Arrangement Strategy of Ground Heat Exchanger with Groundwater 被引量:4
1
作者 李太禄 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2012年第4期291-297,共7页
The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat t... The orientation strategy of side pipe and the heat transfer performance of six ground heat exchangers(GHEs) were optimized by numerical simulation,with soil being treated as a porous medium.An experiment on the heat transfer of four GHEs was carried out in 2010.Results indicate that the velocity field is disturbed by GHEs.The optimal orientation strategy of side pipe is that the upward pipe is located upstream and the downward pipe downstream.The space between GHEs should be appropriately adjusted,depending on the direction and flow velocity.Groups of GHEs should be installed perpendicular to the mainstream in a single row,but if the acreage does not meet the requirements,GHEs should be installed in staggered multiple rows.Fewer GHEs parallel to the mainstream strengthen the heat transfer.Moreover,numerical results agree well with the test data,with the maximum relative error being less than 7.7%. 展开更多
关键词 埋管换热器 地下水 最大相对误差 数值模拟 传热性能 热交换器 多孔介质 种植面积
下载PDF
Numerical Simulation of Heat Transfer Characteristics of Horizontal Ground Heat Exchanger in Frozen Soil Layer 被引量:2
2
作者 王华军 赵军 《Transactions of Tianjin University》 EI CAS 2007年第3期200-204,共5页
A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numeri... A simplified numerical model of heat transfer characteristics of horizontal ground heat exchanger (GHE) in the frozen soil layer is presented and the steady-state distribution of temperature field is simulated. Numerical results show that the frozen depth mainly depends on the soil′s moisture content and ambient temperature. The heat transfer loss of horizontal GHE tends to grow with the increase of the soil′s moisture content and the decrease of ambient temperature. Backfilled materials with optimal thermal conductivity can reduce the thermal loss effectively in the frozen soil. The applicability of the Chinese national standard “Technical Code for Ground Source Heat Pump (GB 50366-2005)” is verified. For a ground source heat pump project, the feasible layout of horizontal GHE should be determined based on the integration of the soil′s structure, backfilled materials, weather data, and economic analysis. 展开更多
关键词 地面水 散热器 地面温度 热度传播
下载PDF
Experiments Using Capillary Mat as Ground Heat Exchanger for Ground Source Heat Pump Heating Application
3
作者 Arif Widiatmojo Shrestha Gaurav +5 位作者 Takeshi Ishihara Akira Tomigashi Kasumi Yasukawa Youhei Uchida Shohei Kaneko Mayumi Yoshioka 《Energy and Power Engineering》 2019年第11期363-378,共16页
The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, ... The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, the major obstacle hindering the utilization of this technology is the high initial cost, especially for the installation of ground coupled heat exchanger. The horizontal closed-loop system offers lower installation cost, as it requires no vertical borehole construction. Instead, the heat exchangers can be installed in shallow trenches that may be excavated, by small excavator or even by human labor. This paper presents the comparison of two different heat exchangers, namely, the capillary mat and the widely used slinky pipe. Both heat exchangers are connected to a heat pump, where continuous heating tests were carried out for 165 hours (~7 days) for each configuration. The purpose of this research is to show the performance of capillary mat in comparison to slinky pipe. Despite during the entire test for capillary mat required 6% higher electricity consumption, compared to slinky heat exchanger, the results still suggest the potential use of capillary mat as alternative to slinky heat exchanger. Additionally, the results also highlight the high hydraulic resistance of installed capillary mat heat exchangers may become the major disadvantage of the capillary mat. 展开更多
关键词 HORIZONTAL heat exchanger ground Source heat PUMP CAPILLARY MAT
下载PDF
Experimental Analysis of Horizontal Ground Heat Exchanger for Northern Tunisia
4
作者 Nabiha Naili Issam Attar +1 位作者 Majdi Hazami Abdelhamid Farhat 《Journal of Electronics Cooling and Thermal Control》 2012年第3期44-51,共8页
The aim of this study is first to evaluate the Tunisian geothermal energy and second to test the performance of horizontal ground heat exchanger. An experimental set-up has been constructed for climatic condition of B... The aim of this study is first to evaluate the Tunisian geothermal energy and second to test the performance of horizontal ground heat exchanger. An experimental set-up has been constructed for climatic condition of Borj Cedria located in the north of Tunisia for space cooling. Results obtained during experiment were presented and discussed. The ground temperature at several depths was measured, the overall heat transfer coefficient (U) was determined. To evaluate the system efficiency, the energy analysis was applied;the energy efficiency was found to range from 14% to 28%. The heat exchange rate was quantified, the pressure losses were calculated. The total heat rejected by using the ground heat exchanger (GHE) system was compared to the total cool requirements of a tested room with 12 m2 surface. The results showed that the GHE, with 25 m of length buried at 1 m depth, covers 38% of the total cool requirement of the tested room. This study showed that the ground heat exchanger provide a new way of cooling buildings, it also showed that Tunisia have an important thermal potential. This favorable circumstance allows Tunisia to be a pioneer in the exploitation of geothermal energy for the installation of ground source heat pump systems. 展开更多
关键词 HORIZONTAL ground heat exchanger GEOTHERMAL HOT CLIMATE Energy Efficiency
下载PDF
Experimental Verification to Estimate Ground Thermal Conductivity Using Spiral Coil Type Ground Heat Exchangers
5
作者 Seok Yoon Min Jun Kim Gyu Hyun Go Seung Rae Lee 《Journal of Civil Engineering and Architecture》 2014年第4期425-429,共5页
关键词 埋管换热器 螺旋线圈 热传导率 实验 验证 地热 估计 部分饱和
下载PDF
Soil Nature Effect Investigation on the Ground-to-Air Heat Exchanger for the Passive Cooling of Rooms
6
作者 Kokou N’wuitcha Yendouban Kolani +2 位作者 Yawovi Nougblega Magolmèèna Banna Belkacem Zeghmati 《Open Journal of Fluid Dynamics》 CAS 2022年第4期321-341,共21页
The building sector consumes much energy either for cooling or heating and is associated to greenhouse gas emissions. To meet energy and environmental challenges, the use of ground-to-air heat exchangers for preheatin... The building sector consumes much energy either for cooling or heating and is associated to greenhouse gas emissions. To meet energy and environmental challenges, the use of ground-to-air heat exchangers for preheating and cooling buildings has recently received considerable attention. They provide substantial energy savings and contribute to the improvement of thermal comfort in buildings. For these systems, the ground temperature plays the main role. The present work aims to investigate numerically the influence of the nature of soil on the thermal behavior of the ground-to-air heat exchanger used for building passive cooling. We have taken into account in this work the influence of the soil nature by considering three types of dry soil: clay soil, sandy-clay soil and sandy soil. The mixed convection equations governing the heat transfers in the earth-to-air heat exchanger have been presented and discretized using the finite difference method with an Alternate Direction Implicit (ADI) scheme. The resulting algebraic equations are then solved using the algorithm of Thomas combined with an iterative Gauss-Seidel procedure. The results show that the flow is dominated by forced convection. The examination of the sensitivity of the model to the type of soil shows that the distributions of contours of streamlines, isotherms, isovalues of moisture are less affected by the variations of the nature of soil through the variation of the diffusivity of the soil. However, it is observed that the temperature values obtained for the clay soil are higher while the sandy soil shows lower temperature values. The values of the ground-to-air heat exchanger efficiency are only slightly influenced by the nature of the soil. Nevertheless, we note a slightly better efficiency for the sandy soil than for the sandy-clayey silt and clayey soils. This result shows that a sandy soil would be more suitable for geothermal system installations. 展开更多
关键词 Soil Temperature Laminar Regime ground-To-Air heat exchanger heat Transfer Geothermal System
下载PDF
Research on ground heat exchanger of Ground Source Heat Pump technique
7
作者 LIUDong-sheng SUNYou-hong GAOKe WUXiao-hang 《Journal of Geoscientific Research in Northeast Asia》 2004年第2期196-199,共4页
Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to d... Ground Source Heat Pump technique and its operating principle are described in this paper. Ground heat exchanger is the key technique of ground source heat pump and its patterns are discussed. Software is helpful to design ground heat exchanger. A project of Chinese Ground Source Heat Pump is introduced and its market is more and more extensive. 展开更多
关键词 土源热泵 热交换 软件设计 数学模型
下载PDF
Advances in ground heat exchangers for space heating and cooling:Review and perspectives 被引量:1
8
作者 Ping Cui Weibo Yang +3 位作者 Wenke Zhang Ke Zhu Jeffrey D.Spitler Mingzhi Yu 《Energy and Built Environment》 2024年第2期255-269,共15页
As a renewable energy source,geothermal energy has been widely used to provide space heating and cooling for buildings.The thermal performance of ground heat exchanger(GHE)is significant for the operating efficiency o... As a renewable energy source,geothermal energy has been widely used to provide space heating and cooling for buildings.The thermal performance of ground heat exchanger(GHE)is significant for the operating efficiency of the ground source heat pump(GSHP)systems.This paper presents a comprehensive review of developments and advances of three kinds of GHE,including vertical borehole GHE(VBGHE),Pile GHE(PGHE),and deep borehole GHE(DBGHE)which are currently popular in larger GSHP systems.Firstly,analytical models proposed to ana-lyze heat transfer process of VBGHE with different geological conditions are summarized,such as homogenous or heterogeneous ground,with or without groundwater advection.Numerical and short-time step models and measures to improve GHE thermal performance are also reviewed.Secondly,a summary of research advances in PGHE is provided,which includes the heat transfer models of PGHE,the effects of geometric structure,oper-ation modes,pile spacing,use of phase change material(PCM),thermal properties of PCM,thermo-mechanical behavior and/or thermal performance of PGHE.The effects of groundwater flow direction and velocity on PGHE are also summarized in brief.Lastly,models of three kinds of DBGHEs,i.e.,deep coaxial GHE(DCGHE),deep U-bend GHE(DUGHE)and super-long gravity heat pipe(SLGHP),are reviewed.The physical bases of the dif-ferent analytical models are elaborated and also their advantages and disadvantages are described.Advances in numerical modelling and improving numerical model calculation speed of DCBHE,DCBHE array,and DUBHE are summarized.The review provides a meaningful reference for the further study of GHEs. 展开更多
关键词 Vertical borehole ground heat exchanger Pile ground heat exchanger Deep borehole ground heat exchanger Modelling
原文传递
Research on Performance of Ground-Source Heat Pump Double U Underground Pipe Heat Exchange 被引量:1
9
作者 Youyin Jing Jing Hou Peng Yang 《Open Journal of Modelling and Simulation》 2013年第1期1-6,共6页
This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the conditi... This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment. 展开更多
关键词 ground-Source heat PUMP DOUBLE U UNDERground PIPE heat exchange Soil Temperature Field
下载PDF
Achieving Cooler Soil as an Effective Heat Sink for Earth-to-Air Heat Exchanger (EAHE) Cooling Technology in Malaysia Tropical Climate
10
作者 Aliyah Nur Zafirah Sanusi Aidil Azlan Ahmad Zamri 《Natural Resources》 2014年第13期804-809,共6页
This research is intended to explore the capacity of Malaysia soil in becoming a more effective heat sink for the application of Earth-to-Air Heat Exchanger (EAHE) Cooling Technology in Malaysia. EAHE Cooling Technolo... This research is intended to explore the capacity of Malaysia soil in becoming a more effective heat sink for the application of Earth-to-Air Heat Exchanger (EAHE) Cooling Technology in Malaysia. EAHE Cooling Technology consists of buried pipes underground where the ambient air is channeled through from the pipe inlet and produces cooler air at its outlet. Within the buried pipes, heat exchange process occurs between the air and the soil that surrounding the pipe. This building cooling technology has been applied in many countries, mostly in temperate or hot and arid climate where the diurnal temperature is large. However, minimal resources were found on the study of EAHE application to buildings in Malaysia, hence there is room to develop. A parametric study on EAHE cooling application in Malaysia was done through field experiment and concluded that among many parameters affecting the technology performance, the soil temperature which surrounded the pipe was the most influential factor. The study recommended to further reduce the soil temperature to achieve a cooler outlet temperature. In response to that, this research conducted a parametric study of soil temperature under three different soil surface conditions: bare, shaded with timber pallettes and insulated with used tyres at 1.0 m and 1.5 m underground. The data was logged for a month and the result has shown significant reduction in the soil temperature underground below the shaded and insulated soil surface as compared to below bare soil surface condition. The insulated soil surface produced the best result where the soil temperature was reduced up to 26.9°C. The main contribution of this paper is to highlight that the soil surface treatment can be used to reduce solar heat gain within the soil underground and thus improving the performance of EAHE Cooling Technology particularly for the application in Malaysia tropical climate. 展开更多
关键词 ground COOLING Green Technology Earth-to-Air heat exchanger Cooled SOIL
下载PDF
Experimental study on heat exchange of several types of exchangers
11
作者 周志华 赵振华 于洋 《Journal of Central South University》 SCIE EI CAS 2009年第S1期204-208,共5页
Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers bu... Aiming at the ground-coupled source heat pump that possesses the shortcomings of occupying larger land,this article studies the heat exchanged of heat exchanger in piling,and compares it with common heat exchangers buried directly. The result indicates that the heat exchanger makes the best use of structure of building,saves land,reduces the construction cost,and the heat exchanged is obviously more than exchangers buried directly. In winter condition,when W-shape pipe heat exchanger in pile foundation is 50 m deep and diameter is 800 mm,it transfers 1.2-1.3 times as large as the one of single U-shape buried directly at the flow rate of 0.6 m/s,whose borehole diameter is 300 mm. And in summer condition it does about 2.0-2.3 times as that of U-shape one. 展开更多
关键词 ground-coupled source heat pump heat exchanger in PILE FOUNDATION single U-shape pipe heat exchanger BURIED directly heat exchange
下载PDF
Experimental Investigation on System with Combination of Ground-Source Heat Pump and Solar Collector 被引量:4
12
作者 胡涛 朱家玲 张伟 《Transactions of Tianjin University》 EI CAS 2013年第3期157-167,共11页
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calcu... This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively. 展开更多
关键词 ground-source heat PUMP solar energy heating performance BOREHOLE heat exchanger
下载PDF
Field evaluation of a ground-coupled heat pump in hot-summer and cold-winter regions 被引量:1
13
作者 雷飞 《Journal of Chongqing University》 CAS 2011年第4期159-167,共9页
The experimental performance of small-sized ground-coupled heat pump (GCHP) is researched intensively. However, there are little data documenting the operation performance of existing large-sized GCHP system. We prese... The experimental performance of small-sized ground-coupled heat pump (GCHP) is researched intensively. However, there are little data documenting the operation performance of existing large-sized GCHP system. We presented the actual performance measurement of a GCHP installed for apartment buildings in Wuhan, Hubei province, P. R. China. The system was constructed with a closed vertical typed ground heat exchanger with a total pipe length of 32 000 m. During one year, various operating parameters were monitored, including the outdoor temperature, the flow rate, the electrical consumption, and the water temperature. The seasonal coefficients of performances of the heat pumps and the system based on the measured data were found to be 4.01 and 2.96 in the cooling season, and 3.54 and 2.86 in the heating season, respectively. The GCHP system was more economical than the air-source room air conditioner in the energy efficiency which was increased by 29% in cooling mode and 50% in heating mode. There was an obvious heat imbalance of soil between the injection rate and the extraction rate in the residential GCHP system operation. 展开更多
关键词 联合地面的热泵 性能的系数 地面热 exchanger 回答评估
下载PDF
地下隐蔽工程地源热泵地埋管管群优化研究
14
作者 郭敏 张珊珊 +3 位作者 韩玮玮 杨洪林 孙鹏 刁乃仁 《山东建筑大学学报》 2024年第4期48-55,共8页
地下建筑地源热泵系统向地下释放的热量常大于所提取的热量,容易造成地埋管区域的热量累积,影响其正常使用。因此,提高地埋管换热器效率,减弱冷热量失衡影响,是地下隐蔽工程应用地源热泵系统亟需解决的问题。文章基于换热器温差场均匀... 地下建筑地源热泵系统向地下释放的热量常大于所提取的热量,容易造成地埋管区域的热量累积,影响其正常使用。因此,提高地埋管换热器效率,减弱冷热量失衡影响,是地下隐蔽工程应用地源热泵系统亟需解决的问题。文章基于换热器温差场均匀性原则,采用全局优化遗传算法,优化了地埋管换热器管群布置。结果表明:与传统等间距方案相比,优化布置后,16、25个钻孔方案的平均无因次温变热阻分别降低了13.8%和53.3%,平均换热效率分别提高了3.76%和5.74%,即钻孔数量越多,换热效率提升越明显。 展开更多
关键词 多种群遗传算法 负荷不平衡 位置优化 地埋管换热器
下载PDF
装配式柔性墙体日光温室联合储热系统蓄放热特性
15
作者 马蔷薇 李明 +3 位作者 王利春 胡娟秀 宋卫堂 魏晓明 《农业工程学报》 EI CAS CSCD 北大核心 2024年第15期183-193,共11页
增设多蓄热介质联合主动蓄放热系统是解决装配式柔性墙体日光温室“重保温、轻蓄热”问题的有效方法,但当前对于“土壤-空气-水”多介质联合储热系统蓄放热特性和加温效果尚不明确,针对此问题,该研究以配备“空气源地中热交换-水源后墙... 增设多蓄热介质联合主动蓄放热系统是解决装配式柔性墙体日光温室“重保温、轻蓄热”问题的有效方法,但当前对于“土壤-空气-水”多介质联合储热系统蓄放热特性和加温效果尚不明确,针对此问题,该研究以配备“空气源地中热交换-水源后墙循环换热”联合储热系统的装配式柔性墙体日光温室为研究对象,采用现场跟踪测试和能量转移测算,对联合储热系统各自和组合的蓄放热特性进行研究。结果表明,配有联合储热系统的装配式柔性墙体日光温室室内夜间最低空气温度维持在10℃以上,室内外最大温差达26.5℃。0~50 cm的土壤层是该温室主要蓄热介质,晴天土壤层蓄热量最高占总蓄热量的63.5%。地中热交换系统最高占土壤蓄热量的54.4%。水循环系统蓄热量可达424.04 MJ,最高占总蓄热量的45.1%,通过循环蓄热可将储水池内8 m3水的温度提高到35℃。连阴天时,通过引入蓄放热比指标,对联合储热系统的运行效果进行定量评价,发现水循环系统具有蓄放热速度快的特点,蓄放热比绝对值最高可达1.62,是当天土壤蓄放热的1.8倍。但从总量上看,土壤仍是连阴天主要放热来源,在北京地区联合蓄放热系统能够维持3个连阴天的热量需求。水循环系统平均性能系数(coefficient of performance,COP)为9.16,地中热交换系统平均COP为6.82,联合蓄放热系统综合COP为8.85,对比热泵,其节能率达60.26%。研究结果为联合储热系统蓄放热机理研究提供了理论依据。 展开更多
关键词 日光温室 墙体 传热 联合储热 蓄放热特性 水循环 地中换热
下载PDF
竖进平出型地埋管群换热器结构与控制优化
16
作者 马培发 张杰 +1 位作者 于春雨 汪浩瀚 《发电技术》 CSCD 2024年第3期478-485,共8页
【目的】为提高浅层地热能利用效率,亟须对影响地源热泵系统性能的地埋管换热器结构和控制开展优化设计。【方法】建立了一种竖进平出型地埋管群换热器模型,研究其换热系统性能,探究其最佳结构及运行方式。【结果】管群布置横纵比越低,... 【目的】为提高浅层地热能利用效率,亟须对影响地源热泵系统性能的地埋管换热器结构和控制开展优化设计。【方法】建立了一种竖进平出型地埋管群换热器模型,研究其换热系统性能,探究其最佳结构及运行方式。【结果】管群布置横纵比越低,单位面积换热量越大,横纵比超过0.15后对系统影响较小;换热器间距越小,土壤利用率越高,但热短路损失越大;双列双出型埋管每延米换热量相较于双列单出型结构提升7%以上;负荷较大工况下叉排布置结构的换热效果更好;整个夏季优化结构的平均出口温度下降2.28℃,换热器周围土壤温度下降1℃以上;实际运行过程中应优先考虑采用流速随负荷变化控制模式。【结论】研究结果可为地源热泵换热器的设计、制造提供理论依据。 展开更多
关键词 地源热泵 地埋管群 换热器 热短路 控制模式
下载PDF
基于土壤分层当量物性的地埋管换热器换热模型研究
17
作者 徐若恩 陈金华 +1 位作者 唐茂川 杜龙跃 《可再生能源》 CAS CSCD 北大核心 2024年第2期174-181,共8页
文章综合考虑了土壤分层与地下水渗流等情况,结合实测数据,通过地埋管外壁温度计算得出地埋管内部流体温度与不同分层土壤的热物性参数,根据土壤当量物性进行分层,据此建立地埋管换热模型。经过对比验证实验发现,分层换热模型比常规均... 文章综合考虑了土壤分层与地下水渗流等情况,结合实测数据,通过地埋管外壁温度计算得出地埋管内部流体温度与不同分层土壤的热物性参数,根据土壤当量物性进行分层,据此建立地埋管换热模型。经过对比验证实验发现,分层换热模型比常规均质模型更接近实测值,误差更小;基于土壤分层当量物性的地埋管换热器换热模型模拟出水温度与实测值平均绝对误差为0.21℃,模拟进、出口换热温差与实测值平均绝对误差为0.14℃,具有较高的准确度,可为工程设计提供依据并作为后续地埋管换热优化研究的基础。 展开更多
关键词 地埋管换热器 分层换热模型 地源热泵 当量热阻
下载PDF
土壤源热泵地埋管侧水系统优化运行研究
18
作者 陈鹏旭 许波 +1 位作者 陈振乾 陈翔燕 《制冷学报》 CAS CSCD 北大核心 2024年第1期110-117,共8页
本文基于江苏无锡某典型厂房土壤源热泵空调项目的实测数据,以地源侧系统总能耗最低为目标,构建设备模型对地源水泵运行工况进行优化,并与两种传统控制策略的运行效果进行对比,据此提出进一步的优化建议。结果表明:基于负荷的优化控制策... 本文基于江苏无锡某典型厂房土壤源热泵空调项目的实测数据,以地源侧系统总能耗最低为目标,构建设备模型对地源水泵运行工况进行优化,并与两种传统控制策略的运行效果进行对比,据此提出进一步的优化建议。结果表明:基于负荷的优化控制策略,其节能效果要明显优于定频控制策略,冬夏季典型测试日平均节能率分别为28.33%和13.27%,相比于5℃温差变频策略节能了3.61%和2.21%。适当增大地埋管的埋管深度或管径,可以进一步提升该优化控制策略的节能效果。传统的定温差控制策略在负荷率大于60%时,可在5℃基础上将温差增加1~5℃以提升节能效果。 展开更多
关键词 土壤源热泵 地埋管换热器 变流量 供回水温差 节能率
下载PDF
中深层套管式地埋管地源热泵系统能效分析
19
作者 曹雨晨 孔维政 +3 位作者 陈睿 林朵童 黄帅 董建锴 《暖通空调》 2024年第4期67-73,共7页
中深层套管式地埋管地源热泵系统的能效受多种因素影响,为保证其高效运行,对其影响因素进行研究尤为重要。本文建立了中深层套管式地埋管地源热泵系统换热器传热模型,采用工程实测数据验证该模型的准确性。基于该模型,量化了一个供暖期... 中深层套管式地埋管地源热泵系统的能效受多种因素影响,为保证其高效运行,对其影响因素进行研究尤为重要。本文建立了中深层套管式地埋管地源热泵系统换热器传热模型,采用工程实测数据验证该模型的准确性。基于该模型,量化了一个供暖期内多种因素对系统能效的影响。结果表明:进口水温和岩土导热系数对系统能效具有重要影响,回填材料导热系数对其影响较小;增大循环流量会提高取热功率,但系统能效也随之降低,当循环流量由8.33 kg/s增大至10.56 kg/s时,取热功率提升4.95%,能效下降1.23%;增大外管管径、岩土和回填材料的导热系数能够提升系统能效,但达到一定数值后,对能效提升效果不显著。本研究对中深层套管式地埋管地源热泵系统长期稳定运行及能效提升具有参考意义。 展开更多
关键词 中深层地热能 地源热泵 套管式地埋管换热器 运行性能 能效分析
下载PDF
竖直单U型地埋管换热器埋管间负热阻现象的参数化研究与分析
20
作者 李露茜 廖全 +1 位作者 刘贤燕 彭清元 《太阳能学报》 EI CAS CSCD 北大核心 2024年第3期210-216,共7页
基于Mutipole方法对竖直单U型地埋管换热器钻孔内外的耦合传热过程进行求解,在钻孔内三热阻和四热阻简化传热模型基础上,详细地分析钻孔内的复杂稳态传热过程,参数化研究埋管布置结构、回填料与岩土热物性等因素对钻孔内埋管间直接传热... 基于Mutipole方法对竖直单U型地埋管换热器钻孔内外的耦合传热过程进行求解,在钻孔内三热阻和四热阻简化传热模型基础上,详细地分析钻孔内的复杂稳态传热过程,参数化研究埋管布置结构、回填料与岩土热物性等因素对钻孔内埋管间直接传热热阻的影响规律,揭示导致钻孔内埋管间负热阻现象的本质原因,对钻孔内热阻传热模型的工程实践应用给出参考意见。 展开更多
关键词 地源热泵 换热器 热阻 负热阻现象 Multipole法
下载PDF