期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Online Capacitor Voltage Transformer Measurement Error State Evaluation Method Based on In-Phase Relationship and Abnormal Point Detection
1
作者 Yongqi Liu Wei Shi +2 位作者 Jiusong Hu Yantao Zhao Pang Wang 《Smart Grid and Renewable Energy》 2024年第1期34-48,共15页
The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the... The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the power grid. This paper advances an online CVT error state evaluation method, anchored in the in-phase relationship and outlier detection. Initially, this method leverages the in-phase relationship to obviate the influence of primary side fluctuations in the grid on assessment accuracy. Subsequently, Principal Component Analysis (PCA) is employed to meticulously disentangle the error change information inherent in the CVT from the measured values and to compute statistics that delineate the error state. Finally, the Local Outlier Factor (LOF) is deployed to discern outliers in the statistics, with thresholds serving to appraise the CVT error state. Experimental results incontrovertibly demonstrate the efficacy of this method, showcasing its prowess in effecting online tracking of CVT error changes and conducting error state assessments. The discernible enhancements in reliability, accuracy, and sensitivity are manifest, with the assessment accuracy reaching an exemplary 0.01%. 展开更多
关键词 Capacitor voltage transformer Measurement Error Online Monitoring Principal Component Analysis Local Outlier Factor
下载PDF
Research on resonance fault caused by dc magnetic biasing in ultra high voltage transformer with parallel static var compensator
2
作者 Yang Nan Zhu Zimin Yuan Tiejiang 《Journal of Southeast University(English Edition)》 EI CAS 2020年第3期301-312,共12页
For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing... For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid. 展开更多
关键词 static var compensator ultra-high voltage transformer magnetic biasing resonance fault
下载PDF
Real-Time Error Analysis of Multi-Channel Capacitive Voltage Transformer Using Co-Prediction Matrix
3
作者 Jiusong Hu Ao Xiong +2 位作者 Yongqi Liu Guaxuan Xiao Yi Zhong 《Journal of Power and Energy Engineering》 2025年第1期1-17,共17页
Capacitive voltage transformers (CVTs) are essential in high-voltage systems. An accurate error assessment is crucial for precise energy metering. However, tracking real-time quantitative changes in capacitive voltage... Capacitive voltage transformers (CVTs) are essential in high-voltage systems. An accurate error assessment is crucial for precise energy metering. However, tracking real-time quantitative changes in capacitive voltage transformer errors, particularly minor variations in multi-channel setups, remains challenging. This paper proposes a method for online error tracking of multi-channel capacitive voltage transformers using a Co-Prediction Matrix. The approach leverages the strong correlation between in-phase channels, particularly the invariance of the signal proportions among them. By establishing a co-prediction matrix based on these proportional relationships, The influence of voltage changes on the primary measurements is mitigated. Analyzing the relationships between the co-prediction matrices over time allows for inferring true measurement errors. Experimental validation with real-world data confirms the effectiveness of the method, demonstrating its capability to continuously track capacitive voltage transformer measurement errors online with precision over extended durations. 展开更多
关键词 Capacitive voltage transformers Co-Prediction Matrix High-voltage Measurement error
下载PDF
Design of an Equipotential Shielding 1000 kV Capacitor Voltage Transformer 被引量:4
4
作者 Jianchao Zheng Bo Li +1 位作者 Wei Dong Liming Wang 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期419-426,共8页
With the increase of the operating voltage and enlargement of the size of the capacitor voltage transformer(CVT),the additional measurement error caused by stray capacitance coupling and leakage current along the poll... With the increase of the operating voltage and enlargement of the size of the capacitor voltage transformer(CVT),the additional measurement error caused by stray capacitance coupling and leakage current along the polluted surface of the CVT becomes noticeable.The equipotential shielding CVT(EPSCVT)was proposed and designed by the authors to mitigate these effects.An improved conceptual design option of the EPS-CVT is presented in this paper with special references to this study to improve the shielding effect without the increase of shielding capacitance.A proposed method of non-uniform capacitance configuration can improve the shielding effect significantly without an increase of the external shielding capacitance.Based on this achievement,the potential difference and the capacitive current exchange between the internal measuring system and external shielding systems are significantly reduced.In the evaluation of the shielding effect for the influence of stray capacitance,compared with a conventional CVT with equal capacitance,EPS-CVT can reduce the measurement error by two orders of magnitude.In addition,the measurement error caused by the leakage current can also be greatly reduced,especially for the reduction of the phase angle error.Based on the improved design method,a design scheme for an engineering application is proposed which can achieve effective shielding while ensuring as good a technical performance as the existing CVT. 展开更多
关键词 Additional measurement error capacitor voltage transformer capacitive voltage divider equipotential shielding stray capacitance shielding effect
原文传递
Optical fiber-based power and data delivery system for high voltage electronic current transformer
5
作者 邱红辉 段雄英 邹积岩 《Journal of Shanghai University(English Edition)》 CAS 2008年第3期268-273,共6页
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi... This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request. 展开更多
关键词 high voltage electronic current transformer (ECT) optical power supply delivery system photovoltaic powerconverters supervisory functions
下载PDF
Mitigation of Transients in Capacitor Coupled Substations Using Traditional RLC Filter Techniques
6
作者 Sinqobile Wiseman Nene Bolanle Tolulope Abe Agha Francis Nnachi 《Journal of Power and Energy Engineering》 2024年第5期60-75,共16页
This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly f... This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching. 展开更多
关键词 Capacitor Coupled Substation System Modeling FERRORESONANCE RLC filters Power Electronics Transients Capacitor voltage transformers Transmission Lines
下载PDF
Impact of Sensor Technology for Line Protection Performance
7
作者 Jianping Wang Murari Saha Torbjom Enairsson 《Journal of Energy and Power Engineering》 2014年第4期716-723,共8页
The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structu... The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper. 展开更多
关键词 Distance protection line differential protection current transformer voltage transformer digital substation non-conventional transformer.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部