期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Value of myocardial function in children with Kawasaki disease by two-dimensional and three-dimensional ultrasound speckle tracking
1
作者 Ya-Mei Shen Tao-Min Bai +4 位作者 Xue-Mei Zhang Chun-Miao Kang Xiao-Ni Chang Yan-Hua Gao Xiao-Hua Yan 《Journal of Hainan Medical University》 2019年第21期58-61,共4页
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met... Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease. 展开更多
关键词 KAWASAKI disease two-dimensional ultrasound SPECKLE TRACKING three-dimensional ultrasound SPECKLE TRACKING myocardial FUNCTION left ventricular systolic FUNCTION
下载PDF
Differential diagnosis of different types of solid focal liver lesions using two-dimensional shear wave elastography 被引量:6
2
作者 Jia Guo Dong Jiang +4 位作者 Yi Qian Jiao Yu Yi-Jun Gu Yu-Qing Zhou Hui-Ping Zhang 《World Journal of Gastroenterology》 SCIE CAS 2022年第32期4715-4724,共10页
BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible t... BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible types of solid FLLs is important.Our previous study confirmed the value of shear wave elastography(SWE)using maximal elasticity(Emax)as the parameter in the differential diagnosis between benign and malignant FLLs.However,the value of SWE in the differential diagnosis among different pathological types of malignant FLLs has not been proved.AIM To explore the value of two-dimensional SWE(2D-SWE)using Emax in the differential diagnosis of FLLs,especially among different pathological types of malignant FLLs.METHODS All the patients enrolled in this study were diagnosed as benign,malignant or undetermined FLLs by conventional ultrasound.Emax of FLLs and the periphery of FLLs was measured using 2D-SWE and compared between benign and malignant FLLs or among different pathological types of malignant FLLs.RESULTS The study included 32 benign FLLs in 31 patients and 100 malignant FLLs in 96 patients,including 16 cholangiocellular carcinomas(CCCs),72 hepatocellular carcinomas(HCCs)and 12 liver metastases.Thirty-five FLLs were diagnosed as undetermined by conventional ultrasound.There were significant differences between Emax of malignant(2.21±0.57 m/s)and benign(1.59±0.37 m/s)FLLs(P=0.000),and between Emax of the periphery of malignant(1.52±0.39 m/s)and benign(1.36±0.44 m/s)FLLs(P=0.040).Emax of liver metastases(2.73±0.99 m/s)was significantly higher than that of CCCs(2.14±0.34 m/s)and HCCs(2.14±0.46 m/s)(P=0.002).The sensitivity,specificity and accuracy were 71.00%,84.38%and 74.24%respectively,using Emax>1.905 m/s(AUC 0.843)to diagnose as malignant and 23 of 35(65.74%)FLLs with undetermined diagnosis by conventional ultrasound were diagnosed correctly.CONCLUSION Malignant FLLs were stiffer than benign ones and liver metastases were stiffer than primary liver carcinomas.2D-SWE with Emax was a useful complement to conventional ultrasound for the differential diagnosis of FLLs. 展开更多
关键词 Focal liver lesions Conventional ultrasound two-dimensional shear wave elastography Differential diagnosis
下载PDF
Diagnostic problems in two-dimensional shear wave elastography of the liver 被引量:4
3
作者 Hiroko Naganuma Hideaki Ishida +3 位作者 Atsushi Uno Hiroshi Nagai Hidekatsu Kuroda Masahiro Ogawa 《World Journal of Radiology》 CAS 2020年第5期76-86,共11页
Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanis... Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanisms of which remain incompletely understood.This review was designed to present many of the artifactual images seen in 2D-SWE of the liver and to analyze them by computer simulation models that support clinical observations.Our computer simulations yielded the following suggestions:(1)When performing 2D-SWE in patients with chronic hepatic disease,especially liver cirrhosis,it is recommended to measure shear wave values through the least irregular hepatic surface;(2)The most useful 2D-SWE in patients with focal lesion will detect lesions that are poorly visible on B-mode ultrasound and will differentiate true tumors from pseudo-tumors(e.g.,irregular fatty change);and(3)Measurement of shear wave values in the area posterior to a focal lesion must be avoided. 展开更多
关键词 two-dimensional shear wave elastography ultrasound ARTIFACTS Liver cirrhosis Liver tumor Computer simulation model
下载PDF
Clinical Value of Transperineal 3D Volume Ultrasound Combined with 2D High Frequency Ultrasound in Anal Fistula 被引量:3
4
作者 Dan Yang Xiufen Yao 《Journal of Biosciences and Medicines》 2020年第5期12-19,共8页
Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitt... Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitted to the Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine from December 2017 to July 2018 were selected. They were all undergoing transperineal 3D volume ultrasound combined with 2D high-frequency ultrasound examination, and the diagnosis results were analyzed. The results of ultrasonography and surgical pathology were compared. Results: Among 52 patients, 3D volume ultrasound combined with 2D high-frequency ultrasound were used to diagnose 32 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 5 cases of supra-sphincter type, and 1 case of extra-sphincter type. T supervisor classification accuracy rate is 90%. The detection rate of branch pipes was 92%, and the compliance rate of internal fistula was 95%. Two-dimensional high-frequency ultrasound was used to diagnose 34 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 4 cases of supra-sphincter type, and 0 cases of extra-sphincter type. The detection rate of branch canals was 42%, and the accuracy of type classification was 90%. The coincidence rate was 95%. There was a statistically significant difference in the detection rate of the anal fistula branch and the coincidence rate of the internal fistula between the two methods (both P Conclusion: 1) The overall coincidence rate of three-dimensional volumetric ultrasound combined with two-dimensional high-frequency ultrasound in the diagnosis of anal fistula is high;2) Three-dimensional volumetric ultrasound technology has great application prospects in infants and anal fistulas. 展开更多
关键词 two-dimensional HIGH-FREQUENCY ultrasound Anal Fistula Three-Dimensional VOLUME ultrasound COMBINED with two-dimensional HIGH-FREQUENCY ultrasound
下载PDF
Non-invasive assessment of liver fibrosis using twodimensional shear wave elastography in patients with autoimmune liver diseases 被引量:8
5
作者 Jie Zeng Ze-Ping Huang +2 位作者 Jian Zheng Tao Wu Rong-Qin Zheng 《World Journal of Gastroenterology》 SCIE CAS 2017年第26期4839-4846,共8页
AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography(2D-SWE) for the noninvasive assessment of liver fibrosis in patients with autoimmune liver diseases(AILD) using liver biopsy as the r... AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography(2D-SWE) for the noninvasive assessment of liver fibrosis in patients with autoimmune liver diseases(AILD) using liver biopsy as the reference standard.METHODS Patients with AILD who underwent liver biopsy and 2D-SWE were consecutively enrolled. Receiver operating characteristic(ROC) curves were constructed to assess the overall accuracy and to identify optimal cut-off values.RESULTS The characteristics of the diagnostic performance were determined for 114 patients with AILD. The areas under the ROC curves for significant fibrosis, severe fibrosis, and cirrhosis were 0.85, 0.85, and 0.86, respectively, and the optimal cut-off values associated with significant fibrosis(≥ F2), severe fibrosis(≥ F3), and cirrhosis(F4) were 9.7 k Pa, 13.2 k Pa and 16.3 k Pa, respectively. 2D-SWE showed sensitivity values of 81.7% for significant fibrosis, 83.0% for severe fibrosis,and 87.0% for cirrhosis, and the respective specificity values were 81.3%, 74.6%, and 80.2%. The overall concordance rate of the liver stiffness measurements obtained using 2D-SWE vs fibrosis stages was 53.5%.CONCLUSION2D-SWE showed promising diagnostic performance for assessing liver fibrosis stages and exhibited high cut-off values in patients with AILD. Low overall concordance rate was observed in the liver stiffness measurements obtained using 2D-SWE vs fibrosis stages. 展开更多
关键词 Autoimmune liver disease Liver fibrosis two-dimensional shear wave elastography ultrasound Liver stiffness
下载PDF
Assessment of diaphragmatic function by ultrasonography:Current approach and perspectives 被引量:5
6
作者 Alain Boussuges Sarah Rives +1 位作者 Julie Finance Fabienne Brégeon 《World Journal of Clinical Cases》 SCIE 2020年第12期2408-2424,共17页
This article reports the various methods used to assess diaphragmatic function by ultrasonography.The excursions of the two hemidiaphragms can be measured using two-dimensional or M-mode ultrasonography,during respira... This article reports the various methods used to assess diaphragmatic function by ultrasonography.The excursions of the two hemidiaphragms can be measured using two-dimensional or M-mode ultrasonography,during respiratory maneuvers such as quiet breathing,voluntary sniffing and deep inspiration.On the zone of apposition to the rib cage for both hemidiaphragms,it is possible to measure the thickness on expiration and during deep breathing to assess the percentage of thickening during inspiration.These two approaches make it possible to assess the quality of the diaphragmatic function and the diagnosis of diaphragmatic paralysis or dysfunction.These methods are particularly useful in circumstances where there is a high risk of phrenic nerve injury or in diseases affecting the contractility or the motion of the diaphragm such as neuro-muscular diseases.Recent methods such as speckle tracking imaging and ultrasound shear wave elastography should provide more detailed information for better assessment of diaphragmatic function. 展开更多
关键词 ultrasound Hemidiaphragm Motion Thickness PARALYSIS Dysfunction two-dimensional mode M-MODE Speckle tracking imaging ultrasound shear wave elastography
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部