Ultra trace determination of lantanum(Ⅲ) has been studied by adsorptive stripping voltammetry methods using an alizarin S as complexing agent and carbon paste electrode as working electrode. The electrode was made ...Ultra trace determination of lantanum(Ⅲ) has been studied by adsorptive stripping voltammetry methods using an alizarin S as complexing agent and carbon paste electrode as working electrode. The electrode was made from mixed of carbon powder and paraffin in micropipette tip with diameter of 4 ram. This method consists of two steps. The first step is the formation and adsorptive accumulation of metal ion with chelator at the electrode surface. The second step is stripping the complex from the electrode surface into the solution. The stripping step generates current which is recorded as voltammogram. The optimum conditions of instrumental parameter obtained were accumulation potential of 600 mV, accumulation time of 120 seconds, and pH of solution of 5.5. In this research, the limit detection obtained was 2.3348 × 10^-12 M (3.24× 10^-11μg/L) with sensitivity of 16.52 (nA/10u M) and the precision of standard solution of La3+ with concentration of 2 × 10^-12 M, 4× 10^-12 M, 6 × 10^-12 M, 8 × 10^-12 M, and 10 × 10^-12M were 3.50%, 9.88%, 7.19%, 7.48% and 1.85% respectively. The linierity of this method is very good with correlation coefficient is 0.9780. Recovery percentage from La3+ with concentration of 6× 10^-12 M and 10 × 10^-12 M are 108.84% and 91.51%, respectively.展开更多
文摘Ultra trace determination of lantanum(Ⅲ) has been studied by adsorptive stripping voltammetry methods using an alizarin S as complexing agent and carbon paste electrode as working electrode. The electrode was made from mixed of carbon powder and paraffin in micropipette tip with diameter of 4 ram. This method consists of two steps. The first step is the formation and adsorptive accumulation of metal ion with chelator at the electrode surface. The second step is stripping the complex from the electrode surface into the solution. The stripping step generates current which is recorded as voltammogram. The optimum conditions of instrumental parameter obtained were accumulation potential of 600 mV, accumulation time of 120 seconds, and pH of solution of 5.5. In this research, the limit detection obtained was 2.3348 × 10^-12 M (3.24× 10^-11μg/L) with sensitivity of 16.52 (nA/10u M) and the precision of standard solution of La3+ with concentration of 2 × 10^-12 M, 4× 10^-12 M, 6 × 10^-12 M, 8 × 10^-12 M, and 10 × 10^-12M were 3.50%, 9.88%, 7.19%, 7.48% and 1.85% respectively. The linierity of this method is very good with correlation coefficient is 0.9780. Recovery percentage from La3+ with concentration of 6× 10^-12 M and 10 × 10^-12 M are 108.84% and 91.51%, respectively.