In order to reduce the external magnetic field and improve the conversion efficiency of high-power microwave generation devices with low external magnetic field,a novel diode with an embedded soft magnetic and shieldi...In order to reduce the external magnetic field and improve the conversion efficiency of high-power microwave generation devices with low external magnetic field,a novel diode with an embedded soft magnetic and shielding structure is proposed.The soft magnetic material is designed to enhance the local magnetic field in the diode region.Moreover,the diode applies a shielding structure which can reduce the radial electric field.From simulation research,it is found that the emission and transmission quality of the electron beam with low magnetic field is greatly improved when loading this diode.Through simulation research,it is verified that the diode can increase the conversion efficiency of the transit-time oscillator(TTO)from 30%to 36.7%.In our experimental study,under the conditions of a diode voltage of 540 kV and a current of 10.5 kA,the output microwave power is 1.51 GW when loading the novel diode and the microwave frequency is 4.27 GHz when an external guiding magnetic field of 0.3 T is applied.The corresponding conversion efficiency is improved from 20.0%to 26.6%,which is 6.6%higher than that of a device loaded with a conventional diode.Our experiments have verified that this novel diode can effectively improve the conversion efficiency of high-power microwave sources operating with low magnetic field,and contribute to the miniaturization and compactness of high-power microwave devices.展开更多
Research progresses on Cherenkov and transit-time high-power microwave(HPM)sources in National University of Defense Technology(NUDT)of China are presented.The research issues are focused on the following aspects.The ...Research progresses on Cherenkov and transit-time high-power microwave(HPM)sources in National University of Defense Technology(NUDT)of China are presented.The research issues are focused on the following aspects.The pulse-shortening phenomenon in O-type Cerenkov HPM devices is suppressed.The compact coaxial relativistic backward-wave oscillators(RBWOs)at low bands are developed.The power efficiency in M-Type HPM tubes without guiding magnetic field increased.The power capacities and power efficiencies in the triaxial klystron amplifier(TKA)and relativistic transit-time oscillator(TTO)at higher frequencies increased.In experiments,some exciting results were obtained.The X-band source generated 2 GW microwave power with a pulse duration of 110 ns in 30 Hz repetition mode.Both L-and P-band compact RBWOs generated over 2 GW microwave power with a power efficiency of over 30%.There is approximately a 75% decline of the volume compared with that of conventional RBWO under the same power capacity conditions.A 1.755 GHz MILO produced 3.1 GW microwave power with power efficiency of 10.4%.A 9.37 GHz TKA produced the 240 MW microwave power with the gain of 34 dB.A 14.3 GHz TTO produced 1 GW microwave power with power efficiency of 20%.展开更多
According to the transit-time difference measurement method,we proposed a design scheme of ultrasonic heat meter based on TDC-GP21.The measurement unit TDC-GP21 mainly completes transit-time measurement and inlet,outl...According to the transit-time difference measurement method,we proposed a design scheme of ultrasonic heat meter based on TDC-GP21.The measurement unit TDC-GP21 mainly completes transit-time measurement and inlet,outlet temperature measurement functions.Control unit and data processing unit based on MSP430F4152 of TI corporation complete functions including peripherals control,data analysis,temperature compensation algorithm,flow pattern compensation algorithm and low power consumption control.The design meets the Town Construction Professional Standard CJ 128-2007,and furthermore,some performances can be improved.展开更多
Transit-time flow technology is considered as a quality of care in bypass surgery especially in off pump revascularization. Transit time flow measurement is a real time, direct, easy and handy tool for assessment qual...Transit-time flow technology is considered as a quality of care in bypass surgery especially in off pump revascularization. Transit time flow measurement is a real time, direct, easy and handy tool for assessment quality of anastomosis and graft blood flow.展开更多
The C-band three-cavity transit-time effect oscillator (3C TTTO) is a novel high power microwave device based on the transit-time effect of the three-cavity (3C) resonator. The operational principle of this device is ...The C-band three-cavity transit-time effect oscillator (3C TTTO) is a novel high power microwave device based on the transit-time effect of the three-cavity (3C) resonator. The operational principle of this device is briefly expounded in this paper, and the theoretical and experimental researches on the radial insulation diode, the 3C resonator, the double-gap output cavity and the circular waveguide bevel cut radiation antenna are presented in detail. By using the analytic method, the eigen modes and their field distributions of the 3C resonator are developed, and some basic laws of the transit-time effect are obtained in non-π mode field of the 3C resonator. At last, the experimental results are given. This device generated RF peak power in excess of 400MW with 15ns FWHM, and its beam-wave power conversion efficiency is about 17%.展开更多
目的研究蹲厕行为对胶囊内镜检查胃转运时间(gastric transit time,GTT)和全小肠检查率(complete examination rate of small bowel,CER)的影响。方法随机纳入2019年1-12月于重庆医科大学附属第二医院行胶囊内镜检查的患者122例,采用随...目的研究蹲厕行为对胶囊内镜检查胃转运时间(gastric transit time,GTT)和全小肠检查率(complete examination rate of small bowel,CER)的影响。方法随机纳入2019年1-12月于重庆医科大学附属第二医院行胶囊内镜检查的患者122例,采用随机数字表法将其分为试验组63例和对照组59例,试验组即吞服胶囊后随时可以蹲厕,对照组如需如厕采取坐便。比较2组患者GTT、小肠转运时间、CER和诊断率的区别。结果试验组和对照组患者在性别、年龄、住院情况等方面差异无统计学意义。试验组患者CER显著高于对照组(92.06%vs 79.66%),差异有统计学意义(P=0.048)。试验组患者中位GTT显著少于对照组(26.7 vs 45.6 min),差异有统计学意义(P=0.027)。两组患者在小肠转运时间和诊断率上差异无统计学意义。结论行胶囊内镜检查患者采用蹲厕行为能减少胶囊在胃内转运时间,增加全小肠检查率。展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No. 61701516)
文摘In order to reduce the external magnetic field and improve the conversion efficiency of high-power microwave generation devices with low external magnetic field,a novel diode with an embedded soft magnetic and shielding structure is proposed.The soft magnetic material is designed to enhance the local magnetic field in the diode region.Moreover,the diode applies a shielding structure which can reduce the radial electric field.From simulation research,it is found that the emission and transmission quality of the electron beam with low magnetic field is greatly improved when loading this diode.Through simulation research,it is verified that the diode can increase the conversion efficiency of the transit-time oscillator(TTO)from 30%to 36.7%.In our experimental study,under the conditions of a diode voltage of 540 kV and a current of 10.5 kA,the output microwave power is 1.51 GW when loading the novel diode and the microwave frequency is 4.27 GHz when an external guiding magnetic field of 0.3 T is applied.The corresponding conversion efficiency is improved from 20.0%to 26.6%,which is 6.6%higher than that of a device loaded with a conventional diode.Our experiments have verified that this novel diode can effectively improve the conversion efficiency of high-power microwave sources operating with low magnetic field,and contribute to the miniaturization and compactness of high-power microwave devices.
基金supported by the National Natural Science Funds Fund of China under Grant No.11505288Provincial Natural Science Foundation of Hunanscientific effort project of NUDT.
文摘Research progresses on Cherenkov and transit-time high-power microwave(HPM)sources in National University of Defense Technology(NUDT)of China are presented.The research issues are focused on the following aspects.The pulse-shortening phenomenon in O-type Cerenkov HPM devices is suppressed.The compact coaxial relativistic backward-wave oscillators(RBWOs)at low bands are developed.The power efficiency in M-Type HPM tubes without guiding magnetic field increased.The power capacities and power efficiencies in the triaxial klystron amplifier(TKA)and relativistic transit-time oscillator(TTO)at higher frequencies increased.In experiments,some exciting results were obtained.The X-band source generated 2 GW microwave power with a pulse duration of 110 ns in 30 Hz repetition mode.Both L-and P-band compact RBWOs generated over 2 GW microwave power with a power efficiency of over 30%.There is approximately a 75% decline of the volume compared with that of conventional RBWO under the same power capacity conditions.A 1.755 GHz MILO produced 3.1 GW microwave power with power efficiency of 10.4%.A 9.37 GHz TKA produced the 240 MW microwave power with the gain of 34 dB.A 14.3 GHz TTO produced 1 GW microwave power with power efficiency of 20%.
基金National Natural Science Foundation of China(No.61071087)Natural Science Foundation of Shandong Province(No.ZR2011FM018)
文摘According to the transit-time difference measurement method,we proposed a design scheme of ultrasonic heat meter based on TDC-GP21.The measurement unit TDC-GP21 mainly completes transit-time measurement and inlet,outlet temperature measurement functions.Control unit and data processing unit based on MSP430F4152 of TI corporation complete functions including peripherals control,data analysis,temperature compensation algorithm,flow pattern compensation algorithm and low power consumption control.The design meets the Town Construction Professional Standard CJ 128-2007,and furthermore,some performances can be improved.
文摘Transit-time flow technology is considered as a quality of care in bypass surgery especially in off pump revascularization. Transit time flow measurement is a real time, direct, easy and handy tool for assessment quality of anastomosis and graft blood flow.
文摘The C-band three-cavity transit-time effect oscillator (3C TTTO) is a novel high power microwave device based on the transit-time effect of the three-cavity (3C) resonator. The operational principle of this device is briefly expounded in this paper, and the theoretical and experimental researches on the radial insulation diode, the 3C resonator, the double-gap output cavity and the circular waveguide bevel cut radiation antenna are presented in detail. By using the analytic method, the eigen modes and their field distributions of the 3C resonator are developed, and some basic laws of the transit-time effect are obtained in non-π mode field of the 3C resonator. At last, the experimental results are given. This device generated RF peak power in excess of 400MW with 15ns FWHM, and its beam-wave power conversion efficiency is about 17%.
文摘目的研究蹲厕行为对胶囊内镜检查胃转运时间(gastric transit time,GTT)和全小肠检查率(complete examination rate of small bowel,CER)的影响。方法随机纳入2019年1-12月于重庆医科大学附属第二医院行胶囊内镜检查的患者122例,采用随机数字表法将其分为试验组63例和对照组59例,试验组即吞服胶囊后随时可以蹲厕,对照组如需如厕采取坐便。比较2组患者GTT、小肠转运时间、CER和诊断率的区别。结果试验组和对照组患者在性别、年龄、住院情况等方面差异无统计学意义。试验组患者CER显著高于对照组(92.06%vs 79.66%),差异有统计学意义(P=0.048)。试验组患者中位GTT显著少于对照组(26.7 vs 45.6 min),差异有统计学意义(P=0.027)。两组患者在小肠转运时间和诊断率上差异无统计学意义。结论行胶囊内镜检查患者采用蹲厕行为能减少胶囊在胃内转运时间,增加全小肠检查率。