[Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The ...[Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The samples were extracted with an acetonitrile water solution(8∶2),0.1 mol/L hydrochloric acid and a purification extraction bag with shaking.Centrifugation was performed to obtain supernatants,which were added to purification tubes containing PSA and C_(18) for purification,and then filtered with membranes for determination.Each test solution was separated by a ZORBAX Eclipse plus C_(18) column with acetonitrile and 5 mmol/L ammonium acetate as mobile phases,and determined with electrospray ionization and multiple reaction monitoring.[Results]The method had good linearity in the concentration range of 1.0-50 ng/ml,and the correlation coefficient was 0.9997.The limit of detection was 0.25μg/kg and the limit of quantification was 0.75μg/kg.The recovery was between 87.4%and 112.5%,and the RSD%was between 0.5%and 10.0%.[Conclusions]The method has simple operation and high sensitivity,and is suitable for trace detection of sodium pentachlorophenoxide in large quantities of animal-derived food.展开更多
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g...[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton.展开更多
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte...An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.展开更多
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ...To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.展开更多
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s...A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC...Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis,...A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis, 2 μL rabbit serum was precipitated with methanol that contained the internal standard teicoplanin (TEI). The supernatant was transferred into a 384 well-plate, diluted with water, covered with a pierceable silicone mat and 5 μL was analyzed in positive ionization mode. The UHPLC-MS/MS consisted of an Agilent 1290 Infinity UHPLC system connected to an AB Sciex QTrap®5500 hybrid linear ion-trap triple quadrupole mass spectrometer equipped with a Turbo Spray source. Chromatographic separation was achieved using a Waters Acquity UPLC BEH C18 (1.7 μm, 2.1 mm × 100 mm) column, a VanGuard (1.7 μm, 2.1 × 5 mm) guard column and a mobile phase of water and methanol both containing 5 mM ammonium acetate with 0.1% formic acid. VAN was quantified with multiple reaction monitoring using the transitions of m/z 725.5/144.2, and TEI was monitored at m/z 940.6/316.4. The accuracy, precision, linearity, range and lower limit of quantification (LLOQ) were determined. The accuracy was ≤9.93% and the precision was ≤10.6%. The range was established as 0.1 to 40 μg·mL-1. The LLOQ was 0.1 μg·mL-1 VAN requiring 2 μL of sample with an accuracy of -20.2% and precision of 8.39%. The method was applied successfully to determine the VAN concentrations in rabbit serum after the i.v. administration of VAN via implanted ear catheters.展开更多
Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more ...Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasis MCX cartridges. Chromatographic separation on a Cr8 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid. Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L. The precision of the method, calculated as relative standard deviation (RSD), was below 14.6% for all the compounds. The limits of detection (LODs) varied from 0.45 pg to 7.97 pg. The method was applied to detemaine the target analytes in coastal waters of the Yellow Sea in Liaoning, China. Among the tested antibiotics, 31 were found in coastal 'waters, with their concentrations between the LOD and 212.5 ng/L. These data indicate that this method is valid for analysis of antibiotics in coastal waters. The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning, and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems展开更多
[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical c...[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients a...Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.展开更多
基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,...基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。展开更多
Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify ...Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify and quantify DSP toxins in shellfish. This new methodology could facilitate DSP monitoring and create a means of rapidly responding to incidents threatening public health. In the last years there were different analytical methods for DSP, such as mouse bioassay and LC-FLD. With the development of instrument, Liquid chromatography-mass spectrometry was substituted for other analytical methods with its good sensitivity and selectivity and without derivatization for the determination of DSP. In this report, a high performance liquid chromatogra-phytandem mass spectrometric(HPLC-MS/MS)method was developed for the simultaneous determination of okadaic acid (OA) and dinophysistoxins(DTX1) in Sinonovacula constricta. Optimization of pretreatment experiment was carried out to maximize recoveries and the effectiveness. The analytes were determined under multi-reactions monitoring (MRM) scan type with tandem mass analyzer using negative ion electrospray ionization (-ESI) mode .Finally, the detection and identification of OA and DTX-1 were based upon their retention times (RT) and the fragmentation patterns of their mass spectra. The method of LOQ for the two poisons was 0.02 mg·kg-1.The real sample test showed that this method could be used for sensitive, fast, and accurate determination of the two diarrheic shellfish poisons in shellfish.展开更多
文摘[Objectives]This study was conducted to establish an ultra-high performance liquid chromatography-tandem mass spectrometry for the rapid extraction of sodium pentachlorophenoxide from animal-derived food.[Methods]The samples were extracted with an acetonitrile water solution(8∶2),0.1 mol/L hydrochloric acid and a purification extraction bag with shaking.Centrifugation was performed to obtain supernatants,which were added to purification tubes containing PSA and C_(18) for purification,and then filtered with membranes for determination.Each test solution was separated by a ZORBAX Eclipse plus C_(18) column with acetonitrile and 5 mmol/L ammonium acetate as mobile phases,and determined with electrospray ionization and multiple reaction monitoring.[Results]The method had good linearity in the concentration range of 1.0-50 ng/ml,and the correlation coefficient was 0.9997.The limit of detection was 0.25μg/kg and the limit of quantification was 0.75μg/kg.The recovery was between 87.4%and 112.5%,and the RSD%was between 0.5%and 10.0%.[Conclusions]The method has simple operation and high sensitivity,and is suitable for trace detection of sodium pentachlorophenoxide in large quantities of animal-derived food.
基金Supported by The Fourth Batch of High-end Talent Project in Hebei ProvinceTangshan Science and Technology Entrepreneurship and Innovation Leading Talent Project(21130243A).
文摘[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton.
文摘An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.
基金supported by the Preventive medicine and public health research project of Anhui,China(No.2011Y0103)the Natural Science Foundation of Anhui,China(No.11040606M216)
文摘To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY17C200009)the Foundation of Zhejiang Educational Committee(No.Y201328477)
文摘A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
文摘Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
基金supported by the operating grant of the Collaborative Health Research Project,Natural Sciences and Engineering Research Council of Canada,and Canadian Institute of Health Research(CHRPJ 385967).
文摘A highly sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of vancomycin (VAN) in low volumes of rabbit serum. For each analysis, 2 μL rabbit serum was precipitated with methanol that contained the internal standard teicoplanin (TEI). The supernatant was transferred into a 384 well-plate, diluted with water, covered with a pierceable silicone mat and 5 μL was analyzed in positive ionization mode. The UHPLC-MS/MS consisted of an Agilent 1290 Infinity UHPLC system connected to an AB Sciex QTrap®5500 hybrid linear ion-trap triple quadrupole mass spectrometer equipped with a Turbo Spray source. Chromatographic separation was achieved using a Waters Acquity UPLC BEH C18 (1.7 μm, 2.1 mm × 100 mm) column, a VanGuard (1.7 μm, 2.1 × 5 mm) guard column and a mobile phase of water and methanol both containing 5 mM ammonium acetate with 0.1% formic acid. VAN was quantified with multiple reaction monitoring using the transitions of m/z 725.5/144.2, and TEI was monitored at m/z 940.6/316.4. The accuracy, precision, linearity, range and lower limit of quantification (LLOQ) were determined. The accuracy was ≤9.93% and the precision was ≤10.6%. The range was established as 0.1 to 40 μg·mL-1. The LLOQ was 0.1 μg·mL-1 VAN requiring 2 μL of sample with an accuracy of -20.2% and precision of 8.39%. The method was applied successfully to determine the VAN concentrations in rabbit serum after the i.v. administration of VAN via implanted ear catheters.
基金Supported by Young Scientists Research Program (No. 2009507)the Key Laboratory of Marine Bioactive Substances and Modern Analytical Techniques (No. MBSMAT-2010-04),SOA of China
文摘Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasis MCX cartridges. Chromatographic separation on a Cr8 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid. Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L. The precision of the method, calculated as relative standard deviation (RSD), was below 14.6% for all the compounds. The limits of detection (LODs) varied from 0.45 pg to 7.97 pg. The method was applied to detemaine the target analytes in coastal waters of the Yellow Sea in Liaoning, China. Among the tested antibiotics, 31 were found in coastal 'waters, with their concentrations between the LOD and 212.5 ng/L. These data indicate that this method is valid for analysis of antibiotics in coastal waters. The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning, and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems
基金Supported by Key Scientific and Technological Research Project in Higher Education Institutions of Henan Province(17A350002)Project of National Natural Science Foundation of China(81172953)
文摘[Objectives] To study the chemical components and relative content of Achyranthes bidentata leaves and provide a scientific basis for further development and utilization of A. bidentata leaves.[Methods] The chemical components of A. bidentata leaves were rapidly analyzed using the ultra high performance liquid chromatography-time of flight-high resolution mass spectrometry (UHPLC-TOF-MS).[Results] Thirty eight chemical compounds were identified in samples of A. bidentata leaves collected from Wen County of Henan Province, in which seven chemical compounds had the relative content higher than 5%, linoleic acid reached 25.7% and inokosterone A reached 13.8%.[Conclusions] A. bidentata leaves contain many kinds of chemical compounds. This study is expected to provide a certain basis for further extraction of linoleic acid and inokosterone A.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
基金Supported by the National Natural Science Foundation of China(No.30801513)the Knowledge Innovation Program of Chinese Academy of Sciences(No.KSCX2-YW-R-170)
文摘Centrifugal ultrafiltration after methanol extraction of whole plasma was used as an optimal condition for the preparation of blood plasma before metabonomic studies. The plasma samples from 102 lung cancer patients and 34 healthy volunteers were prepared with this approach. With ultra-performance liquid chromatography(UPLC) coupled with quadrupole time-of-flight mass spectrometry(Q-TOF MS) analysis, the samples were investigated in order to find potential disease biomarkers. After data acquisition, orthogonal signal correction partial least squares models were built to differentiate the healthy volunteers from lung cancer patients and to identify metabolites that showed significantly different expression between the two groups. Several metabolite ions were identified as potential biomarkers according to the variable importance in the project(VIP) value in both ion modes. Five lysophosphatidylcholines were further identified as specifically lysoPC 16:0, isomer of lysoPC 16:0, lysoPC 18:0, lysoPC 18:1 and lysoPC 18:2. These results suggest that UPLC coupled with Q-TOF MS is an effective technique for the analysis of plasma metabolites in metabonomic studies.
文摘基于食品基质中松仁过敏原Pin k 2建立了一种超高效液相色谱-串联质谱法。将松仁经过研磨、脱脂、浸提、酶解后经Easy-nLC 1000-QExactive高分辨质谱仪进行分离分析,结合Uniprot蛋白数据库以及ProteinPilotTM软件对质谱图进行数据处理,经BLAST验证特异性,最终筛选3条松仁特异性肽段。方法学验证结果表明,方法在0.001~50mg/mL范围内线性关系良好,定量限为1mg/kg;在饼干、巧克力和饮料3种空白基质中的平均回收率为88.50%~107.57%,相对标准偏差不高于6.08%,基质效应为89.77%~96.13%。该方法具有灵敏度高、特异性好的优势,可应用于饼干、巧克力、饮料等食品样品中松仁过敏原的检测,为我国食品标签真实性检验及食品中隐性过敏原的检测提供技术支持。
文摘Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify and quantify DSP toxins in shellfish. This new methodology could facilitate DSP monitoring and create a means of rapidly responding to incidents threatening public health. In the last years there were different analytical methods for DSP, such as mouse bioassay and LC-FLD. With the development of instrument, Liquid chromatography-mass spectrometry was substituted for other analytical methods with its good sensitivity and selectivity and without derivatization for the determination of DSP. In this report, a high performance liquid chromatogra-phytandem mass spectrometric(HPLC-MS/MS)method was developed for the simultaneous determination of okadaic acid (OA) and dinophysistoxins(DTX1) in Sinonovacula constricta. Optimization of pretreatment experiment was carried out to maximize recoveries and the effectiveness. The analytes were determined under multi-reactions monitoring (MRM) scan type with tandem mass analyzer using negative ion electrospray ionization (-ESI) mode .Finally, the detection and identification of OA and DTX-1 were based upon their retention times (RT) and the fragmentation patterns of their mass spectra. The method of LOQ for the two poisons was 0.02 mg·kg-1.The real sample test showed that this method could be used for sensitive, fast, and accurate determination of the two diarrheic shellfish poisons in shellfish.