AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed inc...AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change.展开更多
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL...AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.展开更多
AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patient...AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patients with astigmatism who came for TSC fitting and alignment from November 2022 to January 2023 were included.According to the difference in astigmatism,patients were divided into groups A(cylinder degree:-0.75 to-0.50 D),B(cylinder degree:-1.75 to-1.00 D)and C(cylinder degree≤-2.00 D),and followed up on the day of wear,1wk,1 and 3mo,mainly to observe visual acuity,refraction,lens fit,visual quality and comfort at 1wk after wear.The visual acuity success rate and the overall success rate of the fitting were evaluation indicators(taking into account the four dimensions of visual acuity,fitting,quality of vision and comfort).The visual acuity success rate was calculated by taking“corrected visual acuity with contact lenses is no less than 1 line or better than best spectacle-corrected visual acuity”(i.e.corrected visual acuity with contact lenses is 1 line below,equal to,one line above or more than best spectaclecorrected visual acuity)as the criterion for visual success,and the the overall success rate of the fitting was calculated by using the comprehensive indicators(visual acuity,fit,visual quality,comfort)to meet certain conditions as the judgment criteria for successful fitting.RESULTS:After 1wk of wearing TSC,the visual acuity success rates of patients were 100%(207/207),98.58%(139/141)and 97.22%(35/36)in the three groups,respectively,with residual cylinder closed to 0.The acceptability of the lens fitting was over 95%;the incidence of adverse visual symptoms was within 10%and the comfort acceptability was over 97%.The overall success rate of fitting for patients with high,medium and low astigmatism was 93.72%(194/207),90.78%(128/141)and 88.89%(32/36),respectively.CONCLUSION:TSC(model:G&G POP·CT)are effective in correcting astigmatism in patients with different degrees of astigmatism.展开更多
文摘AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change.
文摘AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months.
基金Supported by Key R&D Plan of Shaanxi Province:Key Industrial Innovation Chain(Cluster)-Social Development Field(No.2022ZDLSF03-10).
文摘AIM:To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses(TSC).METHODS:It was a real-world study with prospective and single-arm design.A total of 384 patients with astigmatism who came for TSC fitting and alignment from November 2022 to January 2023 were included.According to the difference in astigmatism,patients were divided into groups A(cylinder degree:-0.75 to-0.50 D),B(cylinder degree:-1.75 to-1.00 D)and C(cylinder degree≤-2.00 D),and followed up on the day of wear,1wk,1 and 3mo,mainly to observe visual acuity,refraction,lens fit,visual quality and comfort at 1wk after wear.The visual acuity success rate and the overall success rate of the fitting were evaluation indicators(taking into account the four dimensions of visual acuity,fitting,quality of vision and comfort).The visual acuity success rate was calculated by taking“corrected visual acuity with contact lenses is no less than 1 line or better than best spectacle-corrected visual acuity”(i.e.corrected visual acuity with contact lenses is 1 line below,equal to,one line above or more than best spectaclecorrected visual acuity)as the criterion for visual success,and the the overall success rate of the fitting was calculated by using the comprehensive indicators(visual acuity,fit,visual quality,comfort)to meet certain conditions as the judgment criteria for successful fitting.RESULTS:After 1wk of wearing TSC,the visual acuity success rates of patients were 100%(207/207),98.58%(139/141)and 97.22%(35/36)in the three groups,respectively,with residual cylinder closed to 0.The acceptability of the lens fitting was over 95%;the incidence of adverse visual symptoms was within 10%and the comfort acceptability was over 97%.The overall success rate of fitting for patients with high,medium and low astigmatism was 93.72%(194/207),90.78%(128/141)and 88.89%(32/36),respectively.CONCLUSION:TSC(model:G&G POP·CT)are effective in correcting astigmatism in patients with different degrees of astigmatism.