Vibration Suppression for Active Magnetic Bearings Using Adaptive Filter with Iterative Search Algorithm
1
作者 Jin-Hui Ye Dan Shi +2 位作者 Yue-Sheng Qi Jin-Hui Gao Jian-Xin Shen 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期61-71,共11页
Active Magnetic Bearing(AMB) is a kind of electromagnetic support that makes the rotor movement frictionless and can suppress rotor vibration by controlling the magnetic force. The most common approach to restrain the... Active Magnetic Bearing(AMB) is a kind of electromagnetic support that makes the rotor movement frictionless and can suppress rotor vibration by controlling the magnetic force. The most common approach to restrain the rotor vibration in AMBs is to adopt a notch filter or adaptive filter in the AMB controller. However, these methods cannot obtain the precise amplitude and phase of the compensation current. Thus, they are not so effective in terms of suppressing the vibrations of the fundamental and other harmonic orders over the whole speed range. To improve the vibration suppression performance of AMBs,an adaptive filter based on Least Mean Square(LMS) is applied to extract the vibration signals from the rotor displacement signal. An Iterative Search Algorithm(ISA) is proposed in this paper to obtain the corresponding relationship between the compensation current and vibration signals. The ISA is responsible for searching the compensating amplitude and shifting phase online for the LMS filter, enabling the AMB controller to generate the corresponding compensation force for vibration suppression. The results of ISA are recorded to suppress vibration using the Look-Up Table(LUT) in variable speed range. Comprehensive simulations and experimental validations are carried out in fixed and variable speed range, and the results demonstrate that by employing the ISA, vibrations of the fundamental and other harmonic orders are suppressed effectively. 展开更多
关键词 active Magnetic Bearing(AMB) Adaptive filter Iterative search algorithm Least mean square(LMS) Vibration suppression
下载PDF
DC active power filter based on model predictive control for DC bus overvoltage suppression of accelerator grid power supply 被引量:1
2
作者 张鸿淇 朱帮友 +3 位作者 马少翔 李志恒 张明 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期1-13,共13页
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated... The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly. 展开更多
关键词 CFETR NBI accelerator grid power supply power active filter model predictive control
下载PDF
Invertebrate community characteristics in biologically active carbon filter 被引量:5
3
作者 Xiaowei Li Yufeng Yang +2 位作者 Lijun Liu Jinsong Zhang Qing Wang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第5期648-655,共8页
Biologically active carbon (BAC) system was set up in a water plant of South China during January to December 2007,to study the invertebrate community characteristics of BAC filter.Thirty-seven invertebrate species ... Biologically active carbon (BAC) system was set up in a water plant of South China during January to December 2007,to study the invertebrate community characteristics of BAC filter.Thirty-seven invertebrate species were found,of which 28 belonging to rotifers.Filter operation could lead to an output of invertebrates in high abundances with the filtrate,and the maximum density could reach 5608 individuals/m 3.Average abundances in the effluent water increased in 27-33 folds in comparison to the influent water during the sampling period.Invertebrate community succession had the following trend:filter-feeding animals → small benthic invertebrates → large benthic and resistant invertebrates.Abundances of large-sized invertebrates (copepod adult and oligochaete) at bigger-media column were significantly higher than that at small-media column.The results implied the abundant species diversity of invertebrate in BAC filter.The relationship between invertebrate and biofilm still remain to be studied in detail. 展开更多
关键词 biologically active carbon filter INVERTEBRATE community characteristics filter media
下载PDF
Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter for Mitigation of Current Harmonics with Combined p-q and Id-Iq Control Strategies 被引量:4
4
作者 Mikkili Suresh Anup Kumar Panda Y. Suresh 《Energy and Power Engineering》 2011年第1期43-52,共10页
As more and more variable frequency drives (VFDs), electronic ballasts, battery chargers, and static Var compensators are installed in facilities, the problems related to harmonics are expected to get worse. As a resu... As more and more variable frequency drives (VFDs), electronic ballasts, battery chargers, and static Var compensators are installed in facilities, the problems related to harmonics are expected to get worse. As a result Active power filter (APF) gains much more attention due to excellent harmonic compensation. But still the performance of the active filter seems to be in contradictions with different control strategies. This paper presents detailed analysis to compare and elevate the performance of two control strategies for ex-tracting reference currents of shunt active filters under balanced, un-balanced and non-sinusoidal conditions by using Fuzzy controller. The well known methods, instantaneous real active and reactive power method (p-q) and active and reactive current method (id-iq) are two control methods which are extensively used in active filters. Extensive Simulations are carried out with fuzzy controller for both p-q and Id-Iq methods for different voltage conditions and adequate results were presented. Simulation results validate the superior per-formance of active and reactive current control strategy (id-iq) with fuzzy controller over active and reactive power control strategy (p-q) with fuzzy controller. 展开更多
关键词 HARMONIC Compensation SHUNT active Power filter p-q CONTROL STRATEGY id-iq CONTROL STRATEGY Fuzzy Controller
下载PDF
Design and Operation of the Printing and Dyeing Wastewater Treatment Project by Combination of Coagulation Sedimentation - Hydrolytic Acidification with Aeration Tank - Biological Aerated Filter - Active Sand Filter 被引量:2
5
作者 Dong Qianqian He Qianmei +2 位作者 Yang Jingyuan Peng Yadong Bian Lipo 《Meteorological and Environmental Research》 CAS 2017年第4期84-88,92,共6页
In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics ... In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics and SS,and lots of pollutants difficult to degrade by microorganism. The process and operating parameters of project are optimized and debugged,and its economic and environmental benefits are analyzed.The results show that the process of coagulation sedimentation-hydrolytic acidification with aeration tank-biological aerated filter-active sand filter is applied in Gaoyang Sewage Treatment Plant. The design scale of sewage treatment plant is 120000 m^3/d. The influent is as following: COD is 669mg/L; SS is 424mg/L; NH_3-N is 8.83mg/L; TP is 6.03mg/L. After the process,the best removal rates of COD,SS,NH_3-N and TP are 93. 5%,98. 8%,97. 1% and 96. 2%,respectively. The various indexes of effluent water complied with standard A of the first order in Pollutants Emission Standard of Urban Wastewater Treatment Plant( GB 18918-2002). The processing cost is only 0. 807 yuan/m^3. As a result,the project construction and operation not only improve the environment,but also promote regional economic development. Process design and operating parameters provide an important reference value for the printing and dyeing wastewater treatment industry. 展开更多
关键词 Water pollution control engineering PRINTING and DYEING wastewater Biological aerated filter active sand filter Industrial design
下载PDF
Prediction control of active power filters 被引量:3
6
作者 王莉娜 罗安 《Journal of Central South University of Technology》 2003年第3期260-264,共5页
A prediction method to obtain harmonic reference for active power filter is presented. It is a new use ofthe adaptive predictive filter based on FIR. The delay inherent in digital controller is successfully compensate... A prediction method to obtain harmonic reference for active power filter is presented. It is a new use ofthe adaptive predictive filter based on FIR. The delay inherent in digital controller is successfully compensated by u-sing the proposed method, and the computing load is not very large compared with the conventional method. Moreo-ver, no additional hardware is needed. Its DSP-based realization is also presented, which is characterized by time-va-riant rate sampling, quasi synchronous sampling, and synchronous operation among the line frequency, PWM gener-ating and sampling in A/D unit. Synchronous operation releases the limitation on PWM modulation ratio and guar-antees that the electrical noises resulting from the switching operation of IGBTs do not interfere with the sampledcurrent. The simulation and experimental results verify the satisfactory performance of the proposed method. 展开更多
关键词 active filter PREDICTION method time-variant RATE sampling QUASI SYNCHRONOUS sampling
下载PDF
The Use of LMS and RLS Adaptive Algorithms for an Adaptive Control Method of Active Power Filter 被引量:2
7
作者 Radek Martinek Jan Zidek +4 位作者 Petr Bilik Jakub Manas Jiri Koziorek Zhaosheng Teng He Wen 《Energy and Power Engineering》 2013年第4期1126-1133,共8页
This paper deals with the adaptive control mechanism management meant for shunt active power filters (SAPF). Systems driven this way are designed to improve the quality of electric power (power quality) in industrial ... This paper deals with the adaptive control mechanism management meant for shunt active power filters (SAPF). Systems driven this way are designed to improve the quality of electric power (power quality) in industrial networks. The authors have focused on the implementation of two basic representatives of adaptive algorithms, first, the algorithm with a stochastic LMS (least mean square) gradient adaptation and then an algorithm with recursive RLS (recursive least square) optimal adaptation. The system examined by the authors can be used for non-linear loads for appliances with rapid fluctuations of the reactive and active power consumption. The proposed system adaptively reduces distortion, falls (dip) and changes in a supply voltage (flicker). Real signals for measurement were obtained at a sophisticated, three-phase experimental workplace. The results of executed experiments indicate that, with use of the certain adaptive algorithms, the examined AHC system shows very good dynamics, resulting in a much faster transition during the AHC connection-disconnection or during a change in harmonic load on the network. The actual experiments are evaluated from several points of view, mainly according to a time convergence (convergence time) and mistakes in a stable state error (steady state error) of the investigated adaptive algorithms and finally as a total harmonic distortion (THD). The article presents a comparison of the most frequently used adaptive algorithms. 展开更多
关键词 active Power filters Total HARMONIC DISTORTION Least Mean SQUARE Adaptive filtering RECURSIVE Least SQUARE
下载PDF
A PV powered shunt active power filter for power quality improvement 被引量:3
8
作者 Ayoub Benzahia Rabhi Boualaga +3 位作者 Ammar Moussi Laeid Zellouma Memich Meriem Bouziane Chaima 《Global Energy Interconnection》 2019年第2期143-149,共7页
This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any... This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point(MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels. 展开更多
关键词 active POWER filter(APF) PHOTOVOLTAIC (PV) Direct POWER Control (DPC) MAXIMUM POWER Point Tracking (MPPT)
下载PDF
Open-circuit fault diagnosis and fault tolerance for shunt active power filter 被引量:1
9
作者 彭涛 赵帅 +1 位作者 但汉兵 玉华雄 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第11期2582-2595,共14页
The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is... The open-circuit fault of the power switches in shunt active power filter(SAPF) would exacerbate the harmonic pollution of power grid, and degrade the reliability of the devices and system. A fault diagnosis method is proposed based on reference model and an over-modulation strategy under hardware fault tolerance for SAPF. First, a mathematic model is established for SAPF. Second, the residuals are generated by comparing the outputs of reference model and those of actual model, and open-switch fault is detected and diagnosed by residual evaluation. After that, hardware fault tolerance is performed with the three-phase four-switch(TPFS) topology to isolate the faulty phase. Finally, the over-modulation strategy is proposed to increase the voltage transfer ratio of the TPFS topology. Simulation and experimental results verified the feasibility and effectiveness of the proposed method. 展开更多
关键词 FAULT diagnosis FAULT TOLERANT reference model over-modulation THREE-PHASE four-switch TOPOLOGY SHUNT active power filter
下载PDF
Novel Control Strategy for Multi-Level Active Power Filter without Phase-Locked-Loop 被引量:1
10
作者 Guojun Tan Xuanqin Wu +1 位作者 Hao Li Meng Liu 《Energy and Power Engineering》 2010年第4期262-270,共9页
Active power filter (APF) using novel virtual line-flux-linkage oriented control strategy can not only realizes no phase-locked-loop (PLL) control, but also achieves a good inhibitory effect to interfere. However, the... Active power filter (APF) using novel virtual line-flux-linkage oriented control strategy can not only realizes no phase-locked-loop (PLL) control, but also achieves a good inhibitory effect to interfere. However, there are some problems in the conventional method, such as the error of amplitude, the shift of phase angle and the non-determinacy of initial oriented angle. In this paper, two one-order low-pass filters are adopted instead of the pure integrator in the virtual line-flux-linkage observer, which can steady the phase and amplitude. Furthermore, an original scheme of harmonics detection under the rotating coordinate is advanced based on the simplified space vector pulse width modulation (SVPWM) strategy. Meanwhile, by using the new SVPWM algorithm, the voltage space vector diagram of the three-level inverter can be simplified and applied into that of two-level inverter, and this makes the control for Neutral Point potential easier. 展开更多
关键词 active POWER filter Harmonics Detection Virtual Line-Flux-Linkage Observer active POWER filter Control WITHOUT PHASE-LOCKED-LOOP Space Vector Pulse Width Modulation
下载PDF
Current control for a shunt hybrid active power filter using recursive integral PI 被引量:1
11
作者 Wei ZHAO An LUO Ke PENG Xia DENG 《控制理论与应用(英文版)》 EI 2009年第1期77-80,共4页
This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of d... This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of detection accuracy, time delay of instruction current calculation and phase displacement of output filter. Fuzzy logic based set-point weighing algorithm is combined in the control scheme to enhance its robustness and anti-interference ability. The proposed algorithm is easy to implement for engineering applications and easy to compute. Experiment results have verified the validity of the proposed controller. Furthermore, the proposed recursive integral PI algorithm can also be applied in the control of periodic current as in AC drivers. 展开更多
关键词 Power electronics Shunt hybrid active power filter Recursive integral PI Fuzzy inference
下载PDF
Control of an Active Filter by Duty Cycle Modulation (DCM) for the Harmonic Decontamination of a Three-Phase Electrical Network 被引量:1
12
作者 Théodore Patrice Nna Nna Salomé Ndjakomo Essiane Stève Pérabi Ngoffé 《Journal of Power and Energy Engineering》 2020年第7期1-14,共14页
This paper presents the control of the active filter by Duty Cycle Modulation (DCM) for the harmonic pollution control of a three-phase electrical system. Several research works have preceded this work, but most of th... This paper presents the control of the active filter by Duty Cycle Modulation (DCM) for the harmonic pollution control of a three-phase electrical system. Several research works have preceded this work, but most of them deal with the control by pulse-width modulation and the differences lie around the THD reduction performance, the quality of the wave obtained, the simplicity of the scheme and the cost of the control. For this purpose, we propose a very innovative approach to active filter control which aims at reducing the current THD at a lower rate than pulse-width modulation techniques improving at the same time the wave quality with a more simplified control scheme. First we present the schematic diagram of the active filter, then we present the design of the control of this active filter based on the real and imaginary instantaneous power method which uses the algebraic “Clark” transformation. The Duty Cycle Modulation controller is used to obtain the required control commands to be injected to the inverter. We then developed a simulink model of the active filter to validate this study. The simulations were performed in the Matlab/Simulink environment. The results obtained show a significant improvement on the harmonic current control techniques for the THD of 1.02% which was 26.25%, the elimination of noise in the signal and the simplicity of the control with an easier implementation than the pulse width modulation (PWM) make the Duty Cycle Modulation (DCM) control a very promising tool. 展开更多
关键词 PWM DCM active filter INVERTER
下载PDF
Implementation of PSOANN Optimized PI Control Algorithm for Shunt Active Filter 被引量:1
13
作者 M.Sujith S.Padma 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第3期863-888,共26页
This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI... This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI),series inductor and DC bus and nonlinear load.The proposed hybrid approach is a combination of Particle Swarm Optimization(PSO)and Artificial Neural Network(ANN)termed as PSOANN.The PI controller gain parameters of kp and ki are optimized with the help of PSOANN.The PSOANN improves the accuracy of tuning the gain parameters under steady and dynamic load conditions;thereby it reduces the values of THD within the prescribed limits of IEEE 519.The PSO optimizes the dataset of terminal voltage and DC voltage present in shunt active filter for different load condition.The optimized dataset acts as the input for the controller to predict the optimal gain with minimal error and to generate the optimized control signal for the SAF.The proposed methodology is modelled and simulated with the help of MATLAB/Simulink platform and illustrated the few test cases considered for exhibiting the performance of proposed hybrid controller.The experimental results are measured with developed laboratory prototype and compared with the simulation results to validate the effectiveness of the proposed control methodology. 展开更多
关键词 Artificial neural network particle swarm optimization shunt active filter voltage source inverter total harmonic distortions.
下载PDF
Coordinated Control Strategy for Harmonic Compensation of Multiple Active Power Filters 被引量:1
14
作者 Jianfeng Yang Rende Qi +1 位作者 Yang Liu Yu Ding 《Energy Engineering》 EI 2022年第2期609-620,共12页
In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of acti... In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity. 展开更多
关键词 active power filter collaborative optimization harmonic compensation rate weighting factor communication topology
下载PDF
Sliding Mode Controller for Three-Phase Hybrid Active Power Filter with Photovoltaic Application 被引量:1
15
作者 Ayman Blorfan Jean Mercklé +2 位作者 Damien Flieller Patrice Wira Guy Sturtzer 《Smart Grid and Renewable Energy》 2012年第1期17-26,共10页
This paper presents a new three-phase hybrid active power filter configuration that interconnects a passive high-pass filter in parallel with an active power filter and a photovoltaic system. The proposed configuratio... This paper presents a new three-phase hybrid active power filter configuration that interconnects a passive high-pass filter in parallel with an active power filter and a photovoltaic system. The proposed configuration can improves the filtering performance of the conventional active power filter, as well as simultaneously supply the power from the photovoltaic arrays to the load and utility. This paper will describe the proposed hybrid active power filter control using sliding mode with photovoltaic system. The proposed technique effectively filters harmonics under 1 kHz but also higher frequency to achieve wideband harmonics compensation. The THD of source current is reduced from 30.09% to 1.95%. The result indicates that the sliding mode controller can track the reference signals and have good dynamic characteristics. 展开更多
关键词 Hybrid active Power filter p-q THEOREM PHOTOVOLTAIC BOOST Converter WIDEBAND HARMONIC Compensation
下载PDF
Third-order active-RC complex filter with automatic frequency tuning for ZigBee transceiver applications 被引量:6
16
作者 李迪 井站 +3 位作者 杨银堂 吴笑峰 石佐辰 柳杨 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第3期966-973,共8页
A 3rd-order Butterworth active-RC complex band-pass filter was presented for Zig Bee(IEEE802.15.4) transceiver applications. The filter adopted cascaded complex pole stages to realize the 3 MHz bandwidth with a centre... A 3rd-order Butterworth active-RC complex band-pass filter was presented for Zig Bee(IEEE802.15.4) transceiver applications. The filter adopted cascaded complex pole stages to realize the 3 MHz bandwidth with a centre frequency of 2 MHz which was required by the Zig Bee transceiver applications. An automatic frequency tuning scheme was also designed to accommodate the performance deterioration due to the process, voltage and temperature(PVT) variations. The whole filter is implemented in a 0.18 μm standard process and occupies an area of 1.3 mm×0.6 mm. The current dissipation is 1.2 m A from a 1.8 V single power supply. Measurement results show that the image rejection ratio(IRR) of the filter is 24.1 d B with a pass-band ripple less than 0.3 d B. The adjacent channel rejection is 29.8 d B@7 MHz and alternate channel rejection 47.5 d B@12 MHz, respectively. 展开更多
关键词 有源RC 频率调谐 过滤器 收发器 ZIGBEE 应用 IEEE802 带通滤波器
下载PDF
Carrier phase shifted SPWM based on current sourced multi-modular converter for active power filter 被引量:5
17
作者 王立乔 李建林 张仲超 《Journal of Zhejiang University Science》 EI CSCD 2004年第7期861-866,共6页
A novel current-source active power filter (APF) based on multi-modular converter with carrier phase-shifted SPWM (CPS-SPWM) technique is proposed. With this technique, the effect of equivalent high switching frequenc... A novel current-source active power filter (APF) based on multi-modular converter with carrier phase-shifted SPWM (CPS-SPWM) technique is proposed. With this technique, the effect of equivalent high switching frequency con-verter is obtained with low switching frequency converter. It is very promising in current-source APF that adopt super-conducting magnetic energy storage component. 展开更多
关键词 现行源多模变换器 活性能滤波器 CPS-SPWM 载波相转换SPWM APF
下载PDF
A 4TH ORDER FULLY INTEGRATED ACTIVE RC COMPLEX FILTER WITH NOVEL AUTOMATIC TUNING SYSTEMS 被引量:1
18
作者 Chen Dianyu Qi Feitao Sun Weiming Qin Shicai Xiong Shaozhen 《Journal of Electronics(China)》 2007年第6期854-858,共5页
This letter introduces a 4th order active RC complex filter with 1.5MHz center frequency and 1MHz bandwidth. The total harmonic distortion of the filter is less than –60dB and the image rejection ratio is greater tha... This letter introduces a 4th order active RC complex filter with 1.5MHz center frequency and 1MHz bandwidth. The total harmonic distortion of the filter is less than –60dB and the image rejection ratio is greater than 60dB. A novel technique is also proposed in this letter to automatically adjust the variation of the time constant. The advantages of the proposed method are its high precision and simplicity. Using 5bits control words, the tuning error is less than ±1.6%. 展开更多
关键词 自动旋转系统 计算机技术 设计方案 网络技术
下载PDF
A Improved Shunt-hybrid-type Active Power Filter and Its Control Method 被引量:2
19
作者 ZHOU Ke WANG Kai +2 位作者 LIU Lu TAN Qi CHU Hongbo 《中国电机工程学报》 EI CSCD 北大核心 2012年第30期I0010-I0010,共1页
关键词 混合型有源电力滤波器 并联 控制 注入电路 电能质量 谐波电流 谐波注入 电流注入
下载PDF
Lag compensation errors in active power filters based on DSP controllers
20
作者 WANG, Xuedan JIANG, Jianguo GAO, Baichen 《Mining Science and Technology》 EI CAS 2010年第2期312-316,共5页
The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the det... The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current. 展开更多
关键词 active power filter digital signal processing MODELING compensation error