An advanced configuration for multilevel voltage source converters is proposed. The proposed converter is able to apply asymmetrical DC sources. The configuration of the proposed inverter is well designed in order to ...An advanced configuration for multilevel voltage source converters is proposed. The proposed converter is able to apply asymmetrical DC sources. The configuration of the proposed inverter is well designed in order to provide the maximum number of voltage levels in output terminals using lower number of circuit devices. The authority of the proposed inverter versus the conventional H-bridge cascaded inverter and the most recently introduced ones, is verified with a provided comparison study. The proposed inverter is able to generate the desired voltage levels using a lower number of circuit devices including power semi-conductor switches, IGBTs, diodes, related gate driver circuits of switches and DC voltage sources. As a result, the total cost and installation area are considerably reduced and the control scheme gets simpler. To confirm the feasibility of the proposed multilevel structure, both the simulation and experimental results are provided and compared which shows good agreements.展开更多
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe...The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method.展开更多
逆变器的安全性和可靠性直接关系到电机驱动系统的正常运行。在研究逆变器在正常和故障状态下开关函数模型的基础上,提出一种功率管开路故障快速简易诊断方法。该方法根据故障和正常态器件承受电压的不同,采用简单的硬件电路来诊断和定...逆变器的安全性和可靠性直接关系到电机驱动系统的正常运行。在研究逆变器在正常和故障状态下开关函数模型的基础上,提出一种功率管开路故障快速简易诊断方法。该方法根据故障和正常态器件承受电压的不同,采用简单的硬件电路来诊断和定位器件的开路故障。为保障诊断的有效性和可靠性,提出采用开关信号上升沿延时的方法来避免因IGBT开通和关断延迟造成的误诊断,并给出延时时间的确定方法。在搭建的感应电机变频调速(variable voltage and variable frequency,VVVF)控制和永磁同步电动机矢量控制系统中进行实验验证,实验结果表明,所提故障诊断方法能有效诊断逆变器单管和桥臂的开路故障。展开更多
文摘An advanced configuration for multilevel voltage source converters is proposed. The proposed converter is able to apply asymmetrical DC sources. The configuration of the proposed inverter is well designed in order to provide the maximum number of voltage levels in output terminals using lower number of circuit devices. The authority of the proposed inverter versus the conventional H-bridge cascaded inverter and the most recently introduced ones, is verified with a provided comparison study. The proposed inverter is able to generate the desired voltage levels using a lower number of circuit devices including power semi-conductor switches, IGBTs, diodes, related gate driver circuits of switches and DC voltage sources. As a result, the total cost and installation area are considerably reduced and the control scheme gets simpler. To confirm the feasibility of the proposed multilevel structure, both the simulation and experimental results are provided and compared which shows good agreements.
基金the Foundation of a Hundred Youth Talents Training Program of Lanzhou Jiaotong University under Grant No.2018-103the Colleges and University Scientific Research Funds of Gansu Province under Grant No.2017A-026。
文摘The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method.
文摘逆变器的安全性和可靠性直接关系到电机驱动系统的正常运行。在研究逆变器在正常和故障状态下开关函数模型的基础上,提出一种功率管开路故障快速简易诊断方法。该方法根据故障和正常态器件承受电压的不同,采用简单的硬件电路来诊断和定位器件的开路故障。为保障诊断的有效性和可靠性,提出采用开关信号上升沿延时的方法来避免因IGBT开通和关断延迟造成的误诊断,并给出延时时间的确定方法。在搭建的感应电机变频调速(variable voltage and variable frequency,VVVF)控制和永磁同步电动机矢量控制系统中进行实验验证,实验结果表明,所提故障诊断方法能有效诊断逆变器单管和桥臂的开路故障。