A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software....A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software.Combining multiple wavelength data from the sensor,the unitary and multivariate fitting models were constructed to investigate the relationship among light intensity information,absorbance and turbidity,respectively.The turbidity of the actual water bodies was measured separately by using proposed method and a commercially visible spectrophotometer.The independent-samples T test(p>0.05)showed that there was no significant difference between the method in this paper and the standard assay method.The method is simple and inexpensive,and can be applied to the rapid detection of water turbidity,providing a new way of industrial online measurement.展开更多
The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a ...The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a camera is proposed by combining the imaging characteristics of a digital camera and the high-speed information processing capability of a computer.Two turbidity measurement devices based on visible and near-infrared(NIR)light cameras and a light source driving circuit with constant light intensity were designed.The RGB data in the turbidity images were acquired using a self-developed image processing software and converted to the CIE Lab color space.Based on the relationship between the luminance,chromatic aberration,and turbidity,the turbidity detection models for luminance and chromatic aberration of visible and NIR light devices exhibiting values from 0-1000 NTU,less than 100 NTU,and more than 100 NTU were established.By comparing and analyzing the proposed models,the two measurement models with the best all-around performance were selected and fused to generate new measurement models.The experimental results prove that the correlation between the three models and the commercial turbidity meter measurements exhibite a significance value higher than 0.999.The error of the fusion model is within 1.05%,with a mean square error of 1.14.The visible light device has less error at low turbidity measurements and is less influenced by the color of the image.The NIR light device is more stable and accurate at full range and high turbidity measurements and is therefore more suitable for such measurements.展开更多
The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The neces...The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles.展开更多
基金National Natural Science Foundation of China(No.71801108)Natural Science Fund for Colleges and Universities of Anhui Province(No.KJ2017ZD32)。
文摘A method of measuring turbidity based on a multi-wavelength spectral sensor is proposed by using SFH4737 broad-band infrared LED,a multi-wavelength spectral sensor and independently developed data processing software.Combining multiple wavelength data from the sensor,the unitary and multivariate fitting models were constructed to investigate the relationship among light intensity information,absorbance and turbidity,respectively.The turbidity of the actual water bodies was measured separately by using proposed method and a commercially visible spectrophotometer.The independent-samples T test(p>0.05)showed that there was no significant difference between the method in this paper and the standard assay method.The method is simple and inexpensive,and can be applied to the rapid detection of water turbidity,providing a new way of industrial online measurement.
基金National Natural Science Foundation of China(No.61671434)Key Projects of Provincial Natural Science Foundation of Anhui Universities(Nos.KJ2019A0952,KJ2017ZD32)。
文摘The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a camera is proposed by combining the imaging characteristics of a digital camera and the high-speed information processing capability of a computer.Two turbidity measurement devices based on visible and near-infrared(NIR)light cameras and a light source driving circuit with constant light intensity were designed.The RGB data in the turbidity images were acquired using a self-developed image processing software and converted to the CIE Lab color space.Based on the relationship between the luminance,chromatic aberration,and turbidity,the turbidity detection models for luminance and chromatic aberration of visible and NIR light devices exhibiting values from 0-1000 NTU,less than 100 NTU,and more than 100 NTU were established.By comparing and analyzing the proposed models,the two measurement models with the best all-around performance were selected and fused to generate new measurement models.The experimental results prove that the correlation between the three models and the commercial turbidity meter measurements exhibite a significance value higher than 0.999.The error of the fusion model is within 1.05%,with a mean square error of 1.14.The visible light device has less error at low turbidity measurements and is less influenced by the color of the image.The NIR light device is more stable and accurate at full range and high turbidity measurements and is therefore more suitable for such measurements.
基金Supported by the National Natural Science Foundation of China under Grand Nos 10672173 and 10332050, and the China Postdoctoral Science Foundation.
文摘The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles.