Both ultra-reliable low latency and high-data-rate communications are required by connective vehicles. Millimeter wave(mm Wave) with large bandwidth is a key technology to support high-data-rate communications. In thi...Both ultra-reliable low latency and high-data-rate communications are required by connective vehicles. Millimeter wave(mm Wave) with large bandwidth is a key technology to support high-data-rate communications. In this paper, the 28 GHz wideband vehicle-to-infrastructure channel is characterized for the urban environment in a major street in Manhattan. The deployment of the transmitter and the receiver, as well as the traffic models, are selected by considering the recommendation by 3GPP TR 37.885. Ray tracing simulator with calibrated electromagnetic parameters is employed in this work to practically conduct intensive simulations. The 3D environment model is reconstructed from OpenStreetMap. The power delay profile, path loss, root-meansquare delay spread, K-factor and so on, are extracted from the calibrated simulation results. The evolution of the parameters, as well as their statistical properties, are analyzed and modeled. The work of this paper helps the researchers understand the propagation channel for designing mmWave technologies and communication system in a similar scenario.展开更多
The coal is largely used for generation of energy in the India, and their huge exploitations cause contamination of the soil. In the present work, the inorganic contamination of surface soil in the coal basin of the c...The coal is largely used for generation of energy in the India, and their huge exploitations cause contamination of the soil. In the present work, the inorganic contamination of surface soil in the coal basin of the country, Korba is described. The concentration of elements i.e. C, O, S, Cl, Na, Mg, Al, Si, P, K, Ca, Ti, Fe, Mn and Ni in the surface soils (n = 30) was analysed by technique i.e. scanning electron microscope-energy dispersive X-ray spectroscopy (SEM-EDX), ranged from 6.6% - 36.4%, 37.8% - 54.3%, 0.07% - 0.39%, 0.03% - 0.25%, 0.10% - 0.39%, 0.12% - 0.49%, 3.7% - 10.3%, 12.2% - 24.4%, 0.11% - 0.60%, 0.68% - 3.22%, 0.8% - 2.7%, 0.25% - 0.61%, 2.3% - 6.4%, 0.08% - 0.22% and 0.04% - 0.16% with mean value (p = 0.05) of 18.8% ± 2.7%, 49.0% ± 1.5%, 0.18% ± 0.03%, 0.11% ± 0.02%, 0.23% ± 0.03%, 0.32% ± 0.03%, 6.1% ± 0.5%, 16.9% ± 0.9%, 0.27% ± 0.04%, 1.6% ± 0.2%, 1.5% ± 0.2%, 0.41% ± 0.03%, 4.3% ± 0.4%, 0.14% ± 0.02% and 0.08% ± 0.01%, respectively. The surface soil morphology, concentration variation of elements, pollution indices and contaminant sources in the soil are discussed.展开更多
Urban pollution has now become increasingly recognized as an important determinant of air pollution in developed countries. The effect of urban air pollution in developing countries, on the other hand, has not been ad...Urban pollution has now become increasingly recognized as an important determinant of air pollution in developed countries. The effect of urban air pollution in developing countries, on the other hand, has not been adequately addressed in the data Spatio-temporal time series. Thus, this study was intended to characterize the effect of urbanization on air pollution for an urbanized Klang Valley, Malaysia using Spatio-temporal data from 2008 to 2017. The Air Pollution Index (API) data and local pollutant concentration were employed to establish the links between urban air pollution. The analysis will be supported by determining the source of pollutants during the study period using</span></span><span><span><span style="font-family:""> Principal Component Analysis (PCA)</span></span></span><span><span><span style="font-family:"">.</span></span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:"">The study identified </span></span></span><span><span><span style="font-family:"">that Carbon monoxide (CO), Nitrogen Dioxide (NO<sub>2</sub>), and Ozone (O<sub>3</sub>) are </span></span></span><span><span><span style="font-family:"">the major air pollution that has contributed to degrading air quality in the Klang Valley due to the vehicles, combustion process, and industries.展开更多
PM10 was monitored during 2008-2011 period at LUT and BON, two urban tropical stations close to each other at Saint-Pierre city, in Reunion Island (south-western Indian Ocean). During the study period, notable PM10 co...PM10 was monitored during 2008-2011 period at LUT and BON, two urban tropical stations close to each other at Saint-Pierre city, in Reunion Island (south-western Indian Ocean). During the study period, notable PM10 concentrations are observed at BON close to the coasts. At LUT, a more inland site, the daily PM10 concentration range between 13 and 70 μg/m3. Importantly, the limit value for the protection of the human health is systematically exceeded at BON while it is never exceeded at LUT. Also, the quality objective (QO: 30 μg/m3, on annual average) and the limit value for the human health protection (LV: 40 μg/m3, on annual average) are exceeded at BON each year during 2008-2011, while at LUT no regulatory values are exceeded. Nitrogen dioxide, an atmospheric tracer of anthropogenic activities was also monitored at LUT and BON. The mean diurnal NO2 variation is of the same level and order of magnitude and exhibits a similar pattern at both stations suggesting that distinct sources influence the PM10 at LUT and at BON. Chemical analysis was performed on daily filters sampled in September-November 2011 at the two stations to determine the sea salt contribution on PM10 across Saint-Pierre city. It showed that the sea salt contribution to the PM10 is 55% at BON in September 2011. The sea salt particles are therefore the main cause for the exceedances of the regulatory values of PM10 recorded at BON. The results importantly suggest that the notable PM10 concentrations measured at this urban marine site might have some but minor impact on human health.展开更多
该文采用热水浸提法提取积雪草多糖,并对其进行结构表征和抗氧化活性研究。经过提取纯化得到积雪草多糖[polysaccharide of Centella asiatica(L.)Urban,CAP],相对分子质量为1.81×106Da,其中总糖含量为(91.35±1.12)%,蛋白质...该文采用热水浸提法提取积雪草多糖,并对其进行结构表征和抗氧化活性研究。经过提取纯化得到积雪草多糖[polysaccharide of Centella asiatica(L.)Urban,CAP],相对分子质量为1.81×106Da,其中总糖含量为(91.35±1.12)%,蛋白质含量为(0.72±0.08)%,糖醛酸含量为(16.88±0.53)%,无还原糖;CAP在溶液中的平均粒径为(325.13±6.05)nm,Zeta电位为(-15.24±0.38)mV,结果表明CAP是一种酸性阴离子多糖;离子色谱表明CAP主要由岩藻糖、鼠李糖、阿拉伯糖、半乳糖、葡萄糖、木糖、甘露糖、葡萄糖醛酸、古罗糖醛酸组成,其摩尔比为0.01∶0.14∶0.44∶0.69∶1.00∶0.03∶0.02∶0.06∶0.11。傅里叶变换红外光谱和核磁共振波谱检测表明CAP是一种含有α-糖苷键和β-糖苷键的吡喃型多糖,并检测出5种糖残基,异头氢/碳信号分别为δ 5.36/99.93、5.26/109.45、5.20/107.62、4.60/104.57、4.45/103.65;抗氧化试验表明CAP清除ABTS+·的效果较好,而清除·OH的效果较差。展开更多
基金supported by Institute for Information & communications Technology Promotion(IITP) grant funded by the Korea government(MSIT) (No. 2018-0-00792, QoE improvement of open Wi-Fi on public transportation for the reduction of communication expense)
文摘Both ultra-reliable low latency and high-data-rate communications are required by connective vehicles. Millimeter wave(mm Wave) with large bandwidth is a key technology to support high-data-rate communications. In this paper, the 28 GHz wideband vehicle-to-infrastructure channel is characterized for the urban environment in a major street in Manhattan. The deployment of the transmitter and the receiver, as well as the traffic models, are selected by considering the recommendation by 3GPP TR 37.885. Ray tracing simulator with calibrated electromagnetic parameters is employed in this work to practically conduct intensive simulations. The 3D environment model is reconstructed from OpenStreetMap. The power delay profile, path loss, root-meansquare delay spread, K-factor and so on, are extracted from the calibrated simulation results. The evolution of the parameters, as well as their statistical properties, are analyzed and modeled. The work of this paper helps the researchers understand the propagation channel for designing mmWave technologies and communication system in a similar scenario.
文摘The coal is largely used for generation of energy in the India, and their huge exploitations cause contamination of the soil. In the present work, the inorganic contamination of surface soil in the coal basin of the country, Korba is described. The concentration of elements i.e. C, O, S, Cl, Na, Mg, Al, Si, P, K, Ca, Ti, Fe, Mn and Ni in the surface soils (n = 30) was analysed by technique i.e. scanning electron microscope-energy dispersive X-ray spectroscopy (SEM-EDX), ranged from 6.6% - 36.4%, 37.8% - 54.3%, 0.07% - 0.39%, 0.03% - 0.25%, 0.10% - 0.39%, 0.12% - 0.49%, 3.7% - 10.3%, 12.2% - 24.4%, 0.11% - 0.60%, 0.68% - 3.22%, 0.8% - 2.7%, 0.25% - 0.61%, 2.3% - 6.4%, 0.08% - 0.22% and 0.04% - 0.16% with mean value (p = 0.05) of 18.8% ± 2.7%, 49.0% ± 1.5%, 0.18% ± 0.03%, 0.11% ± 0.02%, 0.23% ± 0.03%, 0.32% ± 0.03%, 6.1% ± 0.5%, 16.9% ± 0.9%, 0.27% ± 0.04%, 1.6% ± 0.2%, 1.5% ± 0.2%, 0.41% ± 0.03%, 4.3% ± 0.4%, 0.14% ± 0.02% and 0.08% ± 0.01%, respectively. The surface soil morphology, concentration variation of elements, pollution indices and contaminant sources in the soil are discussed.
文摘Urban pollution has now become increasingly recognized as an important determinant of air pollution in developed countries. The effect of urban air pollution in developing countries, on the other hand, has not been adequately addressed in the data Spatio-temporal time series. Thus, this study was intended to characterize the effect of urbanization on air pollution for an urbanized Klang Valley, Malaysia using Spatio-temporal data from 2008 to 2017. The Air Pollution Index (API) data and local pollutant concentration were employed to establish the links between urban air pollution. The analysis will be supported by determining the source of pollutants during the study period using</span></span><span><span><span style="font-family:""> Principal Component Analysis (PCA)</span></span></span><span><span><span style="font-family:"">.</span></span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:"">The study identified </span></span></span><span><span><span style="font-family:"">that Carbon monoxide (CO), Nitrogen Dioxide (NO<sub>2</sub>), and Ozone (O<sub>3</sub>) are </span></span></span><span><span><span style="font-family:"">the major air pollution that has contributed to degrading air quality in the Klang Valley due to the vehicles, combustion process, and industries.
文摘PM10 was monitored during 2008-2011 period at LUT and BON, two urban tropical stations close to each other at Saint-Pierre city, in Reunion Island (south-western Indian Ocean). During the study period, notable PM10 concentrations are observed at BON close to the coasts. At LUT, a more inland site, the daily PM10 concentration range between 13 and 70 μg/m3. Importantly, the limit value for the protection of the human health is systematically exceeded at BON while it is never exceeded at LUT. Also, the quality objective (QO: 30 μg/m3, on annual average) and the limit value for the human health protection (LV: 40 μg/m3, on annual average) are exceeded at BON each year during 2008-2011, while at LUT no regulatory values are exceeded. Nitrogen dioxide, an atmospheric tracer of anthropogenic activities was also monitored at LUT and BON. The mean diurnal NO2 variation is of the same level and order of magnitude and exhibits a similar pattern at both stations suggesting that distinct sources influence the PM10 at LUT and at BON. Chemical analysis was performed on daily filters sampled in September-November 2011 at the two stations to determine the sea salt contribution on PM10 across Saint-Pierre city. It showed that the sea salt contribution to the PM10 is 55% at BON in September 2011. The sea salt particles are therefore the main cause for the exceedances of the regulatory values of PM10 recorded at BON. The results importantly suggest that the notable PM10 concentrations measured at this urban marine site might have some but minor impact on human health.
文摘该文采用热水浸提法提取积雪草多糖,并对其进行结构表征和抗氧化活性研究。经过提取纯化得到积雪草多糖[polysaccharide of Centella asiatica(L.)Urban,CAP],相对分子质量为1.81×106Da,其中总糖含量为(91.35±1.12)%,蛋白质含量为(0.72±0.08)%,糖醛酸含量为(16.88±0.53)%,无还原糖;CAP在溶液中的平均粒径为(325.13±6.05)nm,Zeta电位为(-15.24±0.38)mV,结果表明CAP是一种酸性阴离子多糖;离子色谱表明CAP主要由岩藻糖、鼠李糖、阿拉伯糖、半乳糖、葡萄糖、木糖、甘露糖、葡萄糖醛酸、古罗糖醛酸组成,其摩尔比为0.01∶0.14∶0.44∶0.69∶1.00∶0.03∶0.02∶0.06∶0.11。傅里叶变换红外光谱和核磁共振波谱检测表明CAP是一种含有α-糖苷键和β-糖苷键的吡喃型多糖,并检测出5种糖残基,异头氢/碳信号分别为δ 5.36/99.93、5.26/109.45、5.20/107.62、4.60/104.57、4.45/103.65;抗氧化试验表明CAP清除ABTS+·的效果较好,而清除·OH的效果较差。