The gas field in the Bohai Bay Basin is a fractured metamorphic buried-hill reservoir with dual-media characteristics. The retrograde vaporization mechanism observed in this type of gas condensate reservoir differs si...The gas field in the Bohai Bay Basin is a fractured metamorphic buried-hill reservoir with dual-media characteristics. The retrograde vaporization mechanism observed in this type of gas condensate reservoir differs significantly from that observed in sand gas condensate reservoirs. However, studies on improving the recovery of fractured gas condensate reservoirs are limited;thus, the impact of retrograde vaporization on condensate within fractured metamorphic buried-hill reservoirs remains unclear. To address this gap, a series of gas injection experiments are conducted in pressure-volume-temperature(PVT) cells and long-cores to investigate the retrograde vaporization effect of condensate using different gas injection media in fractured gas condensate reservoirs. We analyze the variation in condensate volume, gas-to-oil ratio, and condensate recovery during gas injection and examine the influence of various gas injection media(CO_(2), N_(2), and dry gas) under different reservoir properties and varying gas injection times. The results demonstrate that the exchange of components between injected gas and condensate significantly influences condensate retrograde vaporization in the formation. Compared with dry gas injection and N_(2) injection,CO_(2) injection exhibits a superior retrograde vaporization effect. At a CO_(2) injection volume of 1 PV, the percentage shrinkage volume of condensate is 13.82%. Additionally, at the maximum retrograde condensation pressure, CO_(2) injection can increase the recovery of condensate by 22.4%. However, the condensate recovery is notably lower in fractured gas condensate reservoirs than in homogeneous reservoirs, owing to the creation of dominant gas channeling by fractures, which leads to decreased condensate recovery. Regarding gas injection timing, the effect of gas injection at reservoir pressure on improving condensate recovery is superior to that of gas injection at the maximum retrograde condensation pressure. This research provides valuable guidance for designing gas injection development plans and dynamic tracking adjustments for fractured gas condensate reservoirs.展开更多
Water is the most abundant liquid on the surface of the earth. It is a liquid whose properties are quite surprising, both as a pure liquid and as a solvent. Water is a very cohesive liquid: its melting and vaporizatio...Water is the most abundant liquid on the surface of the earth. It is a liquid whose properties are quite surprising, both as a pure liquid and as a solvent. Water is a very cohesive liquid: its melting and vaporization temperatures are very high for a liquid that is neither ionic nor metallic, and whose molar mass is low. Thus, water remains liquid at atmospheric pressure up to 100C while similar molecules such as H2S, H2Se, H2Te for example would give a vaporization temperature close to 80C. This cohesion is in fact ensured by hydrogen bonds between water molecules. This type of bonds between neighboring molecules, hydrogen bonds, is quite often found in chemistry [1] [2]. Any change in the state of aggregation of a substance occurs with the absorption or release of a certain amount of latent heat of transformation. Latent heat of fusion, vaporization or sublimation is the ratio of the energy supplied as heat to the mass of the substance that is melted, vaporized or sublimated. As a result of the reversibility of the processes, the fusion heat is equal to the heat released in the reverse process: crystallization and solidification heat. And likewise the heat of vaporization is equal to the heat of condensation. This equality of heat is often used to determine experimentally either of these quantities. There are two main measurement methods: 1) Direct measurement using the calorimeter, 2) Indirect measure based on the use of the VantHoff relationship. The objective of this work is to measure the latent heat of water vaporization and verify the compatibility of the experimental values with the values given by the tables using the indirect method.展开更多
Objectives:To compare the depth of thermal necrosis after use of bipolar resection and vaporization technique comparing intra-individually bipolar loop and bipolar button electrodes.Methods:Transurethral resection and...Objectives:To compare the depth of thermal necrosis after use of bipolar resection and vaporization technique comparing intra-individually bipolar loop and bipolar button electrodes.Methods:Transurethral resection and vaporization of the prostate was performed in 55 male patients(260 specimens in total).In a standardized procedure,a bipolar resection loop was used for resection,and a bipolar button electrode was used for vaporization.Both electrodes were applied in each patient,either in the left or in the right lateral lobe.The depth of necrotic zones in the resected or vaporized tissue of each patient was measured in a standardized way by light microscopy.Results:The mean depth with standard deviation of thermal injury caused by the loop electrode was 0.0495±0.0274 mm.The vaporization electrode caused a mean thermal depth with standard deviation of 0.0477±0.0276 mm.The mean difference of necrosis zone depths between the two types of electrodes(PlasmaButtoneresection loop)was 0.0018 mm(p=0.691).Conclusion:For the first time,we present directly measured values of the absolute necrosis zone depth after application of plasma in the transurethral treatment of benign prostatic hyperplasia.The measured values were lower than in all other transurethral procedures.Standardized procedures of measurement and evaluation allow a statistically significant statement that the low necrosis depth in bipolar procedures is independent of the applied electrodes.展开更多
BACKGROUND Rezūm™water vapor therapy is a new minimally invasive endoscopic technology for the management and treatment of benign prostatic hyperplasia.CASE SUMMARY A 63-year-old male presented to our department with...BACKGROUND Rezūm™water vapor therapy is a new minimally invasive endoscopic technology for the management and treatment of benign prostatic hyperplasia.CASE SUMMARY A 63-year-old male presented to our department with severe dysuria,frequency,urgency,and interrupted stream 2 mo after receiving Rezūm™therapy.The symptoms were caused by a retained floating emphysematous necrotic sloughed tissue.We also discovered a persistent bacterial infection that was resistant to parenteral antimicrobial therapy.The treatment of the patient included surgical removal of the necrotic tissue.CONCLUSION Despite the good safety profile and minimal adverse events related to Rezūm™therapy,major complications can still occur.展开更多
Aim: To explore the feasibility and safety of greenlight photoselective vaporization of the prostate (PVP) on high-risk patients presenting with lower urinary tract symptoms suggestive of benign prostatic hyperplas...Aim: To explore the feasibility and safety of greenlight photoselective vaporization of the prostate (PVP) on high-risk patients presenting with lower urinary tract symptoms suggestive of benign prostatic hyperplasia (BPH) and to evaluate their clinical and voiding outcome. Methods: A total of 85 high-risk patients with obstructive BPH underwent PVP with an 80 W potassium-titanyl-phosphate laser, which was delivered through a side-deflecting fiber with a 23 Fr continuous flow cystoscope. Operative time, blood loss, indwelling catheterzation, international prostate symptom score (IPSS), quality of life score (QoL), uroflowmetry, postvoid residual urine volume and short-term complication rates were evaluated for all patients. Results: All patients got through the perioperative period safely. The chief advantages of PVP were: short operative time (25.6 ± 7.6 min), little bleeding loss (56.8 ± 14.3 mL) and short indwelling catheterization (1.6 ± 0.8 d). The IPSS and QoL decreased from (29.6 ± 5.4) and (5.4 ± 0.6) to (9.5 ± 2.6) and (1.3 ± 0.6), respectively. The vast majority of patients were satisfied with voiding outcome. The mean maximal urinary flow rate increased to 17.8 mL/s and postvoid residual urine volume decreased to 55.6 mL. These results are significantly different from preoperative data (P 〈 0.05). No patient required blood transfusion or fluid absorption. There were few complications and very high patient satisfaction after operation. Conclusion: PVP has a short operative time and high tolerance, and is safe, effective and minimally invasive for high-risk patients, therefore it might be considered as a good alternative treatment for high-risk patients with obstructive urinary symptoms as a result of BPH.展开更多
The high concentration of heavy metal (Cu, Cr, Zn, Pb) in tannery sludge causes severe heavy metal emissions in the process of incineration. In the present investigation, the tannery sludge was treated with 85% phosph...The high concentration of heavy metal (Cu, Cr, Zn, Pb) in tannery sludge causes severe heavy metal emissions in the process of incineration. In the present investigation, the tannery sludge was treated with 85% phosphoric acid before the incineration process in the tube furnace to control the heavy metal emissions. The thermal behavior and heavy metal vaporization of pre-treated tannery sludge were investigated, and X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis were also implemente...展开更多
The vaporization ratios of the slurry at various temperature and partial pressure were calculated with the group-contribution method,and then the phase state of the slurry in the residue fluid catalytic cracking(RFCC)...The vaporization ratios of the slurry at various temperature and partial pressure were calculated with the group-contribution method,and then the phase state of the slurry in the residue fluid catalytic cracking(RFCC) disengager was determined.This research could provide some advices on how to select the technological conditions to decrease the coking in the RFCC disengager.The oil gas temperature and the slurry partial pressure had signifi- cant effects on the vaporization ratio of the slurry.Increasing the oil gas temperature and reducing the slurry partial pressure could effectively slow down the coking speed in the RFCC disengager.According to the calculation results, a correlation was established to predict the vaporization ratio of the slurry under different operating conditions.展开更多
Vaporization behavior (1163-1463 K) of lead in the slag system of FeO-CaO-SiO2-Al2O3 with CaC% was examined. A thermodynamic estimation with the principle of Gibbs free energy minimization showed that the major vapo...Vaporization behavior (1163-1463 K) of lead in the slag system of FeO-CaO-SiO2-Al2O3 with CaC% was examined. A thermodynamic estimation with the principle of Gibbs free energy minimization showed that the major vapor species from the sample of the FeO-CaO-SiO2-Al2O3 system+PbO+CaCl2 were metallic Pb, PbCl, PbCl2, and FeCl2, at the experimental temperature range. The experimental results show that the mole ratio of vaporized Cl in lead chlorides to vaporized Pb, simply expressed as Cl/Pb decreases with increasing temperature. The larger Cl/Pb means a larger ratio of gaseous PbCl2, since metallic Pb and PbCl vapors are formed in a similar reduction atmosphere. The evaporation is initially rapid and becomes steady after holding for 10 min. Gaseous PbCl2 is mainly formed during the heating period, and at the holding stage, it reacts with FeO to produce gaseous FeCl2 With regard to slag composition, FeO content and basicity significantly affect the evaporation of lead. High FeO content and high basicity promotes the formation of metallic Pb and PbCI, whereas, it prohibits PbCl2 evaporation.展开更多
To investigate the factors that influence treatment satisfaction after high-power potassium-titanyl-phosphate (KTP) laser vaporization of the prostate, we compared the characteristics between patients who were satis...To investigate the factors that influence treatment satisfaction after high-power potassium-titanyl-phosphate (KTP) laser vaporization of the prostate, we compared the characteristics between patients who were satisfied and those who were not satisfied. In all, 97 patients aged between 53-82 years (median age 67 years) underwent high-power KTP laser vaporization of the prostate for lower urinary tract symptoms due to benign prostatic hyperplasia. At 12 months postoperatively, 60 patients were satisfied with the treatment, whereas 37 were dissatisfied. Although there were no differences in International Prostate Symptom Score (IPSS) values at baseline, the satisfied group scored better in total IPSS at 1, 3, 6, and 12 months postoperatively (P 〈 0.05). At baseline, the maximum flow rate (Qmax) was lower in the dissatisfied group and remained low throughout the follow-up period, with the exception of 1 month postoperatively (P 〈 0.05), compared with the satisfied group. There were no differences in other objective data between the two groups, including post-void residual and the number of voids based on the frequency-volume charts. In a multivariate model, a higher bladder contractility index was associated with a greater likelihood of treatment satisfaction 12 months after high-power KTP laser vaporization (odds ratio 1.024, 95% confidence interval 1.001-1.048, P 〈 0.05). Patients who were not satisfied following the surgery had a smaller improvement in subjective symptoms and Qmax. In addition, our findings suggest that the relative risk of treatment dissatisfaction following high-power KTP laser vaporization was increased in patients with weak detrusor contractility.展开更多
A method for determination of trace rare earth elements in biological sample by ICP-AES with tungsten-spiral electrothermal vaporization(TETV-ICP-AES)sampling has been developed in this work. Several influencing facto...A method for determination of trace rare earth elements in biological sample by ICP-AES with tungsten-spiral electrothermal vaporization(TETV-ICP-AES)sampling has been developed in this work. Several influencing factors including desolvation and vaporization parameters,carrier gas flow rate and ma- trix effect were investigated in detail.Under optimal experimental conditions,the detection limits for La,Nd, Gd,Dy,Ho,Yb,Lu and Y were obtained in the range of 10^(-9)~10^(-11) g,and they are comparable to and,in most instances,better than those for the GFAAS and conventional pneumatic nebulisation-ICP-AES.The precision(RSD)obtained for this method is less than 6%.展开更多
The past literature on the use of vegetable oils as fuel in diesel engine revealed that utilizing vegetable oil fuels in diesel engines may require property changes in the oil or perhaps, some minor engine modificatio...The past literature on the use of vegetable oils as fuel in diesel engine revealed that utilizing vegetable oil fuels in diesel engines may require property changes in the oil or perhaps, some minor engine modifications or operating changes. This study was conducted to search for the effect of atmospheric oxygen on the puffing and bursting phenomena that occur during vegetable oils droplet vaporization process in their use as fuel in diesel engine. The fiber-suspended droplet technique was used, and the normalized square droplet diameter as well as the temperature evolution vicinity the droplet was analyzed. The results show that puffing and bursting phenomena highly depend on oxygen. In presence of atmospheric oxygen, there is an increase of the puffing and bursting intensity and therefore the evaporation rate of the vegetable oil droplets, but in an inert environment or when the environment is oxygen-depleted puffing and bursting phenomena disappearing and make place of a series of explosions with lower magnitude. The lack of oxygen reduces the thermal degradation, polymerization and oxidation reactions and consequently the vaporization rate of vegetable oils droplets;and could therefore lead to the formation of deposits in the form of polymers. This is unsuitable for their use as a fuel in diesel engines. It can also be concluded that atmospheric oxygen has some positive effects on engine performance and emissions when operating with vegetable oil. These results help to address the challenge for the use of alternative fuels such as non-edible vegetable oils.展开更多
A new method for direct determination of lanthanum in solid biological materials by fluorination electrothermal vaporization ICP-AES technique with polytetrafluoroethylene(PTFE) disperser as a fluorination agent has b...A new method for direct determination of lanthanum in solid biological materials by fluorination electrothermal vaporization ICP-AES technique with polytetrafluoroethylene(PTFE) disperser as a fluorination agent has been described. The effect of particle size on the signal intensity of La has been investigated. The vaporization behaviour of lanthanum and the main factors affecting fluorinating vaporization have been observed.Under optimum experimental conditions,the detection limit of La to this method is 2.0 ng/ml,and the RSD is 4.5%.The proposed method has been applied to determining directly trace lanthanum in solid biological standard reference materials without any chemical pretreatment,and the determined values are in good agreement with the certified ones.展开更多
Three series of laboratory vaporization experiments were conducted to investigate the carbon isotope fractionation of low molecular weight hydrocarbons(LMWHs)during their progressive vaporization.In addition to the ...Three series of laboratory vaporization experiments were conducted to investigate the carbon isotope fractionation of low molecular weight hydrocarbons(LMWHs)during their progressive vaporization.In addition to the analysis of a synthetic oil mixture,individual compounds were also studied either as pure single phases or mixed with soil.This allowed influences of mixing effects and diffusion though soil on the fractionation to be elucidated.The LMWHs volatilized in two broad behavior patterns that depended on their molecular weight and boiling point.Vaporization significantly enriched the ^13C present in the remaining components of the C6–C9 fraction,indicating that the vaporization is mainly kinetically controlled;the observed variations could be described with a Rayleigh fractionation model.In contrast,the heavier compounds(n-C10–n-C12)showed less mass loss and almost no significant isotopic fractionation during vaporization,indicating that the isotope characteristics remained sufficiently constant for these hydrocarbons to be used to identify the source of an oil sample,e.g.,the specific oil field or the origin of a spill.Furthermore,comparative studies suggested that matrix effects should be considered when the carbon isotope ratios of hydrocarbons are applied in the field.展开更多
According to graph theory method, new method is proposed for the prediction or vaporization heat at normal boiling point of paraffins with moleeular,atructure, and it is compared with other methods. We predict the. va...According to graph theory method, new method is proposed for the prediction or vaporization heat at normal boiling point of paraffins with moleeular,atructure, and it is compared with other methods. We predict the. vaporization heat at normal boiling point for 57 different paraffins, and that is compared with experimental data, its overall, absolute average deviation is 0.61%. The result is,superior to other methods.展开更多
Using a low power microwave generator(W_(max)=100W) and a Surfatron discharge device, Plasma-polymerized copper phthalocyanine (PPCuPc) film was synthesised from monomer copper phthalocyanine(CuPc) by microwave plasma...Using a low power microwave generator(W_(max)=100W) and a Surfatron discharge device, Plasma-polymerized copper phthalocyanine (PPCuPc) film was synthesised from monomer copper phthalocyanine(CuPc) by microwave plasma chemical vaporization deposition(MPCVD) with Ar as incorporation gas. The film was characterized by FTIR and ESCA. The role of dissociation of chemical bond in the polymerization process and the influence of substrate temperature and material on deposition were investigated in some detail.展开更多
In this study, the vaporization ratio of the 2-μm laser in the prostatic tissue with benign prostatic hyperplasia was examined in vitro, to explore a technique to estimate the clearance rate of prostatic tissue durin...In this study, the vaporization ratio of the 2-μm laser in the prostatic tissue with benign prostatic hyperplasia was examined in vitro, to explore a technique to estimate the clearance rate of prostatic tissue during the transurethral vaporesection of the prostate. A total of 9 fresh prostatic tissue specimens were obtained by open surgery and the wet weight of the prostatic tissue were measured immediately after the sample collection. Under the simulated conditions of transurethral vaporesection of the prostate by 2-μm laser, each prostate gland was completely vaporesected into fragments with a diameter of less than 1.0 cm in vitro tissue were collected and measured. Then After the vaporesection, the whole fragments of prostatic the lost weight of prostatic tissue, the weight of the collected prostatic tissue and the ratio of the lost weight of prostatic tissue to the wet weight of the prostate glandular organ specimen were calculated. The correlation between the weight of collected prostatic tissue and the weight of the whole glandular organ was analyzed. All the experimental procedures were carried out by one operator. Wet weight of the prostatic gland specimen and the weight of the harvested prostatic tissues after the procedure were recorded. With respect to the wet weight of prostate gland specimen, the percentage of the weight of collected prostatic tissue was (34.45±1.51) %, and the percentage of the lost weight of prostatic tissue was (65.55±1.51)%. Satisfactory linear relationship was observed between the weight of collected prostatic tissue and the wet weight of prostate gland specimen [y=3.245x=6.475 (t=15.097, P=0.000)]. It is concluded that under the simulated conditions of transurethral vaporesection of the prostate by 2-μm laser, the vaporization ratio of prostatic tissue can be calculated on the basis of the weight of collected prostatic tissue, and thereby the clearance of prostatic tissue during the formal operation by 2-μm laser could be quantitatively determined.展开更多
A new method for the determination of vanadium in high purity Y2O3 by fluorination assisted electrothermal vaporization-ICP-AES is presented in this paper. After the sample dissolved,the vanadium in the sample solutio...A new method for the determination of vanadium in high purity Y2O3 by fluorination assisted electrothermal vaporization-ICP-AES is presented in this paper. After the sample dissolved,the vanadium in the sample solution was coprecipitated with Bi(PDC)_3 at pH 3. 7. The precipitates were made into a slurry with the fluorinating agent PTFE and directly introduced into the graphite furnace for determination. The analytical results were obtained by aqueous calibration curve method. The detection limit of the method is 1. 1 ng/mL, the RSD is 2. 8% (n=10,1 5 ng/mL vanadium solution), and the recovery of vanadium added to real sample is more than 96%.展开更多
Many research results have revealed that vaporization pressure has important effects on the formation of the keyhole and molten pool during laser welding. In this paper, based on law of conservation of energy, an inno...Many research results have revealed that vaporization pressure has important effects on the formation of the keyhole and molten pool during laser welding. In this paper, based on law of conservation of energy, an innovative physical model is found to calculate the vaporization pressure during laser welding. In this model, vaporization pressure can be calculated according to some characteristics of the spatter particle. These features include the size, velocity and displacement. They can be measured through images taken by high-speed camera. The periods of this pressure also measured by counting opening and closing time of the bottom keyholes. At this welding condition, the typical vaporization pressure is about 20 203 Pa and the period is about 6. 9 ms. The average opening time of bottom keyholes is about 4. 3 ms, and the closing time is about 2. 6 ms.展开更多
A quantitative analysis method of CO_(2) laser treatments promotes laser treatment performance and rapid clinical application of novel treatment devices.The in silico clinical trial approach,which is based on computat...A quantitative analysis method of CO_(2) laser treatments promotes laser treatment performance and rapid clinical application of novel treatment devices.The in silico clinical trial approach,which is based on computational simulation of light-tissue interactions using the mathematical model,can provide quantitative data.Although several simulation methods of laser tissue vaporization with CO_(2) laser treatments have been proposed,validations of the CO_(2) laser wavelength have been insuffcient.In this study,we demonstrated a tissue vaporization simulation using a CO_(2) laser and performed the experimental validation using a hydrogel phantom with constant physical parameters to evaluate the simulation accuracy of the vaporization process.The laser tissue vaporization simulation consists of the calculation of light transport,photothermal conversion,thermal diffusion,and phase change in the tissue.The vaporization width,depth,and area with CO_(2) laser irradiation to a tissue model were simulated.The simulated results differed from the actual vaporization width and depth by approximately 20%and 30%,respectively,because of the solubilization of the hydrogel phantom.Alternatively,the simulation vaporization area for all light irradiation parameters,which is related to the vaporization amount,agreed well with the actual vaporization values.These results suggest that the computational simulation can be used to evaluate the amount of tissue vaporization in the safety and effectiveness analysis of CO_(2) laser treatments.展开更多
文摘The gas field in the Bohai Bay Basin is a fractured metamorphic buried-hill reservoir with dual-media characteristics. The retrograde vaporization mechanism observed in this type of gas condensate reservoir differs significantly from that observed in sand gas condensate reservoirs. However, studies on improving the recovery of fractured gas condensate reservoirs are limited;thus, the impact of retrograde vaporization on condensate within fractured metamorphic buried-hill reservoirs remains unclear. To address this gap, a series of gas injection experiments are conducted in pressure-volume-temperature(PVT) cells and long-cores to investigate the retrograde vaporization effect of condensate using different gas injection media in fractured gas condensate reservoirs. We analyze the variation in condensate volume, gas-to-oil ratio, and condensate recovery during gas injection and examine the influence of various gas injection media(CO_(2), N_(2), and dry gas) under different reservoir properties and varying gas injection times. The results demonstrate that the exchange of components between injected gas and condensate significantly influences condensate retrograde vaporization in the formation. Compared with dry gas injection and N_(2) injection,CO_(2) injection exhibits a superior retrograde vaporization effect. At a CO_(2) injection volume of 1 PV, the percentage shrinkage volume of condensate is 13.82%. Additionally, at the maximum retrograde condensation pressure, CO_(2) injection can increase the recovery of condensate by 22.4%. However, the condensate recovery is notably lower in fractured gas condensate reservoirs than in homogeneous reservoirs, owing to the creation of dominant gas channeling by fractures, which leads to decreased condensate recovery. Regarding gas injection timing, the effect of gas injection at reservoir pressure on improving condensate recovery is superior to that of gas injection at the maximum retrograde condensation pressure. This research provides valuable guidance for designing gas injection development plans and dynamic tracking adjustments for fractured gas condensate reservoirs.
文摘Water is the most abundant liquid on the surface of the earth. It is a liquid whose properties are quite surprising, both as a pure liquid and as a solvent. Water is a very cohesive liquid: its melting and vaporization temperatures are very high for a liquid that is neither ionic nor metallic, and whose molar mass is low. Thus, water remains liquid at atmospheric pressure up to 100C while similar molecules such as H2S, H2Se, H2Te for example would give a vaporization temperature close to 80C. This cohesion is in fact ensured by hydrogen bonds between water molecules. This type of bonds between neighboring molecules, hydrogen bonds, is quite often found in chemistry [1] [2]. Any change in the state of aggregation of a substance occurs with the absorption or release of a certain amount of latent heat of transformation. Latent heat of fusion, vaporization or sublimation is the ratio of the energy supplied as heat to the mass of the substance that is melted, vaporized or sublimated. As a result of the reversibility of the processes, the fusion heat is equal to the heat released in the reverse process: crystallization and solidification heat. And likewise the heat of vaporization is equal to the heat of condensation. This equality of heat is often used to determine experimentally either of these quantities. There are two main measurement methods: 1) Direct measurement using the calorimeter, 2) Indirect measure based on the use of the VantHoff relationship. The objective of this work is to measure the latent heat of water vaporization and verify the compatibility of the experimental values with the values given by the tables using the indirect method.
文摘Objectives:To compare the depth of thermal necrosis after use of bipolar resection and vaporization technique comparing intra-individually bipolar loop and bipolar button electrodes.Methods:Transurethral resection and vaporization of the prostate was performed in 55 male patients(260 specimens in total).In a standardized procedure,a bipolar resection loop was used for resection,and a bipolar button electrode was used for vaporization.Both electrodes were applied in each patient,either in the left or in the right lateral lobe.The depth of necrotic zones in the resected or vaporized tissue of each patient was measured in a standardized way by light microscopy.Results:The mean depth with standard deviation of thermal injury caused by the loop electrode was 0.0495±0.0274 mm.The vaporization electrode caused a mean thermal depth with standard deviation of 0.0477±0.0276 mm.The mean difference of necrosis zone depths between the two types of electrodes(PlasmaButtoneresection loop)was 0.0018 mm(p=0.691).Conclusion:For the first time,we present directly measured values of the absolute necrosis zone depth after application of plasma in the transurethral treatment of benign prostatic hyperplasia.The measured values were lower than in all other transurethral procedures.Standardized procedures of measurement and evaluation allow a statistically significant statement that the low necrosis depth in bipolar procedures is independent of the applied electrodes.
文摘BACKGROUND Rezūm™water vapor therapy is a new minimally invasive endoscopic technology for the management and treatment of benign prostatic hyperplasia.CASE SUMMARY A 63-year-old male presented to our department with severe dysuria,frequency,urgency,and interrupted stream 2 mo after receiving Rezūm™therapy.The symptoms were caused by a retained floating emphysematous necrotic sloughed tissue.We also discovered a persistent bacterial infection that was resistant to parenteral antimicrobial therapy.The treatment of the patient included surgical removal of the necrotic tissue.CONCLUSION Despite the good safety profile and minimal adverse events related to Rezūm™therapy,major complications can still occur.
文摘Aim: To explore the feasibility and safety of greenlight photoselective vaporization of the prostate (PVP) on high-risk patients presenting with lower urinary tract symptoms suggestive of benign prostatic hyperplasia (BPH) and to evaluate their clinical and voiding outcome. Methods: A total of 85 high-risk patients with obstructive BPH underwent PVP with an 80 W potassium-titanyl-phosphate laser, which was delivered through a side-deflecting fiber with a 23 Fr continuous flow cystoscope. Operative time, blood loss, indwelling catheterzation, international prostate symptom score (IPSS), quality of life score (QoL), uroflowmetry, postvoid residual urine volume and short-term complication rates were evaluated for all patients. Results: All patients got through the perioperative period safely. The chief advantages of PVP were: short operative time (25.6 ± 7.6 min), little bleeding loss (56.8 ± 14.3 mL) and short indwelling catheterization (1.6 ± 0.8 d). The IPSS and QoL decreased from (29.6 ± 5.4) and (5.4 ± 0.6) to (9.5 ± 2.6) and (1.3 ± 0.6), respectively. The vast majority of patients were satisfied with voiding outcome. The mean maximal urinary flow rate increased to 17.8 mL/s and postvoid residual urine volume decreased to 55.6 mL. These results are significantly different from preoperative data (P 〈 0.05). No patient required blood transfusion or fluid absorption. There were few complications and very high patient satisfaction after operation. Conclusion: PVP has a short operative time and high tolerance, and is safe, effective and minimally invasive for high-risk patients, therefore it might be considered as a good alternative treatment for high-risk patients with obstructive urinary symptoms as a result of BPH.
基金the Education Ministryof China (No. 305005)the Department of Sci-ence and Technology of Zhejiang Province, China (No.2007C210054)
文摘The high concentration of heavy metal (Cu, Cr, Zn, Pb) in tannery sludge causes severe heavy metal emissions in the process of incineration. In the present investigation, the tannery sludge was treated with 85% phosphoric acid before the incineration process in the tube furnace to control the heavy metal emissions. The thermal behavior and heavy metal vaporization of pre-treated tannery sludge were investigated, and X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis were also implemente...
基金Supported by the National-Natural Science Foundation of China (No.20406013) and Program for New Century Excellent Talents in University (No.NCET-04-0107).
文摘The vaporization ratios of the slurry at various temperature and partial pressure were calculated with the group-contribution method,and then the phase state of the slurry in the residue fluid catalytic cracking(RFCC) disengager was determined.This research could provide some advices on how to select the technological conditions to decrease the coking in the RFCC disengager.The oil gas temperature and the slurry partial pressure had signifi- cant effects on the vaporization ratio of the slurry.Increasing the oil gas temperature and reducing the slurry partial pressure could effectively slow down the coking speed in the RFCC disengager.According to the calculation results, a correlation was established to predict the vaporization ratio of the slurry under different operating conditions.
基金supported by the National Natural Science Foundation of China (No.50704004)
文摘Vaporization behavior (1163-1463 K) of lead in the slag system of FeO-CaO-SiO2-Al2O3 with CaC% was examined. A thermodynamic estimation with the principle of Gibbs free energy minimization showed that the major vapor species from the sample of the FeO-CaO-SiO2-Al2O3 system+PbO+CaCl2 were metallic Pb, PbCl, PbCl2, and FeCl2, at the experimental temperature range. The experimental results show that the mole ratio of vaporized Cl in lead chlorides to vaporized Pb, simply expressed as Cl/Pb decreases with increasing temperature. The larger Cl/Pb means a larger ratio of gaseous PbCl2, since metallic Pb and PbCl vapors are formed in a similar reduction atmosphere. The evaporation is initially rapid and becomes steady after holding for 10 min. Gaseous PbCl2 is mainly formed during the heating period, and at the holding stage, it reacts with FeO to produce gaseous FeCl2 With regard to slag composition, FeO content and basicity significantly affect the evaporation of lead. High FeO content and high basicity promotes the formation of metallic Pb and PbCI, whereas, it prohibits PbCl2 evaporation.
文摘To investigate the factors that influence treatment satisfaction after high-power potassium-titanyl-phosphate (KTP) laser vaporization of the prostate, we compared the characteristics between patients who were satisfied and those who were not satisfied. In all, 97 patients aged between 53-82 years (median age 67 years) underwent high-power KTP laser vaporization of the prostate for lower urinary tract symptoms due to benign prostatic hyperplasia. At 12 months postoperatively, 60 patients were satisfied with the treatment, whereas 37 were dissatisfied. Although there were no differences in International Prostate Symptom Score (IPSS) values at baseline, the satisfied group scored better in total IPSS at 1, 3, 6, and 12 months postoperatively (P 〈 0.05). At baseline, the maximum flow rate (Qmax) was lower in the dissatisfied group and remained low throughout the follow-up period, with the exception of 1 month postoperatively (P 〈 0.05), compared with the satisfied group. There were no differences in other objective data between the two groups, including post-void residual and the number of voids based on the frequency-volume charts. In a multivariate model, a higher bladder contractility index was associated with a greater likelihood of treatment satisfaction 12 months after high-power KTP laser vaporization (odds ratio 1.024, 95% confidence interval 1.001-1.048, P 〈 0.05). Patients who were not satisfied following the surgery had a smaller improvement in subjective symptoms and Qmax. In addition, our findings suggest that the relative risk of treatment dissatisfaction following high-power KTP laser vaporization was increased in patients with weak detrusor contractility.
文摘A method for determination of trace rare earth elements in biological sample by ICP-AES with tungsten-spiral electrothermal vaporization(TETV-ICP-AES)sampling has been developed in this work. Several influencing factors including desolvation and vaporization parameters,carrier gas flow rate and ma- trix effect were investigated in detail.Under optimal experimental conditions,the detection limits for La,Nd, Gd,Dy,Ho,Yb,Lu and Y were obtained in the range of 10^(-9)~10^(-11) g,and they are comparable to and,in most instances,better than those for the GFAAS and conventional pneumatic nebulisation-ICP-AES.The precision(RSD)obtained for this method is less than 6%.
文摘The past literature on the use of vegetable oils as fuel in diesel engine revealed that utilizing vegetable oil fuels in diesel engines may require property changes in the oil or perhaps, some minor engine modifications or operating changes. This study was conducted to search for the effect of atmospheric oxygen on the puffing and bursting phenomena that occur during vegetable oils droplet vaporization process in their use as fuel in diesel engine. The fiber-suspended droplet technique was used, and the normalized square droplet diameter as well as the temperature evolution vicinity the droplet was analyzed. The results show that puffing and bursting phenomena highly depend on oxygen. In presence of atmospheric oxygen, there is an increase of the puffing and bursting intensity and therefore the evaporation rate of the vegetable oil droplets, but in an inert environment or when the environment is oxygen-depleted puffing and bursting phenomena disappearing and make place of a series of explosions with lower magnitude. The lack of oxygen reduces the thermal degradation, polymerization and oxidation reactions and consequently the vaporization rate of vegetable oils droplets;and could therefore lead to the formation of deposits in the form of polymers. This is unsuitable for their use as a fuel in diesel engines. It can also be concluded that atmospheric oxygen has some positive effects on engine performance and emissions when operating with vegetable oil. These results help to address the challenge for the use of alternative fuels such as non-edible vegetable oils.
文摘A new method for direct determination of lanthanum in solid biological materials by fluorination electrothermal vaporization ICP-AES technique with polytetrafluoroethylene(PTFE) disperser as a fluorination agent has been described. The effect of particle size on the signal intensity of La has been investigated. The vaporization behaviour of lanthanum and the main factors affecting fluorinating vaporization have been observed.Under optimum experimental conditions,the detection limit of La to this method is 2.0 ng/ml,and the RSD is 4.5%.The proposed method has been applied to determining directly trace lanthanum in solid biological standard reference materials without any chemical pretreatment,and the determined values are in good agreement with the certified ones.
基金financially supported by the National ‘‘863’’ Project (Grant No. 2012AA0611401)the program of the Chinese Academy of Sciences (Grant No. KZCX2-YW-JC103)
文摘Three series of laboratory vaporization experiments were conducted to investigate the carbon isotope fractionation of low molecular weight hydrocarbons(LMWHs)during their progressive vaporization.In addition to the analysis of a synthetic oil mixture,individual compounds were also studied either as pure single phases or mixed with soil.This allowed influences of mixing effects and diffusion though soil on the fractionation to be elucidated.The LMWHs volatilized in two broad behavior patterns that depended on their molecular weight and boiling point.Vaporization significantly enriched the ^13C present in the remaining components of the C6–C9 fraction,indicating that the vaporization is mainly kinetically controlled;the observed variations could be described with a Rayleigh fractionation model.In contrast,the heavier compounds(n-C10–n-C12)showed less mass loss and almost no significant isotopic fractionation during vaporization,indicating that the isotope characteristics remained sufficiently constant for these hydrocarbons to be used to identify the source of an oil sample,e.g.,the specific oil field or the origin of a spill.Furthermore,comparative studies suggested that matrix effects should be considered when the carbon isotope ratios of hydrocarbons are applied in the field.
文摘According to graph theory method, new method is proposed for the prediction or vaporization heat at normal boiling point of paraffins with moleeular,atructure, and it is compared with other methods. We predict the. vaporization heat at normal boiling point for 57 different paraffins, and that is compared with experimental data, its overall, absolute average deviation is 0.61%. The result is,superior to other methods.
文摘Using a low power microwave generator(W_(max)=100W) and a Surfatron discharge device, Plasma-polymerized copper phthalocyanine (PPCuPc) film was synthesised from monomer copper phthalocyanine(CuPc) by microwave plasma chemical vaporization deposition(MPCVD) with Ar as incorporation gas. The film was characterized by FTIR and ESCA. The role of dissociation of chemical bond in the polymerization process and the influence of substrate temperature and material on deposition were investigated in some detail.
基金supported by a grant from "The 11th Five-year Plan of Scientific Research" of People’s Liberation Army of China (No. 06MA297)
文摘In this study, the vaporization ratio of the 2-μm laser in the prostatic tissue with benign prostatic hyperplasia was examined in vitro, to explore a technique to estimate the clearance rate of prostatic tissue during the transurethral vaporesection of the prostate. A total of 9 fresh prostatic tissue specimens were obtained by open surgery and the wet weight of the prostatic tissue were measured immediately after the sample collection. Under the simulated conditions of transurethral vaporesection of the prostate by 2-μm laser, each prostate gland was completely vaporesected into fragments with a diameter of less than 1.0 cm in vitro tissue were collected and measured. Then After the vaporesection, the whole fragments of prostatic the lost weight of prostatic tissue, the weight of the collected prostatic tissue and the ratio of the lost weight of prostatic tissue to the wet weight of the prostate glandular organ specimen were calculated. The correlation between the weight of collected prostatic tissue and the weight of the whole glandular organ was analyzed. All the experimental procedures were carried out by one operator. Wet weight of the prostatic gland specimen and the weight of the harvested prostatic tissues after the procedure were recorded. With respect to the wet weight of prostate gland specimen, the percentage of the weight of collected prostatic tissue was (34.45±1.51) %, and the percentage of the lost weight of prostatic tissue was (65.55±1.51)%. Satisfactory linear relationship was observed between the weight of collected prostatic tissue and the wet weight of prostate gland specimen [y=3.245x=6.475 (t=15.097, P=0.000)]. It is concluded that under the simulated conditions of transurethral vaporesection of the prostate by 2-μm laser, the vaporization ratio of prostatic tissue can be calculated on the basis of the weight of collected prostatic tissue, and thereby the clearance of prostatic tissue during the formal operation by 2-μm laser could be quantitatively determined.
文摘A new method for the determination of vanadium in high purity Y2O3 by fluorination assisted electrothermal vaporization-ICP-AES is presented in this paper. After the sample dissolved,the vanadium in the sample solution was coprecipitated with Bi(PDC)_3 at pH 3. 7. The precipitates were made into a slurry with the fluorinating agent PTFE and directly introduced into the graphite furnace for determination. The analytical results were obtained by aqueous calibration curve method. The detection limit of the method is 1. 1 ng/mL, the RSD is 2. 8% (n=10,1 5 ng/mL vanadium solution), and the recovery of vanadium added to real sample is more than 96%.
文摘Many research results have revealed that vaporization pressure has important effects on the formation of the keyhole and molten pool during laser welding. In this paper, based on law of conservation of energy, an innovative physical model is found to calculate the vaporization pressure during laser welding. In this model, vaporization pressure can be calculated according to some characteristics of the spatter particle. These features include the size, velocity and displacement. They can be measured through images taken by high-speed camera. The periods of this pressure also measured by counting opening and closing time of the bottom keyholes. At this welding condition, the typical vaporization pressure is about 20 203 Pa and the period is about 6. 9 ms. The average opening time of bottom keyholes is about 4. 3 ms, and the closing time is about 2. 6 ms.
基金supported by the Japan Society for the Promotion of Science KAKENHI(contract grant numbers:20H04549,19K12822).
文摘A quantitative analysis method of CO_(2) laser treatments promotes laser treatment performance and rapid clinical application of novel treatment devices.The in silico clinical trial approach,which is based on computational simulation of light-tissue interactions using the mathematical model,can provide quantitative data.Although several simulation methods of laser tissue vaporization with CO_(2) laser treatments have been proposed,validations of the CO_(2) laser wavelength have been insuffcient.In this study,we demonstrated a tissue vaporization simulation using a CO_(2) laser and performed the experimental validation using a hydrogel phantom with constant physical parameters to evaluate the simulation accuracy of the vaporization process.The laser tissue vaporization simulation consists of the calculation of light transport,photothermal conversion,thermal diffusion,and phase change in the tissue.The vaporization width,depth,and area with CO_(2) laser irradiation to a tissue model were simulated.The simulated results differed from the actual vaporization width and depth by approximately 20%and 30%,respectively,because of the solubilization of the hydrogel phantom.Alternatively,the simulation vaporization area for all light irradiation parameters,which is related to the vaporization amount,agreed well with the actual vaporization values.These results suggest that the computational simulation can be used to evaluate the amount of tissue vaporization in the safety and effectiveness analysis of CO_(2) laser treatments.