期刊文献+
共找到33,420篇文章
< 1 2 250 >
每页显示 20 50 100
Differentiation of focal liver lesions using three-dimensional ultrasonography: Retrospective and prospective studies 被引量:12
1
作者 Kazushi Numata Manabu Morimoto +4 位作者 Akito Nozaki Michio Ueda Masaaki Kondo Satoshi Morita Katsuaki Tanaka 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第17期2109-2119,共11页
AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal li... AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal liver lesions,including 168 hepatocellular carcinomas (HCCs),63 metastases,40 hemangiomas and 11 focal nodular hyperplasias (FNHs),were examined by 3D US with perflubutane-based contrast agent.Tomographic ultrasound images and sonographic angiograms were reconstructed.Among 282 lesions,enhancement patterns of 163 lesions between January 2007 and October 2007 were analyzed retrospectively.Then from November 2007 to May 2008,compared with contrast-enhanced (CE) 2D US,CE 3D US was performed on 119 lesions for prospective differential diagnosis.Sensitivity,specificity,area under receiver operating characteristic curve (Az) and inter-reader agreement were assessed.RESULTS: With the tridimensional view,dominant enhancement patterns were revealed as diffuse enhancement or peripheral ring-like enhancement,followed with washout change for HCCs or metastases,respectively,and peripheral nodular enhancement or diffuse enhancement with spoke-wheel arteries,followed by persistent enhancement for hemangiomas or FNHs,respectively.At CE 3D US,the prospective differentiation of lesions showed sensitivity 92% (mean for two readers),specificity 91% and Az value 0.95 for HCCs,84%,97%,and 0.95 for metastases,91%,98%,and 0.98 for hemangiomas and 80%,99%,and 0.99 for FNHs,respectively,while good to excellent inter-reader agreement was achieved.No significant difference exists between prospective diagnosis accuracy at CE 3D US and that at CE 2D US.CONCLUSION: CE 3D US provides a spatial perspective for liver tumor enhancement,and could help in differentiating focal liver lesions. 展开更多
关键词 three-dimensional ultrasonography Contrast agent LIVER NEOPLASMS
下载PDF
Double contrast-enhanced two-dimensional and three-dimensional ultrasonography for evaluation of gastric lesions 被引量:37
2
作者 Hong Shi Xiu-Hua Yu +7 位作者 Xin-Zhang Guo Yuan Guo Hong Zhang Bin Qian Zhang-Rui Wei Li Li Xian-Chen Wang Zi-Xiang Kong 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第31期4136-4144,共9页
AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging wit... AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging with both oral and intravenous administrations of contrast agents was used to assess gastroscopiclly-confirmed gastric lesions in 46 patients with benign and malignant diseases. Initially, liquid-based ultrasound contrast agent (Xinzhang) was given orally at dose of 500-600 mL for conventional ultrasound examination of the gastric lesions, and then a microbubble-based contrast agent (SonoVue) was injected intravenously at dose of 1.2-2.4 mL in bolus fashion to assess the perfusion pattern of the lesions using contrast imaging modes. The parameters derived from time-intensity curves including the arrival time (AT), time to peak (lq-P), peak intensity (PI) and en- hanced intensity (EI) were measured on the 2D DCUS imaging. 3D DCUS of the lesions was acquired to dem- onstrate the value of this imaging mode. RESULTS: There were 22 cases with benign lesions including chronic gastritis (n= 5), gastric ulcer (n = 9), gastric polyps (n = 3), gastric stromal tumors (n = 5), and 24 cases with malignant lesions including gastric cancer (n = 20), gastric cardia carcinoma (n = 3) and post-operative recurrent gastric cancer (n = 1) in the study, The oral contrast-enhanced ultrasonography (CEUS) imaging of the stomach clearly demonstrated the anatomy of the stomach and morphologic features of gastric lesions, With optimal scanning window and imaging display under oral CEUS, intravenous CEUS clearly showed the perfusion of gastric lesions with various characteristic manifestations. Both 2D and 3D DCUS images clearly demonstrated normal gastric wall as a three-layer structure, from the inside out, hypere- choic mucosa, hypoechoic muscularis and hyperechoic serosa, respectively. There were statistical significant differences of AT (8.68±2.06 vs 10.43 ±2.75, P = 0.017), PI (34.64 ± 6.63 vs 29.58 ± 8.22, P = 0.023) and EI (29.72 ± 6.69 vs 22.66 ± 7.01, P = 0.001) between malignant lesions and normal gastric wall. However, no differences of AT, PI and EI between benign lesions and normal gastric wall tissue were found. 3D DCUS could intuitively display morphological features and vascularities of the lesions with multiplanar and volume views. 3D DCUS imaging provided comprehen- sive information complementary to 2D imaging. The crater or wellhead appearances and feeding vessels as well as distorted nourishing vasculature of gastric carcinoma were better seen with 3D imaging than 2D imaging. CONCLUSION: DCUS imaging can simultaneouslydisplay the anatomic and perfusion features of gastric lesions. 3D DCUS can provide additional information to 2D DCUS for evaluation of gastric lesions. 展开更多
关键词 Contrast-enhanced ultrasonography Gastriclesions Two-dimensional imaging three-dimensionalimaging Contrast media
下载PDF
Prenatal assessment of normal fetal pulmonary grey-scale and lung volume by three-dimensional ultrasonography 被引量:1
3
作者 Zhen Han,Xiao-Ye Zheng,Hong-Wei Yan,Wen-Li Gou Department of Obstetrics and Gynecology,the First Affiliated Hospital,Medical School of Xi’an Jiaotong University,Xi’an 710061,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期270-272,共3页
Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total... Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total of 732 women with normal singleton pregnancies between 28 and 42 weeks of gestation underwent ultrasound examination.The 3-D US equipment with a 3.5-5 MHz transabdominal transducer was used for the fetal biometric measurement.The echogenicity ratio between fetal lung and liver was compared.The fetal lung volume was calculated by the rotational multiplanar technique for volume measurement(VOCAL).Results The right fetal lung volume increased with the increase of gestational age with a linear positive correlation(r=0.884,P<0.01).After 34 weeks,the echogenicity ratio of fetal lung to liver was more than 1.1.Conclusion The echogenicity of lung/liver and fetal lung volume could be used as normal fetal predictable indicators for fetal lung maturity. 展开更多
关键词 fetal lung lung maturity SONOGRAM three-dimensional ultrasonography
下载PDF
Prenatal diagnosis of isolated lateral facial cleft by ultrasonography and three-dimensional printing:A case report 被引量:1
4
作者 Wen-Ling Song Hai-Ou Ma +5 位作者 Yu Nan Yu-Jia Li Na Qi Li-Ying Zhang Xin Xu Yuan-Yi Wang 《World Journal of Clinical Cases》 SCIE 2021年第24期7196-7204,共9页
BACKGROUND Lateral facial clefts are atypical with a low incidence in the facial cleft spectrum.With the development of ultrasonography(US)prenatal screening,such facial malformations can be detected and diagnosed pre... BACKGROUND Lateral facial clefts are atypical with a low incidence in the facial cleft spectrum.With the development of ultrasonography(US)prenatal screening,such facial malformations can be detected and diagnosed prenatally rather than at birth.Although three-dimensional US(3DUS)can render the fetus'face via 3D reconstruction,the 3D images are displayed on two-dimensional screens without field depth,which impedes the understanding of untrained individuals.In contrast,a 3D-printed model of the fetus'face helps both parents and doctors develop a more comprehensive understanding of the facial malformation by creating more interactive aspects.Herein,we present an isolated lateral facial cleft case that was diagnosed via US combined with a 3D-printed model.CASE SUMMARY A 31-year-old G2P1 patient presented for routine prenatal screening at the 22nd wk of gestation.The coronal nostril-lip section of two-dimensional US(2DUS)demonstrated that the fetus'bilateral oral commissures were asymmetrical,and left oral commissure was abnormally wide.The left oblique-coronal section showed a cleft at the left oral commissure which extended to the left cheek.The results of 3DUS confirmed the cleft.Furthermore,we created a model of the fetal face using 3D printing technology,which clearly presented facial malformations.The fetus was diagnosed with a left lateral facial cleft,which was categorized as a No.7 facial cleft according to the Tessier facial cleft classification.The parents terminated the pregnancy at the 24th wk of gestation after parental counseling.CONCLUSION In the diagnostic course of the current case,in addition to the traditional application of 2D and 3DUS,we created a 3D-printed model of the fetus,which enhanced diagnostic evidence,benefited the education of junior doctors,improved parental counseling,and had the potential to guide surgical planning. 展开更多
关键词 Prenatal diagnosis Isolated lateral facial cleft three-dimensional printing Facial malformations ultrasonography Tessier No.7 facial cleft Case report
下载PDF
Clinical Application of Surface Mode on Three-dimensional Ultrasonography: A Preliminary Study
5
作者 徐辉雄 张青萍 +2 位作者 周玉清 乐桂蓉 汪元芳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2000年第2期159-162,共4页
To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipmen... To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipment used here was Voluson 530D 3DUS imaging system and 3D volume trahsducer with frequency being 3. 0-5. 0 MHz. The 3DUS rendering method was surface mode. The results showed that: 1 ) Surface mode of 3DUS could demonstrate clearly the anatomical characteristics of the region-of-interest (ROI) and the inner wall of lesions or organs that contained fluid. The anatomic details, such as location, size, shape, and number of the ROI, could be visualized intuitively; 2) The outer anatomic features (e. g. contour, edge, configuration, etc. ) of some organs or lesions surrounded by fluid could be displayed clearly. It could be concluded that surface mode on 3DUS could provide more diagnostic information than two-dimensional ultrasonography (2DUS) in some cases and could served as a beneficial supplement to ZDUS in clinical practice. 展开更多
关键词 three-dimensional ultrasonography surface mode volume transducer
下载PDF
Antidiastole Value of Three-dimensional Ultrasonography and Power Doppler between Uterine Parenchyma Lumps and Endometrial Cancer:A Retrospective Study 被引量:11
6
作者 Yan ZHANG Jing CHEN +1 位作者 Zeng ZHEN Xiao-yan XU 《Current Medical Science》 SCIE CAS 2019年第5期816-819,共4页
Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensi... Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensional(3D)power Doppler ultrasonography angiography(PDA)between endometrial cancer and uterine parenchyma lumps.The data of the blood flow indices in 3D-PDA including the vascularization index(VI),flow index(FI),and vascularization flow index(VFI)in 40 patients with endometrial cancer and 41 patients with uterine parenchyma lumps(endometrial polyps and submucosal myomas)were retrospectively analysed and compared utilizing Virtual Organ Computer-aided AnaLysis(VOCAL)software.The results showed that all the blood flow parameters(VI,FI,VFI)were significantly higher in women with endometrial cancer than in those with uterine parenchyma lumps(P<0.001).The area under the curve of ROC of VI,FI,and VFI was 0.98,0.84,and 0.97,respectively.Thus,the best predictor of endometrial carcinoma was VI with a sensitivity of 97.0% and a specificity of 91.0%.The optimal cutoff value of VI was 4.06%.Our data demonstrated that all of the blood flow signal parameters(including VI,FI,and VFI)in 3D power Doppler ultrasonography had significant antidiastole values between endometrial cancer and uterine parenchyma lumps to assist clinicians in properly diagnosing patients. 展开更多
关键词 power DOPPLER three-dimensional ultrasound UTERINE PARENCHYMA lump ENDOMETRIAL CARCINOMA BLOOD flow signal parameter
下载PDF
Computed tomography three-dimensional reconstruction in the diagnosis of bleeding small intestinal polyps:A case report
7
作者 Shu-Hui Zhang Ming-Wei Fan +2 位作者 Yan Chen Ying-Bin Hu Cheng-Xia Liu 《World Journal of Clinical Cases》 SCIE 2024年第16期2831-2836,共6页
BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside s... BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy. 展开更多
关键词 Computed tomography three-dimensional reconstruction Capsule endoscopy Single-balloon enteroscopy Gastrointestinal bleeding Case report
下载PDF
Three-Dimensional Ultrasonography in Obstetrics:the Clinical Value
8
作者 徐辉雄 张青萍 +4 位作者 肖先桃 周玉清 闻良珍 许建平 蔡敏 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第1期38-41,47,共5页
To investigate the clinical value of three dimensional ultrasonography (3DUS) in obstetrics, various 3DUS rendering methods including surface mode, transparent mode and multiplanar mode were employed to scan 30 fetus... To investigate the clinical value of three dimensional ultrasonography (3DUS) in obstetrics, various 3DUS rendering methods including surface mode, transparent mode and multiplanar mode were employed to scan 30 fetuses in second and third trimester by using the transabdominal volume transducer. The results showed that surface mode could vividly demonstrate the surface morphologic features of the fetuses, as well as the stereo shape and the spatial relationship among the surface structures. The face, limbs, umbilical cord and outer genitalia of the fetus could be well displayed by surface mode. Transparent mode could reveal the bony structures under the surface, such as ribs, vertebrae, crania, etc. The result was not affected by the sophisticated curvature of these bony structures and the success rate was up to 100 %. When rendered by multiplanar mode, the region of interest (ROI) could be viewed from different directions. It should be concluded that 3DUS could serve as a supplement to two dimensional ultrasonography (2DUS). 3DUS might play an important role in prenatal diagnosis and enhance the diagnostic confidence level of the physicians. 展开更多
关键词 three dimensional ultrasonography FETUS OBSTETRICS prenatal diagnosis
下载PDF
Research on Three-Dimensional Simulation of the Internal Arc Gear Skiving
9
作者 Xiaoqiang WU Rui XUE +9 位作者 Erkuo GUO Dongzhou JIA Taiyan GONG Zengrong LI Haijun YANG Xiaoxue LI Xin JIANG Shuai DING Yong LIU Shitian LI 《Mechanical Engineering Science》 2024年第1期35-40,共6页
Aiming at the problems that the simulation accuracy which is reduced due to the simplification of the model,a three-dimensional simulation method based on solid modeling is being proposed.By analyzing the motion relat... Aiming at the problems that the simulation accuracy which is reduced due to the simplification of the model,a three-dimensional simulation method based on solid modeling is being proposed.By analyzing the motion relationship and positional relationship between the caries knife and the workpiece,the coordinate system of the caries machining was established.With the MATLAB software,the cutting edge model and the blade sweeping surface model of the boring cutter are sequentially established.Boolean operation is performed on the blade swept surface formed by the tooth cutter teeth with time t and the workpiece tooth geometry as well as the undeformed three-dimensional chip geometry model and the instantaneous cogging geometry model are obtained at different times.Through the compare between gear end face simulation tooth profile and the theoretical inner arc tooth profile,we verified the accuracy and rationality of the proposed method. 展开更多
关键词 gear skiving undeformed three-dimensional chips solid modeling
下载PDF
A theory for three-dimensional response of micropolar plates 被引量:1
10
作者 Dianwu HUANG Linghui HE 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第8期1403-1414,共12页
Through combined applications of the transfer-matrix method and asymptotic expansion technique,we formulate a theory to predict the three-dimensional response of micropolar plates.No ad hoc assumptions regarding throu... Through combined applications of the transfer-matrix method and asymptotic expansion technique,we formulate a theory to predict the three-dimensional response of micropolar plates.No ad hoc assumptions regarding through-thickness assumptions of the field variables are made,and the governing equations are two-dimensional,with the displacements and microrotations of the mid-plane as the unknowns.Once the deformation of the mid-plane is solved,a three-dimensional micropolar elastic field within the plate is generated,which is exact up to the second order except in the boundary region close to the plate edge.As an illustrative example,the bending of a clamped infinitely long plate caused by a uniformly distributed transverse force is analyzed and discussed in detail. 展开更多
关键词 micropolar plate TRANSFER-MATRIX asymptotic expansion three-dimensional response
下载PDF
Oxygen tension modulates cell function in an in vitro three-dimensional glioblastoma tumor model 被引量:1
11
作者 Sen Wang Siqi Yao +8 位作者 Na Pei Luge Bai Zhiyan Hao Dichen Li Jiankang He J.Miguel Oliveira Xiaoyan Xue Ling Wang Xinggang Mao 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第3期307-319,共13页
Hypoxia is a typical feature of the tumor microenvironment,one of the most critical factors affecting cell behavior and tumor progression.However,the lack of tumor models able to precisely emulate natural brain tumor ... Hypoxia is a typical feature of the tumor microenvironment,one of the most critical factors affecting cell behavior and tumor progression.However,the lack of tumor models able to precisely emulate natural brain tumor tissue has impeded the study of the effects of hypoxia on the progression and growth of tumor cells.This study reports a three-dimensional(3D)brain tumor model obtained by encapsulating U87MG(U87)cells in a hydrogel containing type I collagen.It also documents the effect of various oxygen concentrations(1%,7%,and 21%)in the culture environment on U87 cell morphology,proliferation,viability,cell cycle,apoptosis rate,and migration.Finally,it compares two-dimensional(2D)and 3D cultures.For comparison purposes,cells cultured in flat culture dishes were used as the control(2D model).Cells cultured in the 3D model proliferated more slowly but had a higher apoptosis rate and proportion of cells in the resting phase(G0 phase)/gap I phase(G1 phase)than those cultured in the 2D model.Besides,the two models yielded significantly different cell morphologies.Finally,hypoxia(e.g.,1%O2)affected cell morphology,slowed cell growth,reduced cell viability,and increased the apoptosis rate in the 3D model.These results indicate that the constructed 3D model is effective for investigating the effects of biological and chemical factors on cell morphology and function,and can be more representative of the tumor microenvironment than 2D culture systems.The developed 3D glioblastoma tumor model is equally applicable to other studies in pharmacology and pathology. 展开更多
关键词 HYPOXIA GLIOMA three-dimensional glioma model In vitro
下载PDF
The combined application of stem cells and three-dimensional bioprinting scaffolds for the repair of spinal cord injury 被引量:3
12
作者 Dingyue Ju Chuanming Dong 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第8期1751-1758,共8页
Spinal cord injury is considered one of the most difficult injuries to repair and has one of the worst prognoses for injuries to the nervous system.Following surgery,the poor regenerative capacity of nerve cells and t... Spinal cord injury is considered one of the most difficult injuries to repair and has one of the worst prognoses for injuries to the nervous system.Following surgery,the poor regenerative capacity of nerve cells and the generation of new scars can make it very difficult for the impaired nervous system to restore its neural functionality.Traditional treatments can only alleviate secondary injuries but cannot fundamentally repair the spinal cord.Consequently,there is a critical need to develop new treatments to promote functional repair after spinal cord injury.Over recent years,there have been seve ral developments in the use of stem cell therapy for the treatment of spinal cord injury.Alongside significant developments in the field of tissue engineering,three-dimensional bioprinting technology has become a hot research topic due to its ability to accurately print complex structures.This led to the loading of three-dimensional bioprinting scaffolds which provided precise cell localization.These three-dimensional bioprinting scaffolds co uld repair damaged neural circuits and had the potential to repair the damaged spinal cord.In this review,we discuss the mechanisms underlying simple stem cell therapy,the application of different types of stem cells for the treatment of spinal cord injury,and the different manufa cturing methods for three-dimensional bioprinting scaffolds.In particular,we focus on the development of three-dimensional bioprinting scaffolds for the treatment of spinal cord injury. 展开更多
关键词 BIOMATERIALS embryonic stem cells induced pluripotent stem cells mesenchymal stem cells nerve regeneration spinal cord injury stem cell therapy stem cells three-dimensional bioprinting
下载PDF
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
13
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
Intraoperative application of three-dimensional printed guides in total hip arthroplasty: A systematic review
14
作者 Tim P Crone Bart M W Cornelissen +2 位作者 Jakob Van Oldenrijk Pieter Koen Bos Ewout S Veltman 《World Journal of Orthopedics》 2024年第7期660-667,共8页
BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular compon... BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning. 展开更多
关键词 Total hip arthroplasty three-dimensional printing Hip replacement surgery three-dimensional planning Surgical guides
下载PDF
Computer-assisted three-dimensional individualized extreme liver resection for hepatoblastoma in proximity to the major liver vasculature
15
作者 Wen-Li Xiu Jie Liu +7 位作者 Jing-Li Zhang Jing-Miao Wang Xue-Feng Wang Fei-Fei Wang Jie Mi Xi-Wei Hao NanXia Qian Dong 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第4期1066-1077,共12页
BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,e... BACKGROUND The management of hepatoblastoma(HB)becomes challenging when the tumor remains in close proximity to the major liver vasculature(PMV)even after a full course of neoadjuvant chemotherapy(NAC).In such cases,extreme liver resection can be considered a potential option.AIM To explore whether computer-assisted three-dimensional individualized extreme liver resection is safe and feasible for children with HB who still have PMV after a full course of NAC.METHODS We retrospectively collected data from children with HB who underwent surgical resection at our center from June 2013 to June 2023.We then analyzed the detailed clinical and three-dimensional characteristics of children with HB who still had PMV after a full course of NAC.RESULTS Sixty-seven children diagnosed with HB underwent surgical resection.The age at diagnosis was 21.4±18.8 months,and 40 boys and 27 girls were included.Fifty-nine(88.1%)patients had a single tumor,39(58.2%)of which was located in the right lobe of the liver.A total of 47 patients(70.1%)had PRE-TEXT III or IV.Thirty-nine patients(58.2%)underwent delayed resection.After a full course of NAC,16 patients still had close PMV(within 1 cm in two patients,touching in 11 patients,compressing in four patients,and showing tumor thrombus in three patients).There were 6 patients of tumors in the middle lobe of the liver,and four of those patients exhibited liver anatomy variations.These 16 children underwent extreme liver resection after comprehensive preoperative evaluation.Intraoperative procedures were performed according to the preoperative plan,and the operations were successfully performed.Currently,the 3-year event-free survival of 67 children with HB is 88%.Among the 16 children who underwent extreme liver resection,three experienced recurrence,and one died due to multiple metastases.CONCLUSION Extreme liver resection for HB that is still in close PMV after a full course of NAC is both safe and feasible.This approach not only reduces the necessity for liver transplantation but also results in a favorable prognosis.Individualized three-dimensional surgical planning is beneficial for accurate and complete resection of HB,particularly for assessing vascular involvement,remnant liver volume and anatomical variations. 展开更多
关键词 Children HEPATOBLASTOMA Surgery three-dimensional COMPUTER-ASSISTED
下载PDF
Influence of sampling on three-dimensional surface shape measurement
16
作者 QIAO Nao-sheng Shang Xue 《中国光学(中英文)》 EI CAS CSCD 北大核心 2024年第6期1512-1520,共9页
In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation o... In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results. 展开更多
关键词 three-dimensional surface shape measurement sampling interval spectra overlapping measurement accuracy
下载PDF
Prediction of three-dimensional ocean temperature in the South China Sea based on time series gridded data and a dynamic spatiotemporal graph neural network
17
作者 Feng Nan Zhuolin Li +3 位作者 Jie Yu Suixiang Shi Xinrong Wu Lingyu Xu 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2024年第7期26-39,共14页
Ocean temperature is an important physical variable in marine ecosystems,and ocean temperature prediction is an important research objective in ocean-related fields.Currently,one of the commonly used methods for ocean... Ocean temperature is an important physical variable in marine ecosystems,and ocean temperature prediction is an important research objective in ocean-related fields.Currently,one of the commonly used methods for ocean temperature prediction is based on data-driven,but research on this method is mostly limited to the sea surface,with few studies on the prediction of internal ocean temperature.Existing graph neural network-based methods usually use predefined graphs or learned static graphs,which cannot capture the dynamic associations among data.In this study,we propose a novel dynamic spatiotemporal graph neural network(DSTGN)to predict threedimensional ocean temperature(3D-OT),which combines static graph learning and dynamic graph learning to automatically mine two unknown dependencies between sequences based on the original 3D-OT data without prior knowledge.Temporal and spatial dependencies in the time series were then captured using temporal and graph convolutions.We also integrated dynamic graph learning,static graph learning,graph convolution,and temporal convolution into an end-to-end framework for 3D-OT prediction using time-series grid data.In this study,we conducted prediction experiments using high-resolution 3D-OT from the Copernicus global ocean physical reanalysis,with data covering the vertical variation of temperature from the sea surface to 1000 m below the sea surface.We compared five mainstream models that are commonly used for ocean temperature prediction,and the results showed that the method achieved the best prediction results at all prediction scales. 展开更多
关键词 dynamic associations three-dimensional ocean temperature prediction graph neural network time series gridded data
下载PDF
Research on Quantitative Identification of Three-Dimensional Connectivity of Fractured-Vuggy Reservoirs
18
作者 Xingliang Deng Peng Cao +3 位作者 Yintao Zhang Yuhui Zhou Xiao Luo Liang Wang 《Energy Engineering》 EI 2024年第5期1195-1207,共13页
The fractured-vuggy carbonate oil resources in the western basin of China are extremely rich.The connectivity of carbonate reservoirs is complex,and there is still a lack of clear understanding of the development and ... The fractured-vuggy carbonate oil resources in the western basin of China are extremely rich.The connectivity of carbonate reservoirs is complex,and there is still a lack of clear understanding of the development and topological structure of the pore space in fractured-vuggy reservoirs.Thus,effective prediction of fractured-vuggy reservoirs is difficult.In view of this,this work employs adaptive point cloud technology to reproduce the shape and capture the characteristics of a fractured-vuggy reservoir.To identify the complex connectivity among pores,fractures,and vugs,a simplified one-dimensional connectivity model is established by using the meshless connection element method(CEM).Considering that different types of connection units have different flow characteristics,a sequential coupling calculation method that can efficiently calculate reservoir pressure and saturation is developed.By automatic history matching,the dynamic production data is fitted in real-time,and the characteristic parameters of the connection unit are inverted.Simulation results show that the three-dimensional connectivity model of the fractured-vuggy reservoir built in this work is as close as 90%of the fine grid model,while the dynamic simulation efficiency is much higher with good accuracy. 展开更多
关键词 Fractured-vuggy reservoir three-dimensional connectivity connection unit dynamic prediction automatic history matching
下载PDF
Effects of three-dimensional quality assessment nursing intervention on efficacy and disease management of patients undergoing esophageal cancer surgery
19
作者 Hai-Yan Wu Jie Jin +3 位作者 Chen Chen Jing-Jing Xu Qi Jiang Dong-Mei Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第9期2979-2985,共7页
BACKGROUND Esophageal cancer is one of the most common malignant tumors.The three-dimensional quality structure model is a quality assessment theory that includes three dimensions:Structure,process,and results.AIM To ... BACKGROUND Esophageal cancer is one of the most common malignant tumors.The three-dimensional quality structure model is a quality assessment theory that includes three dimensions:Structure,process,and results.AIM To investigate the effects of nursing interventions with three-dimensional quality assessment on the efficacy and disease management ability of patients undergoing esophageal cancer surgery.METHODS In this prospective study,the control group received routine nursing,and the intervention group additionally received a three-dimensional quality assessment intervention based on the above routine care.Self-efficacy and patient disease management abilities were evaluated using the General Self-Efficacy Scale(GSES)and Exercise of Self-Care Agency scale,respectively.IBM SPSS Statistics for Windows,version 17.0,was used for the data processing.RESULTS This study recruited 112 patients who were assigned to the control and experi-mental groups(n=56 per group).Before the intervention,there was no significant difference in GSES scores between the two groups(P>0.05).After the inter-vention,the GSES scores of both groups increased,with the experimental group showing higher values(P<0.05).At the time of discharge and three months after discharge,the scores for positive attitudes,self-stress reduction,and total score of health promotion in the experimental group were higher than those in the control group(P<0.05).CONCLUSION The implementation of a three-dimensional quality structure model for postoperative patients with esophageal cancer can effectively improve their self-management ability and self-efficacy of postoperative patients. 展开更多
关键词 Esophageal cancer three-dimensional quality structure model SELF-EFFICACY Disease management ability
下载PDF
Application of three-dimensional speckle tracking technique in measuring left ventricular myocardial function in patients with diabetes
20
作者 Zheng Li Ying Qian +1 位作者 Chun-Yun Fan Yong Huang 《World Journal of Diabetes》 SCIE 2024年第4期783-792,共10页
BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use... BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM. 展开更多
关键词 Diabetes mellitus Left ventricular systolic dysfunction three-dimensional speckle tracking echocardiography Meta analysis
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部