期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Construction of universal calibration model for levofloxacin injections by fiber-optic transmittance-reflectance near-infrared spectroscopy
1
作者 Shao-Rui Hou Yan-Chun Feng +1 位作者 Xue-Bo Zhang Chang-Qin Hu 《Journal of Chinese Pharmaceutical Sciences》 CAS 2012年第1期62-69,共8页
The general strategy and method of constructing universal calibration model for levofioxacin injections by near-infrared spectroscopy have been investigated and discussed. Firstly, a constant-temperature homogeneous l... The general strategy and method of constructing universal calibration model for levofioxacin injections by near-infrared spectroscopy have been investigated and discussed. Firstly, a constant-temperature homogeneous liquid calibration model for levofloxacin hydrochloride injections with the same composition but different active principal ingredient (API) content was established as the basic unit for universal model. Then, samples of levofloxacin hydrochloride injections containing propylene glycol or levofloxacin lactate injections were added to develop a primary constant-temperature liquid universal model. Temperature- amended final universal model was established to apply to samples under different temperatures. The final model was built from 61 calibration samples and 77 validation samples. The value of the root mean square error of cross validation (RMSECV) and coefficient of determination (r2) of leave-one-out cross-validation (LOOCV) were 0.792 and 0.9993, respectively, the root mean square error of prediction (RMSEP) of test set validation (TSV) was 0.87, and the average relative deviation was 1.44%. According to the ICH guidelines, the universal calibration model was evaluated. Based on the experimental statistical results, the recommended number of calibration samples for a constant-temperature homogeneous liquid quantitative model was no less than 15. 展开更多
关键词 Near-infrared spectroscopy Liquid universal calibration model Levofloxacin injection Sampling by fiber-optic transmittance-reflectance mode
原文传递
GEL PERMEATION CHROMATOGRAPHIC ANALYSIS OF LACQUER POLYSACCHARIDE
2
作者 邱星屏 张俐娜 +2 位作者 杜予民 钱保功 吕在民 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1992年第2期137-144,共8页
Ten fractionated samples of Chinese lacquer polysaccharide in aqueous 0.1M NaC1 solution were studied by aqueous-phase gel permeation chromatography (GPC). The universal calibration, broad MWD calibration and correc... Ten fractionated samples of Chinese lacquer polysaccharide in aqueous 0.1M NaC1 solution were studied by aqueous-phase gel permeation chromatography (GPC). The universal calibration, broad MWD calibration and corrected column dispersion were adopted to the analysis of GPC chromatograms of the polysaccharide. The molecular weights M;, M;and polydispersity index M;/M;obtained from GPC are in good agreement with the results of light scattering and membrane osmometry. It is verified that the universal calibration concept is applicable to the lacquer polysaccharide having a number of side chains. 展开更多
关键词 LACQUER POLYSACCHARIDE universal calibration Molecular weight Gel permeation chromatography
下载PDF
A universal method for camera calibration in UITS scenes
3
作者 陈兆学 施鹏飞 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第2期69-72,共4页
A universal approach to camera calibration based on features of some representative lines on traffic ground is presented. It uses only a set of three parallel edges with known intervals and one of their intersected li... A universal approach to camera calibration based on features of some representative lines on traffic ground is presented. It uses only a set of three parallel edges with known intervals and one of their intersected lines with known slope to gain the focal length and orientation parameters of a camera. A set of equations that computes related camera parameters has been derived from geometric properties of the calibration pattern. With accurate analytical implementation, precision of the approach is only decided by accuracy of the calibration target selecting. Final experimental results have showed its validity by a snapshot from real automatic visual traffic surveillance (AVTS) scencs. 展开更多
关键词 LINE A universal method for camera calibration in UITS scenes
原文传递