A simple, fast and reliable method was developed for the analysis of jinggangmycin A (validamycin A) in commercial formulations. The running buffer used was acetate buffer (100 mmol/L, pH 4.7) with 15 kV as the ap...A simple, fast and reliable method was developed for the analysis of jinggangmycin A (validamycin A) in commercial formulations. The running buffer used was acetate buffer (100 mmol/L, pH 4.7) with 15 kV as the applied voltage. The detection was achieved by using direct UV mode at 200 nm and the detection limit was 0.2 μg/mL. Linearity in the concentration range of 5-500 μg/mL was excellent (RE 〉 0.999). The run-to-run repeatability (n = 3), as expressed by the relative standard deviation (RSD) for migration times and peak areas were less than 0.5% and 3.0% respectively. The mean recovery ranged from 97.2% to 101.4%.展开更多
Capillary zone electrophoresis (CZE) is a sensitive and rapid technique for determining traces of inorganic cations in water samples. CZE with indirect UV-diode array detection (CZE-DAD) was utilized to identify sever...Capillary zone electrophoresis (CZE) is a sensitive and rapid technique for determining traces of inorganic cations in water samples. CZE with indirect UV-diode array detection (CZE-DAD) was utilized to identify several inorganic cations in natural, potable, and wastewater samples. A pH 4.35 background electrolyte system was employed and consisted of 15 mM imidazole, 8 mM malonic acid, 2 mM 18-crown-6 ether as complexing agents, 10% v/v methanol as an organic modifier with indirect absorbance reference at 214 nm. The CZE method involved electromigration injection at 5 kV for 5 s, a separation voltage of 20 kV at 25℃, and a detection wavelength of 280 nm. Six main cations (ammonium , potassium K+, calcium Ca2+, sodium Na+, magnesium Mg2+, and lead Pb2+) were tested, and all but lead, were detected in the water samples at concentrations between 0.03 and 755 ppm with a detection limit ranging between 0.023 and 0.084 ppm. The successful evaluation of the proposed methodology allowed us to reliably detect and separate six metal ions in different water samples without any pretreatment. All water samples were collected from Northern New York towns and the Raquette River water system, the third longest river in New York State and the largest watershed of the central and western Adirondacks.展开更多
Glycerides are first separated to classes of triglycerides(TGs), diglycerides(DGs) and monoglycerides(MGs) by normal phase HPLC on silica gel column. Individual triglyceride separation is then achieved by non-aqueous ...Glycerides are first separated to classes of triglycerides(TGs), diglycerides(DGs) and monoglycerides(MGs) by normal phase HPLC on silica gel column. Individual triglyceride separation is then achieved by non-aqueous reversed phase(NARP) HPLC on C_(18) column with UV detection at 215nm.展开更多
Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years.This technology is used in the corona tests of conductor bundles in this paper.In order to further research the ...Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years.This technology is used in the corona tests of conductor bundles in this paper.In order to further research the corona characteristic,optimize geometry parameters and diameter of sub-conductor,and increase corona onset voltage of transmission lines,corona tests of three model conductors which are placed inside the outdoor corona cage are conducted.Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way.Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus.The photon number within unit interval,namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge.According to the apparent change of photon number,corona onset voltage can be judged.All tests are conducted under almost same atmosphere condition.Using the method,corona onset voltage is acquired.The results indicate that the tests have a good repeatability,in other words,repeating same test twice same result can be aquired.The corona onset voltage can be acquired exactly from the curve of applied voltage vs.photon counting rate.Therefore UV detection apparatus can not only used to find discharge point exactly,but also applied on corona discharge research and live detection for power equipments.The method using in this paper is proved that is a new available method.展开更多
Aim To strdy the separation of native amino acids using capillary zone electro- pboresis (CZE) with indirect ultraviolet detecition. Methods 13 native amino acids were sepa- rated by capillary electrophoresis with ind...Aim To strdy the separation of native amino acids using capillary zone electro- pboresis (CZE) with indirect ultraviolet detecition. Methods 13 native amino acids were sepa- rated by capillary electrophoresis with indirect detection . The experiments were carried out with homemade CE apparatus under the following operating conditior conditions: a fused-silica capillary col- umn of 50.0cm effect length and of 75m i.d. was used. 7 organic acids were used as BGAE, and a positive potential of separation in CZE with indirect detection. After optimizing for l3 native amino acids were established. Conclusion The choice of BGAe is an important factor influencing the efficiency of separation in CZE with indiect detection .After optimizing the separation conditions a baseline separation for 13 native amino acids is obtained.展开更多
Corona discharge is a common phenomenon in power transmission lines external insulation, and it may cause serious defect if without effective detection. The ultraviolet (UV) imagery technology has been widely used to ...Corona discharge is a common phenomenon in power transmission lines external insulation, and it may cause serious defect if without effective detection. The ultraviolet (UV) imagery technology has been widely used to detect the corona discharge in industry in recent years, but some influence factors’ functions are not definite. In this paper, the fracture aluminum strands which is common in power transmission lines were used as the electrode model while a SuperB ultraviolet imager were utilized to detect, the photon count rate was detected with different detect distance, electric field, aluminum strands length and UV gain were applied. Then the multivariate regression analysis (MRA) was taken to calculate the function between the photon count and the factors.展开更多
In this article, a detection method for organic explosives by capillary electrophoresis (CE) is developed based on previous detection techniques. Firstly, a buffer solution consisting of 50 mmol·L-1 sodium dodecy...In this article, a detection method for organic explosives by capillary electrophoresis (CE) is developed based on previous detection techniques. Firstly, a buffer solution consisting of 50 mmol·L-1 sodium dodecyl sulfate (SDS), 20 mmol·L-1 sodium tetraborate and 5% methanol was prepared and the UV detection in this buffer solution was conducted for three common organic explosives, including TNT, DNT and PETN. Then, the capillary UV detection method was investigated in terms of the transition time repeatability, the linear relationship between mass concentration and peak area and the limit of detection. The results revealed good reliability and stability of this method. In addition, these samples were characterized by photodiode array detector (PDA) to verify the qualitative results of UV detection.展开更多
The effect of ion implantation, including Ar+ ion with influences (1 × 1013 - 1015 ions/cm2), on the electrical and optical properties of ultrahigh molecular weight polyethylene (UHMWPE) were investigated with pa...The effect of ion implantation, including Ar+ ion with influences (1 × 1013 - 1015 ions/cm2), on the electrical and optical properties of ultrahigh molecular weight polyethylene (UHMWPE) were investigated with particular emphasis placed on the sensor performance to be used in the field of radiation detection. The obtained results focusing on the effect of the different influences showed a significant change in the electrical conductivity, capacitance and loss tangent. The absorption spectra for UHMWPE samples were recorded and the values of the allowed direct and indirect optical energy gap (Eopt)d, (Eopt)in of UHMWPE and energies of the localized states for the virgin and implanted samples were calculated. We found that the optical energy gap values decreased as the radiation dose increased. The results can be explained on the basis of the ion beam radiation-induced damage in the linear chains of UHMWPE, with cross-linking generated after implantation. The observed changes in both the optical and the electrical properties suggest that the UHMWPE film may be considered as an effective material to achieve ion-radiation detection at room temperature.展开更多
目的:对LC-UV和LC-MS在山楂叶多元酚类成分分析中的应用进行方法学比较。方法:采用高效液相色谱并联双检测器(VWD和MSD)法。色谱柱为Lichrospher C18(250×4.6 mm I.D.,5μm);流动相A为乙腈,B为0.5%甲酸溶液,梯度洗脱,0-12 min A由1...目的:对LC-UV和LC-MS在山楂叶多元酚类成分分析中的应用进行方法学比较。方法:采用高效液相色谱并联双检测器(VWD和MSD)法。色谱柱为Lichrospher C18(250×4.6 mm I.D.,5μm);流动相A为乙腈,B为0.5%甲酸溶液,梯度洗脱,0-12 min A由11%-17%,12-30 min A由17%-18%,30-45 min A由18%-40%,45-60 minA由40%-100%;流速为1ml/min,三向分流阀分流进入MSD和VWD进行检测;柱温30℃;进样量10μl。结果:LC-MS灵敏度比HPLC法高10倍以上,在检测样品中微量成分时具有很大的优势;另外,LC-MS是根据tR和m/z两项指标来确定成分的类型,对于某些用LC-UV方法不能得到良好分离的组分或在LC-UV图谱上保留时间与对照品相近的其它成分,可以选用选择性离子检测(SIM)进行分析,能避免这些成分的干扰,因而具有高度的选择性和专属性。而LC-UV法操作简便,成本低,流动相选择面较广,因而分离度往往比LC-MS高,在检测样品中具有较好的紫外吸收、较好的分离度以及含量较高的成分时,LC-UV法以其高精密度和高稳定性完全可以达到LC-MS同样的检测结果。结论:LC-MS和LC-UV在山楂叶多元酚类成分的定量分析方面各有特色,可根据不同的检测指标选用不同的检测器。展开更多
文摘A simple, fast and reliable method was developed for the analysis of jinggangmycin A (validamycin A) in commercial formulations. The running buffer used was acetate buffer (100 mmol/L, pH 4.7) with 15 kV as the applied voltage. The detection was achieved by using direct UV mode at 200 nm and the detection limit was 0.2 μg/mL. Linearity in the concentration range of 5-500 μg/mL was excellent (RE 〉 0.999). The run-to-run repeatability (n = 3), as expressed by the relative standard deviation (RSD) for migration times and peak areas were less than 0.5% and 3.0% respectively. The mean recovery ranged from 97.2% to 101.4%.
文摘Capillary zone electrophoresis (CZE) is a sensitive and rapid technique for determining traces of inorganic cations in water samples. CZE with indirect UV-diode array detection (CZE-DAD) was utilized to identify several inorganic cations in natural, potable, and wastewater samples. A pH 4.35 background electrolyte system was employed and consisted of 15 mM imidazole, 8 mM malonic acid, 2 mM 18-crown-6 ether as complexing agents, 10% v/v methanol as an organic modifier with indirect absorbance reference at 214 nm. The CZE method involved electromigration injection at 5 kV for 5 s, a separation voltage of 20 kV at 25℃, and a detection wavelength of 280 nm. Six main cations (ammonium , potassium K+, calcium Ca2+, sodium Na+, magnesium Mg2+, and lead Pb2+) were tested, and all but lead, were detected in the water samples at concentrations between 0.03 and 755 ppm with a detection limit ranging between 0.023 and 0.084 ppm. The successful evaluation of the proposed methodology allowed us to reliably detect and separate six metal ions in different water samples without any pretreatment. All water samples were collected from Northern New York towns and the Raquette River water system, the third longest river in New York State and the largest watershed of the central and western Adirondacks.
文摘Glycerides are first separated to classes of triglycerides(TGs), diglycerides(DGs) and monoglycerides(MGs) by normal phase HPLC on silica gel column. Individual triglyceride separation is then achieved by non-aqueous reversed phase(NARP) HPLC on C_(18) column with UV detection at 215nm.
基金Project Supported by UHV Transmission and Transformation System Development and Demonstration Program of National Key Tech-nology R&D Program(2006BAA02A04)
文摘Corona discharge is being detected by UV imaging detection technology at home and abroad in recent years.This technology is used in the corona tests of conductor bundles in this paper.In order to further research the corona characteristic,optimize geometry parameters and diameter of sub-conductor,and increase corona onset voltage of transmission lines,corona tests of three model conductors which are placed inside the outdoor corona cage are conducted.Corona cage could be used to simulate the corona activities on transmission lines under a low voltage and different conditions in an effective and economical way.Photon which was created by UV light as a result of corona discharge on conductors is detected by the UV detection apparatus.The photon number within unit interval,namely photon counting rate is adopted as the parameter of quantifying the intensity of corona discharge.According to the apparent change of photon number,corona onset voltage can be judged.All tests are conducted under almost same atmosphere condition.Using the method,corona onset voltage is acquired.The results indicate that the tests have a good repeatability,in other words,repeating same test twice same result can be aquired.The corona onset voltage can be acquired exactly from the curve of applied voltage vs.photon counting rate.Therefore UV detection apparatus can not only used to find discharge point exactly,but also applied on corona discharge research and live detection for power equipments.The method using in this paper is proved that is a new available method.
文摘Aim To strdy the separation of native amino acids using capillary zone electro- pboresis (CZE) with indirect ultraviolet detecition. Methods 13 native amino acids were sepa- rated by capillary electrophoresis with indirect detection . The experiments were carried out with homemade CE apparatus under the following operating conditior conditions: a fused-silica capillary col- umn of 50.0cm effect length and of 75m i.d. was used. 7 organic acids were used as BGAE, and a positive potential of separation in CZE with indirect detection. After optimizing for l3 native amino acids were established. Conclusion The choice of BGAe is an important factor influencing the efficiency of separation in CZE with indiect detection .After optimizing the separation conditions a baseline separation for 13 native amino acids is obtained.
文摘Corona discharge is a common phenomenon in power transmission lines external insulation, and it may cause serious defect if without effective detection. The ultraviolet (UV) imagery technology has been widely used to detect the corona discharge in industry in recent years, but some influence factors’ functions are not definite. In this paper, the fracture aluminum strands which is common in power transmission lines were used as the electrode model while a SuperB ultraviolet imager were utilized to detect, the photon count rate was detected with different detect distance, electric field, aluminum strands length and UV gain were applied. Then the multivariate regression analysis (MRA) was taken to calculate the function between the photon count and the factors.
文摘In this article, a detection method for organic explosives by capillary electrophoresis (CE) is developed based on previous detection techniques. Firstly, a buffer solution consisting of 50 mmol·L-1 sodium dodecyl sulfate (SDS), 20 mmol·L-1 sodium tetraborate and 5% methanol was prepared and the UV detection in this buffer solution was conducted for three common organic explosives, including TNT, DNT and PETN. Then, the capillary UV detection method was investigated in terms of the transition time repeatability, the linear relationship between mass concentration and peak area and the limit of detection. The results revealed good reliability and stability of this method. In addition, these samples were characterized by photodiode array detector (PDA) to verify the qualitative results of UV detection.
文摘The effect of ion implantation, including Ar+ ion with influences (1 × 1013 - 1015 ions/cm2), on the electrical and optical properties of ultrahigh molecular weight polyethylene (UHMWPE) were investigated with particular emphasis placed on the sensor performance to be used in the field of radiation detection. The obtained results focusing on the effect of the different influences showed a significant change in the electrical conductivity, capacitance and loss tangent. The absorption spectra for UHMWPE samples were recorded and the values of the allowed direct and indirect optical energy gap (Eopt)d, (Eopt)in of UHMWPE and energies of the localized states for the virgin and implanted samples were calculated. We found that the optical energy gap values decreased as the radiation dose increased. The results can be explained on the basis of the ion beam radiation-induced damage in the linear chains of UHMWPE, with cross-linking generated after implantation. The observed changes in both the optical and the electrical properties suggest that the UHMWPE film may be considered as an effective material to achieve ion-radiation detection at room temperature.
文摘目的:对LC-UV和LC-MS在山楂叶多元酚类成分分析中的应用进行方法学比较。方法:采用高效液相色谱并联双检测器(VWD和MSD)法。色谱柱为Lichrospher C18(250×4.6 mm I.D.,5μm);流动相A为乙腈,B为0.5%甲酸溶液,梯度洗脱,0-12 min A由11%-17%,12-30 min A由17%-18%,30-45 min A由18%-40%,45-60 minA由40%-100%;流速为1ml/min,三向分流阀分流进入MSD和VWD进行检测;柱温30℃;进样量10μl。结果:LC-MS灵敏度比HPLC法高10倍以上,在检测样品中微量成分时具有很大的优势;另外,LC-MS是根据tR和m/z两项指标来确定成分的类型,对于某些用LC-UV方法不能得到良好分离的组分或在LC-UV图谱上保留时间与对照品相近的其它成分,可以选用选择性离子检测(SIM)进行分析,能避免这些成分的干扰,因而具有高度的选择性和专属性。而LC-UV法操作简便,成本低,流动相选择面较广,因而分离度往往比LC-MS高,在检测样品中具有较好的紫外吸收、较好的分离度以及含量较高的成分时,LC-UV法以其高精密度和高稳定性完全可以达到LC-MS同样的检测结果。结论:LC-MS和LC-UV在山楂叶多元酚类成分的定量分析方面各有特色,可根据不同的检测指标选用不同的检测器。
基金Science Challenge Project(TZ2016004)National Natural Science Foundation of China(21771133,21790374,21906113)+1 种基金Natural Science Foundation of Jiangsu Province(BK20190044)Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)。