Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special...Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special advantages among them such as more different output voltage levels using the same number of components and higher power quality.In this paper,a 27-level inverter switching algorithm considering total harmonic distortion(THD)minimization is investigated.Switching angles of the inverter switches are achieved by minimizing a THD-based objective function.In order to minimize the THD-based objective function,the hyper-spherical search(HSS)algorithm,as a novel optimization algorithm,is improved and the results of improved HSS(IHSS)are compared with HSS algorithm and other five evolutionary algorithms to show the advantages of IHSS algorithm.展开更多
This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inv...This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inverter has the ability to generate nearly sinusoidal waves.This sinusoidal wave can be further improved by increasing the level of output voltage or with the help of filter design,and this manuscript presents single-phase Multi cell Multi-Level Inverter(MLI).It has been considered for reducing component count to get a higher number of output voltage levels and lower Total harmonics distortion profile.It comprises with four symmetric DC input voltage and 10 IGBT switches to produces stepped output of 9 level,and when deploy asymmetric Dc voltage source the same circuit will produce 31 level output with some changes in firing scheme,moreover this circuit is the family of cascaded hybrid bridge inverter so this circuit covered advantage of CHB MLI,This circuit uses lower no.of switch as compared to existing conventional MLIs such as FC-MLI,CHB-MLI,NPC-MLI,This paper also provides one of most pertinent controls and modulation mechanisms for a MLI using a hybrid reference/carrier-oriented sinusoidal PWM mechanism.At last,simulated outcomes are to validate the performance of both architectures in MLI structure as well as verify the concept.展开更多
In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distributio...In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB.展开更多
Power quality challenges have generated a lot of disputes between utilities,customers,network operators,and equipment manufacturers around the world as regards the share of responsibility for power quality solutions,t...Power quality challenges have generated a lot of disputes between utilities,customers,network operators,and equipment manufacturers around the world as regards the share of responsibility for power quality solutions,this results in different levels of financial and technical losses for both the network operators and the customers.One of the major consequences of the operation of heavy-duty factories globally is the corruption of power quality at the point of common coupling(PCC).In order to quantify the harmonics contribution at the PCC by industrial consumers,this paper presents three-phase total harmonics distortion of current(THDi)prediction model at the PCC.The proposed artificial neural network(ANN)models use a multilayer perceptron neural network(MLPN)to predict three-phase total harmonic distortion.The input parameter used in the models is easily measured with basic power meters.The model was trained with input parameters captured at 33 kV and 132 kV voltage levels using power quality meters at five(5)different steel manufacturing plants.Eight(8)different models were designed,trained,validated,and tested with different combinations of input parameters,number of hidden layers,and number of neurons in the hidden layer.The results show that the model with two hidden layers which uses four major power parameters(Current,apparent power,reactive and active power)as input parameters in the training model had the best performance with a 95.5%coefficient of correlation between the measured THDi and the predicted THDi.展开更多
Based on theoretical inference and computer simulation,the relationship between the harmonics and the parameters of SPWM was widely investigated.The rule of the total harmonic distortion and the harmonic spectrum dist...Based on theoretical inference and computer simulation,the relationship between the harmonics and the parameters of SPWM was widely investigated.The rule of the total harmonic distortion and the harmonic spectrum distribution has been obtained.In order to decrease the harmonics,the selecting methods for optimal magnitude of the amplitude modularity and the frequency modularity are also given.展开更多
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t...Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.展开更多
Like others countries of the world, in Niger also, we are witnessing an increasing use of non-linear electric loads in the domestic, hospital and industrial sectors. However, these loads degrade the shape of the elect...Like others countries of the world, in Niger also, we are witnessing an increasing use of non-linear electric loads in the domestic, hospital and industrial sectors. However, these loads degrade the shape of the electrical signal and cause disastrous effects to the equipment of the distribution system and the devices which are connected to the network. This article highlights the presence of electric harmonics in the distribution network in Niamey city. In order to do this, measurements were taken at the secondary level of the substations using an energy quality analyze r (FLUKE 1735). By using this measuring instrument, we quantified the voltage and current Total Harmonic Distortion (THD) in the three substations. The results obtained show that, although the statutable rates set by the standards are not exceeded for phase conductors, the neutral contains a very critical percentage of distortion on the residential and hospital substations. Moreover, this assessment made it possible to observe the variation of harmonics in the presence of voltage drops.展开更多
In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and v...In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation.展开更多
The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural con...The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural contamination.This paper deals with the renewable energy based micro-grid as it is regarded as the apt solution for integrating the RER with the electrical frameworks.As thefixed droop coefficients in conventional droop control approaches have caused various limitations like low power-sharing and sudden drops of grid voltage in the Direct Current(DC)side,the Harmonized Membership Fuzzy Logic(MFL)droop control is employed in this present study.This proposed droop control for the hybrid PV-wind-battery system with MFL assists in achieving proper power-sharing and minimizing Total Harmonic Distortion(THD)in the emer-gency micro-grid.It eradicates the deviations in voltage and frequency with itsflexible and robust operation.The THD is reduced and attains the value of 3.1%compared to the traditional droop control.The simulation results of harmo-nized MFL droop control are analogized with the conventional approaches to vali-date the performance of the proposed method.In addition,the experimental results provided by the Field Programmable Gate Array(FPGA)based laboratory setup built using a solar photovoltaic(PV)and wind Permanent Magnet Synchro-nous Generator(PMSG)reaffirms the design.展开更多
This paper presentsand describes harmonic measurement and analysis of studying harmonic propagation during electric vehicle (EV) charging. The measurement study is performed on a golf cart and two modern type of EVs. ...This paper presentsand describes harmonic measurement and analysis of studying harmonic propagation during electric vehicle (EV) charging. The measurement study is performed on a golf cart and two modern type of EVs. Harmonics from a single EV charging and a group of EV charging was measured. The voltage and current waveform during the charging was captured and analyzed to investigate the harmonic components that exist in the electrical system. Total current harmonic distortion (THDi) and total voltage harmonic distortion (THDi) were both calculated. Modern electric vehicles are found to release low THDi but higher THDv compared to a golf cart. On the measurement study during charging of? a group of EV, it is found that the summation of THD is not linear with a number of vehicles. The finding of the study reveals that harmonic contamination from EV charging on electrical grid is not as critical as thought by most of power system researchers and engineers.展开更多
Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for...Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for ski-lift in ski resort as a source of disturbances with negative impact on sensitive electric equipment, which is then unable to operate correctly. To solve mentioned problems, series of measurements of voltage quality parameters were carried out according to the respective valid standards. Crucial power quality parameters necessary for parallel power active filter design were then analyzed. Power active filter compensates power factor and filters characteristic current harmonics. After power active filter was put into operation, power quality problems were eliminated. Payback period is estimated up to four years.展开更多
The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Th...The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient.展开更多
文摘Multi-level inverters(MLIs)have become popular in different applications such as industrial power control systems and distributed generations.There are different forms of MLIs.The cascaded MLIs(CMLIs)have some special advantages among them such as more different output voltage levels using the same number of components and higher power quality.In this paper,a 27-level inverter switching algorithm considering total harmonic distortion(THD)minimization is investigated.Switching angles of the inverter switches are achieved by minimizing a THD-based objective function.In order to minimize the THD-based objective function,the hyper-spherical search(HSS)algorithm,as a novel optimization algorithm,is improved and the results of improved HSS(IHSS)are compared with HSS algorithm and other five evolutionary algorithms to show the advantages of IHSS algorithm.
文摘This multilevel inverter methodology is the center of focus among researchers in recent era.It has been focused due to its advantages over existing topologies,drawbacks and improvement of power quality,Multi-level inverter has the ability to generate nearly sinusoidal waves.This sinusoidal wave can be further improved by increasing the level of output voltage or with the help of filter design,and this manuscript presents single-phase Multi cell Multi-Level Inverter(MLI).It has been considered for reducing component count to get a higher number of output voltage levels and lower Total harmonics distortion profile.It comprises with four symmetric DC input voltage and 10 IGBT switches to produces stepped output of 9 level,and when deploy asymmetric Dc voltage source the same circuit will produce 31 level output with some changes in firing scheme,moreover this circuit is the family of cascaded hybrid bridge inverter so this circuit covered advantage of CHB MLI,This circuit uses lower no.of switch as compared to existing conventional MLIs such as FC-MLI,CHB-MLI,NPC-MLI,This paper also provides one of most pertinent controls and modulation mechanisms for a MLI using a hybrid reference/carrier-oriented sinusoidal PWM mechanism.At last,simulated outcomes are to validate the performance of both architectures in MLI structure as well as verify the concept.
文摘In recent day’s power distribution system is distress from acute power quality issues.In this work,for compensating Power Quality(PQ)disturbances a seven level cascaded H-bridge inverter is implemented in distribution static com-pensator which protects power quality problems in currents.Distribution Static Compensator(DSTATCOM)aid to enhances power factor and removes total har-monic distortion which is drawn from non-linear load.The D–Q reference theory based hysteresis current controller is employed to generate reference current for compensation of harmonics and reactive power,additionally Probabilistic Neural Network(PNN)classifier is used which easily separates exact harmonics.In the meantime fuzzy logic controller is also used to maintain capacitor DC-link poten-tial.When comparing to PI controller it decreases steady state time and reduces maximum peak overshoot.Cascaded H-bridge multilevel inverter converts direct current to Alternating current,through inductor opposite harmonics are injected in Power Control Centre reduces source current harmonics and reactive power.The implementation of CHBMLI in distribution STATic COMpensator simulation model is simulated by means of MATLAB.
文摘Power quality challenges have generated a lot of disputes between utilities,customers,network operators,and equipment manufacturers around the world as regards the share of responsibility for power quality solutions,this results in different levels of financial and technical losses for both the network operators and the customers.One of the major consequences of the operation of heavy-duty factories globally is the corruption of power quality at the point of common coupling(PCC).In order to quantify the harmonics contribution at the PCC by industrial consumers,this paper presents three-phase total harmonics distortion of current(THDi)prediction model at the PCC.The proposed artificial neural network(ANN)models use a multilayer perceptron neural network(MLPN)to predict three-phase total harmonic distortion.The input parameter used in the models is easily measured with basic power meters.The model was trained with input parameters captured at 33 kV and 132 kV voltage levels using power quality meters at five(5)different steel manufacturing plants.Eight(8)different models were designed,trained,validated,and tested with different combinations of input parameters,number of hidden layers,and number of neurons in the hidden layer.The results show that the model with two hidden layers which uses four major power parameters(Current,apparent power,reactive and active power)as input parameters in the training model had the best performance with a 95.5%coefficient of correlation between the measured THDi and the predicted THDi.
文摘Based on theoretical inference and computer simulation,the relationship between the harmonics and the parameters of SPWM was widely investigated.The rule of the total harmonic distortion and the harmonic spectrum distribution has been obtained.In order to decrease the harmonics,the selecting methods for optimal magnitude of the amplitude modularity and the frequency modularity are also given.
文摘Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.
文摘Like others countries of the world, in Niger also, we are witnessing an increasing use of non-linear electric loads in the domestic, hospital and industrial sectors. However, these loads degrade the shape of the electrical signal and cause disastrous effects to the equipment of the distribution system and the devices which are connected to the network. This article highlights the presence of electric harmonics in the distribution network in Niamey city. In order to do this, measurements were taken at the secondary level of the substations using an energy quality analyze r (FLUKE 1735). By using this measuring instrument, we quantified the voltage and current Total Harmonic Distortion (THD) in the three substations. The results obtained show that, although the statutable rates set by the standards are not exceeded for phase conductors, the neutral contains a very critical percentage of distortion on the residential and hospital substations. Moreover, this assessment made it possible to observe the variation of harmonics in the presence of voltage drops.
文摘In this paper, the authors analyze the influence that connection of many distributed generators (DGs) has on the harmonics of the distribution network from the viewpoints of harmonic current, harmonic voltage, and voltage total harmonic distortion (THD), when it is assumed that the harmonic voltages or the harmonic currents in a distribution network increases by connection of many DGs through the inverters. The analysis on the influence of DGs is carried out by using a standard analytical model of distribution network with DGs based on the practical data. The authors evaluate quantitatively the influence which harmonics generated from DGs has on the harmonics of the distribution network, and analyze visually about propagation of harmonics within the distribution network. In addition, the authors also verify about the restraint effect of the harmonics in the network scale by the active filters installation.
文摘The contribution of Renewable Energy Resources(RER)in the process of power generation is significantly high in the recent days since it paves the way for overcoming the issues like serious energy crisis and natural contamination.This paper deals with the renewable energy based micro-grid as it is regarded as the apt solution for integrating the RER with the electrical frameworks.As thefixed droop coefficients in conventional droop control approaches have caused various limitations like low power-sharing and sudden drops of grid voltage in the Direct Current(DC)side,the Harmonized Membership Fuzzy Logic(MFL)droop control is employed in this present study.This proposed droop control for the hybrid PV-wind-battery system with MFL assists in achieving proper power-sharing and minimizing Total Harmonic Distortion(THD)in the emer-gency micro-grid.It eradicates the deviations in voltage and frequency with itsflexible and robust operation.The THD is reduced and attains the value of 3.1%compared to the traditional droop control.The simulation results of harmo-nized MFL droop control are analogized with the conventional approaches to vali-date the performance of the proposed method.In addition,the experimental results provided by the Field Programmable Gate Array(FPGA)based laboratory setup built using a solar photovoltaic(PV)and wind Permanent Magnet Synchro-nous Generator(PMSG)reaffirms the design.
文摘This paper presentsand describes harmonic measurement and analysis of studying harmonic propagation during electric vehicle (EV) charging. The measurement study is performed on a golf cart and two modern type of EVs. Harmonics from a single EV charging and a group of EV charging was measured. The voltage and current waveform during the charging was captured and analyzed to investigate the harmonic components that exist in the electrical system. Total current harmonic distortion (THDi) and total voltage harmonic distortion (THDi) were both calculated. Modern electric vehicles are found to release low THDi but higher THDv compared to a golf cart. On the measurement study during charging of? a group of EV, it is found that the summation of THD is not linear with a number of vehicles. The finding of the study reveals that harmonic contamination from EV charging on electrical grid is not as critical as thought by most of power system researchers and engineers.
文摘Distribution systems operators are often confronted with declined power quality, which can cause substantial economical losses. The problem analyzed in paper concerns thyristor controlled direct current motor used for ski-lift in ski resort as a source of disturbances with negative impact on sensitive electric equipment, which is then unable to operate correctly. To solve mentioned problems, series of measurements of voltage quality parameters were carried out according to the respective valid standards. Crucial power quality parameters necessary for parallel power active filter design were then analyzed. Power active filter compensates power factor and filters characteristic current harmonics. After power active filter was put into operation, power quality problems were eliminated. Payback period is estimated up to four years.
文摘The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient.