BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby provi...BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby providing patients with better treatment outcomes and quality of life.Nonetheless,this surgical technique also presents some challenges and limitations.Therefore,three-dimensional reconstruction visualization technology(3D RVT)has been introduced into the procedure,providing doctors with more comprehensive and intuitive anatomical information that helps with surgical planning,navigation,and outcome evaluation.AIM To discuss the application and advantages of 3D RVT in precise laparoscopic resection of EGJ carcinomas.METHODS Data were obtained from the electronic or paper-based medical records at The First Affiliated Hospital of Hebei North University from January 2020 to June 2022.A total of 120 patients diagnosed with EGJ carcinoma were included in the study.Of these,68 underwent laparoscopic resection after computed tomography(CT)-enhanced scanning and were categorized into the 2D group,whereas 52 underwent laparoscopic resection after CT-enhanced scanning and 3D RVT and were categorized into the 3D group.This study had two outcome measures:the deviation between tumor-related factors(such as maximum tumor diameter and infiltration length)in 3D RVT and clinical reality,and surgical outcome indicators(such as operative time,intraoperative blood loss,number of lymph node dissections,R0 resection rate,postoperative hospital stay,postoperative gas discharge time,drainage tube removal time,and related complications)between the 2D and 3D groups.RESULTS Among patients included in the 3D group,27 had a maximum tumor diameter of less than 3 cm,whereas 25 had a diameter of 3 cm or more.In actual surgical observations,24 had a diameter of less than 3 cm,whereas 28 had a diameter of 3 cm or more.The findings were consistent between the two methods(χ^(2)=0.346,P=0.556),with a kappa consistency coefficient of 0.808.With respect to infiltration length,in the 3D group,23 patients had a length of less than 5 cm,whereas 29 had a length of 5 cm or more.In actual surgical observations,20 cases had a length of less than 5 cm,whereas 32 had a length of 5 cm or more.The findings were consistent between the two methods(χ^(2)=0.357,P=0.550),with a kappa consistency coefficient of 0.486.Pearson correlation analysis showed that the maximum tumor diameter and infiltration length measured using 3D RVT were positively correlated with clinical observations during surgery(r=0.814 and 0.490,both P<0.05).The 3D group had a shorter operative time(157.02±8.38 vs 183.16±23.87),less intraoperative blood loss(83.65±14.22 vs 110.94±22.05),and higher number of lymph node dissections(28.98±2.82 vs 23.56±2.77)and R0 resection rate(80.77%vs 61.64%)than the 2D group.Furthermore,the 3D group had shorter hospital stay[8(8,9)vs 13(14,16)],time to gas passage[3(3,4)vs 4(5,5)],and drainage tube removal time[4(4,5)vs 6(6,7)]than the 2D group.The complication rate was lower in the 3D group(11.54%)than in the 2D group(26.47%)(χ^(2)=4.106,P<0.05).CONCLUSION Using 3D RVT,doctors can gain a more comprehensive and intuitive understanding of the anatomy and related lesions of EGJ carcinomas,thus enabling more accurate surgical planning.展开更多
Gallium nitride(Ga N)-based high electron mobility transistors(HEMTs)that work in aerospace are exposed to particles radiation,which can cause the degradation in electrical performance.We investigate the effect of pro...Gallium nitride(Ga N)-based high electron mobility transistors(HEMTs)that work in aerospace are exposed to particles radiation,which can cause the degradation in electrical performance.We investigate the effect of proton irradiation on the concentration of two-dimensional electron gas(2 DEG)in Ga N-based HEMTs.Coupled Schr¨odinger’s and Poisson’s equations are solved to calculate the band structure and the concentration of 2 DEG by the self-consistency method,in which the vacancies caused by proton irradiation are taken into account.Proton irradiation simulation for Ga N-based HEMT is carried out using the stopping and range of ions in matter(SRIM)simulation software,after which a theoretical model is established to analyze how proton irradiation affects the concentration of 2 DEG.Irradiated by protons with high fluence and low energy,a large number of Ga vacancies appear inside the device.The results indicate that the ionized Ga vacancies in the Ga N cap layer and the Al Ga N layer will affect the Fermi level,while the Ga vacancies in the Ga N layer will trap the two-dimensional electrons in the potential well.Proton irradiation significantly reduced the concentration of 2 DEG by the combined effect of these two mechanisms.展开更多
Objective To evaluate the feasibility of using a low concentration of contrast medium (Visipaque 270 mgl/mL), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography ang...Objective To evaluate the feasibility of using a low concentration of contrast medium (Visipaque 270 mgl/mL), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography angiography (CTA). Methods Forty patients (22 men and 18 women; average age 48.7 ± 14.25 years; average body mass index 23.9 ± 3.7 kg/m^2) undergoing CTA for suspected vascular diseases were randomly assigned into two groups. Group A (n = 20) was administered 370 mgl/mL contrast medium, and group B (n = 20) was administered 270 mgl/mL contrast medium. Both groups were administered at a rate of 4.8 mL/s and an injection volume of 0.8 mL/kg. Images of group A were obtained with 120 kVp and filtered back projection (FBP) reconstruction, whereas images of group B were obtained with 80 kVp and 80% adaptive iterative statistical reconstruction algorithm (ASiR). The CT values and standard deviations of intracranial arteries and image noise on the corona radiata were measured to calculate the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). The beam-hardening artifacts (BHAs) around the skull base were calculated. Two readers evaluated the image quality with volume rendered images using scores from 1 to 5. The values between the two groups were statistically compared. Results The mean CT value of the intracranial arteries in group B was significantly higher than that in group A (P 〈 0.001). The CNR and SNR values in group B were also statistically higher than those in group A (P 〈 0.001). Image noise and BHAs were not significantly different between the two groups. The image quality score of VR images of in group B was significantly higher than that in group A (P = 0.001). However, the quality scores of axial enhancement images in group B became significantly smaller than those in group A (P〈 0.001). The CT dose index volume and dose-length product were decreased by 63.8% and 64%, respectively, in group B (P 〈 0.001 for both). Conclusion Visipaque combined with 80 kVp and 80% ASiR provided similar image quality in intracranial CTA with 64% radiation dose reduction compared with the use of lopamidol, 120 kVp, and FBP reconstruc-tion.展开更多
The annual series of δ13C were measured in tree rings of three Cryptomeria fortunei disks (OF-1, OF-2, and OF- 3) collected from West Tianmu Mountain, Zhejiang Province, China, according to cross-dating tree ring a...The annual series of δ13C were measured in tree rings of three Cryptomeria fortunei disks (OF-1, OF-2, and OF- 3) collected from West Tianmu Mountain, Zhejiang Province, China, according to cross-dating tree ring ages. There was no obvious decreasing trend of the δ13C annual time series of CF-2 before 1835. However, from 1835 to 1982 the three tree ring δ13C annual series exhibited similar decreasing trends that were significantly (P ≤ 0.001) correlated. The distribution characteristics of a scatter diagram between estimated δ13C series of CF-2 from modeling and the atmospheric CO2 concentration extracted from the Law Dome ice core from 1840 to 1978 were analyzed and a curvilinear regression equation for reconstructing atmospheric CO2 concentration was established with R2 = 0.98. Also, a test of independent samples indicated that between 1685 and 1839 the reconstructed atmospheric CO2 concentration .using the δ13C series of CF-2 had a close relationship with the Law Dome and Siple ice cores, with a standard deviation of 1.98. The general increasing trend of the reconstructed atmospheric CO2 concentration closely reflected the 10ng-term variation of atmospheric CO2 concentration recorded both before and after the Industrial Revolution. Between 1685 and 1840 the evaluated atmospheric CO2 concentration was stable, but after 1840 it exhibited a rapid increase. Given a longer δ13C annual time series of tree rings, it was feasible to rebuild a representative time series to describe the atmospheric CO2 concentration for an earlier period and for years that were not in the ice core record.展开更多
The Green function on two-phase saturated medium by concentrated force has a broad and important use In seismology, seismic engineering, soil mechanics, geophysics, dynamic foundation theory and so on. According to th...The Green function on two-phase saturated medium by concentrated force has a broad and important use In seismology, seismic engineering, soil mechanics, geophysics, dynamic foundation theory and so on. According to the Green function on two-phase saturated medium by concentrated force in three-dimentional displacement field obtained by Ding Bo-yang et al., it gives out the Green function in two-dimensional displacement field by infinite integral method along x(3)-direction derived by De Hoop and Manolis. The method adopted in the thesis is simpler. The result will be simplified to the boundary element method of dynamic problem.展开更多
Chlorophyll a concentration(CHL)is an important proxy of the marine ecological environment and phytoplankton production.Long-term trends in CHL of the South China Sea(SCS)reflect the changes in the ecosystem’s produc...Chlorophyll a concentration(CHL)is an important proxy of the marine ecological environment and phytoplankton production.Long-term trends in CHL of the South China Sea(SCS)reflect the changes in the ecosystem’s productivity and functionality in the regional carbon cycle.In this study,we applied a previously reconstructed 15-a(2005–2019)CHL product,which has a complete coverage at 4 km and daily resolutions,to analyze the long-term trends of CHL in the SCS.Quantile regression was used to elaborate on the long-term trends of high,median,and low CHL values,as an extended method of conventional linear regression.The results showed downward trends of the SCS CHL for the 75th,50th,and 25th quantile in the past 15 a,which were−0.0040 mg/(m^(3)·a)(−1.62%per year),−0.0023 mg/(m^(3)·a)(−1.10%per year),and−0.0019 mg/(m^(3)·a)(−1.01%per year).The negative trends in winter(November to March)were more prominent than those in summer(May to September).In terms of spatial distribution,the downward trend was more significant in regions with higher CHL.These led to a reduced standard deviation of CHL over time and space.We further explored the influence of various dynamic factors on CHL trends for the entire SCS and two typical systems(winter Luzon Strait(LZ)and summer Vietnam Upwelling System(SV))with single-variate linear regression and multivariate Random Forest analysis.The multivariate analysis suggested the CHL trend pattern can be best explained by the trends of wind speed and mixed-layer depth.The divergent importance of controlling factors for LZ and SV can explain the different CHL trends for the two systems.This study expanded our understanding of the long-term changes of CHL in the SCS and provided a reference for investigating changes in the marine ecosystem.展开更多
AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with ...AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction(SAFIRE?) in comparison with a standard MDCT protocol. Fiftythree consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/m L(Accupaque 350~?) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively(SAFIRE?-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio(CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups.RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol(P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different(P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group(P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups(P = 0.9926).CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality.展开更多
The fatigue performance of a workpiece depends on its surface quality.In traditional fatigue life prediction,the effect of surface quality is commonly accounted for by using empirical correction factors,which is impre...The fatigue performance of a workpiece depends on its surface quality.In traditional fatigue life prediction,the effect of surface quality is commonly accounted for by using empirical correction factors,which is imprecise when safety is of great concern.For surface quality,the surface topography is an important parameter,which introduces stress concentration that reduces the fatigue life.It is not feasible to test the stress concentration of different surface topographies.On the one hand,it is time-consuming and high-cost,and on the other hand,it cannot reflect the general statistical characteristics.With the help of surface reconstruction technology and interpolation method,a more efficient and economic approach is proposed,where FE simulation of workpiece with the reconstructed surface topography is used as a foundation for fatigue life prediction.The relationship between surface roughness(Sa)and fatigue life of the workpiece is studied with the proposed approach.展开更多
OSAHS(Obstructive Sleep Apnea Hypopnea Syndrome)is a respiratory disease mainly characterized by limited and repeated pauses of breathing in sleep.Currently,the optimal treatment is to apply CPAP(Continuous Positive A...OSAHS(Obstructive Sleep Apnea Hypopnea Syndrome)is a respiratory disease mainly characterized by limited and repeated pauses of breathing in sleep.Currently,the optimal treatment is to apply CPAP(Continuous Positive Airway Pressure)ventilation on the upper airway of the patient through a household respiratory machine.However,if the ventilator mask is designed improperly,it might cause the residue and repeated inhalation of CO2,which will exert an adverse impact on the therapeutic effect.Present research numerically analyzed the CO2 transportation inside a commercial ventilator mask(Mirage SoftGel,ResMed,Australia)based on the reconstructed 3D numerical model of a volunteer's face and performed the improved design of the ventilator mask in terms of the CO2 residual concentration below the nostrils.The fluid dynamic analyses showed that at the end time of expiratory,the CO2 residual concentration below the nostrils is close to 4%.To improve the therapeutic effect,we changed the position of the exhaust holes and found that by moving the exhaust holes to the bottom of the ventilator mask,the CO2 residual concentration below the nostrils would be reduced to no more than 1%.This study established a near physiological computational model and provided a new method for the individualized design of the commercial ventilator mask.展开更多
This paper constructs a concentric ellipsoid torso-heart model by boundary element method and investigates the impacts of model structures on the cardiac magnetic fields generated by both equivalent primary source--a ...This paper constructs a concentric ellipsoid torso-heart model by boundary element method and investigates the impacts of model structures on the cardiac magnetic fields generated by both equivalent primary source--a current dipole and volume currents. Then by using the simulated magnetic fields based on torso-heart model as input, the cardiac current sources--an array of current dipoles by optimal constrained linear inverse method are constructed. Next, the current dipole array reconstruction considering boundaries is compared with that in an unbounded homogeneous medium. Furthermore, the influence of random noise on reconstruction is also considered and the reconstructing effect is judged by several reconstructing parameters.展开更多
Two-dimensional(2 D) materials attracted substantial attention due to their extraordinary physical properties resulting from the unique atomic thickness. 2 D materials could be considered as material systems with flat...Two-dimensional(2 D) materials attracted substantial attention due to their extraordinary physical properties resulting from the unique atomic thickness. 2 D materials could be considered as material systems with flat surfaces at both sides, while the van der Waals gap is a natural out-of-plane interface between two monolayers. However, defects are inevitably presented and often cause significant surface and interface reconstruction, which modify the physical properties of the materials being investigated. In this review article, we reviewed the effort achieved in probing the defect structures and the reconstruction of surface and interface in novel 2 D materials through aberration corrected low voltage scanning transmission electron microscopy(LVSTEM). The LVSTEM technique enables us to unveil the intrinsic atomic structure of defects atom-by-atom, and even directly visualize the dynamical reconstruction process with single atom precision. The effort in understanding the defect structures and their contributions in the surface and interface reconstructions in 2 D materials shed light on the origin of their novel physical phenomenon, and also pave the way for defect engineering in future potential applications.展开更多
文摘BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby providing patients with better treatment outcomes and quality of life.Nonetheless,this surgical technique also presents some challenges and limitations.Therefore,three-dimensional reconstruction visualization technology(3D RVT)has been introduced into the procedure,providing doctors with more comprehensive and intuitive anatomical information that helps with surgical planning,navigation,and outcome evaluation.AIM To discuss the application and advantages of 3D RVT in precise laparoscopic resection of EGJ carcinomas.METHODS Data were obtained from the electronic or paper-based medical records at The First Affiliated Hospital of Hebei North University from January 2020 to June 2022.A total of 120 patients diagnosed with EGJ carcinoma were included in the study.Of these,68 underwent laparoscopic resection after computed tomography(CT)-enhanced scanning and were categorized into the 2D group,whereas 52 underwent laparoscopic resection after CT-enhanced scanning and 3D RVT and were categorized into the 3D group.This study had two outcome measures:the deviation between tumor-related factors(such as maximum tumor diameter and infiltration length)in 3D RVT and clinical reality,and surgical outcome indicators(such as operative time,intraoperative blood loss,number of lymph node dissections,R0 resection rate,postoperative hospital stay,postoperative gas discharge time,drainage tube removal time,and related complications)between the 2D and 3D groups.RESULTS Among patients included in the 3D group,27 had a maximum tumor diameter of less than 3 cm,whereas 25 had a diameter of 3 cm or more.In actual surgical observations,24 had a diameter of less than 3 cm,whereas 28 had a diameter of 3 cm or more.The findings were consistent between the two methods(χ^(2)=0.346,P=0.556),with a kappa consistency coefficient of 0.808.With respect to infiltration length,in the 3D group,23 patients had a length of less than 5 cm,whereas 29 had a length of 5 cm or more.In actual surgical observations,20 cases had a length of less than 5 cm,whereas 32 had a length of 5 cm or more.The findings were consistent between the two methods(χ^(2)=0.357,P=0.550),with a kappa consistency coefficient of 0.486.Pearson correlation analysis showed that the maximum tumor diameter and infiltration length measured using 3D RVT were positively correlated with clinical observations during surgery(r=0.814 and 0.490,both P<0.05).The 3D group had a shorter operative time(157.02±8.38 vs 183.16±23.87),less intraoperative blood loss(83.65±14.22 vs 110.94±22.05),and higher number of lymph node dissections(28.98±2.82 vs 23.56±2.77)and R0 resection rate(80.77%vs 61.64%)than the 2D group.Furthermore,the 3D group had shorter hospital stay[8(8,9)vs 13(14,16)],time to gas passage[3(3,4)vs 4(5,5)],and drainage tube removal time[4(4,5)vs 6(6,7)]than the 2D group.The complication rate was lower in the 3D group(11.54%)than in the 2D group(26.47%)(χ^(2)=4.106,P<0.05).CONCLUSION Using 3D RVT,doctors can gain a more comprehensive and intuitive understanding of the anatomy and related lesions of EGJ carcinomas,thus enabling more accurate surgical planning.
基金Project supported by the National Natural Science Foundation of China(Grant No.61874108)the Gansu Province Natural Science Foundation,China(Grant Nos.18JR3RA285 and 20JR5RA287)the Fundamental Research Funds for the Central Universities,China(Grant Nos.lzujbky-2020-kb06 and lzujbky-2020-cd02)。
文摘Gallium nitride(Ga N)-based high electron mobility transistors(HEMTs)that work in aerospace are exposed to particles radiation,which can cause the degradation in electrical performance.We investigate the effect of proton irradiation on the concentration of two-dimensional electron gas(2 DEG)in Ga N-based HEMTs.Coupled Schr¨odinger’s and Poisson’s equations are solved to calculate the band structure and the concentration of 2 DEG by the self-consistency method,in which the vacancies caused by proton irradiation are taken into account.Proton irradiation simulation for Ga N-based HEMT is carried out using the stopping and range of ions in matter(SRIM)simulation software,after which a theoretical model is established to analyze how proton irradiation affects the concentration of 2 DEG.Irradiated by protons with high fluence and low energy,a large number of Ga vacancies appear inside the device.The results indicate that the ionized Ga vacancies in the Ga N cap layer and the Al Ga N layer will affect the Fermi level,while the Ga vacancies in the Ga N layer will trap the two-dimensional electrons in the potential well.Proton irradiation significantly reduced the concentration of 2 DEG by the combined effect of these two mechanisms.
文摘Objective To evaluate the feasibility of using a low concentration of contrast medium (Visipaque 270 mgl/mL), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography angiography (CTA). Methods Forty patients (22 men and 18 women; average age 48.7 ± 14.25 years; average body mass index 23.9 ± 3.7 kg/m^2) undergoing CTA for suspected vascular diseases were randomly assigned into two groups. Group A (n = 20) was administered 370 mgl/mL contrast medium, and group B (n = 20) was administered 270 mgl/mL contrast medium. Both groups were administered at a rate of 4.8 mL/s and an injection volume of 0.8 mL/kg. Images of group A were obtained with 120 kVp and filtered back projection (FBP) reconstruction, whereas images of group B were obtained with 80 kVp and 80% adaptive iterative statistical reconstruction algorithm (ASiR). The CT values and standard deviations of intracranial arteries and image noise on the corona radiata were measured to calculate the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). The beam-hardening artifacts (BHAs) around the skull base were calculated. Two readers evaluated the image quality with volume rendered images using scores from 1 to 5. The values between the two groups were statistically compared. Results The mean CT value of the intracranial arteries in group B was significantly higher than that in group A (P 〈 0.001). The CNR and SNR values in group B were also statistically higher than those in group A (P 〈 0.001). Image noise and BHAs were not significantly different between the two groups. The image quality score of VR images of in group B was significantly higher than that in group A (P = 0.001). However, the quality scores of axial enhancement images in group B became significantly smaller than those in group A (P〈 0.001). The CT dose index volume and dose-length product were decreased by 63.8% and 64%, respectively, in group B (P 〈 0.001 for both). Conclusion Visipaque combined with 80 kVp and 80% ASiR provided similar image quality in intracranial CTA with 64% radiation dose reduction compared with the use of lopamidol, 120 kVp, and FBP reconstruc-tion.
基金Project supported by the National Natural Science Foundation of China (No. 49771001).
文摘The annual series of δ13C were measured in tree rings of three Cryptomeria fortunei disks (OF-1, OF-2, and OF- 3) collected from West Tianmu Mountain, Zhejiang Province, China, according to cross-dating tree ring ages. There was no obvious decreasing trend of the δ13C annual time series of CF-2 before 1835. However, from 1835 to 1982 the three tree ring δ13C annual series exhibited similar decreasing trends that were significantly (P ≤ 0.001) correlated. The distribution characteristics of a scatter diagram between estimated δ13C series of CF-2 from modeling and the atmospheric CO2 concentration extracted from the Law Dome ice core from 1840 to 1978 were analyzed and a curvilinear regression equation for reconstructing atmospheric CO2 concentration was established with R2 = 0.98. Also, a test of independent samples indicated that between 1685 and 1839 the reconstructed atmospheric CO2 concentration .using the δ13C series of CF-2 had a close relationship with the Law Dome and Siple ice cores, with a standard deviation of 1.98. The general increasing trend of the reconstructed atmospheric CO2 concentration closely reflected the 10ng-term variation of atmospheric CO2 concentration recorded both before and after the Industrial Revolution. Between 1685 and 1840 the evaluated atmospheric CO2 concentration was stable, but after 1840 it exhibited a rapid increase. Given a longer δ13C annual time series of tree rings, it was feasible to rebuild a representative time series to describe the atmospheric CO2 concentration for an earlier period and for years that were not in the ice core record.
文摘The Green function on two-phase saturated medium by concentrated force has a broad and important use In seismology, seismic engineering, soil mechanics, geophysics, dynamic foundation theory and so on. According to the Green function on two-phase saturated medium by concentrated force in three-dimentional displacement field obtained by Ding Bo-yang et al., it gives out the Green function in two-dimensional displacement field by infinite integral method along x(3)-direction derived by De Hoop and Manolis. The method adopted in the thesis is simpler. The result will be simplified to the boundary element method of dynamic problem.
基金The National Natural Science Foundation of China under contract No.41906019.
文摘Chlorophyll a concentration(CHL)is an important proxy of the marine ecological environment and phytoplankton production.Long-term trends in CHL of the South China Sea(SCS)reflect the changes in the ecosystem’s productivity and functionality in the regional carbon cycle.In this study,we applied a previously reconstructed 15-a(2005–2019)CHL product,which has a complete coverage at 4 km and daily resolutions,to analyze the long-term trends of CHL in the SCS.Quantile regression was used to elaborate on the long-term trends of high,median,and low CHL values,as an extended method of conventional linear regression.The results showed downward trends of the SCS CHL for the 75th,50th,and 25th quantile in the past 15 a,which were−0.0040 mg/(m^(3)·a)(−1.62%per year),−0.0023 mg/(m^(3)·a)(−1.10%per year),and−0.0019 mg/(m^(3)·a)(−1.01%per year).The negative trends in winter(November to March)were more prominent than those in summer(May to September).In terms of spatial distribution,the downward trend was more significant in regions with higher CHL.These led to a reduced standard deviation of CHL over time and space.We further explored the influence of various dynamic factors on CHL trends for the entire SCS and two typical systems(winter Luzon Strait(LZ)and summer Vietnam Upwelling System(SV))with single-variate linear regression and multivariate Random Forest analysis.The multivariate analysis suggested the CHL trend pattern can be best explained by the trends of wind speed and mixed-layer depth.The divergent importance of controlling factors for LZ and SV can explain the different CHL trends for the two systems.This study expanded our understanding of the long-term changes of CHL in the SCS and provided a reference for investigating changes in the marine ecosystem.
文摘AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction(SAFIRE?) in comparison with a standard MDCT protocol. Fiftythree consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/m L(Accupaque 350~?) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively(SAFIRE?-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio(CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups.RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol(P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different(P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group(P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups(P = 0.9926).CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality.
基金Projects(51535012,U1604255)supported by the National Natural Science Foundation of ChinaProject(2016JC2001)supported by the Key Research and Development Project of Hunan Province,China
文摘The fatigue performance of a workpiece depends on its surface quality.In traditional fatigue life prediction,the effect of surface quality is commonly accounted for by using empirical correction factors,which is imprecise when safety is of great concern.For surface quality,the surface topography is an important parameter,which introduces stress concentration that reduces the fatigue life.It is not feasible to test the stress concentration of different surface topographies.On the one hand,it is time-consuming and high-cost,and on the other hand,it cannot reflect the general statistical characteristics.With the help of surface reconstruction technology and interpolation method,a more efficient and economic approach is proposed,where FE simulation of workpiece with the reconstructed surface topography is used as a foundation for fatigue life prediction.The relationship between surface roughness(Sa)and fatigue life of the workpiece is studied with the proposed approach.
基金We acknowledge the National Natural Science Foundation of China for supporting the project via the grant number 11472062 and 11002034.
文摘OSAHS(Obstructive Sleep Apnea Hypopnea Syndrome)is a respiratory disease mainly characterized by limited and repeated pauses of breathing in sleep.Currently,the optimal treatment is to apply CPAP(Continuous Positive Airway Pressure)ventilation on the upper airway of the patient through a household respiratory machine.However,if the ventilator mask is designed improperly,it might cause the residue and repeated inhalation of CO2,which will exert an adverse impact on the therapeutic effect.Present research numerically analyzed the CO2 transportation inside a commercial ventilator mask(Mirage SoftGel,ResMed,Australia)based on the reconstructed 3D numerical model of a volunteer's face and performed the improved design of the ventilator mask in terms of the CO2 residual concentration below the nostrils.The fluid dynamic analyses showed that at the end time of expiratory,the CO2 residual concentration below the nostrils is close to 4%.To improve the therapeutic effect,we changed the position of the exhaust holes and found that by moving the exhaust holes to the bottom of the ventilator mask,the CO2 residual concentration below the nostrils would be reduced to no more than 1%.This study established a near physiological computational model and provided a new method for the individualized design of the commercial ventilator mask.
基金Project supported by the State Key Development Program for Basic Research of China(Grant No.2006CB601007)the National Natural Science Foundation of China(Grant No.10674006)the National High Technology Research and Development Program of China(Grant No.2007AA03Z238)
文摘This paper constructs a concentric ellipsoid torso-heart model by boundary element method and investigates the impacts of model structures on the cardiac magnetic fields generated by both equivalent primary source--a current dipole and volume currents. Then by using the simulated magnetic fields based on torso-heart model as input, the cardiac current sources--an array of current dipoles by optimal constrained linear inverse method are constructed. Next, the current dipole array reconstruction considering boundaries is compared with that in an unbounded homogeneous medium. Furthermore, the influence of random noise on reconstruction is also considered and the reconstructing effect is judged by several reconstructing parameters.
基金the support from National Natural Science Foundation of China(No.11974156)Guangdong International Science Collaboration Project(No.2019A050510001)the assistance of SUSTech Core Research Facilities,especially technical support from Pico-Centre that receives support from Presidential fund and Development and Reform Commission of Shenzhen。
文摘Two-dimensional(2 D) materials attracted substantial attention due to their extraordinary physical properties resulting from the unique atomic thickness. 2 D materials could be considered as material systems with flat surfaces at both sides, while the van der Waals gap is a natural out-of-plane interface between two monolayers. However, defects are inevitably presented and often cause significant surface and interface reconstruction, which modify the physical properties of the materials being investigated. In this review article, we reviewed the effort achieved in probing the defect structures and the reconstruction of surface and interface in novel 2 D materials through aberration corrected low voltage scanning transmission electron microscopy(LVSTEM). The LVSTEM technique enables us to unveil the intrinsic atomic structure of defects atom-by-atom, and even directly visualize the dynamical reconstruction process with single atom precision. The effort in understanding the defect structures and their contributions in the surface and interface reconstructions in 2 D materials shed light on the origin of their novel physical phenomenon, and also pave the way for defect engineering in future potential applications.