,multilayer perceptron,support vector machine,extremely randomized trees,and k-nearest neighbors)and their essential role in intelligent healthcare systems.Furthermore,this study highlights the limitations related to non-invasive techniques and prospective research directions.展开更多
A novel non-contact spacecraft architecture with the extended stochastic state observer for disturbance rejection control of the gravity satellite is proposed.First,the precise linear driving non-contact voice-coil ac...A novel non-contact spacecraft architecture with the extended stochastic state observer for disturbance rejection control of the gravity satellite is proposed.First,the precise linear driving non-contact voice-coil actuators are used to separate the whole spacecraft into the non-contact payload module and the service module,and to build an ideal loop with precise dynamics for disturbance rejection control of the payload module.Second,an extended stochastic state observer is enveloped to construct the overall nonlinear external terms and the internal coupled terms of the payload module,enabling the controller design of the payload module turned into the linear form with simple bandwidth-parameterization tuning in the frequency domain.As a result,the disturbance rejection control of the payload module can be explicitly achieved in a timely manner without complicated tuning in actual implementation.Finally,an extensive numerical simulation is conducted to validate the feasibility and effectiveness of the proposed approach.展开更多
This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In ...This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In addition, we tested the ability of the proposed prototype system to measure the respiratory and heart rates of the elderly in a nursing home and discussed the systems effectiveness and problems by examining results of real-time monitoring. The prototype system consisted of two 24-GHz microwave radar antennas and an analysis system. The antennas were positioned below a mattress to monitor motion on the body surface for measuring cardiac and respiratory rates from the dorsal side of the subjects (23.3 ± 1.2 years) who would be lying on the mattress. The heart rates determined by the prototype system correlated significantly with those measured by electrocardiography (r = 0.92). Similarly, the respiratory rates determined by the prototype correlated with those obtained from respiration curves (r = 0.94). Next, we investigated the effectiveness of the prototype system with 7 elderly patients (93.3 ± 10.56 years) at a nursing home. The proposed system appears to be a promising tool for monitoring the vital signs of the elderly in a way that alleviates the need to attach electrodes overnight to confirm patient safety.展开更多
Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching...Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching explosives are established, and numerical simulation of air-blast wave propagation by non-contact explosion counter-terrorist door breaching explosive are achieved. The research results show that the overpressure behind the target door is attenuated deeply through the burglary resistant safety door, and the propagation of blast wave and the damage effect under differ- ent space conditions are obviously different.展开更多
Vortex levitation attains non-contact handling by injecting air through a tangential nozzle into a cylindrical cup generating the swirling flow. The precessing of the swirling flow causes pressure fluctuation. This ph...Vortex levitation attains non-contact handling by injecting air through a tangential nozzle into a cylindrical cup generating the swirling flow. The precessing of the swirling flow causes pressure fluctuation. This phenomenon becomes apparent as the gap between the cup and workpiece increases, which significantly disturbs the stability of conveyance. In this paper, suppression of pressure fluctuation by a cylindrical column that stabilizes the vortex levitation is described and its mechanism is mentioned. According to the experimental set up, the pressure was measured at the center of the workpiece and the wall of the cup;velocity field under the work piece was visualized by PIV. The result suggested that the larger diameter column denoted the effect on suppression of the fluctuation because the precessing of the swirling flow became stable. On the other hand, variation of the column thickness had insignificant effect on suppressing the fluctuation, but sucking force became weakened since the swirling velocity decreased.展开更多
Failures are very common during the online real-time monitoring of large quantities of complex liquids in industrial processes, and can result in excessive resource consumption and pollution. In this study, we introdu...Failures are very common during the online real-time monitoring of large quantities of complex liquids in industrial processes, and can result in excessive resource consumption and pollution. In this study, we introduce a monitoring method capable of non-contact original-state online real-time monitoring for strongly coated, high-salinity, and multi-component liquids. The principle of the method is to establish the relationship among the concentration of the target substance in the liquid (C), the color space coor- dinates of the target substance at different concentrations (L*, a*, b*), and the maximum absorption wave- length (λmax); subsequently, the optimum wavelength λT of the liquid is determined by a high-precision scanning-type monitoring system that is used to detect the instantaneous concentration of the target substance in the flowing liquid. Unlike traditional monitoring methods and existing online monitoring methods, the proposed method does not require any pretreatment of the samples (i.e., filtration, dilution, oxidation/reduction, addition of chromogenic agent, constant volume, etc.), and it is capable of original- state online real-time monitoring. This method is employed at a large electrolytic manganese plant to monitor the Fe3. concentration in the colloidal process of the plant's aging liquid (where the concentra- tions of Fe3+, Mn2+, and (NH4)2SO4 are 0.5-18 mg.L 1, 35-39 g.L 1, and 90-110 g.L 1, respectively). The relative error of this monitoring method compared with an off-line laboratory monitoring is less than 2%.展开更多
An optimization design for the cylindrical non-contact piezoelectric actuator is presented after analyzing the acoustic radiation pressure and acoustic viscous force.By adding the specific microstructure on the rotor ...An optimization design for the cylindrical non-contact piezoelectric actuator is presented after analyzing the acoustic radiation pressure and acoustic viscous force.By adding the specific microstructure on the rotor to alter the near-field sound effect and maximize the use of high intensity acoustic field induced by the stator to drive the rotor,the rotor speed is increased.The finite element analysis of the acoustic field induced by a variety of rotors with different structures is conducted,A prototype is manufactured,the speed-test system for the actuator is built,and the driving characteristics are measured.The results suggest that the rotation speed of the rotor can reach 4 167r/min,which demonstrates that the driving characteristics of cylindrical non-contact piezoelectric actuator are successfully improved using the optimization method proposed.展开更多
In this contribution, we present an all-optical quantitative framework for bioluminescence tomography with non-contact measurement. The framework is comprised of four indispensable steps: extraction of the geometrica...In this contribution, we present an all-optical quantitative framework for bioluminescence tomography with non-contact measurement. The framework is comprised of four indispensable steps: extraction of the geometrical structures of the subject, light flux reconstruction on arbitrary surface, calibration and quantification of the surface light flux and internal bioluminescence reconstruction. In particular, the geometrical structures are retrieved using a completely optical method and captured under identical viewing conditions with the bioluminescent images. As a result, the proposed framework avoids the utilization of computed tomography or magnetic resonance imaging to provide the geometrical structures. On the basis of experimental measurements, we evaluate the performance of the proposed all-optical quantitative framework using a mouse shaped phantom. Preliminary result reveals the potential and feasibility of the proposed framework for bioluminescence tomography.展开更多
A novel hybrid instrument of contact and non-contact measurement with large range is developed, and both measurement systems are based on a Linnik interference microscope and on white-light interference measuring tech...A novel hybrid instrument of contact and non-contact measurement with large range is developed, and both measurement systems are based on a Linnik interference microscope and on white-light interference measuring techniques. The ambiguity presented in conventional monochromatic interferometers is not present in the contact and non-contact measurement, and they have a virtually unlimited unambiguous range. For the contact measurement, the vertical measuring range is ±5 mm with a resolution of 1 nm and the horizontal measuring range is ±25 mm in x-range and y-range with a resolution of 1.25 μm; for the non-contact measurement, the vertical measuring range is ~5 mm with a resolution of 1 nm and the horizontal resolution better than 0.5 urn.展开更多
With the continuous development of industrial technology, the weak current plays an increasingly important role in all fields of life. In order to facilitate the user to carry, the study of contactless weak current me...With the continuous development of industrial technology, the weak current plays an increasingly important role in all fields of life. In order to facilitate the user to carry, the study of contactless weak current measurement technology is also emerging. This article’s design idea is based on two-dimensional reluctance sensor device built non-contact weak current detection system. The system uses the reluctance sensor HMC1002 to collect the current signal and the temperature sensor DS18B20 to compensate the temperature. The signals collected by the reluctance sensor and the temperature sensor are extremely weak. After being amplified by the amplifying circuit, the signal is conducive to subsequent detection and processing. Filter circuit can filter out interference signals to achieve the goal of improving accuracy. After the corresponding algorithm of the microcontroller will convert the signal voltage, easy to read and store, thus designing a non-contact current measurement capable of detecting weak currents and achieving higher accuracy.展开更多
基金Supported by Medical Science Research Project of Hebei Province in 2023(No.20231818).
文摘AIM:To access the agreement of intraocular pressure(IOP)values obtained from biomechanically corrected tonometer[Corvis ST(CST)],non-contact tonometer(NCT),and Goldmann applanation tonometer(GAT)in children with NCT measured-IOP(NCT-IOP)values of 22 mm Hg or more,and related factors.METHODS:A total of 51 eyes with NCT-IOP≥22 mm Hg in children aged 7 to 14y were examined and IOP was measured by CST,NCT,and GAT.Based on GAT measured IOP(GAT-IOP),ocular hypertension(OHT)group(≥22 mm Hg,24 eyes)and the non-OHT group(<22 mm Hg,27 eyes)were defined.We compared the agreement of the three measurements,i.e.,CST measured IOP(CST-IOP),GAT-IOP,and NCT-IOP,and further analyzed the correlation between the differences in tonometry readings,central corneal thickness(CCT),axial length(AL),optic disc rim volume,and age.RESULTS:Compared with the OHT group,thicker CCT,larger rim volume,and higher differences between NCTIOP and GAT-IOP,were found in the non-OHT group.The differences between CST-IOP and GAT-IOP were lower than the differences between NCT-IOP and GAT-IOP in both groups.The mean differences in CST-IOP and GAT-IOP were 1.26 mm Hg(95%limit of agreement ranged from 0.1 to 2.41 mm Hg,OHT group)and 1.20 mm Hg(95%limit of agreement ranged from-0.5 to 3.00 mm Hg,non-OHT group),and the mean differences in NCT and GAT were 3.90 mm Hg(95%limit of agreement ranged from-0.19 to 9.70 mm Hg,OHT group)and 6.00 mm Hg(95%limit of agreement ranged from 1.50 to 10.50 mm Hg,non-OHT group).The differences between CST-IOP and GAT-IOP were not related to CCT,age,and AL in both groups;while the differences between NCT-IOP and GAT-IOP were related to CCT in the OHT group(r=0.93,P<0.001)and to CCT and AL in the non-OHT group(r=0.66,P<0.001,r=-0.81,P<0.001).CONCLUSION:The accuracy of NCT in the diagnosis of pediatric OHT is low.The agreement of CST-IOP and GATIOP was significantly higher in children with and without OHT than in those with NCT-IOP and GAT-IOP.Therefore,CST can be used as a good alternative for IOP measurement in children.The impacts of CCT and AL on NCT measurement need to be fully considered when managing childhood IOP.
文摘AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values.
文摘AIM:To develop normative data for meibomian gland dysfunction(MGD)parameters,using non-contact meibography technique of Sirius Costruzione Strumenti Oftalmici(CSO)machine,in an Egyptian population sample.METHODS:Observational,cross-sectional,analytic study,in which 104 Egyptian volunteers were included.Both upper lids were examined,using“Sirius CSO”machine.Each eyelid was given a degree of meibomian gland loss(MGL),which was calculated by the software of the machine.RESULTS:Mean percentage MGL in right upper lid was of 30.9%±12.6%,and that of left upper lid was 32.6%±11.8%.Thirty-four volunteers(32.7%)had first-degree MGL in their right upper lid,and 67.3%had second-degree loss.One volunteer(1%)had zero-degree MGL in left upper lid,28(26.9%)had first-degree loss,and 75(72.1%)had second-degree loss.Degree of MGL in right upper eyelid was not related to age,but degree of MGL in left upper eyelid increased with age.There was statistically significant difference between both genders for degree of MGL in right eye(P=0.036)and in left eye(P=0.027).CONCLUSION:Noncontact meibography is a useful non-invasive tool for diagnosing MGL.MGL is diagnosed in 100%of apparently normal individuals;26.9%-32.7%of which have first-degree MGL,and 67.3%-72.1%have second-degree MGL.
基金National Natural Science Foundation of China(No.62271186)Anhui Key Project of Research and Development Plan(No.202104d07020005)。
文摘Deception detection plays a crucial role in criminal investigation.Videos contain a wealth of information regarding apparent and physiological changes in individuals,and thus can serve as an effective means of deception detection.In this paper,we investigate video-based deception detection considering both apparent visual features such as eye gaze,head pose and facial action unit(AU),and non-contact heart rate detected by remote photoplethysmography(rPPG)technique.Multiple wrapper-based feature selection methods combined with the K-nearest neighbor(KNN)and support vector machine(SVM)classifiers are employed to screen the most effective features for deception detection.We evaluate the performance of the proposed method on both a self-collected physiological-assisted visual deception detection(PV3D)dataset and a public bag-oflies(BOL)dataset.Experimental results demonstrate that the SVM classifier with symbiotic organisms search(SOS)feature selection yields the best overall performance,with an area under the curve(AUC)of 83.27%and accuracy(ACC)of 83.33%for PV3D,and an AUC of 71.18%and ACC of 70.33%for BOL.This demonstrates the stability and effectiveness of the proposed method in video-based deception detection tasks.
文摘AIM: To evaluate the intraocular pressure(IOP)measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry(GAT). METHODS: Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens(RTCL,RT respectively) and by GAT, as well as their central corneal thickness(CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis.RESULTS: Mean IOP values measured by RTCL, RT and GAT were 15.68 ±3.7, 14.50 ±3.4 and 14.16 ±2.8(P 【0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT(P 【0.001), while there was no difference between the measurements by GAT and RT(P =0.629). There was a good level of positive correlation between GAT and RTCL as well as RT(r =0.786 P 【0.001, r =0.833 P 【0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT(P =0.329), RTCL and GAT(P =0.07) as well as RT and GAT(P =0.189) in linear regression model.CONCLUSION: The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population.
文摘Non-contact sensing can be a rapid and convenient alternative for determining structure response compared to conventional instrumentation.Computer vision has been broadly implemented to enable accurate non-contact dynamic response measurements for structures.This study has analyzed the effect of non-contact sensors,including type,frame rate,and data collection platform,on the performance of a novel motion detection technique.Video recordings of a cantilever column were collected using a high-speed camera mounted on a tripod and an unmanned aerial system(UAS)equipped with visual and thermal sensors.The test specimen was subjected to an initial deformation and released.Specimen acceleration data were collected using an accelerometer installed on the cantilever end.The displacement from each non-contact sensor and the acceleration from the contact sensor were analyzed to measure the specimen′s natural frequency and damping ratio.The specimen′s first fundamental frequency and damping ratio results were validated by analyzing acceleration data from the top of the specimen and a finite element model.
文摘Noncontact slit lamp examination of the ocular fundus has been classically done using high power convex lenses like+90D,+78D,and+60D.A real and inverted image of the fundus is formed in between the high power convex lens and the slit lamp.The+20D lens is commonly used for binocular indirect ophthalmoscopy.The authors use this+20D lens
文摘At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.
文摘A precise aperture measuring system of small deep holes with capacitance sensors is presented. Based on the working principle of non-contact capacitance sensors, influence of the edge effect of gauge head is studied, and one capacitance sensor for measuring the aperture of the small blind holes or through holes is introduced. The system is composed of one positioning device, one aperture measuring capacitance sensor, one measuring circuit, and software. This system employs visual CCD and two-dimensional mic...
文摘The severe acute respiratory syndrome coronavirus 2(SARS-CoV-2),which caused the coronavirus disease 2019(COVID-19)pandemic,has affected more than 400 million people worldwide.With the recent rise of new Delta and Omicron variants,the efficacy of the vaccines has become an important question.The goal of various studies has been to limit the spread of the virus by utilizing wireless sensing technologies to prevent human-to-human interactions,particularly for healthcare workers.In this paper,we discuss the current literature on invasive/contact and non-invasive/noncontact technologies(including Wi-Fi,radar,and software-defined radio)that have been effectively used to detect,diagnose,and monitor human activities and COVID-19 related symptoms,such as irregular respiration.In addition,we focused on cutting-edge machine learning algorithms(such as generative adversarial networks,random forest,multilayer perceptron,support vector machine,extremely randomized trees,and k-nearest neighbors)and their essential role in intelligent healthcare systems.Furthermore,this study highlights the limitations related to non-invasive techniques and prospective research directions.
基金supported by the National Natural Science Foundation of China(5170532751805329)+1 种基金Fundamental Research Funds for the Central Universities of China(NS2020065)the Natural Science Foundation of Shanghai(19ZR1453300).
文摘A novel non-contact spacecraft architecture with the extended stochastic state observer for disturbance rejection control of the gravity satellite is proposed.First,the precise linear driving non-contact voice-coil actuators are used to separate the whole spacecraft into the non-contact payload module and the service module,and to build an ideal loop with precise dynamics for disturbance rejection control of the payload module.Second,an extended stochastic state observer is enveloped to construct the overall nonlinear external terms and the internal coupled terms of the payload module,enabling the controller design of the payload module turned into the linear form with simple bandwidth-parameterization tuning in the frequency domain.As a result,the disturbance rejection control of the payload module can be explicitly achieved in a timely manner without complicated tuning in actual implementation.Finally,an extensive numerical simulation is conducted to validate the feasibility and effectiveness of the proposed approach.
文摘This study aimed to produce a prototype system for non-contact vital sign monitoring of the elderly using microwave radar with the intention of reducing the burdens on monitored individuals and nursing caregivers. In addition, we tested the ability of the proposed prototype system to measure the respiratory and heart rates of the elderly in a nursing home and discussed the systems effectiveness and problems by examining results of real-time monitoring. The prototype system consisted of two 24-GHz microwave radar antennas and an analysis system. The antennas were positioned below a mattress to monitor motion on the body surface for measuring cardiac and respiratory rates from the dorsal side of the subjects (23.3 ± 1.2 years) who would be lying on the mattress. The heart rates determined by the prototype system correlated significantly with those measured by electrocardiography (r = 0.92). Similarly, the respiratory rates determined by the prototype correlated with those obtained from respiration curves (r = 0.94). Next, we investigated the effectiveness of the prototype system with 7 elderly patients (93.3 ± 10.56 years) at a nursing home. The proposed system appears to be a promising tool for monitoring the vital signs of the elderly in a way that alleviates the need to attach electrodes overnight to confirm patient safety.
基金Supported by Defense Industrial Technology Development Program(B2220110013)
文摘Aiming at the estimation of personal injury attached by counter-terrorist door breaching explosive blast wave, according to the actual scene, four typical application space models of count- er-terrorist door breaching explosives are established, and numerical simulation of air-blast wave propagation by non-contact explosion counter-terrorist door breaching explosive are achieved. The research results show that the overpressure behind the target door is attenuated deeply through the burglary resistant safety door, and the propagation of blast wave and the damage effect under differ- ent space conditions are obviously different.
文摘Vortex levitation attains non-contact handling by injecting air through a tangential nozzle into a cylindrical cup generating the swirling flow. The precessing of the swirling flow causes pressure fluctuation. This phenomenon becomes apparent as the gap between the cup and workpiece increases, which significantly disturbs the stability of conveyance. In this paper, suppression of pressure fluctuation by a cylindrical column that stabilizes the vortex levitation is described and its mechanism is mentioned. According to the experimental set up, the pressure was measured at the center of the workpiece and the wall of the cup;velocity field under the work piece was visualized by PIV. The result suggested that the larger diameter column denoted the effect on suppression of the fluctuation because the precessing of the swirling flow became stable. On the other hand, variation of the column thickness had insignificant effect on suppressing the fluctuation, but sucking force became weakened since the swirling velocity decreased.
文摘Failures are very common during the online real-time monitoring of large quantities of complex liquids in industrial processes, and can result in excessive resource consumption and pollution. In this study, we introduce a monitoring method capable of non-contact original-state online real-time monitoring for strongly coated, high-salinity, and multi-component liquids. The principle of the method is to establish the relationship among the concentration of the target substance in the liquid (C), the color space coor- dinates of the target substance at different concentrations (L*, a*, b*), and the maximum absorption wave- length (λmax); subsequently, the optimum wavelength λT of the liquid is determined by a high-precision scanning-type monitoring system that is used to detect the instantaneous concentration of the target substance in the flowing liquid. Unlike traditional monitoring methods and existing online monitoring methods, the proposed method does not require any pretreatment of the samples (i.e., filtration, dilution, oxidation/reduction, addition of chromogenic agent, constant volume, etc.), and it is capable of original- state online real-time monitoring. This method is employed at a large electrolytic manganese plant to monitor the Fe3. concentration in the colloidal process of the plant's aging liquid (where the concentra- tions of Fe3+, Mn2+, and (NH4)2SO4 are 0.5-18 mg.L 1, 35-39 g.L 1, and 90-110 g.L 1, respectively). The relative error of this monitoring method compared with an off-line laboratory monitoring is less than 2%.
基金supported by the National Basic Research Program of China(″973″Program)(No.2015CB057500)the National Natural Science Foundation of China(No.11174149)+1 种基金the Fundamental Research Funds for the Central Universitie(No.NJ20140024)State Key Laboratory of Mechanics and Control of Mechanical Structures Research Fund(No.MCMS-0312G02)
文摘An optimization design for the cylindrical non-contact piezoelectric actuator is presented after analyzing the acoustic radiation pressure and acoustic viscous force.By adding the specific microstructure on the rotor to alter the near-field sound effect and maximize the use of high intensity acoustic field induced by the stator to drive the rotor,the rotor speed is increased.The finite element analysis of the acoustic field induced by a variety of rotors with different structures is conducted,A prototype is manufactured,the speed-test system for the actuator is built,and the driving characteristics are measured.The results suggest that the rotation speed of the rotor can reach 4 167r/min,which demonstrates that the driving characteristics of cylindrical non-contact piezoelectric actuator are successfully improved using the optimization method proposed.
基金supported by National Basic Research Program of China (973 Program) (No.2011CB707702)National Natural Science Foundation of China (No.81090272, No.81000632, and No.30900334)+1 种基金Shaanxi Provincial Natural Science Foundation Research Project (No.2009JQ8018)Fundamental Research Funds for the Central Universities
文摘In this contribution, we present an all-optical quantitative framework for bioluminescence tomography with non-contact measurement. The framework is comprised of four indispensable steps: extraction of the geometrical structures of the subject, light flux reconstruction on arbitrary surface, calibration and quantification of the surface light flux and internal bioluminescence reconstruction. In particular, the geometrical structures are retrieved using a completely optical method and captured under identical viewing conditions with the bioluminescent images. As a result, the proposed framework avoids the utilization of computed tomography or magnetic resonance imaging to provide the geometrical structures. On the basis of experimental measurements, we evaluate the performance of the proposed all-optical quantitative framework using a mouse shaped phantom. Preliminary result reveals the potential and feasibility of the proposed framework for bioluminescence tomography.
基金Supported by the National Natural Science Foundation of China (50605018)
文摘A novel hybrid instrument of contact and non-contact measurement with large range is developed, and both measurement systems are based on a Linnik interference microscope and on white-light interference measuring techniques. The ambiguity presented in conventional monochromatic interferometers is not present in the contact and non-contact measurement, and they have a virtually unlimited unambiguous range. For the contact measurement, the vertical measuring range is ±5 mm with a resolution of 1 nm and the horizontal measuring range is ±25 mm in x-range and y-range with a resolution of 1.25 μm; for the non-contact measurement, the vertical measuring range is ~5 mm with a resolution of 1 nm and the horizontal resolution better than 0.5 urn.
文摘With the continuous development of industrial technology, the weak current plays an increasingly important role in all fields of life. In order to facilitate the user to carry, the study of contactless weak current measurement technology is also emerging. This article’s design idea is based on two-dimensional reluctance sensor device built non-contact weak current detection system. The system uses the reluctance sensor HMC1002 to collect the current signal and the temperature sensor DS18B20 to compensate the temperature. The signals collected by the reluctance sensor and the temperature sensor are extremely weak. After being amplified by the amplifying circuit, the signal is conducive to subsequent detection and processing. Filter circuit can filter out interference signals to achieve the goal of improving accuracy. After the corresponding algorithm of the microcontroller will convert the signal voltage, easy to read and store, thus designing a non-contact current measurement capable of detecting weak currents and achieving higher accuracy.