BACKGROUND: The wave form, latency and wave amplitude of visual evoked potentials (VEP) are obviously affected by the stimulative parameters, physiological status of the subjects and anesthetics, thus there are greate...BACKGROUND: The wave form, latency and wave amplitude of visual evoked potentials (VEP) are obviously affected by the stimulative parameters, physiological status of the subjects and anesthetics, thus there are greater normal variations and individual differences. The features of flash VEP (F-VEP) are to be observed. OBJECTIVE: To observe and compare the differences of F-VEP latencies and wave amplitudes between eyes in rabbits, and investigate the correlation with sex and the side of eyes. DESIGN: A comparative animal experiment. SETTING: Department of Neurosurgery, General Hospital of Chinese PLA. MATERIALS: The experiment was carried out in the neurophysiological laboratory of the Institute of Neurosciences, General Hospital of Chinese PLA from September 2004 to February 2005. Thirty big-ear rabbits of clean degree, 15 males and 15 females, weighing 2.0-2.5 kg, were provided by the animal center of the General Hospital of Chinese PLA. METHODS: Viking-IV perioperative monitor and flash stimulator for special use were applied. The rabbits were anesthetized with intramuscular injection of compound ketamine. The recording electrode was placed at 3 mm anterior to exoccipital tuberosity (onion, Oz), and the reference electrode was placed at the ear edge of the same side. The stimulative frequency was 1.9 Hz, and the amplifier was 50 μV; The range of wave filter was 5 Hz for high pass and 100 Hz for low pass; The average overlapping was 200 times, and the analytical time was 250 ms. MAIN OUTCOME MEASURES: Comparison of F-VEP wave forms; F-VEP latencies and wave amplitudes. RESULTS: All the 30 rabbits were involved in the analysis of results. ① Comparison of F-VEP wave forms in rabbits: The F-VEP waves mainly manifested as positive-negative-positive (PNP). The F-VEP manifestations to light stimulations were extremely similar between left and right eyes, and the wave amplitudes of both eyes were obviously increased. ② Determinations of F-VEP latencies and wave amplitudes: There were no significant differences in the latencies and wave amplitudes of F-VEP between the two groups (P > 0.05), the latencies of P1, N1 and P2 waves of left eye were (32.59±2.01), (43.85±4.35) and (66.20±8.13) ms, respectively, and the wave amplitudes of P1, N1 and P2 waves of left eye were (16.45±10.22), (7.93±3.56) and (17.62±8.18) μV. F-VEP latencies were stable with small changes, whereas amplitudes had greater changes. CONCLUSION: ① The latency and wave amplitudes F-VEP were stable with good repetition. ② The latencies and wave amplitudes had no significant differences between males and females, as well as between left and right eyes. Further investigation should be undertaken on the animal and clinical field.展开更多
Purpose: To investigate the variation of visual function in different eccentricities of the visual field in isometropic amblyopes.Method: The stimulus matrix containing 61 hexagons was generated on a monitor. The diam...Purpose: To investigate the variation of visual function in different eccentricities of the visual field in isometropic amblyopes.Method: The stimulus matrix containing 61 hexagons was generated on a monitor. The diameter of the entire stimulating field was approximately 13.6 deg of arc; the frame rate of the monitor was 67 Hz. Every hexagon of the display contained a number of black and white small hexagonal patches which reversed during stimulation. These hexagons were simultaneously but independently modulated in time by the controlling computer program. The flashed elements were selected differently on each frame according to a computer-generated binary pseudo-random time series (m-sequence); the response contributions from each of the individual stimulus elements could be extracted from the cross corre-ation function. Subjects were asked to maintain fixation at the center of the stimulus pattern while each of the hexagons of the display reversed. The VERB system extracted the local responses by展开更多
Objective Evaluate the sensitivity and reliability of visual evoked potential to flash (F-VEP) in detecting bilirubin neurotoxicity and approach the risk parameters of bilirubin neurotoxicity in hyper-bilirubinemia ne...Objective Evaluate the sensitivity and reliability of visual evoked potential to flash (F-VEP) in detecting bilirubin neurotoxicity and approach the risk parameters of bilirubin neurotoxicity in hyper-bilirubinemia newborns. Methods Based on the successful establishment of animal models for acute bilirubin encephalopathy by intraperitoneal infusion of bilirubin with a dosage of 100~200μg/g body weight to 1-week-old guinea pigs, the F-VEP was recorded in animal models and human neonates with hyperbilirubinemia, and the sensitivity and reliability of F-VEP in detecting bilirubin neurotoxicity were evaluated. Results F-VEP features and its P1 latency significantly correlated to brain adenosine triphosphate (ATP) level, neurobeha-vioral and neuropathological changes in experimental bilirubin encephalopathy; neonates with hyperbiliru-binemia showed significant F-VEP changes characterized by absence of P1 or P1 latency prolonged in 1~7-day-old newborns, especially when the jaundice was caused by immun oincompatibility and infectious diseases. Conclusion F-VEP would be a good discriminator for bilirubin neurotoxicity, and can become a promising technique in monitoring bilirubin encephalopathy.展开更多
The preoperative and postoperative PVEP in 79 eyes of 45 patients with three types of congenital namely lamellar cataract, nuclear cataract and total cataract was studied. The results showed that visual acuity of pati...The preoperative and postoperative PVEP in 79 eyes of 45 patients with three types of congenital namely lamellar cataract, nuclear cataract and total cataract was studied. The results showed that visual acuity of patients who could be cooperatively examined was improved significantly after operation. The examination of PVEP revealed that more abnormal wave-formes were found in total cataract group before operation. P1 latencies of low and medium spatial frequencies (140', 70', and 35') became much longe...展开更多
Visual electrophysiology is widely used in clinical ophthalmology. It is also of significant value in the objective assessment of visual function in adult and pediatric cataract patients and for the diagnosis of and r...Visual electrophysiology is widely used in clinical ophthalmology. It is also of significant value in the objective assessment of visual function in adult and pediatric cataract patients and for the diagnosis of and research on retinal and visual pathway diseases. This article systematically reviews visual electrophysiology techniques, their applications in the diagnosis and treatment of adult and pediatric cataracts, and factors influencing the application of visual electrophysiology during surgical treatment for cataracts.展开更多
An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed throug...An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed through this system. Visual performance can be measured electrophysiologically with VEP, which reflects the objective func- tion from the retina to the primary visual cortex. The VEP ts without and with AO correction were preliminarily carried out using this system, demonstrating the great potential of this system in the objective visual performance evaluation. The new system will provide the necessary technique and equipment support for the further study of human visual function.展开更多
The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should b...The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should be considered. The equi-luminance turning curve was established for the recorded visual evoked potentials (VEPs) of the luminance changes of the red and green color stimulus, and the position of the equi-luminance was used to define the kind and degree of color vision deficiencies. In the test of 47 volunteers we got the VEP traces and the equi-luminance turning curves, which was in accordance with the judgment by the pseudoisochromatic plate used in clinic. The method fulfills the objective and quantitative requirements in color vision deficiencies test.展开更多
文摘BACKGROUND: The wave form, latency and wave amplitude of visual evoked potentials (VEP) are obviously affected by the stimulative parameters, physiological status of the subjects and anesthetics, thus there are greater normal variations and individual differences. The features of flash VEP (F-VEP) are to be observed. OBJECTIVE: To observe and compare the differences of F-VEP latencies and wave amplitudes between eyes in rabbits, and investigate the correlation with sex and the side of eyes. DESIGN: A comparative animal experiment. SETTING: Department of Neurosurgery, General Hospital of Chinese PLA. MATERIALS: The experiment was carried out in the neurophysiological laboratory of the Institute of Neurosciences, General Hospital of Chinese PLA from September 2004 to February 2005. Thirty big-ear rabbits of clean degree, 15 males and 15 females, weighing 2.0-2.5 kg, were provided by the animal center of the General Hospital of Chinese PLA. METHODS: Viking-IV perioperative monitor and flash stimulator for special use were applied. The rabbits were anesthetized with intramuscular injection of compound ketamine. The recording electrode was placed at 3 mm anterior to exoccipital tuberosity (onion, Oz), and the reference electrode was placed at the ear edge of the same side. The stimulative frequency was 1.9 Hz, and the amplifier was 50 μV; The range of wave filter was 5 Hz for high pass and 100 Hz for low pass; The average overlapping was 200 times, and the analytical time was 250 ms. MAIN OUTCOME MEASURES: Comparison of F-VEP wave forms; F-VEP latencies and wave amplitudes. RESULTS: All the 30 rabbits were involved in the analysis of results. ① Comparison of F-VEP wave forms in rabbits: The F-VEP waves mainly manifested as positive-negative-positive (PNP). The F-VEP manifestations to light stimulations were extremely similar between left and right eyes, and the wave amplitudes of both eyes were obviously increased. ② Determinations of F-VEP latencies and wave amplitudes: There were no significant differences in the latencies and wave amplitudes of F-VEP between the two groups (P > 0.05), the latencies of P1, N1 and P2 waves of left eye were (32.59±2.01), (43.85±4.35) and (66.20±8.13) ms, respectively, and the wave amplitudes of P1, N1 and P2 waves of left eye were (16.45±10.22), (7.93±3.56) and (17.62±8.18) μV. F-VEP latencies were stable with small changes, whereas amplitudes had greater changes. CONCLUSION: ① The latency and wave amplitudes F-VEP were stable with good repetition. ② The latencies and wave amplitudes had no significant differences between males and females, as well as between left and right eyes. Further investigation should be undertaken on the animal and clinical field.
文摘Purpose: To investigate the variation of visual function in different eccentricities of the visual field in isometropic amblyopes.Method: The stimulus matrix containing 61 hexagons was generated on a monitor. The diameter of the entire stimulating field was approximately 13.6 deg of arc; the frame rate of the monitor was 67 Hz. Every hexagon of the display contained a number of black and white small hexagonal patches which reversed during stimulation. These hexagons were simultaneously but independently modulated in time by the controlling computer program. The flashed elements were selected differently on each frame according to a computer-generated binary pseudo-random time series (m-sequence); the response contributions from each of the individual stimulus elements could be extracted from the cross corre-ation function. Subjects were asked to maintain fixation at the center of the stimulus pattern while each of the hexagons of the display reversed. The VERB system extracted the local responses by
文摘Objective Evaluate the sensitivity and reliability of visual evoked potential to flash (F-VEP) in detecting bilirubin neurotoxicity and approach the risk parameters of bilirubin neurotoxicity in hyper-bilirubinemia newborns. Methods Based on the successful establishment of animal models for acute bilirubin encephalopathy by intraperitoneal infusion of bilirubin with a dosage of 100~200μg/g body weight to 1-week-old guinea pigs, the F-VEP was recorded in animal models and human neonates with hyperbilirubinemia, and the sensitivity and reliability of F-VEP in detecting bilirubin neurotoxicity were evaluated. Results F-VEP features and its P1 latency significantly correlated to brain adenosine triphosphate (ATP) level, neurobeha-vioral and neuropathological changes in experimental bilirubin encephalopathy; neonates with hyperbiliru-binemia showed significant F-VEP changes characterized by absence of P1 or P1 latency prolonged in 1~7-day-old newborns, especially when the jaundice was caused by immun oincompatibility and infectious diseases. Conclusion F-VEP would be a good discriminator for bilirubin neurotoxicity, and can become a promising technique in monitoring bilirubin encephalopathy.
文摘The preoperative and postoperative PVEP in 79 eyes of 45 patients with three types of congenital namely lamellar cataract, nuclear cataract and total cataract was studied. The results showed that visual acuity of patients who could be cooperatively examined was improved significantly after operation. The examination of PVEP revealed that more abnormal wave-formes were found in total cataract group before operation. P1 latencies of low and medium spatial frequencies (140', 70', and 35') became much longe...
基金supported by the Cultivation Projects For Young Teaching Staff of Sun Yat-sen University (12ykpy61)the Pearl River Science and Technology New Star Project of Guangzhou City (Grant No.2014J2200060)the Guangdong Provincial Natural Science Foundation for Distinguished Young Scholars of China (Grant No.2014A030306030)
文摘Visual electrophysiology is widely used in clinical ophthalmology. It is also of significant value in the objective assessment of visual function in adult and pediatric cataract patients and for the diagnosis of and research on retinal and visual pathway diseases. This article systematically reviews visual electrophysiology techniques, their applications in the diagnosis and treatment of adult and pediatric cataracts, and factors influencing the application of visual electrophysiology during surgical treatment for cataracts.
基金supported by the National Natural Science Foundation of China (No. 61378064)the National High Technology Research and Development Program of China (No. 2015AA020510)
文摘An objective visual performance evaluation with visual evoked potential (VEP) measurements was first inte- grated into an adaptive optics (AO) system. The optical and neural limits to vision can be bypassed through this system. Visual performance can be measured electrophysiologically with VEP, which reflects the objective func- tion from the retina to the primary visual cortex. The VEP ts without and with AO correction were preliminarily carried out using this system, demonstrating the great potential of this system in the objective visual performance evaluation. The new system will provide the necessary technique and equipment support for the further study of human visual function.
文摘The equi-luminance of color stimulus in normal subjects is characterized by L-cone and M-cone activation in retina. For the protanopes and deuternopes, only the activations of one relevant remaining cone type should be considered. The equi-luminance turning curve was established for the recorded visual evoked potentials (VEPs) of the luminance changes of the red and green color stimulus, and the position of the equi-luminance was used to define the kind and degree of color vision deficiencies. In the test of 47 volunteers we got the VEP traces and the equi-luminance turning curves, which was in accordance with the judgment by the pseudoisochromatic plate used in clinic. The method fulfills the objective and quantitative requirements in color vision deficiencies test.