AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed inc...AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change.展开更多
KVPO_(4)F(KVPF)has been extensively investigated as the potential cathode material for potassium-ion batteries(PIBs)owing to its high theoretical capacity,superior operating voltage,and three-dimensional Kt conduction...KVPO_(4)F(KVPF)has been extensively investigated as the potential cathode material for potassium-ion batteries(PIBs)owing to its high theoretical capacity,superior operating voltage,and three-dimensional Kt conduction pathway.Nevertheless,the electrochemical behavior of KVPF is limited by the inherent poor electronic conductivity of the phosphate framework and unstable electrode/electrolyte interface.To address the above issues,this work proposes an infiltration-calcination method to confine the in-situ grown KVPF into the mesoporous carbon CMK-3(denoted KVPF@CMK-3).The assembled KVPF@CMK-3 nanocomposite features three-dimensional interconnected carbon channels,which not only offer abundant active sites and significantly accelerate K t/electron transport,but also prevent the growth of KVPF nanoparticle agglomerates,hence stabilizing the structure of the material.Additionally,V–F–C bonds are created at the interface of KVPF and CMK-3,which reduce the loss of F and stabilize the electrode interface.Thus,when tested as a cathode material for PIBs,the KVPF@CMK-3 nanocomposite delivers superior reversible capacitiy(103.2 mAh g^(-1) at 0.2 C),outstanding rate performance(90.1 mAh g^(-1) at 20 C),and steady cycling performance(92.2 mAh g^(-1) at 10 C and with the retention of 88.2%after 500 cycles).Moreover,its potassium storage mechanism is further examined by ex-situ XRD and ex-situ XPS techniques.The above synthetic strategy demonstrates the potential of KVPF@CMK-3 to be applied as the cathode for PIBs.展开更多
文摘AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change.
基金This work was supported by the National Natural Science Foundation of China(22179063).
文摘KVPO_(4)F(KVPF)has been extensively investigated as the potential cathode material for potassium-ion batteries(PIBs)owing to its high theoretical capacity,superior operating voltage,and three-dimensional Kt conduction pathway.Nevertheless,the electrochemical behavior of KVPF is limited by the inherent poor electronic conductivity of the phosphate framework and unstable electrode/electrolyte interface.To address the above issues,this work proposes an infiltration-calcination method to confine the in-situ grown KVPF into the mesoporous carbon CMK-3(denoted KVPF@CMK-3).The assembled KVPF@CMK-3 nanocomposite features three-dimensional interconnected carbon channels,which not only offer abundant active sites and significantly accelerate K t/electron transport,but also prevent the growth of KVPF nanoparticle agglomerates,hence stabilizing the structure of the material.Additionally,V–F–C bonds are created at the interface of KVPF and CMK-3,which reduce the loss of F and stabilize the electrode interface.Thus,when tested as a cathode material for PIBs,the KVPF@CMK-3 nanocomposite delivers superior reversible capacitiy(103.2 mAh g^(-1) at 0.2 C),outstanding rate performance(90.1 mAh g^(-1) at 20 C),and steady cycling performance(92.2 mAh g^(-1) at 10 C and with the retention of 88.2%after 500 cycles).Moreover,its potassium storage mechanism is further examined by ex-situ XRD and ex-situ XPS techniques.The above synthetic strategy demonstrates the potential of KVPF@CMK-3 to be applied as the cathode for PIBs.