期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Turbidity measurement based on a multi-wavelength spectral sensor
1
作者 SHENG Tao XU Wenyan +1 位作者 SHI Shengzhe LIU Sheng 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第2期147-155,共9页
A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software.... A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software.Combining multiple wavelength data from the sensor,the unitary and multivariate fitting models were constructed to investigate the relationship among light intensity information,absorbance and turbidity,respectively.The turbidity of the actual water bodies was measured separately by using proposed method and a commercially visible spectrophotometer.The independent-samples T test(p>0.05)showed that there was no significant difference between the method in this paper and the standard assay method.The method is simple and inexpensive,and can be applied to the rapid detection of water turbidity,providing a new way of industrial online measurement. 展开更多
关键词 turbidity measurement MULTI-WAVELENGTH multi-fitting multichannel spectral sensor SPECTROPHOTOMETRY
下载PDF
Turbidity analysis using visible and near-infrared light images 被引量:2
2
作者 ZHU Yuanyang ZHAO Wenzhu +1 位作者 LIU Sheng GAO Hongwen 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2021年第1期27-35,共9页
The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a ... The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a camera is proposed by combining the imaging characteristics of a digital camera and the high-speed information processing capability of a computer.Two turbidity measurement devices based on visible and near-infrared(NIR)light cameras and a light source driving circuit with constant light intensity were designed.The RGB data in the turbidity images were acquired using a self-developed image processing software and converted to the CIE Lab color space.Based on the relationship between the luminance,chromatic aberration,and turbidity,the turbidity detection models for luminance and chromatic aberration of visible and NIR light devices exhibiting values from 0-1000 NTU,less than 100 NTU,and more than 100 NTU were established.By comparing and analyzing the proposed models,the two measurement models with the best all-around performance were selected and fused to generate new measurement models.The experimental results prove that the correlation between the three models and the commercial turbidity meter measurements exhibite a significance value higher than 0.999.The error of the fusion model is within 1.05%,with a mean square error of 1.14.The visible light device has less error at low turbidity measurements and is less influenced by the color of the image.The NIR light device is more stable and accurate at full range and high turbidity measurements and is therefore more suitable for such measurements. 展开更多
关键词 image processing water quality turbidity measurement near-infrared image color space conversion
下载PDF
Evaluation of Influence of Multiple Scattering Effect in Light-Scattering-Based Applications
3
作者 徐升华 孙祉伟 《Chinese Physics Letters》 SCIE CAS CSCD 2007年第6期1763-1766,共4页
The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The neces... The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles. 展开更多
关键词 T-MATRIX METHOD COLLOIDAL STABILITY turbidity measurement MICROSCOPICAPPROACH RATE CONSTANTS COAGULATION INDEX
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部