The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV)...The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level.展开更多
The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced...The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff.展开更多
The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with...The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with the symmetrical distributed parameter circuit model as the equivalent circuit of the un-transposed ultra high voltage(UHV) transmission line were studied under both normal operation and fault,and the corresponding problems arising were pointed out. By contrast with electromagnetic transient and power electronics(EMTPE) simulation results with the asymmetrical distributed parameter circuit model of un-transposed line, it is shown that the conventional method cannot show the existence of negative and zero sequences before fault happening and there are many errors on voltage and current after fault happening which are different with fault types. The error ranges of voltage and current are 2.13%-81.13% and -7.82%- -86.15%, respectively.展开更多
The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharg...The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharge theories of long air gap and randomness theory,a leader progression model of lightning shielding failure is presented in this paper.The random characteristics of the downward and upward leader are simulated in this model.The ground slope angel is also considered in this model by using coordinate transformation.Moreover,the system voltage is also taken into consideration in this model.The simulation results show that the good agreement between this model and the field data.And the results suggest that return striking exist obviously in UHV transmission line.展开更多
The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods...The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods and comparing them to indicate healthy and faulty conditions. In order to study the performance and feasibility of the protection based on balance of energy, the new protection has been extensively tested by using EMTP on a long transmission line with various configurations and operating conditions (including single pole line, double circuit lines and two phase operation). The results calculated by EMTP show that under any condition of a power system, the proposed technique has excellent performance,the viability even for high resistance ground faults and a short operation time.展开更多
Some double-circuit transmission lines are untransposed,which results in complex coupling relations between the parameters of the transmission lines.If the traditional modal transformation matrix is directly used to d...Some double-circuit transmission lines are untransposed,which results in complex coupling relations between the parameters of the transmission lines.If the traditional modal transformation matrix is directly used to decouple the parameters,it can lead to large errors in the decoupled modal parameter,errors which will be amplified in the fault location equation.Consequently,it makes the fault location results of the untransposed double-circuit transmission lines less accurate.Therefore,a new modal transformation method is needed to decou-ple the parameter matrix of untransposed double-circuit transmission lines and realize the fault location according to the decoupled modal parameter.By improving the basis of the Karrenbauer matrix,a modal transformation matrix suitable for decoupling parameters of untransposed double-circuit transmission lines is obtained.To address the dif-ficulties in solving the fault location equation of untransposed double-circuit transmission lines,a new fault location method based on an improved Karrenbauer matrix and the quantum-behaved particle swarm optimization(QPSO)algorithm is proposed.Firstly,the line parameter matrix is decomposed into identical and inverse sequence compo-nents using the identical-inverse sequence component transformation.The Karrenbauer matrix is then transformed to obtain the improved Karrenbauer matrix for untransposed double-circuit transmission lines and applied to identi-cal and inverse sequence components to solve the decoupled modal parameter.Secondly,based on the principle that voltage magnitudes at both ends are equal,the fault location equation is expressed using sequence compo-nents at each end,and the QPSO algorithm is introduced to solve the equation.Finally,the feasibility and accuracy of the proposed method are verified by PSCAD simulation.The simulation results fully demonstrate that the innova-tive improvement on the basis of the traditional modal transformation matrix in this paper can realize the modal transformation of the complex coupling parameters of the untransposed double-circuit transmission lines.It causes almost no errors in the decoupling process.The QPSO algorithm can also solve the fault location equation more accu-rately.The new fault location method can realize the accurate fault location of untransposed double-circuit transmis-sion lines.展开更多
Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term...Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode.展开更多
特高压(ultra high voltage,UHV)交流与直流线路同廊道运行时带电作业区域电压高、场强大,交直流混合电场比单一电场更为复杂。为确保作业人员安全,结合实际±1100 kV直流和1000 kV交流线路,建立了包含输电导线、杆塔及带电作业人...特高压(ultra high voltage,UHV)交流与直流线路同廊道运行时带电作业区域电压高、场强大,交直流混合电场比单一电场更为复杂。为确保作业人员安全,结合实际±1100 kV直流和1000 kV交流线路,建立了包含输电导线、杆塔及带电作业人员的三维计算模型,通过分析开展带电作业时人员的体表混合场强、电位转移电流及暂态能量,对作业人员安全防护进行研究。结果表明:随着作业人员不断接近直流线路,体表场强受交流线路影响越明显,最高可使作业人员体表场强增大约9%,达到1920 kV/m;交流线路的存在将导致电位转移电流增长约7%,但对暂态能量影响较小。通过对特高压线路不停电检修所减少的碳排放量进行进一步计算,验证了特高压带电作业对减少碳排放具有促进作用。展开更多
基金ABB (China) Research Ltd. and National Natural Science Foundation of China(No.50477037)
文摘The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level.
文摘The induced electricity of 110 kV transmission lines which cross the UHV AC transmission lines may threaten personal safety of the maintenance staff. In this paper, field measurement of the induced voltage and induced current on a 110 kV crossing line inside Jinhua in Zhejiang province is performed. The electrostatic induced voltage on the measured line is 12.24 kV. The power frequency electromagnetic field simulation model is established, and the calculation results are consistent with the measured. Influence factors analysis shows that the electrostatic induced voltage on the 110 kV line is 12.78 kV, the electromagnetic induced voltage is 12.3 V, the induced current through ground wire is less than 1A when the UHV lines operate at full load. The induced voltage and current decrease while the crossing distance increases. Parallel lines induction is much higher than crossing lines. The electromagnetic induced voltage after ground knife-switch shut down would exceed the human safety voltage 36 V while the crossing angle is less than 30?, so the temporary ground wire must be hanged to ensure safety of the maintenance staff.
文摘The conventional fault analysis method based on symmetrical components supposes that the three-phase parameters of un-transposed transmission line are symmetrical in case of fault. The errors caused by the method with the symmetrical distributed parameter circuit model as the equivalent circuit of the un-transposed ultra high voltage(UHV) transmission line were studied under both normal operation and fault,and the corresponding problems arising were pointed out. By contrast with electromagnetic transient and power electronics(EMTPE) simulation results with the asymmetrical distributed parameter circuit model of un-transposed line, it is shown that the conventional method cannot show the existence of negative and zero sequences before fault happening and there are many errors on voltage and current after fault happening which are different with fault types. The error ranges of voltage and current are 2.13%-81.13% and -7.82%- -86.15%, respectively.
基金Project Supported by National Natural Science Foundation of China (50707036), Key Project of the National Eleventh-five Year Research Program of China (2006BAA02A18).
文摘The operation data obtained abroad indicates that shielding failure in UHV transmission lines mostly accounts for the tripping-out accidents introduced by lightning striking the transmission line.Based on the discharge theories of long air gap and randomness theory,a leader progression model of lightning shielding failure is presented in this paper.The random characteristics of the downward and upward leader are simulated in this model.The ground slope angel is also considered in this model by using coordinate transformation.Moreover,the system voltage is also taken into consideration in this model.The simulation results show that the good agreement between this model and the field data.And the results suggest that return striking exist obviously in UHV transmission line.
文摘The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods and comparing them to indicate healthy and faulty conditions. In order to study the performance and feasibility of the protection based on balance of energy, the new protection has been extensively tested by using EMTP on a long transmission line with various configurations and operating conditions (including single pole line, double circuit lines and two phase operation). The results calculated by EMTP show that under any condition of a power system, the proposed technique has excellent performance,the viability even for high resistance ground faults and a short operation time.
基金funded by the National Natural Science Foundation of China(No.62363022,61663021,71763025,61861025)the Natural Science Foundation of Gansu Province(No.23JRRA886)the Gansu Provincial Department of Education:Industrial Support Plan Project(No.2023CYZC-35).
文摘Some double-circuit transmission lines are untransposed,which results in complex coupling relations between the parameters of the transmission lines.If the traditional modal transformation matrix is directly used to decouple the parameters,it can lead to large errors in the decoupled modal parameter,errors which will be amplified in the fault location equation.Consequently,it makes the fault location results of the untransposed double-circuit transmission lines less accurate.Therefore,a new modal transformation method is needed to decou-ple the parameter matrix of untransposed double-circuit transmission lines and realize the fault location according to the decoupled modal parameter.By improving the basis of the Karrenbauer matrix,a modal transformation matrix suitable for decoupling parameters of untransposed double-circuit transmission lines is obtained.To address the dif-ficulties in solving the fault location equation of untransposed double-circuit transmission lines,a new fault location method based on an improved Karrenbauer matrix and the quantum-behaved particle swarm optimization(QPSO)algorithm is proposed.Firstly,the line parameter matrix is decomposed into identical and inverse sequence compo-nents using the identical-inverse sequence component transformation.The Karrenbauer matrix is then transformed to obtain the improved Karrenbauer matrix for untransposed double-circuit transmission lines and applied to identi-cal and inverse sequence components to solve the decoupled modal parameter.Secondly,based on the principle that voltage magnitudes at both ends are equal,the fault location equation is expressed using sequence compo-nents at each end,and the QPSO algorithm is introduced to solve the equation.Finally,the feasibility and accuracy of the proposed method are verified by PSCAD simulation.The simulation results fully demonstrate that the innova-tive improvement on the basis of the traditional modal transformation matrix in this paper can realize the modal transformation of the complex coupling parameters of the untransposed double-circuit transmission lines.It causes almost no errors in the decoupling process.The QPSO algorithm can also solve the fault location equation more accu-rately.The new fault location method can realize the accurate fault location of untransposed double-circuit transmis-sion lines.
基金supported in part by the National Basic Research Program(973 Program)under Grant 2011CB209402-3the Science and Technology Project of the State Grid Corporation of China under Grant GY71-15-033.
文摘Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode.