Osteoporotic hip fracture is associated with significant trabecular bone loss, which is typically characterized as low bone density by dual-energy X-ray absorptiometry (DXA) and altered microstructure by micro-compu...Osteoporotic hip fracture is associated with significant trabecular bone loss, which is typically characterized as low bone density by dual-energy X-ray absorptiometry (DXA) and altered microstructure by micro-computed tomography (pCT). Emerging morphological analysis techniques, e.g. individual trabecula segmentation (ITS), can provide additional insights into changes in plate-like and rod-like trabeculae, two major micro- structural types serving different roles in determining bone strength. Using ITS, we evaluated trabecular microstructure of intertrochanteric bone cores obtained from 23 patients undergoing hip replacement surgery for intertrochanteric fracture and 22 cadaveric controls. Micro-finite element (~FE) analyses were performed to further understand how the abnormalities seen by ITS might translate into effects on bone strength. ITS analyses revealed that, near fracture site, plate-like trabeculae were seriously depleted in fracture patients, but trabecular rod volume was maintained. Besides, decreased plate area and rod length were observed in fracture patients. Fracture patients also showed decreased elastic moduli and shear moduli of trabecular bone. These results provided evidence that in intertrochanteric hip fracture, preferential loss of plate-like trabeculae led to more rod-like microstructure and deteriorated mechanical competence adjacent to the fracture site, which increased our understanding of the biomechanical pathogenesis of hip fracture in osteoporosis.展开更多
Introduction Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles of human heart and account for a significant portion of the ventricular mass.However,the role of trabecul...Introduction Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles of human heart and account for a significant portion of the ventricular mass.However,the role of trabeculae carneae in left ventricular(LV)function is not well understood.Previous reports suggested that trabeculae help squeeze blood from the apical region during systole[1].Our recent study suggests that trabeculae carneae hypertrophy and fibrosis contribute to increased LV stiffness in patients with diastolic heart failure,and severing free-running trabeculae carneae may improve diastolic compliance of the LV[2].Objective To understand the role of trabeculae carneae in the left ventricular diastolic and systolic functions using anatomically detailed patient-specific finite element models of the human LV.Methods(1)Image acquisition An explanted human heart was collected from a 63 year old female donor with a history of stroke and congestive heart failure within 24 hours postmortem from South Texas Blood and Tissue Center(San Antonio,TX).The heart was de-identified in accordance with Institutional Review Board(IRB)requirements and informed consent for research was obtained from the donor’s family.Three-dimensional MRI scanning was conducted on a 3T(128 MHz)MRI system(TIM Trio,Siemens Medical Solutions),comprised of a superconducting magnet with a 60 cm diameter accessible bore,when the heart was submerged in a saline filled plastic container.(2)Finite element analysis Three distinct LV models were derived from the MR images.The first model was the intact trabeculated model(TM)which contained all trabeculae carneae and papillary muscles.This high-resolution anatomically detailed 3D model of the LV was segmented from 2D MR images in DICOM format using Mimics(Materialise NV,Leuven,Belgium).The second model was the papillary model(PM),in which the papillary muscles remain intact but most of the trabeculae carneae were excluded in the smoothing process.The third model was the smooth model(SM)in which the trabeculae carneae and papillary muscles were excluded during image segmentation.Finite element(FE)models of the TM,PM and SM were created by meshing 3D reconstructions of the acquired MR images using tetrahedral elements(ICEM,Ansys Inc.,Canonsburg,PA).The mesh size was selected after a pilot study on mesh sensitivity.The passive cardiac muscle was characterized as a hyperelastic,incompressible,transversely isotropic material with a Fung exponential strain energy function.The material constants were determined by matching the end-diastolic pressure-volume relationship with the empirical Klotz relation[3].A rule-based myocardial fiber algorithm was adopted to generate the myofiber directions [4].The active contraction(i.e.,systolic contraction)was modeled by the time varying'Elastance'active contraction model.The contractile parameter Tmax was determined and calibrated so that the FE predicted ejection fraction(EF)of TM matched the EF of a normal human heart at the specified end-systolic pressure[3].The analysis of the TM,PM,and SM models were implemented using the open-source finite element package FEBio(www.febio.org).In all models,the rigid body motion was suppressed by constraining the base from moving in all directions.The end-diastolic and end-systolic pressure-volume relationships(EDPVR and ESPVR)were obtained and characterized by an exponential function and the slope,respectively.Results Our simulation results showed that independent of the material model,the EDPVR curve shifts to the right in PM and SM compared to TM.However,the ESPVR curve may shift to the right or left in PM compared to TM,while shifting tothe right in SM for all material models.EDPVR was steeper in TM compared to PM and SM;however,ESPVR was found to be steeper in PM than in TM and SM.The predicted parameters of EDPVR and ESPVR showed lower average exponential term in PM and SM compared to TM,indicating a significant improvement in the compliance and global diastolic function of less trabeculated LV models(P<0.01).Similarly,the higher average elastance EEs and lower volume intersect in PM compared to TM,suggests that mild cutting of trabeculae carneae slightly improves the global systolic function of the LV(P=0.89).However,cutting all trabeculae carneae and papillary muscles in SM had a significant adverse effect on the global systolic function(P<0.01).Discussion and conclusions Most patient-specific LV studies in the literature have used smoothed ventricular geometries.We used high resolution MRI to capture the endocardial details of the LV.Though reproducing very fine trabeculae carneae was restricted by the MRI resolution,our results demonstrated the importance of considering endocardial structures,i.e.papillary muscles and trabeculae carneae,in the assessment of LV global function in patient-specific computational LV models.The present work is consistent with the observation that diastolic performance improved after severing trabeculae carneae due to a reduction in LV stiffness[2].Furthermore,our results also suggest that severing trabeculae carneae(without affecting papillary muscle)may improve LV systolic function.Our model results are consistent with experimental measurements using ex vivo rabbit heart perfusion [5].This improvement would be greater in hypertrophic hearts because trabeculae carneae are also hypertrophic and more fibrotic.Left ventricular hypertrophy is often associated with heart failure with preserved ejection fraction(HFpEF).There is no effective treatment for HFpEF,which is characterized by impaired diastolic relaxation due to increased LV stiffness.Our results indicate that trabecular cutting could be an effective treatment for HFpEF.展开更多
The regional microstructural variations in femoral head from proximal femoral fracture patients were investigated. Mi- cro-CT scanning was performed on seven femoral heads from proximal femoral fracture patients. Each...The regional microstructural variations in femoral head from proximal femoral fracture patients were investigated. Mi- cro-CT scanning was performed on seven femoral heads from proximal femoral fracture patients. Each femoral head was divided into three regions according to the trabecular orientation from the fovea of femoral head to the femoral neck. Eight three-dimensional trabecular cube models were reconstructed from each region. A total of 154 trabecular cubic models were reconstructed because the corresponding areas for 14 cubic models were damaged during the surgeries. Eight trabecular mor- phological parameters were measured and analyzed, namely, trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), spe- cific bone surface (BS/BV), bone volum在不 fraction (BV/TV), structural model index (SMI), degree of anisotropy (DA), trabecular pattern factor (Tb.Pf), and trabecular number (Tb.N). Bivariate correlation analyses were performed for all mor- phological parameters. One-way ANOVA tests were performed to analyze the differences of each parameter among three re- gions. Post-hoc multiple comparisons (Student-Newman-Keuls method) were performed to analyze the morphological differ- ence between two regions. Trabecular bone of proximal femoral fracture patients significantly degenerated in all regions of femoral heads. BV/TV was statistically correlated with Tb.Th, Tb.Sp, BS/BV, Tb.Pf, and Tb.N (p 〈 0.05). Statistical differences in morphological parameters were observed between regions (p 〈 0.05). The trabecular strength in the middle regions was significantly higher than that in other regions because of the relationships between morphological parameters and mechanical parameters. Trabeculae in the medial region were more uniform and stable along each direction than those in the lateral region. Most trabeculae in the lateral region only grew along the weight-bearing direction, and those along the other directions de- generated significantly. This study provides detailed trabecular morphological information on fractured femoral heads, as well as references for the prevention of high fracture risk in the elderly.展开更多
To improve the mechanical properties of Trabecular Beetle Elytron Plates(TBEPs,a type of biomimetic sandwich structure inspired by the beetle elytron)under transverse loads,three-point bending tests are performed to i...To improve the mechanical properties of Trabecular Beetle Elytron Plates(TBEPs,a type of biomimetic sandwich structure inspired by the beetle elytron)under transverse loads,three-point bending tests are performed to investigate the influence of the trabecular and chamfer radii of the core structure on the mechanical performance of TBEPs manufactured by 3D printing technology.The results show that the three-point bending performance of TBEPs can be improved by setting reasonable trabecular and chamfer radii;however,excessive increases in these radii can cause a decline in the mechanical performance.For the reason,these two structural parameters can enhance the deformation stiffness of the whole structure and the connection property between the core and skin,which is also the mechanical reason why Prosopocoilus inclinatus beetle elytra have thick,short trabeculae with a large chamfer radius.However,when these radii increase to a certain extent,the cracks are ultimately controlled between two adjacent trabeculae,and the failure of the plate is determined by the skin rather than the core structure.Therefore,this study suggests a reasonable range for trabecular and chamfer radii,and indicates that TBEPs are better suited for engineering applications that have high compression requirements and general bending requirements.展开更多
We studied ultrastructurally the cancellons bone tissues of the upper femoral ends, collected from 12 patients undergoing endoprostbesis replacement for fractures of the femoral neck and from 7 fresh cadavers. The bon...We studied ultrastructurally the cancellons bone tissues of the upper femoral ends, collected from 12 patients undergoing endoprostbesis replacement for fractures of the femoral neck and from 7 fresh cadavers. The bone tissues were composed of meshwork of trabeculae, that constituted tier upon tier of anisotropic arch structures of different diameters and sizes. The arch structures of the cancellous bone tissues in the femoral heads assumed round or roundish configurations, whereas those of the femoral head-neck junctions revealed oval outlines and those of the femoral necks showed narrow oval profiles. The fine structures of the trabecnlae in the femoral head could be divided into superficial zone, central zone, and transitional zone. Under weight-bearing, the central zone suited to sustain the load, while the superficial zone could produce elastic deformation lest fracture of the trabecaulae should ensue. The long axes of the oval arch structures of the femoral head-neck junction and the narrow oval arch structures of the femoral neck coincided with those of the femoral neck, thereby facilitating weight-bearing under physiological conditions. However, external violence in the form of either adduction or abduction force would act in a horizontal direction on the long axes of the oval and narrow oval arches so as to produce subcapital or transverse fracture of the femur in the aged.展开更多
目的 采用定量非对称回波的最小二乘估算法迭代水脂分离序列(iterative decomposition of water and fat with echo asymmetry and least-squares estimation quantitation sequence, IDEAL-IQ)联合计算机显微断层扫描(micro computed t...目的 采用定量非对称回波的最小二乘估算法迭代水脂分离序列(iterative decomposition of water and fat with echo asymmetry and least-squares estimation quantitation sequence, IDEAL-IQ)联合计算机显微断层扫描(micro computed tomography, Micro-CT)技术评估兔1型糖尿病腰椎骨髓脂肪含量和骨小梁微结构相关性。材料与方法 将16只雄性日本大耳白兔随机分为糖尿病组(n=8)和对照组(n=8),糖尿病组采用四氧嘧啶造模。在造模成功后第0、4、8、12、16周通过IDEAL-IQ定量评估兔腰椎骨髓脂肪含量。在第16周采用Micro-CT及组织病理学检查对兔腰椎骨小梁微结构进行定量评估。不同时间点腰椎IDEAL-IQ脂肪分数差异比较采用重复测量方差分析;同一时间点组间脂肪分数、Micro-CT骨小梁形态计量学参数、组织病理学参数差异比较采用独立样t检验或Mann-Whitney U检验;采用Pearson相关系数评估骨髓脂肪分数与骨小梁形态计量学参数、组织病理学参数相关性。结果 糖尿病组骨髓脂肪含量随时间变化呈上升趋势,且差异存在统计学意义(P<0.05),而对照组各时间点脂肪含量差异无统计学意义(P>0.05);糖尿病组与对照组腰椎骨髓脂肪分数在第16周差异有统计学意义(59.987±4.859 vs. 51.015±8.469,P<0.05);第16周糖尿病组骨体积、总表面积、骨表面积、骨表面积总体积比、骨小梁数量均低于对照组,而骨小梁分离度高于对照组,差异有统计学意义(P<0.05);组织病理学结果显示,与对照组相比,第16周糖尿病兔腰椎骨髓脂肪细胞数量(32.875±11.051 vs. 71.667±13.125, P<0.01)增加,而骨小梁数量(11.375±1.506vs.4.333±1.211, P<0.01)与骨小梁面积(0.927±0.071vs.0.312±0.100, P<0.01)明显减少;IDEAL-IQ脂肪分数与组织病理学脂肪细胞计数呈正相关关系(r=0.539 95%CI:0.012~0.832),与骨小梁模式因子、骨小梁结构模型指数、骨小梁分离度呈轻中度正相关关系,与骨矿物质密度、总体积、骨体积、骨体积分数、总表面积、骨表面积、骨表面积体积比、骨表面积总体积比、骨小梁数量呈轻至中度负相关关系。结论 1型糖尿病腰椎骨髓脂肪含量与骨小梁微结构变化存在相关性,IDEAL-IQ联合Micro-CT的多模态定量影像技术有望为1型糖尿病提供全面的骨髓微环境评估策略。展开更多
基金This work was partially supported by grants from National Institutes of Health(AR051376,AR058004)
文摘Osteoporotic hip fracture is associated with significant trabecular bone loss, which is typically characterized as low bone density by dual-energy X-ray absorptiometry (DXA) and altered microstructure by micro-computed tomography (pCT). Emerging morphological analysis techniques, e.g. individual trabecula segmentation (ITS), can provide additional insights into changes in plate-like and rod-like trabeculae, two major micro- structural types serving different roles in determining bone strength. Using ITS, we evaluated trabecular microstructure of intertrochanteric bone cores obtained from 23 patients undergoing hip replacement surgery for intertrochanteric fracture and 22 cadaveric controls. Micro-finite element (~FE) analyses were performed to further understand how the abnormalities seen by ITS might translate into effects on bone strength. ITS analyses revealed that, near fracture site, plate-like trabeculae were seriously depleted in fracture patients, but trabecular rod volume was maintained. Besides, decreased plate area and rod length were observed in fracture patients. Fracture patients also showed decreased elastic moduli and shear moduli of trabecular bone. These results provided evidence that in intertrochanteric hip fracture, preferential loss of plate-like trabeculae led to more rod-like microstructure and deteriorated mechanical competence adjacent to the fracture site, which increased our understanding of the biomechanical pathogenesis of hip fracture in osteoporosis.
基金supported by a National Innovation Award ( 15IRG23320009) from the American Heart Association
文摘Introduction Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles of human heart and account for a significant portion of the ventricular mass.However,the role of trabeculae carneae in left ventricular(LV)function is not well understood.Previous reports suggested that trabeculae help squeeze blood from the apical region during systole[1].Our recent study suggests that trabeculae carneae hypertrophy and fibrosis contribute to increased LV stiffness in patients with diastolic heart failure,and severing free-running trabeculae carneae may improve diastolic compliance of the LV[2].Objective To understand the role of trabeculae carneae in the left ventricular diastolic and systolic functions using anatomically detailed patient-specific finite element models of the human LV.Methods(1)Image acquisition An explanted human heart was collected from a 63 year old female donor with a history of stroke and congestive heart failure within 24 hours postmortem from South Texas Blood and Tissue Center(San Antonio,TX).The heart was de-identified in accordance with Institutional Review Board(IRB)requirements and informed consent for research was obtained from the donor’s family.Three-dimensional MRI scanning was conducted on a 3T(128 MHz)MRI system(TIM Trio,Siemens Medical Solutions),comprised of a superconducting magnet with a 60 cm diameter accessible bore,when the heart was submerged in a saline filled plastic container.(2)Finite element analysis Three distinct LV models were derived from the MR images.The first model was the intact trabeculated model(TM)which contained all trabeculae carneae and papillary muscles.This high-resolution anatomically detailed 3D model of the LV was segmented from 2D MR images in DICOM format using Mimics(Materialise NV,Leuven,Belgium).The second model was the papillary model(PM),in which the papillary muscles remain intact but most of the trabeculae carneae were excluded in the smoothing process.The third model was the smooth model(SM)in which the trabeculae carneae and papillary muscles were excluded during image segmentation.Finite element(FE)models of the TM,PM and SM were created by meshing 3D reconstructions of the acquired MR images using tetrahedral elements(ICEM,Ansys Inc.,Canonsburg,PA).The mesh size was selected after a pilot study on mesh sensitivity.The passive cardiac muscle was characterized as a hyperelastic,incompressible,transversely isotropic material with a Fung exponential strain energy function.The material constants were determined by matching the end-diastolic pressure-volume relationship with the empirical Klotz relation[3].A rule-based myocardial fiber algorithm was adopted to generate the myofiber directions [4].The active contraction(i.e.,systolic contraction)was modeled by the time varying'Elastance'active contraction model.The contractile parameter Tmax was determined and calibrated so that the FE predicted ejection fraction(EF)of TM matched the EF of a normal human heart at the specified end-systolic pressure[3].The analysis of the TM,PM,and SM models were implemented using the open-source finite element package FEBio(www.febio.org).In all models,the rigid body motion was suppressed by constraining the base from moving in all directions.The end-diastolic and end-systolic pressure-volume relationships(EDPVR and ESPVR)were obtained and characterized by an exponential function and the slope,respectively.Results Our simulation results showed that independent of the material model,the EDPVR curve shifts to the right in PM and SM compared to TM.However,the ESPVR curve may shift to the right or left in PM compared to TM,while shifting tothe right in SM for all material models.EDPVR was steeper in TM compared to PM and SM;however,ESPVR was found to be steeper in PM than in TM and SM.The predicted parameters of EDPVR and ESPVR showed lower average exponential term in PM and SM compared to TM,indicating a significant improvement in the compliance and global diastolic function of less trabeculated LV models(P<0.01).Similarly,the higher average elastance EEs and lower volume intersect in PM compared to TM,suggests that mild cutting of trabeculae carneae slightly improves the global systolic function of the LV(P=0.89).However,cutting all trabeculae carneae and papillary muscles in SM had a significant adverse effect on the global systolic function(P<0.01).Discussion and conclusions Most patient-specific LV studies in the literature have used smoothed ventricular geometries.We used high resolution MRI to capture the endocardial details of the LV.Though reproducing very fine trabeculae carneae was restricted by the MRI resolution,our results demonstrated the importance of considering endocardial structures,i.e.papillary muscles and trabeculae carneae,in the assessment of LV global function in patient-specific computational LV models.The present work is consistent with the observation that diastolic performance improved after severing trabeculae carneae due to a reduction in LV stiffness[2].Furthermore,our results also suggest that severing trabeculae carneae(without affecting papillary muscle)may improve LV systolic function.Our model results are consistent with experimental measurements using ex vivo rabbit heart perfusion [5].This improvement would be greater in hypertrophic hearts because trabeculae carneae are also hypertrophic and more fibrotic.Left ventricular hypertrophy is often associated with heart failure with preserved ejection fraction(HFpEF).There is no effective treatment for HFpEF,which is characterized by impaired diastolic relaxation due to increased LV stiffness.Our results indicate that trabecular cutting could be an effective treatment for HFpEF.
基金This work is supported by the National Natural Science foundation of China (Nos. 11322223, 11432016, 81471753), and the 973 Program (No. 2012CB821202).
文摘The regional microstructural variations in femoral head from proximal femoral fracture patients were investigated. Mi- cro-CT scanning was performed on seven femoral heads from proximal femoral fracture patients. Each femoral head was divided into three regions according to the trabecular orientation from the fovea of femoral head to the femoral neck. Eight three-dimensional trabecular cube models were reconstructed from each region. A total of 154 trabecular cubic models were reconstructed because the corresponding areas for 14 cubic models were damaged during the surgeries. Eight trabecular mor- phological parameters were measured and analyzed, namely, trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), spe- cific bone surface (BS/BV), bone volum在不 fraction (BV/TV), structural model index (SMI), degree of anisotropy (DA), trabecular pattern factor (Tb.Pf), and trabecular number (Tb.N). Bivariate correlation analyses were performed for all mor- phological parameters. One-way ANOVA tests were performed to analyze the differences of each parameter among three re- gions. Post-hoc multiple comparisons (Student-Newman-Keuls method) were performed to analyze the morphological differ- ence between two regions. Trabecular bone of proximal femoral fracture patients significantly degenerated in all regions of femoral heads. BV/TV was statistically correlated with Tb.Th, Tb.Sp, BS/BV, Tb.Pf, and Tb.N (p 〈 0.05). Statistical differences in morphological parameters were observed between regions (p 〈 0.05). The trabecular strength in the middle regions was significantly higher than that in other regions because of the relationships between morphological parameters and mechanical parameters. Trabeculae in the medial region were more uniform and stable along each direction than those in the lateral region. Most trabeculae in the lateral region only grew along the weight-bearing direction, and those along the other directions de- generated significantly. This study provides detailed trabecular morphological information on fractured femoral heads, as well as references for the prevention of high fracture risk in the elderly.
基金The work was financially supported by the National Key R&D Program of China under project 2017YFC0703700.
文摘To improve the mechanical properties of Trabecular Beetle Elytron Plates(TBEPs,a type of biomimetic sandwich structure inspired by the beetle elytron)under transverse loads,three-point bending tests are performed to investigate the influence of the trabecular and chamfer radii of the core structure on the mechanical performance of TBEPs manufactured by 3D printing technology.The results show that the three-point bending performance of TBEPs can be improved by setting reasonable trabecular and chamfer radii;however,excessive increases in these radii can cause a decline in the mechanical performance.For the reason,these two structural parameters can enhance the deformation stiffness of the whole structure and the connection property between the core and skin,which is also the mechanical reason why Prosopocoilus inclinatus beetle elytra have thick,short trabeculae with a large chamfer radius.However,when these radii increase to a certain extent,the cracks are ultimately controlled between two adjacent trabeculae,and the failure of the plate is determined by the skin rather than the core structure.Therefore,this study suggests a reasonable range for trabecular and chamfer radii,and indicates that TBEPs are better suited for engineering applications that have high compression requirements and general bending requirements.
文摘We studied ultrastructurally the cancellons bone tissues of the upper femoral ends, collected from 12 patients undergoing endoprostbesis replacement for fractures of the femoral neck and from 7 fresh cadavers. The bone tissues were composed of meshwork of trabeculae, that constituted tier upon tier of anisotropic arch structures of different diameters and sizes. The arch structures of the cancellous bone tissues in the femoral heads assumed round or roundish configurations, whereas those of the femoral head-neck junctions revealed oval outlines and those of the femoral necks showed narrow oval profiles. The fine structures of the trabecnlae in the femoral head could be divided into superficial zone, central zone, and transitional zone. Under weight-bearing, the central zone suited to sustain the load, while the superficial zone could produce elastic deformation lest fracture of the trabecaulae should ensue. The long axes of the oval arch structures of the femoral head-neck junction and the narrow oval arch structures of the femoral neck coincided with those of the femoral neck, thereby facilitating weight-bearing under physiological conditions. However, external violence in the form of either adduction or abduction force would act in a horizontal direction on the long axes of the oval and narrow oval arches so as to produce subcapital or transverse fracture of the femur in the aged.
文摘目的 采用定量非对称回波的最小二乘估算法迭代水脂分离序列(iterative decomposition of water and fat with echo asymmetry and least-squares estimation quantitation sequence, IDEAL-IQ)联合计算机显微断层扫描(micro computed tomography, Micro-CT)技术评估兔1型糖尿病腰椎骨髓脂肪含量和骨小梁微结构相关性。材料与方法 将16只雄性日本大耳白兔随机分为糖尿病组(n=8)和对照组(n=8),糖尿病组采用四氧嘧啶造模。在造模成功后第0、4、8、12、16周通过IDEAL-IQ定量评估兔腰椎骨髓脂肪含量。在第16周采用Micro-CT及组织病理学检查对兔腰椎骨小梁微结构进行定量评估。不同时间点腰椎IDEAL-IQ脂肪分数差异比较采用重复测量方差分析;同一时间点组间脂肪分数、Micro-CT骨小梁形态计量学参数、组织病理学参数差异比较采用独立样t检验或Mann-Whitney U检验;采用Pearson相关系数评估骨髓脂肪分数与骨小梁形态计量学参数、组织病理学参数相关性。结果 糖尿病组骨髓脂肪含量随时间变化呈上升趋势,且差异存在统计学意义(P<0.05),而对照组各时间点脂肪含量差异无统计学意义(P>0.05);糖尿病组与对照组腰椎骨髓脂肪分数在第16周差异有统计学意义(59.987±4.859 vs. 51.015±8.469,P<0.05);第16周糖尿病组骨体积、总表面积、骨表面积、骨表面积总体积比、骨小梁数量均低于对照组,而骨小梁分离度高于对照组,差异有统计学意义(P<0.05);组织病理学结果显示,与对照组相比,第16周糖尿病兔腰椎骨髓脂肪细胞数量(32.875±11.051 vs. 71.667±13.125, P<0.01)增加,而骨小梁数量(11.375±1.506vs.4.333±1.211, P<0.01)与骨小梁面积(0.927±0.071vs.0.312±0.100, P<0.01)明显减少;IDEAL-IQ脂肪分数与组织病理学脂肪细胞计数呈正相关关系(r=0.539 95%CI:0.012~0.832),与骨小梁模式因子、骨小梁结构模型指数、骨小梁分离度呈轻中度正相关关系,与骨矿物质密度、总体积、骨体积、骨体积分数、总表面积、骨表面积、骨表面积体积比、骨表面积总体积比、骨小梁数量呈轻至中度负相关关系。结论 1型糖尿病腰椎骨髓脂肪含量与骨小梁微结构变化存在相关性,IDEAL-IQ联合Micro-CT的多模态定量影像技术有望为1型糖尿病提供全面的骨髓微环境评估策略。