We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
This paper proposed an improved temperature prediction model for oil-immersed transformer.The influences of the environmental temperature and heat-sinking capability changing with temperature were considered.When calc...This paper proposed an improved temperature prediction model for oil-immersed transformer.The influences of the environmental temperature and heat-sinking capability changing with temperature were considered.When calculating the heat dissipation from the transformer tank to surroundings,the average oil temperature was selected as the node value in the thermal circuit.The new thermal models will be validated with the delivery experimental data of three transformers: a 220 kV-300 MV.A unit,a 110 kV40 MV.A unit and a 220 kV-75 MV.A unit.Meanwhile,the results from the proposed model were also compared with two methods recommended in the IEC loading guide.展开更多
The advantages of the all-fiber optical current transformer include but are not limited to being small in size,having no magnetic saturation,exhibiting high measurement accuracy,and boasting strong electromagnetic int...The advantages of the all-fiber optical current transformer include but are not limited to being small in size,having no magnetic saturation,exhibiting high measurement accuracy,and boasting strong electromagnetic interference resistance.However,the high cost of the all-fiber optical transformer limits its promotion and application in engineering.This paper proposes a design scheme of an independent double acquisition loop for the all-fiber optical current transformer based on the single optical path.Firstly,based on the closed-loop control mode and open-loop control mode,the twochannel sampling signal demand for relay protection,and the independent dual-acquisition loop design scheme of the all-fiber optical current transformer are proposed.Secondly,the reliability and economic feasibility of the scheme are demonstrated by an analysis of system failure and cost.The results show that the scheme can actualize the acquisition function of two independent all-fiber optical current transformer products on a single all-fiber current transformer in an integrated manner,which greatly reduces the cost of the all-fiber optical current transformer in engineering applications.展开更多
The design of the insulated core transformer(ICT)needs to consider the flux leakage effects.An equivalent linear circuit model is proposed based on the principle of duality.It is composed by two types of leakage induc...The design of the insulated core transformer(ICT)needs to consider the flux leakage effects.An equivalent linear circuit model is proposed based on the principle of duality.It is composed by two types of leakage inductances:conventional leakage between windings and special leakage introduced mainly by the insulation gaps.The values of leakage inductances depend on the dimensions of the core,gaps,or windings and the property of magnetic materials.The circuit allows for quantitatively evaluating influences of ICT internal parameters on its output properties.The winding self- and mutual inductance matrix is mathematically converted to derive the inductance formula.As an example,the leakage parameters of a sixstage two-dimensional(2D) ICT are calculated and analyzed.展开更多
It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and ...It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and short-circuit impedance model of axial dual-low-voltage split-winding transformer is established, and then the 2D and 3D leakage magnetic field are analyzed. Secondly, the short-circuit impedance and split parallel branch current distribution in different working conditions are calculated, which is based on field-circuit coupled method. At last, effectiveness and feasibility of the proposed model is verified by comparison between experiment, analysis and simulation. The results showed that the 3D analysis method is a better approach to calculate the short-circuit impedance, since its analytical value is more closer to the experimental value compared with the 2D analysis results, the finite element method calculation error is less than 2%, while the leakage flux method maximum error is 7.2%.展开更多
This paper presents the modelling of transduction heaters using the TEC (transformer equivalent circuit) model and FEA (finite element analysis). Each model was used to simulate a set oftransduction heating experi...This paper presents the modelling of transduction heaters using the TEC (transformer equivalent circuit) model and FEA (finite element analysis). Each model was used to simulate a set oftransduction heating experiments and the results compared. Analysis of the TEC calculated results suggested modification of three parameters: the secondary resistance, the core tube eddy current resistance and the core tube magnetizing reactance. The improved TEC model was then used to design, build and test a 6 kW transduction heater. The measured results are compared with calculated results from the TEC and FEA models. The TEC model accurately predicts the performance of the heater.展开更多
The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination o...The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss.展开更多
文摘We review the short-circuit testing of distribution and power transformers, and include a list of 110-220kV power transformers tested up to February 2002.
文摘This paper proposed an improved temperature prediction model for oil-immersed transformer.The influences of the environmental temperature and heat-sinking capability changing with temperature were considered.When calculating the heat dissipation from the transformer tank to surroundings,the average oil temperature was selected as the node value in the thermal circuit.The new thermal models will be validated with the delivery experimental data of three transformers: a 220 kV-300 MV.A unit,a 110 kV40 MV.A unit and a 220 kV-75 MV.A unit.Meanwhile,the results from the proposed model were also compared with two methods recommended in the IEC loading guide.
基金supported by the National Natural Science Foundation of China (No. U1866203)
文摘The advantages of the all-fiber optical current transformer include but are not limited to being small in size,having no magnetic saturation,exhibiting high measurement accuracy,and boasting strong electromagnetic interference resistance.However,the high cost of the all-fiber optical transformer limits its promotion and application in engineering.This paper proposes a design scheme of an independent double acquisition loop for the all-fiber optical current transformer based on the single optical path.Firstly,based on the closed-loop control mode and open-loop control mode,the twochannel sampling signal demand for relay protection,and the independent dual-acquisition loop design scheme of the all-fiber optical current transformer are proposed.Secondly,the reliability and economic feasibility of the scheme are demonstrated by an analysis of system failure and cost.The results show that the scheme can actualize the acquisition function of two independent all-fiber optical current transformer products on a single all-fiber current transformer in an integrated manner,which greatly reduces the cost of the all-fiber optical current transformer in engineering applications.
基金supported by National Natural Science Foundation of China(No.11305068)the‘‘2011 project’’organized by Hubei Collaboration Innovation Center of Non-power Nuclear Technology
文摘The design of the insulated core transformer(ICT)needs to consider the flux leakage effects.An equivalent linear circuit model is proposed based on the principle of duality.It is composed by two types of leakage inductances:conventional leakage between windings and special leakage introduced mainly by the insulation gaps.The values of leakage inductances depend on the dimensions of the core,gaps,or windings and the property of magnetic materials.The circuit allows for quantitatively evaluating influences of ICT internal parameters on its output properties.The winding self- and mutual inductance matrix is mathematically converted to derive the inductance formula.As an example,the leakage parameters of a sixstage two-dimensional(2D) ICT are calculated and analyzed.
文摘It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and short-circuit impedance model of axial dual-low-voltage split-winding transformer is established, and then the 2D and 3D leakage magnetic field are analyzed. Secondly, the short-circuit impedance and split parallel branch current distribution in different working conditions are calculated, which is based on field-circuit coupled method. At last, effectiveness and feasibility of the proposed model is verified by comparison between experiment, analysis and simulation. The results showed that the 3D analysis method is a better approach to calculate the short-circuit impedance, since its analytical value is more closer to the experimental value compared with the 2D analysis results, the finite element method calculation error is less than 2%, while the leakage flux method maximum error is 7.2%.
文摘This paper presents the modelling of transduction heaters using the TEC (transformer equivalent circuit) model and FEA (finite element analysis). Each model was used to simulate a set oftransduction heating experiments and the results compared. Analysis of the TEC calculated results suggested modification of three parameters: the secondary resistance, the core tube eddy current resistance and the core tube magnetizing reactance. The improved TEC model was then used to design, build and test a 6 kW transduction heater. The measured results are compared with calculated results from the TEC and FEA models. The TEC model accurately predicts the performance of the heater.
文摘The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss.