To improve the quality of ultrasonic elastography, by taking the advantage of code excitation and frequency compounding, a transmitting-side multi-frequency with coded excitation for elastography (TFCCE) was propose...To improve the quality of ultrasonic elastography, by taking the advantage of code excitation and frequency compounding, a transmitting-side multi-frequency with coded excitation for elastography (TFCCE) was proposed. TFCCE adopts the chirp signal excitation scheme and strikes a balance in the selection of sub-signal bandwidth, the bandwidth overlap and the number of sub-strain image based on theoretical derivation, so as to further improve the quality of elastic image. Experiments have proved that, compared with the other optimizing methods, the elastographyic signal-to-noise ratio(Re-SN) and contrast-to-noise ratio(Re-CN) are improved significantly with different echo signal-to-noise ratios (ReSN) and attenuation coefficients. When ReSN is 50 dB, compared with short pulse, Rc-SN and Re-CN obtained by TFCCE increase by 53% and 143%, respectively. Moreover, in a deeper investigation (85-95 mm), the image has lower strain noise and clear details. When the attenuation coefficient is in the range of 0-1 dB/(cm.MHz), Re-SN and Re-CN obtained by TFCCE can be kept in moderate ranges of 5〈Re-SN〈6.8 and 11.4〈Re-CN〈15.2, respectively. In particular, for higher tissue attenuation, the basic image quality cannot be ensured with short pulse excitation, while mediocre quality strain figure can be obtained by TFCCE. Therefore, the TFCCE technology can effectively improve the elastography quality and can be applied to ultrasonic clinical trials.展开更多
Objective: To study the relationship of the ultrasonic elastography parameter of thyroid carcinoma with the cancer cell growth and neovascularization in lesion tissue. Methods:Patients with thyroid carcinoma who under...Objective: To study the relationship of the ultrasonic elastography parameter of thyroid carcinoma with the cancer cell growth and neovascularization in lesion tissue. Methods:Patients with thyroid carcinoma who underwent surgical resection and were pathologically diagnosed in Dazhu People's Hospital between March 2015 and June 2017 were chosen as the case group, the patients who received ultrasonic examination and were diagnosed with benign thyroid tumor in Dazhu People's Hospital during the same period were selected as the control group, and the ultrasonic elastography parameter strain ratio as well as the oncogene expression and angiogenesis molecule contents in the thyroid carcinoma tissue and adjacent tissue was determined. Results: DMBT1, CCNG2 and Bax mRNA expression as well as ES protein level in thyroid carcinoma tissue were significantly lower than those in adjacent tissue whereas WIP1 and RET/PTC mRNA expression as well as VEGF, vWF and ANG-1 protein levels were significantly higher than those in adjacent tissue;DMBT1, CCNG2 and Bax mRNA expression as well as ES protein level in thyroid carcinoma tissue with strain ratio ≥3.14 were significantly lower than those in thyroid carcinoma tissue with strain ratio <3.14 whereas WIP1 and RET/PTC mRNA expression as well as VEGF, vWF and ANG-1 protein levels were significantly higher than those in thyroid carcinoma tissue with strain ratio <3.14. Conclusion:The testing threshold 3.14 of ultrasonic elastography parameter stain ratio of thyroid carcinoma can accurately assess the vitality of cancer cell growth and neovascularization in lesion tissue.展开更多
Objective: To study the value of transient ultrasonic elastography for evaluating the liver fibrosis and liver function in patients with drug-induced liver injury. Methods: A total of 68 patients with drug-induced liv...Objective: To study the value of transient ultrasonic elastography for evaluating the liver fibrosis and liver function in patients with drug-induced liver injury. Methods: A total of 68 patients with drug-induced liver injury who were treated in our hospital between January 2016 and May 2017 were selected as drug-induced liver injury group, and 50 healthy volunteers who received physical examination in our hospital during the same period were selected as normal control group. The liver transient ultrasonic elastography parameter Stiffness levels as well as serum liver fibrosis index and liver function index contents of two groups of subjects were detected. Pearson test was used to evaluate the correlation of Stiffness levels with liver fibrosis and liver function damage degree in patients with drug-induced liver injury. Results:Stiffness level in drug-induced liver injury group was higher than that in normal control group;serum liver fibrosis indexes HA, LN, CⅣ, PⅢNP and CG contents were higher than those of normal control group;serum liver function indexes ALT, AST, ALP, STB and γ-GT contents were higher than those of normal control group. Conclusion: Transient ultrasonic elastography parameter Stiffness levels increase in patients with drug-induced liver injury, and the specific levels are consistent with the liver fibrosis and liver function damage degree, and can be used as the objective means to evaluate the disease severity.展开更多
Objective: To study the relationship of ultrasonic elastography parameters of cervical cancer with the cancer cell growth and angiogenesis in the lesion tissue. Methods: A total of 110 patients who were diagnosed with...Objective: To study the relationship of ultrasonic elastography parameters of cervical cancer with the cancer cell growth and angiogenesis in the lesion tissue. Methods: A total of 110 patients who were diagnosed with cervical cancer in the hospital between December 2015 and January 2017 were collected as the observation group, 80 patients who received hysteroscopic cervical polyp resection in the hospital during the same period were collected as the control group. The levels of cervical ultrasonic elastography parameters in the two groups were detected, and fluorescence quantitative PCR was used to determine the expression of proliferation genes, apoptosis genes and angiogenesis-related genes in the lesion tissue. Pearson test was used to evaluate the correlation between cervical ultrasonic elastography parameters and the tumor malignancy indexes. Results: Elastic image press release index and strain ratio of local lesion of observation group were significantly higher than those of control group;GBP1 mRNA expression in lesion tissue of observation group was lower than that in lesion tissue of control group while Prdx4, STAT3 and Sp2 mRNA expression were higher than those in lesion tissue of control group;Survivin, FasL and Bcl-2 mRNA expression in lesion tissue of observation group were higher than those in lesion tissue of control group while Fas and Bax mRNA expression were lower than those in lesion tissue of control group;VEGF, MMP-9, COX-2 and HIF-1 mRNA in lesion tissue of observation group were significantly higher than those in lesion tissue of control group. Conclusion: Elastic image press release index and strain ratio of cervical tissue of patients with cervical cancer are higher, and the specific increase is directly correlated with the tumor malignancy.展开更多
AIM: To investigate the clinical application of ultrasonic elastography in quantitative assessment of fatty liver grading. METHODS: A total of 105 patients with fatty liver were divided into mild group (n = 46), moder...AIM: To investigate the clinical application of ultrasonic elastography in quantitative assessment of fatty liver grading. METHODS: A total of 105 patients with fatty liver were divided into mild group (n = 46), moderate group (n = 39), and severe group (n = 20). Forty-five healthy individuals served as a normal control group. All patients who underwent routine ultrasound scan and further ultrasonic elastography were evaluated accordingly to the evaluation standards for ultrasonic elastography. The ratio of surface areas of blue region/total surface area in the desired region was measured. RESULTS: Ultrasonic elastography technique, in comparison to traditional ultrasound, had a rather high consistence in grading of fatty liver [κ value = (95.3%63.6%)/(1%-63.6%) = 0.87, P = 0.001]. The score of ultrasonic elastography increased with the severity of fatty liver with a sensitivity of 97.14% and a specificity of 91.11%. A significant difference was found in the ratio of surface areas of blue regions between different groups (P < 0.05).CONCLUSION: Ultrasonic elastography can be used in quantitative assessment of the severity of fatty liver.展开更多
BACKGROUND The incidence of breast cancer in China is increasing while its mortality rate is decreasing.The annual breast cancer incidence in China is 39.2 million,accounting for two-thirds of the urban population.In ...BACKGROUND The incidence of breast cancer in China is increasing while its mortality rate is decreasing.The annual breast cancer incidence in China is 39.2 million,accounting for two-thirds of the urban population.In China,breast cancer is the fifth most common malignant tumor overall and the most common in women,accounting for 17%of female malignant tumors.AIM To investigate the accuracy of strain ultrasound elastography(SUE)on the evaluation of preoperative neoadjuvant chemotherapy(NAC)in breast cancer.METHODS Overall,90 patients with breast cancer treated at our hospital between January 2018 and February 2019 were selected for this study.The patients received six cycles of NAC with docetaxel,epirubicin,and cyclophosphamide.Surgical treatment was also performed,and pathological reactivity was assessed.The patients were evaluated using conventional ultrasonography and SUE before biopsy.The differences between groups were analyzed to calculate the mean and standard deviation with significance measured using a t-test,while multivariate analysis was performed using logistic regression analysis.RESULTS Of the patients analyzed,20 had a pathological complete remission(pCR)while 70 did not achieve pCR after NAC.The ratio of the elastic strain ratio(SR)and elastic score of 4–5 in patients with pCR were 5.5±1.16 and 15.00%,respectively;these were significantly lower than those in patients without pCR(85%)and significantly higher than in patients without pCR(14%).SR and elastic score 4–5 were independent factors influencing NAC efficacy(OR=0.644,1.426 and 1.366,respectively,P<0.05).SR was positively correlated with elasticity score(rs=0.411,P<0.05).The area under the receiver operator characteristic curve of SR and SR combined with elastic score in predicting patients without pCR was 0.822 and 0.891,respectively(P<0.05).CONCLUSION Strain ultrasonic elastography may be used to evaluate the effects of preoperative NAC in patients with breast cancer.展开更多
Objective:To investigate the correlation between the ultrasonic elastography parameters of cervical cancer and the malignant biological behavior of cancer cells.Methods: A total of 180 patients with cervical cancer wh...Objective:To investigate the correlation between the ultrasonic elastography parameters of cervical cancer and the malignant biological behavior of cancer cells.Methods: A total of 180 patients with cervical cancer who were diagnosed and treated with radical operation in this hospital were selected as research objects, and the cervical cancer tissue and adjacent tissue samples were collected during operation and stored in liquid nitrogen tanks. The ultrasonic elastography strain ratio of cervical cancer and adjacent tissues was detected before operation, and the differences in the expression of genes associated with proliferation, invasion and autophagy were compared. Pearson test was used to evaluate the correlation between the cervical cancer strain ratio and the malignant biological behavior of cancer cells. Results: The strain ratio level of cervical cancer tissue was higher than that of adjacent tissue;expressions of proliferation-related genes AEG-1, TRAF6 and FoxM1 mRNA were higher than those in adjacent tissue whereas expressions of SFRP2, MST1 and Bmi-1 mRNA were lower than those in adjacent tissue;expressions of invasion-related genes ILK, Sox2, Twist, YB-1 and Rab11 mRNA were higher than those in adjacent tissue;expressions of autophagy-related genes ARHI, Beclin1, PULK and PI3KC3 mRNA were lower than those in adjacent tissue.Conclusions: Ultrasonic strain ratio level of cervical cancer is closely related to the proliferation, invasion and autophagy activity of cancer cells, and is positively correlated with the overall malignancy of the tumor.展开更多
Objective:To investigate the correlation of the pathological features of benign and malignant thyroid nodules with ultrasonic elastography parameters.Methods:A total of 176 patients with thyroid tumor who underwent th...Objective:To investigate the correlation of the pathological features of benign and malignant thyroid nodules with ultrasonic elastography parameters.Methods:A total of 176 patients with thyroid tumor who underwent thyroid tumor resection in this hospital between September 2016 and February 2018 were chosen as the research subjects, the 119 patients with thyroid cancer were selected as thyroid cancer group and the 57 patients with thyroid adenoma were selected as thyroid adenoma group. The thyroid cancer-related proliferation gene and thyroid cancer-related invasion gene expression as well as ultrasonic strain ratio in tumor tissues were compared between the two groups, and Pearson test was used to evaluate the correlation between above malignant molecule expression and ultrasonic strain ratio.Results: Thyroid cancer-related proliferation genes FOXA1, YAP and TPX2 mRNA expression in lesion tissues of thyroid cancer group were higher than those of thyroid adenoma group whereas EGCG and PDCD4 mRNA expression were lower than those of thyroid adenoma group;thyroid cancer-related invasion genes BRD4, Twist1, FoxM1 and SIRT1 expression were higher than those of thyroid adenoma group whereas Wortmannin and HIC1 mRNA expression were lower than those of thyroid adenoma group;ultrasonic strain ratio was higher than that of thyroid adenoma group. The Pearson test showed that the proliferation gene and invasion gene expression in thyroid cancer tissues were directly correlated with the ultrasonic strain ratio level.Conclusion: Thyroid cancer-related proliferation gene and invasion gene expression are directly correlated with ultrasonic strain ratio level, and ultrasonic elastography can be the reliable means to judge benign and malignant thyroid nodules.展开更多
目的分析超声E-cervix弹性成像参数与妊娠期高血压孕晚期分娩方式的关系。方法纳入进行产检的孕晚期妊娠期高血压孕产妇100例,所有孕产妇均实施超声E-cervix弹性成像参数检查,所有孕产妇均随访至最终分娩,统计所有孕产妇的分娩方式并依...目的分析超声E-cervix弹性成像参数与妊娠期高血压孕晚期分娩方式的关系。方法纳入进行产检的孕晚期妊娠期高血压孕产妇100例,所有孕产妇均实施超声E-cervix弹性成像参数检查,所有孕产妇均随访至最终分娩,统计所有孕产妇的分娩方式并依据分娩方式分为2组(自然分娩及剖宫产),分析超声超声E-cervix弹性成像参数对妊娠期高血压孕晚期分娩方式选择的影响。结果经随访统计,100例妊娠期高血压孕晚期孕产妇自然分娩共63例,占比63.00%;剖宫产共37例,占37.00%;自然分娩组弹性对比指数(elasticity contrast index,ECI)、宫颈外口应变(external os strain,EOS)值均大于剖宫产组,硬度比值(hardness ratio,HR)、宫颈长度(cervical length,CL)、宫颈内口应变(internal os strain,IOS)、宫颈内外口应变比值(IOS/EOS)值小于剖宫产组,差异有统计学意义(P<0.05);经点二列相关性证实,超声E-cervix弹性成像参数与妊娠期高血压孕晚期分娩方式间的关系呈正相关(P<0.05)。结论超声E-cervix弹性成像参数可评价宫颈组织变化情况,或可作为评价宫颈成熟度的半定量指标,对妊娠期高血压孕晚期分娩方式的选择具有一定的指导意义。展开更多
基金Project(2013GZX0147-3) supported by the Natural Science Foundation of Sichuan Province,China
文摘To improve the quality of ultrasonic elastography, by taking the advantage of code excitation and frequency compounding, a transmitting-side multi-frequency with coded excitation for elastography (TFCCE) was proposed. TFCCE adopts the chirp signal excitation scheme and strikes a balance in the selection of sub-signal bandwidth, the bandwidth overlap and the number of sub-strain image based on theoretical derivation, so as to further improve the quality of elastic image. Experiments have proved that, compared with the other optimizing methods, the elastographyic signal-to-noise ratio(Re-SN) and contrast-to-noise ratio(Re-CN) are improved significantly with different echo signal-to-noise ratios (ReSN) and attenuation coefficients. When ReSN is 50 dB, compared with short pulse, Rc-SN and Re-CN obtained by TFCCE increase by 53% and 143%, respectively. Moreover, in a deeper investigation (85-95 mm), the image has lower strain noise and clear details. When the attenuation coefficient is in the range of 0-1 dB/(cm.MHz), Re-SN and Re-CN obtained by TFCCE can be kept in moderate ranges of 5〈Re-SN〈6.8 and 11.4〈Re-CN〈15.2, respectively. In particular, for higher tissue attenuation, the basic image quality cannot be ensured with short pulse excitation, while mediocre quality strain figure can be obtained by TFCCE. Therefore, the TFCCE technology can effectively improve the elastography quality and can be applied to ultrasonic clinical trials.
文摘Objective: To study the relationship of the ultrasonic elastography parameter of thyroid carcinoma with the cancer cell growth and neovascularization in lesion tissue. Methods:Patients with thyroid carcinoma who underwent surgical resection and were pathologically diagnosed in Dazhu People's Hospital between March 2015 and June 2017 were chosen as the case group, the patients who received ultrasonic examination and were diagnosed with benign thyroid tumor in Dazhu People's Hospital during the same period were selected as the control group, and the ultrasonic elastography parameter strain ratio as well as the oncogene expression and angiogenesis molecule contents in the thyroid carcinoma tissue and adjacent tissue was determined. Results: DMBT1, CCNG2 and Bax mRNA expression as well as ES protein level in thyroid carcinoma tissue were significantly lower than those in adjacent tissue whereas WIP1 and RET/PTC mRNA expression as well as VEGF, vWF and ANG-1 protein levels were significantly higher than those in adjacent tissue;DMBT1, CCNG2 and Bax mRNA expression as well as ES protein level in thyroid carcinoma tissue with strain ratio ≥3.14 were significantly lower than those in thyroid carcinoma tissue with strain ratio <3.14 whereas WIP1 and RET/PTC mRNA expression as well as VEGF, vWF and ANG-1 protein levels were significantly higher than those in thyroid carcinoma tissue with strain ratio <3.14. Conclusion:The testing threshold 3.14 of ultrasonic elastography parameter stain ratio of thyroid carcinoma can accurately assess the vitality of cancer cell growth and neovascularization in lesion tissue.
基金National Natural Science Foundation of China No:81560497.
文摘Objective: To study the value of transient ultrasonic elastography for evaluating the liver fibrosis and liver function in patients with drug-induced liver injury. Methods: A total of 68 patients with drug-induced liver injury who were treated in our hospital between January 2016 and May 2017 were selected as drug-induced liver injury group, and 50 healthy volunteers who received physical examination in our hospital during the same period were selected as normal control group. The liver transient ultrasonic elastography parameter Stiffness levels as well as serum liver fibrosis index and liver function index contents of two groups of subjects were detected. Pearson test was used to evaluate the correlation of Stiffness levels with liver fibrosis and liver function damage degree in patients with drug-induced liver injury. Results:Stiffness level in drug-induced liver injury group was higher than that in normal control group;serum liver fibrosis indexes HA, LN, CⅣ, PⅢNP and CG contents were higher than those of normal control group;serum liver function indexes ALT, AST, ALP, STB and γ-GT contents were higher than those of normal control group. Conclusion: Transient ultrasonic elastography parameter Stiffness levels increase in patients with drug-induced liver injury, and the specific levels are consistent with the liver fibrosis and liver function damage degree, and can be used as the objective means to evaluate the disease severity.
文摘Objective: To study the relationship of ultrasonic elastography parameters of cervical cancer with the cancer cell growth and angiogenesis in the lesion tissue. Methods: A total of 110 patients who were diagnosed with cervical cancer in the hospital between December 2015 and January 2017 were collected as the observation group, 80 patients who received hysteroscopic cervical polyp resection in the hospital during the same period were collected as the control group. The levels of cervical ultrasonic elastography parameters in the two groups were detected, and fluorescence quantitative PCR was used to determine the expression of proliferation genes, apoptosis genes and angiogenesis-related genes in the lesion tissue. Pearson test was used to evaluate the correlation between cervical ultrasonic elastography parameters and the tumor malignancy indexes. Results: Elastic image press release index and strain ratio of local lesion of observation group were significantly higher than those of control group;GBP1 mRNA expression in lesion tissue of observation group was lower than that in lesion tissue of control group while Prdx4, STAT3 and Sp2 mRNA expression were higher than those in lesion tissue of control group;Survivin, FasL and Bcl-2 mRNA expression in lesion tissue of observation group were higher than those in lesion tissue of control group while Fas and Bax mRNA expression were lower than those in lesion tissue of control group;VEGF, MMP-9, COX-2 and HIF-1 mRNA in lesion tissue of observation group were significantly higher than those in lesion tissue of control group. Conclusion: Elastic image press release index and strain ratio of cervical tissue of patients with cervical cancer are higher, and the specific increase is directly correlated with the tumor malignancy.
文摘AIM: To investigate the clinical application of ultrasonic elastography in quantitative assessment of fatty liver grading. METHODS: A total of 105 patients with fatty liver were divided into mild group (n = 46), moderate group (n = 39), and severe group (n = 20). Forty-five healthy individuals served as a normal control group. All patients who underwent routine ultrasound scan and further ultrasonic elastography were evaluated accordingly to the evaluation standards for ultrasonic elastography. The ratio of surface areas of blue region/total surface area in the desired region was measured. RESULTS: Ultrasonic elastography technique, in comparison to traditional ultrasound, had a rather high consistence in grading of fatty liver [κ value = (95.3%63.6%)/(1%-63.6%) = 0.87, P = 0.001]. The score of ultrasonic elastography increased with the severity of fatty liver with a sensitivity of 97.14% and a specificity of 91.11%. A significant difference was found in the ratio of surface areas of blue regions between different groups (P < 0.05).CONCLUSION: Ultrasonic elastography can be used in quantitative assessment of the severity of fatty liver.
文摘BACKGROUND The incidence of breast cancer in China is increasing while its mortality rate is decreasing.The annual breast cancer incidence in China is 39.2 million,accounting for two-thirds of the urban population.In China,breast cancer is the fifth most common malignant tumor overall and the most common in women,accounting for 17%of female malignant tumors.AIM To investigate the accuracy of strain ultrasound elastography(SUE)on the evaluation of preoperative neoadjuvant chemotherapy(NAC)in breast cancer.METHODS Overall,90 patients with breast cancer treated at our hospital between January 2018 and February 2019 were selected for this study.The patients received six cycles of NAC with docetaxel,epirubicin,and cyclophosphamide.Surgical treatment was also performed,and pathological reactivity was assessed.The patients were evaluated using conventional ultrasonography and SUE before biopsy.The differences between groups were analyzed to calculate the mean and standard deviation with significance measured using a t-test,while multivariate analysis was performed using logistic regression analysis.RESULTS Of the patients analyzed,20 had a pathological complete remission(pCR)while 70 did not achieve pCR after NAC.The ratio of the elastic strain ratio(SR)and elastic score of 4–5 in patients with pCR were 5.5±1.16 and 15.00%,respectively;these were significantly lower than those in patients without pCR(85%)and significantly higher than in patients without pCR(14%).SR and elastic score 4–5 were independent factors influencing NAC efficacy(OR=0.644,1.426 and 1.366,respectively,P<0.05).SR was positively correlated with elasticity score(rs=0.411,P<0.05).The area under the receiver operator characteristic curve of SR and SR combined with elastic score in predicting patients without pCR was 0.822 and 0.891,respectively(P<0.05).CONCLUSION Strain ultrasonic elastography may be used to evaluate the effects of preoperative NAC in patients with breast cancer.
基金Projects of Shandong Provincial Natural Science Foundation No:81470127.
文摘Objective:To investigate the correlation between the ultrasonic elastography parameters of cervical cancer and the malignant biological behavior of cancer cells.Methods: A total of 180 patients with cervical cancer who were diagnosed and treated with radical operation in this hospital were selected as research objects, and the cervical cancer tissue and adjacent tissue samples were collected during operation and stored in liquid nitrogen tanks. The ultrasonic elastography strain ratio of cervical cancer and adjacent tissues was detected before operation, and the differences in the expression of genes associated with proliferation, invasion and autophagy were compared. Pearson test was used to evaluate the correlation between the cervical cancer strain ratio and the malignant biological behavior of cancer cells. Results: The strain ratio level of cervical cancer tissue was higher than that of adjacent tissue;expressions of proliferation-related genes AEG-1, TRAF6 and FoxM1 mRNA were higher than those in adjacent tissue whereas expressions of SFRP2, MST1 and Bmi-1 mRNA were lower than those in adjacent tissue;expressions of invasion-related genes ILK, Sox2, Twist, YB-1 and Rab11 mRNA were higher than those in adjacent tissue;expressions of autophagy-related genes ARHI, Beclin1, PULK and PI3KC3 mRNA were lower than those in adjacent tissue.Conclusions: Ultrasonic strain ratio level of cervical cancer is closely related to the proliferation, invasion and autophagy activity of cancer cells, and is positively correlated with the overall malignancy of the tumor.
文摘Objective:To investigate the correlation of the pathological features of benign and malignant thyroid nodules with ultrasonic elastography parameters.Methods:A total of 176 patients with thyroid tumor who underwent thyroid tumor resection in this hospital between September 2016 and February 2018 were chosen as the research subjects, the 119 patients with thyroid cancer were selected as thyroid cancer group and the 57 patients with thyroid adenoma were selected as thyroid adenoma group. The thyroid cancer-related proliferation gene and thyroid cancer-related invasion gene expression as well as ultrasonic strain ratio in tumor tissues were compared between the two groups, and Pearson test was used to evaluate the correlation between above malignant molecule expression and ultrasonic strain ratio.Results: Thyroid cancer-related proliferation genes FOXA1, YAP and TPX2 mRNA expression in lesion tissues of thyroid cancer group were higher than those of thyroid adenoma group whereas EGCG and PDCD4 mRNA expression were lower than those of thyroid adenoma group;thyroid cancer-related invasion genes BRD4, Twist1, FoxM1 and SIRT1 expression were higher than those of thyroid adenoma group whereas Wortmannin and HIC1 mRNA expression were lower than those of thyroid adenoma group;ultrasonic strain ratio was higher than that of thyroid adenoma group. The Pearson test showed that the proliferation gene and invasion gene expression in thyroid cancer tissues were directly correlated with the ultrasonic strain ratio level.Conclusion: Thyroid cancer-related proliferation gene and invasion gene expression are directly correlated with ultrasonic strain ratio level, and ultrasonic elastography can be the reliable means to judge benign and malignant thyroid nodules.
文摘目的分析超声E-cervix弹性成像参数与妊娠期高血压孕晚期分娩方式的关系。方法纳入进行产检的孕晚期妊娠期高血压孕产妇100例,所有孕产妇均实施超声E-cervix弹性成像参数检查,所有孕产妇均随访至最终分娩,统计所有孕产妇的分娩方式并依据分娩方式分为2组(自然分娩及剖宫产),分析超声超声E-cervix弹性成像参数对妊娠期高血压孕晚期分娩方式选择的影响。结果经随访统计,100例妊娠期高血压孕晚期孕产妇自然分娩共63例,占比63.00%;剖宫产共37例,占37.00%;自然分娩组弹性对比指数(elasticity contrast index,ECI)、宫颈外口应变(external os strain,EOS)值均大于剖宫产组,硬度比值(hardness ratio,HR)、宫颈长度(cervical length,CL)、宫颈内口应变(internal os strain,IOS)、宫颈内外口应变比值(IOS/EOS)值小于剖宫产组,差异有统计学意义(P<0.05);经点二列相关性证实,超声E-cervix弹性成像参数与妊娠期高血压孕晚期分娩方式间的关系呈正相关(P<0.05)。结论超声E-cervix弹性成像参数可评价宫颈组织变化情况,或可作为评价宫颈成熟度的半定量指标,对妊娠期高血压孕晚期分娩方式的选择具有一定的指导意义。