期刊文献+
共找到53篇文章
< 1 2 3 >
每页显示 20 50 100
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
1
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 肺的静脉 导管脱离 Atrial 纤维性颤动 transesophageal echocardiography 三维的 echocardiography
下载PDF
Noninvasive Assessment of Cardiac Index with Transesophageal Echocardiography in Patients Undergoing Mitral Valve Replacement: A Comparison between Determinations at the Mitral Valve and the Ascending Aorta 被引量:2
2
作者 Xiaoju Hu Hongwei Shi +2 位作者 Jinyan Yan Yali Ge Haiyan Wei 《Open Journal of Anesthesiology》 2013年第4期249-254,共6页
Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studi... Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studied. Complete intravenous general anesthesia was used for induction and anesthesia maintenance. After anesthesia induction we put the TEE probe into the esophagus. The cardiac index was determined at three periods following MVR: T1 30 minutes later following cessation of bypass, T2 60 minutes after cessation of bypass, T3 90 minutes after cessation of bypass. Statistical analysis was made with the Bland and Altman method. Results: Ninety-six measurements were compared. The cardiac index values at the level of prosthesis mitral valve (CIMV) ranged from 1.3 to 5.5 L·min-1·m-2 (mean 2.6 ± 0.9). The Values of cardiac index at aortic valve (CIAA) ranged from 2.7 to8.8 L·min-1·m-2 (mean 4.9 ± 1.7). Bias was -2.3 L·min-1·m-2 and limits of agreement -5.6 to 1.0 L·min-1·m-2. Conclusion: During mitral valve replacement, doubtful correlations were observed between values of cardiac index at the mitral valve and the ascending aorta using TEE. 展开更多
关键词 CARDIAC Index CARDIAC Output transesophageal ECHOCARDIOGRAPHY MITRAL Valve REPLACEMENT Ascending AORTA
下载PDF
Natural orifice transesophageal thoracoscopic surgery:A review of the current state 被引量:1
3
作者 Brian G Turner Denise W Gee 《World Journal of Gastrointestinal Endoscopy》 CAS 2010年第1期3-9,共7页
Since the concept of Natural Orifice Translumenal Endoscopic Surgery(NOTES) was introduced,it has continued to gain significantly in popularity and enthusiasm for its potential clinical applications.The ability to per... Since the concept of Natural Orifice Translumenal Endoscopic Surgery(NOTES) was introduced,it has continued to gain significantly in popularity and enthusiasm for its potential clinical applications.The ability to perform conventional laparoscopic and thoracoscopic procedures without the creation of scars and perhaps faster and less painful recovery has prompted a worldwide devotion to further this field.While intraabdominal NOTES has rapidly transitioned from animal models to human trials,applying the NOTES concept to perform thoracic procedures has been slower to gain momentum.The goal of this review is to summarize the current state of transesophageal NOTES thoracoscopy by looking at its potential for diagnostic and therapeutic interventions as well as the challenges in transitioning to human trials. 展开更多
关键词 NATURAL ORIFICE translumenal endoscopic surgery transesophageal THORACOSCOPY MEDIASTINOSCOPY Esophagotomy NATURAL ORIFICE ENDOSCOPY
下载PDF
Upper gastrointestinal bleeding from a Mallory-Weiss tear associated with transesophageal echocardiography during successful cardiopulmonary resuscitation:A case report 被引量:1
4
作者 Miao-Miao Tang Deng-Feng Fang Bin Liu 《World Journal of Clinical Cases》 SCIE 2022年第9期2954-2960,共7页
BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59... BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59-year-old male patient scheduled to undergo cardiac surgery for rheumatic heart disease.Upper gastrointestinal bleeding from a Mallory-Weiss tear appeared following cardiopulmonary resuscitation,TEE,and percutaneous cardiopulmonary bypass resuscitation when he suffered from aesthesia-related cardiac arrest.Gastrointestinal injury was diagnosed promptly and treated effectively.However,the exact etiology of gastrointestinal injury was unclear;the interaction of closed-chest cardiac massage and the application of TEE may be involved as a most possible mechanism of injury.CONCLUSION Serious complications should be considered when TEE is used in patients with special pathophysiological conditions. 展开更多
关键词 transesophageal echocardiography Upper gastrointestinal bleeding Cardiopulmonary resuscitation Mallory-Weiss tear Percutaneous cardiopulmonary bypass resuscitation Case report
下载PDF
Research and Application of Transnasal Transesophageal Echocardiography Probe 被引量:1
5
作者 王蕾 张静 +4 位作者 郑少萍 贺林 王静 王新房 谢明星 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第5期782-786,共5页
The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed... The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience. During the examination, the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit(ICU), resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment. Two years ago, Prof. Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space. Later, Prof. Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect(ASD) patients and proved the safety and reliability of this method, which could become a new way for clinical diagnosis and treatment. 展开更多
关键词 transesophageal echocardiography atrial septal defect transthoracic echocardiography
下载PDF
Study on Three Dimensional Reconstruction of Transesophageal Echocardiographic Images 被引量:1
6
作者 李治安 王新房 +3 位作者 陆平 胡刚 郑莉慧 杨娅 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第1期10-15,共6页
Using biplane transesophageal echocardiography and the concept of three dimensional transthoracic echocardiography,we performed three dimensional reconstruction of transesophageal images of various clinicopathologic c... Using biplane transesophageal echocardiography and the concept of three dimensional transthoracic echocardiography,we performed three dimensional reconstruction of transesophageal images of various clinicopathologic cases,including atrial septal defect,mitral stenosis,mitral valve prolapse and pulmonary stenosis.The hardware equipments and image processing flow chart of three dimensional reconstruction of transesophageal echocardiographic images are described. Our present study indicates that three dimensional reconstruction of transesophageal echocardiographic images could display multi-regional three dimensional structures of heart and great vessels,including superior vena cava,ascending aorta,right ventricular outflow tract, pulmonary artery and left heart,with clear,visual and stereoscopic imaging.The regional structures could be displayed at different levels of stereo-anatomic-sec-tions and in different orientations of rotating stereo-images,which could provide accurate three dimensional anatomical information for cardiac stereo-morphological study and definition of spatial location and size of cardiac abnormalities. 展开更多
关键词 three-dimensional reconstruction transesophageal echocardiography(TEE) transthoracic echocardiography(TTE)
下载PDF
Role of intraoperative transesophageal echocardiography in coronary artery bypass grafting 被引量:1
7
作者 Xinchun Chen 《Journal of Nanjing Medical University》 2007年第1期1-7,共7页
Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means ... Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means of monitoring myocardial ischemia dur- ing coronary artery bypas grafting procedures. The cardiac anesthesiologist can apply intraoperative TEE in evaluating coronary artery anatomy and aorta atherosclerosis, assessing diastolic left ventricular function and preload,measuring intracardiac pressure and cardiac output,detecting ischaemic mitral regurgitation,intracardiac air and pericardial effusion. 展开更多
关键词 transesophageal echocardiography coronary artery bypass grafting ANESTHESIA mycardial ischemia cardiac output regional wall motion abnormality
下载PDF
Surgical Resection of Mitral Valve Papillary Fibroelastoma: A Robot-Assisted, Minimally Invasive Approach with Three-Dimensional Transesophageal Echocardiography Imaging 被引量:1
8
作者 Crystal R. Bonnichsen Harold M. Burkhart +1 位作者 Kyle W. Klarich Rakesh M. Suri 《World Journal of Cardiovascular Surgery》 2012年第2期10-13,共4页
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e... Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy. 展开更多
关键词 PAPILLARY FIBROELASTOMA ROBOTIC Surgery Three-Dimensional transesophageal ECHOCARDIOGRAPHY
下载PDF
Assessment of left atrial appendage function by transesophageal echocardiography in patients two weeks after acute coronary syndromes
9
作者 Grzegorz Piotrowski Zenon Gawor +1 位作者 Dariusz Timler Jozef Tazbir 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2005年第4期198-201,共4页
For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate left atrial... For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate left atrial appendage (LAA)function by means of biplane transesophageal echocardiography in patients ten days after acute coronary syndromes (ACS).Methods The study was performed on 16 adult patients (65.9±9.9 years old) in whom transesophageal echocardiography was done 10 days after ACS. The following left atrial appendage (LAA) planimetric parameters were analyzed: LAA transversal dimension, LAA longitudinal dimension,LAA maximal area, and LAA minimal area. LAA ejection fraction was calculated and analyzed. The following LAA Doppler parameters were analyzed: the peak LAA emptying and the peak LAA filling velocities.The control group consisted of 14 patients (43±14.6 years old) without cardiovascular diseases. Results Both LAA longitudinal dimension and LAA transversal dimension were significantly higher in patients with ACS than in control patients. The same was observed for LAA maximal area. Also LAA ejection fraction was higher in patients with ACS. LAA minimal area did not differ in the patients in either group. LAA peak emptying flow (LAAE) and LAA peak filling flow (LAAF) were significantly higher in patients of the study group than of the control group. Conclusion Our study shows that two weeks after acute coronary syndrome LAA as a reservoir as well as a pump works at a higher level than it does in the control group. 展开更多
关键词 LEFT ATRIAL appendage acute CORONARY SYNDROMES transesophageal ECHOCARDIOGRAPHY
下载PDF
Feasibility of percutaneous closure of left atrial appendage under the guidance of transesophageal echocardiography without fluoroscopy
10
作者 Mengxuan Zou Guangzhi Zhao +6 位作者 Wenbin Ouyang Fengwen Zhang Bin Wen Yongquan Xie Cheng Wang Yao Liu Xiangbin Pan 《中国循环杂志》 CSCD 北大核心 2018年第S01期138-138,共1页
Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guid... Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guidance of transesophageal echocardiography(TEE)without fluoroscopy. 展开更多
关键词 ATRIAL FIBRILLATION LEFT ATRIAL appendage transesophageal ECHOCARDIOGRAPHY
下载PDF
Transesophageal ultrasonography in assessment of operability for advanced esophageal carcinoma
11
作者 段云友 贺声 +4 位作者 曹铁生 张少玲 黄裕新 张广忖 程庆书 《Journal of Medical Colleges of PLA(China)》 CAS 1994年第4期294-297,共4页
TransesophagealultrasonographyinassessmentofoperabilityforadvancedesophagealcarcinomaDuanYunyou(段云友);HeSheng... TransesophagealultrasonographyinassessmentofoperabilityforadvancedesophagealcarcinomaDuanYunyou(段云友);HeSheng(贺声);CaoTiesheng(... 展开更多
关键词 transesophageal ULTRASONOGRAPHY ESOPHAGEAL NEOPLASMS operable ASSESSMENT
下载PDF
Clinical Application of Three-dimensional Transesophageal Echocardiography in the Diagnosis of Atrial Septal Defect
12
作者 郑俐慧 李治安 +3 位作者 王新房 胡纲 杨娅 刘俐 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第3期183-185,共3页
This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. ... This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. The size,shape and position of atrial septal defects could be showed clearly and the type of the defects could be identified. The reconstructed imaging of interatrial septum on 3-D TEE was clear and stereoscopic. The technique is helpful in defining spatial location and extent of atrial septal defects. 展开更多
关键词 THREE-DIMENSIONAL transesophageal echocardiography atrial septal Defect
下载PDF
Geometric comparison of the mitral and tricuspid valve annulus:Insights from three dimensional transesophageal echocardiography
13
作者 Amgad N Makaryus Haisam Ismail +1 位作者 John N Makaryus Dali Fan 《World Journal of Cardiology》 CAS 2017年第9期757-760,共4页
AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.MET... AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.METHODS Our retrospective cohort study examined the MVA and TVA in 49 patients by RT3 D TEE. MVA and TVA shape were examined by TEE. The MVA and TVA volume data set images were acquired in the mid esophageal 4-chamber view. The MVA and TVA were acquired separately, with optimization of each for the highest frame rate and image quality. The 3D shape of the annuli was reconstructed using the Philips~? Q lab, MVQ ver. 6.0 MVA model software. The end-systolic frame was used. The parameters measured and compared were annular area, circumference, high-low distances(height), anterolateralposterolateral(ALPM), and anteroposterior(AP) axes. RESULTS A total of 49 patients(mean age 61 ± 14 years, 45% males) were studied. The ALPM and the AP axes of the MVA and TVA are not significantly different. The ALPM axis of the MVA was 37.9 ± 6.4 mm and 38.0 ± 5.6 mm for the TVA(P = 0.70). The AP axis of the MVA was 34.8 ± 5.7 mm and 34.9 ± 6.2 mm for the TVA(P = 0.90). The MVA and the TVA had similar circumference and area. The circumference of the MVA was 127.9 ± 16.8 mm and 125.92 ± 16.12 mm for the TVA(P = 0.23). The area of the MVA was 1103.7 ± 307.8 mm^2 and 1131.7 ± 302.0 mm^2 for the TVA(P = 0.41). The MVA and TVA are similar oval structures, but with significantly different heights. The ALPM/AP ratio for the MVA was 1.08 ± 0.33 and 1.09 ± 0.28 for the TVA(P < 0.001). The height for the MVA and TVA was 9.23 ± 2.11 mm and 4.37 ± 1.48 mm, respectively(P < 0.0001). CONCLUSION RT3 D TEE plays an unprecedented role in the management of valvular heart disease. The specific and exclusive shape of the MVA and TVA was revealed in our study of patients studied. Moreover, the intricate codependence of the MVA and the TVA depends on their distinctive shapes. This realization seen from our study will allow us to better understand the role valvular disease plays in disease states such as hypertrophic cardiomyopathy and pulmonary hypertension. 展开更多
关键词 僧帽形的阀门体环 有三个尖头的阀门体环 三维的成像 实时三维的 transesophageal echocardiography
下载PDF
Is transesophageal echocardiography needed for evaluating tissue-based transient ischemic attack?
14
作者 Mohamed Al-Khaled Bjorn Scheef Toralf Brüning 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第7期1212-1215,共4页
Transient ischemic attack(TIA) is a warning signal for stroke.A comprehensive evaluation of TIA may reduce the risk for subsequent stroke.Data on the findings of cardiac evaluation with transesophageal echocardiogra... Transient ischemic attack(TIA) is a warning signal for stroke.A comprehensive evaluation of TIA may reduce the risk for subsequent stroke.Data on the findings of cardiac evaluation with transesophageal echocardiography(TEE) in patients with TIA are sparse.Our aims were to determine the frequency of TEE performance and to investigate the findings of TEE in patients with TIA based on the new definition of TIA(i.e.,transient neurological symptoms without evidence of infarction).During a 4-year period(2011–2014),1071 patients(mean age,70 ± 13 years;female,49.7%) with TIA were included in a prospective study and evaluated.Of 1071 consecutive patients suffering from TIA,288 patients(27%) underwent TEE.The median time between admission and TEE was 6 days.Patients with TIA who were evaluated by TEE were younger(67 vs.71 years,P 〈 0.001) than those who were not evaluated by TEE.They had a higher rate of sensibility disturbance as a TIA symptom(39% vs.31%,P = 0.012) but a lower rate of previous stroke(15% vs.25%,P = 0.001) and atrial fibrillation(2% vs.21%,P 〈 0.001) than those who did not.Foramen ovale was detected in 71 patients(25.7%),atrial septal aneurysm in 13 patients(4.6%),and severe atherosclerotic plaques(grade 4 and 5) in the aortic arch in 25 patients(8.7%).One patient(0.3%) had a fibroma detected by TEE.In 17 of the 288 patients(6%) who underwent TEE,the indication for anticoagulation therapy was based on the TEE results,and 1 patient with fibroma underwent heart surgery.During hospitalization,7 patients experienced a subsequent stroke,and 27 patients had a recurrent TIA.At 3 months following discharge,the rates of readmission,stroke,recurrent TIA,and death were 19%,2.7%,4.2%,and 1.6%,respectively.The rates of mortality(0.9% vs.1.8%,P = 0.7),stroke risk(1.9% vs.3.0%,P = 0.8),and recurrent TIA(5.0% vs.3.9%,P = 0.8) were similar in patients who underwent TEE and in those who did not.Performing TEE in patients with tissue-based TIA is helpful in detecting cardiac sources for embolism and may indicate for anticoagulation. 展开更多
关键词 transesophageal echocardiography transient ischemic stroke anticoagulation management therapy change
下载PDF
Assessment of Right Coronary Artery Fistula by Multiplane Transesophageal Echocardiography
15
作者 杨娅 王新房 李治安 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第3期186-189,共4页
Coronary artery fistula(CAF) is a relatively uncommon cardiovascular disease. It is an abnormal communication between a coronary artery and a cardiac chamber, great vessels, or other vascular structures. Most are cong... Coronary artery fistula(CAF) is a relatively uncommon cardiovascular disease. It is an abnormal communication between a coronary artery and a cardiac chamber, great vessels, or other vascular structures. Most are congenital. Multiplane transesophageal echocardiography(multiplane TEE. MTEE) can reveal the proximal dilation, the course and the drainage site of CAF. Presented in this paper was a report of right coronary artery-left ventricle fistula , for the first time,right coronary-left ventricle fistula diagnosed by MTEE and confirmed by angiography. 展开更多
关键词 coronary artery fistula multiplane transesophageal echocardiography
下载PDF
Atherosclerotic aortic plaques detected by transesophageal echocardiography
16
作者 赵云 朱文玲 +3 位作者 倪超 郭丽琳 曾勇 方理刚 《South China Journal of Cardiology》 CAS 2002年第1期46-50,共5页
Objective To evaluate the predictive value of atherosclerotic aortic plaques in coronary artery disease (CAD). Methods In 50 patients with suspected coronary artery disease, transesophageal echocardiography was perfor... Objective To evaluate the predictive value of atherosclerotic aortic plaques in coronary artery disease (CAD). Methods In 50 patients with suspected coronary artery disease, transesophageal echocardiography was performed to examine their thoracic aortas 2 weeks before or after coronary angiography. In the cases of coronary angiography studied, stenosis of the coronary artery ≥50%was considered to be due to coronary artery disease, whereas the thickness of the intima ≥1.3 mm was taken to be the criteria for the presence of an atherosclerotic aortic plaque on the transesophageal echocardiographic test. Results Among the 50 patients, 37 cases were diagnosed as CAD and 13 cases were considered to be normal. The plaques of the thoracic aorta were observed in 34 cases in the CAD group and 3 cases in the normal group. The sensitivity and specificity of aortic plaques for CAD were 91.9%and 76.9%, respectively. The positive and negative predictive values of the aortic plaques for CAD were 91.9%and 76.9%, respectively. The accuracy was 88.0%. 80 percent of the patients with single-vessel disease had thoracic aortic plaques, 92 percent of the patients with two vessel disease and 100 percent of the patients with three vessel disease had thoracic aortic plaques. There was a significant difference in the thickness of aortic intimas between the normal group and the CAD group. Conclusions Detecting atherosclerotic plaques in the thoracic aorta with transesophageal echocardiography may be of great value in predicting the presence and extent of coronary artery disease. 展开更多
关键词 Atherosclerotic aortic plaque transesophageal echocardiography Coronary artery disease
下载PDF
Evaluate of transesophageal echocardiography during lung transplantation
17
作者 吴雅峰 《外科研究与新技术》 2011年第3期158-158,共1页
Objective To investigate the clinical value of transesophageal echocardiography during the lung transplantation. Methods From August 2005 to August 2009, 19 patients with advanced lung diseases received lung transplan... Objective To investigate the clinical value of transesophageal echocardiography during the lung transplantation. Methods From August 2005 to August 2009, 19 patients with advanced lung diseases received lung transplantation. The average age was (48. 35 ± 13. 04) years. The echocardiographic probe was placed in patient’ s esophagus before surgery. The left and right 展开更多
关键词 LUNG Evaluate of transesophageal echocardiography during lung transplantation
下载PDF
Effects of sevoflurane on left ventricular function by speckletracking echocardiography in coronary bypass patients: A randomized trial
18
作者 Chanjuan Gong Xiaokai Zhou +3 位作者 Yin Fang Yanjuan Zhang Linjia Zhu Zhengnian Ding 《The Journal of Biomedical Research》 CAS CSCD 2024年第1期76-86,共11页
The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to ass... The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to assess the effect of sevoflurane on cardiac function.Sixty-four patients scheduled for the off-pump coronary artery bypass grafting were randomly divided into a sevoflurane-based anesthesia(AS)group and a propofolbased total intravenous anesthesia(AA)group.The AS group demonstrated a higher absolute value of left ventricular global longitudinal strain than that of the AA group at both T1(after harvesting all grafts and before coronary anastomosis)and T_(2)(30 min after completing all coronary anastomoses)(P<0.05).Moreover,strain improvement in the segment with the highest preoperative strain was significantly reduced in the AS group,compared with the AA group at both T1 and T_(2)(P<0.01).The flow of the left internal mammary artery-left anterior descending artery graft was superior,and the postoperative concentration of troponin T decreased rapidly in the AS group,compared with the AA group(P<0.05).Compared with total intravenous anesthesia,sevoflurane resulted in a significantly higher global longitudinal strain,stroke volume,and cardiac output.Sevoflurane also led to an amelioration in the condition of the arterial graft.Furthermore,sevoflurane significantly reduced strain improvement in the segmental myocardium with a high preoperative strain value.The findings need to be replicated in larger studies. 展开更多
关键词 coronary artery bypass grafting speckle-tracking echocardiography SEVOFLURANE transesophageal echocardiography
下载PDF
Tricuspid mass-curious case of Li-Fraumeni syndrome: A case report
19
作者 Tyler Huffaker Stella Pak +1 位作者 Anum Asif Prince Otchere 《World Journal of Clinical Cases》 SCIE 2024年第11期1936-1939,共4页
BACKGROUND Li-Fraumeni syndrome(LFS)is a rare autosomal dominant cancer-predisposing syndrome,which can manifest as a polymorphic spectrum of malignancies.LFS is associated with an early onset in life,with the majorit... BACKGROUND Li-Fraumeni syndrome(LFS)is a rare autosomal dominant cancer-predisposing syndrome,which can manifest as a polymorphic spectrum of malignancies.LFS is associated with an early onset in life,with the majority of cases occurring prior to the age of 46.Notwithstanding the infrequency of primary cardiac tumors,it behooves clinicians to remain vigilant in considering the differential diagnosis of such tumors in LFS patients who present with a cardiac mass.This is due to the markedly elevated risk for malignancy in this particular population,far surpassing that of the general populace.CASE SUMMARY Herein,we present a case of a 30-year-old female with LFS who was found to have a tricuspid valve leaflet mass.CONCLUSION This case exemplifies valuable learning points in the diagnostic approach for this exceptionally rare patient population. 展开更多
关键词 Li-Fraumeni syndrome Cardiac mass Intracardiac thrombus transesophageal echocardiogram Cardiac magnetic resonance imaging Case report
下载PDF
Comparison of cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transesophageal echocardiography vs. contrast agent injection 被引量:8
20
作者 Yuan-Jun Sun Xiao-Meng Yin +9 位作者 Tao Cong Lian-Jun Gao Dong Chang Xian-Jie Xiao Qiao-Bing Sun Rong-Feng Zhang Xiao-Hong Yu Ying-Xue Dong Yan-Zong Yang Yun-Long Xia 《Chinese Medical Journal》 SCIE CAS CSCD 2019年第3期285-293,共9页
Background:Pulmonary vein (PV) occlusion generally depends on repetitive contrast agent injection when cryoballoon ablation for atrial fibrillation (AF). The present study was to compare the effect of cryoballoon abla... Background:Pulmonary vein (PV) occlusion generally depends on repetitive contrast agent injection when cryoballoon ablation for atrial fibrillation (AF). The present study was to compare the effect of cryoballoon ablation for AF guided by transesophageal echocardiography (TEE) vs. contrast agent injection.Methods:Eighty patients with paroxysmal AF (PAF) were enrolled in the study. About 40 patients underwent cryoballoon ablation without TEE (non-TEE group) and the other 40 underwent cryoballoon ablation with TEE for PV occlusion (TEE group). In the TEE group during the procedure, PVs were displayed in 3-dimensional images to guide the balloon to achieve PV occlusion. The patients were followed up at regularly scheduled visits every 2 months.Results:No differences were identified between the groups in regard to the procedure time and cryoablation time for each PV. The fluoroscopy time (6.7±4.2 min vs. 17.9±5.9 min, P<0.05) and the amount of contrast agent (3.0±5.1 mL vs.18.1±3.4 mL, P<0.05) in the TEE group were both less than the non-TEE group. At a mean of 13.0±3.3 mon follow-up, success rates were similar between the TEE group and non-TEE group (77.5% vs. 80.0%, P=0.88).Conclusions:Cryoballoon ablation with TEE for occlusion of the PV is both safe and effective. Less fluoroscopy time and a lower contrast agent load can be achieved with the help of TEE for PV occlusion during procedure. 展开更多
关键词 ATRIAL FIBRILLATION CRYOBALLOON ablation Pulmonary VEINS Balloon occlusion transesophageal ECHOCARDIOGRAPHY
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部