期刊文献+
共找到8,431篇文章
< 1 2 250 >
每页显示 20 50 100
Design and Development of Wind-Solar Hybrid Power System with Compressed Air Energy Storage for Voltage and Frequency Regulations
1
作者 Banet Masenga Jean Byiringiro +3 位作者 Charles Kagiri Edwell Tafara Daniel Ngoma Gnoumou Aristid 《Journal of Power and Energy Engineering》 2023年第2期1-24,共24页
The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results ... The intermittent nature of wind and solar photovoltaic energy systems leads to the fluctuation of power generated due to the fact that the power output is highly dependent upon local weather conditions, which results to the load shading issue that led to the voltage and frequency instability. In additional to that, the high proportions of erratic renewable energy sources can lead to erratic frequency changes which affect the grid stability. In order to reduce this effect, the energy storage system is commonly used in most wind-solar energy systems to balance the voltage and frequency instability during load variations. One of the innovative energy storage systems is the compressed air energy storage system (CAES) for wind and solar hybrid energy system and this technology is the key focus in this research study. The aim of this research was to examine the system configuration of the CAES system through modelling and experimental approach with PID controller design for regulating the voltage and frequency under different load conditions. The essential elements and the entire system have been presented in this work as thorough modelling in the MATLAB/Simulink environment for different load conditions. The developed model was tested through an experimental workbench using the developed prototype of the compressed air storage in the Siemens Lab at DeKUT and explored the consequence of the working parameters on the system proficiency and the model accuracy. The performance of the system for the developed prototype of CAES system was validated using results from an experimental workbench with MATLAB/Simulink R2022b simulation. The modeling and experimental results, shows that the frequency fluctuation and voltage drop of the developed CAES system during load variations was governed by the I/P converter using a PID_Compact controller programed in the TIA Portal V17 software and downloaded into PLC S7 1200. Based on these results, the model can be applied as a basis for the performance assessment of the compressed air energy storage system so as to be included in current technology of wind and solar hybrid energy systems. 展开更多
关键词 voltage frequency Compressed Air Energy Storage Load Variations PID Control I/P Converter Valve
下载PDF
Research on Inter-turn Short-circuit Fault Diagnosis Method Based on High Frequency Voltage Residual for PMSM
2
作者 Xiaobao Feng Bo Wang +2 位作者 Chaohui Liu Jiayun Zeng Zheng Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第3期256-265,共10页
Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of... Inter-turn fault is a serious stator winding short-circuit fault of permanent magnet synchronous machine(PMSM). Once it occurs, it produces a huge short-circuit current that poses a great risk to the safe operation of PMSM. Thus, an inter-turn short-circuit fault(ITSCF) diagnosis method based on high frequency(HF) voltage residual is proposed in this paper with proper HF signal injection. First, the analytical models of PMSM after the ITSCF are deduced. Based on the model, the voltage residual at low frequency(LF) and HF can be obtained. It is revealed that the HF voltage residual has a stronger ITSCF detection capability compared to the LF voltage residual. To obtain optimal fault signature, a 3-phase symmetrical HF voltage is injected into the machine drive system, and the HF voltage residuals are extracted. The fault indicator is defined as the standard deviation of the 3-phase HF voltage residuals. The effectiveness of the proposed ITSCF diagnosis method is verified by experiments on a triple 3-phase PMSM. It is worth noting that no extra hardware equipment is required to implement the proposed method. 展开更多
关键词 Inter-turn short-circuit fault(ITSCF) Permanent magnet synchronous machine(PMSM) High frequency(HF)injection voltage residual Fault diagnosis
下载PDF
Air target recognition method against ISRJ for radio frequency proximity sensors using chaotic stream encryption
3
作者 Jian-feng Li Jian Dai +2 位作者 Xin-hong Hao Xiao-peng Yan Xin-wei Wang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2023年第10期267-279,共13页
The interrupted-sampling repeater jamming(ISRJ)can cause false targets to the radio-frequency proximity sensors(RFPSs),resulting in a serious decline in the target detection capability of the RFPS.This article propose... The interrupted-sampling repeater jamming(ISRJ)can cause false targets to the radio-frequency proximity sensors(RFPSs),resulting in a serious decline in the target detection capability of the RFPS.This article proposes a recognition method for RFPSs to identify the false targets caused by ISRJ.The proposed method is realized by assigning a unique identity(ID)to each RFPS,and each ID is a periodically and chaotically encrypted in every pulse period.The processing technique of the received signal is divided into ranging and ID decryption.In the ranging part,a high-resolution range profile(HRRP)can be obtained by performing pulse compression with the binary chaotic sequences.To suppress the noise,the singular value decomposition(SVD)is applied in the preprocessing.Regarding ID decryption,targets and ISRJ can be recognized through the encryption and decryption processes,which are controlled by random keys.An adaptability analysis conducted in terms of the peak-to-side lobe ratio(PSLR)and bit error rate(BER)indicates that the proposed method performs well within a 70-k Hz Doppler shift.A simulation and experimental results show that the proposed method achieves extremely stable target and ISRJ recognition accuracies at different signal-to-noise ratios(SNRs)and jamming-to-signal ratios(JSRs). 展开更多
关键词 Interrupted-sampling repeater jamming(ISRJ) Radio frequency proximity sensors(RFPS) Chaotic stream encryption Air target recognition Identity(ID)decryption
下载PDF
Collector optimization for tradeoff between breakdown voltage and cut-off frequency in SiGe HBT 被引量:1
4
作者 付强 张万荣 +3 位作者 金冬月 丁春宝 赵彦晓 鲁东 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期354-358,共5页
As is well known, there exists a tradeoff between the breakdown voltage BVcEO and the cut-off frequency fT for a standard heterojunction bipolar transistor (HBT). In this paper, this tradeoff is alleviated by collec... As is well known, there exists a tradeoff between the breakdown voltage BVcEO and the cut-off frequency fT for a standard heterojunction bipolar transistor (HBT). In this paper, this tradeoff is alleviated by collector doping engineering in the SiGe HBT by utilizing a novel composite of P+ and N- doping layers inside the collector-base (CB) space-charge region (SCR). Compared with the single N-type collector, the introduction of the thin P+ layers provides a reverse electric field weakening the electric field near the CB metallurgical junction without changing the field direction, and the thin N layer further effectively lowers the electric field near the CB metallurgical junction. As a result, the electron temperature near the CB metallurgical junction is lowered, consequently suppressing the impact ionization, thus BVcEO is improved with a slight degradation in fT. The results show that the product of fTXBVcEo is improved from 309.51 GHz.V to 326.35 GHz.V. 展开更多
关键词 SiGe heterojunction bipolar transistors (HBTs) breakdown voltage cut-off frequency collectoroptimization
下载PDF
Multi-objective optimization for voltage and frequency control of smart grids based on controllable loads 被引量:2
5
作者 Yaxin Wang Donglian Qi Jianliang Zhang 《Global Energy Interconnection》 CAS CSCD 2021年第2期136-144,共9页
The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capabi... The output uncertainty of high-proportion distributed power generation severely affects the system voltage and frequency.Simultaneously,controllable loads have also annually increased,which markedly improve the capability for nodal-power control.To maintain the system frequency and voltage magnitude around rated values,a new multi-objective optimization model for both voltage and frequency control is proposed.Moreover,a great similarity between the multiobjective optimization and game problems appears.To reduce the strong subjectivity of the traditional methods,the idea and method of the game theory are introduced into the solution.According to the present situational data and analysis of the voltage and frequency sensitivities to nodal-power variations,the design variables involved in the voltage and frequency control are classified into two strategy spaces for players using hierarchical clustering.Finally,the effectiveness and rationality of the proposed control are verified in MATLAB. 展开更多
关键词 Multi-objective optimization voltage control frequency control Power flow Controllable loads Game theory
下载PDF
Isolated MicroGrid’s Voltage and Frequency Characteristic with Induction Generator Based Wind Turbine 被引量:1
6
作者 Woo-Kyu Chae Hak-Ju Lee +2 位作者 Sung-Wook Hwang Il-Keun Song Jae-Eon Kim 《Smart Grid and Renewable Energy》 2014年第7期180-192,共13页
To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery sys... To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery system, back-up diesel generator, etc., Isolated MicroGrid, which usually uses the inverter to maintain voltage and frequency of the system, is very weak in terms of voltage and frequency stability compared to the large-scale electrical power system. If wind turbine generator is applied to this weak power system, it could experience many problems in terms of maintaining its voltage and frequency. In this paper, the measurement result of voltage and frequency is presented for MicroGrid, which consists of the Wind Turbine Generator adopting the induction generator and the battery system. MicroGrid’s voltage waveform distortion and Wind Turbine Generator’s output oscillation problems are analyzed using PSCAD/EMTDC. Based on the analyzed result, the importance of type and capacity choice has been suggested in case the Wind Turbine Generator is applied to the Isolated MicroGrid. 展开更多
关键词 MICROGRID Wind TURBINE INDUCTION Generator Battery voltage frequency PSCAD/EMTDC
下载PDF
Effects of Bias Voltage on the Structure and Mechanical Properties of Thick CrN Coatings Deposited by Mid-Frequency Magnetron Sputtering 被引量:6
7
作者 容双全 何俊 +3 位作者 王红军 田灿鑫 郭立平 付德君 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期38-41,共4页
Thick CrN coatings were deposited on Si (111) substrates by electron source assisted mid-frequency magnetron sputtering working at 40 kHz. The deposition rate, structure, and microhardness of the coatings were stron... Thick CrN coatings were deposited on Si (111) substrates by electron source assisted mid-frequency magnetron sputtering working at 40 kHz. The deposition rate, structure, and microhardness of the coatings were strongly influenced by the negative bias voltage (Vb). The deposition rate reached 8.96 μm/h at a Vb of -150 V. X-ray diffraction measurement revealed strong CrN (200) orientation for films prepared at low bias voltages. At a high bias voltage of Vb less than -25 V both CrN (200) and (111) were observed. Large and homogeneous grains were observed by both atomic force microscopy and scanning electron microscopy in samples prepared under optimal conditions. The samples exhibited a fibrous microstructure for a low bias voltage and a columnar structure for VD less than -150 V. 展开更多
关键词 CRN middle-frequency magnetron sputtering bias voltage
下载PDF
Development of a Medium Voltage, High Power, High Frequency Four-Port Solid State Transformer 被引量:1
8
作者 Ahmad El Shafei Saban Ozdemir +2 位作者 Necmi Altin Garry Jean-Pierre Adel Nasiri 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第1期95-104,共10页
The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficie... The power and voltage levels of renewable energy resources is growing with the evolution of the power electronics and switching module technologies.For that,the need for the development of a compact and highly efficient solid-state transformer is becoming a critical task in-order to integrate the current AC grid with the new renewable energy systems.The objective of this paper is to present the design,implementation,and testing of a compact multi-port solid-state transformer for microgrid integration applications.The proposed system has a four-port transformer and four converters connected to the ports.The transformer has four windings integrated on a single common core.Thus,it can integrate different renewable energy resources and energy storage systems.Each port has a rated power of 25 kW,and the switching frequency is pushed to 50 k Hz.The ports are chosen to represent a realistic industrial microgrid model consisting of grid,energy storage system,photovoltaic system,and load.The grid port is designed to operate at 4.16 k VAC corresponding to 7.2 kV DC bus voltage,while the other three ports operate at 500 VDC.Moreover,the grid,energy storage and photovoltaic ports are active ports with dual active bridge topologies,while the load port is a passive port with full bridge rectifier one.The proposed design is first validated with simulation results,and then the proposed transformer is implemented and tested.Experimental results show that the designed system is suitable for 4.16 k VAC medium voltage grid integration. 展开更多
关键词 CO-SIMULATION high frequency high power medium voltage MICROGRID MULTI-PORT solid state transformer
下载PDF
Frequency Support from PMSG-Based Wind Turbines with Reduced DC-Link Voltage Fluctuations 被引量:4
9
作者 Jiafa He Linbin Huang +2 位作者 Di Wu Chengzhi Zhu Huanhai Xin 《CES Transactions on Electrical Machines and Systems》 2018年第3期296-302,共7页
Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations ma... Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method. 展开更多
关键词 Current feed forward control DC-link voltage frequency droop control frequency support PMSG-based WTs
下载PDF
Development of OPTO-LDR coupled timer based voltage to frequency converter 被引量:1
10
作者 Akash Kumar Anindya Debnath +4 位作者 Antar Banik Kabirul Islam Mondal Partha Pratim Biswas Rik Bhattacharyya T K Maiti 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第1期17-20,共4页
This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency o... This paper describes the development of a timer based voltage to frequency converter(V FC).Timer LM555is used in astable multivibrator mode with two OPTO-LDRs(light dependent resistors)in the circuitry.The frequency of timer output waveform which is measured using a digital storage oscillator(DSO)is almost linearly proportional to the applied input voltage.Hence we obtain a linear relationship between the frequency of timer output waveform and the input voltage.Because of its quasi-digital output,the main advantages of this developed converter are linear input-output relationship,small size,easy portabilityand high cost performance.In addition,the timer output waveform can be directly interfaced with personal computer or microprocessor/microcontroller for further processing of the input voltage signal without intervening any analog-to-digital converter(ADC). 展开更多
关键词 timer LM 555 astable multivibrator light emitting diode (LED) light dependent resistor (LDR) voltage to frequency converter (V FC) digital storage oscillator (DSO)
下载PDF
Characterization and comprehension of corona partial discharge in air under power frequency to very low frequency voltage
11
作者 周远翔 周仲柳 +3 位作者 张灵 张云霄 莫雅俊 孙建涛 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第5期117-125,共9页
For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.Ho... For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies. 展开更多
关键词 CORONA partial discharge low frequency voltage impulse current method statisticalparameters
下载PDF
Electrical and thermal characterization of near-surface electrical discharge plasma actuation driven by radio frequency voltage at low pressure 被引量:1
12
作者 Zhen Yang Hui-Min Song +2 位作者 Di Jin Min Jia Kang Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期374-385,共12页
The electrical and thermal characterization of near-surface electrical discharge plasma driven by radio frequency voltage are investigated experimentally in this paper. The influences of operating pressure, electrode ... The electrical and thermal characterization of near-surface electrical discharge plasma driven by radio frequency voltage are investigated experimentally in this paper. The influences of operating pressure, electrode distance, and duty cycle on the discharge are studied. When pressure reaches 60 Ton. (1 Torr= 1.33322 x 102 Pa) the transition from diffuse glow mode to constricted mode occurs. With the operating pressure varying from 10 Tort to 60 Torr, the discharge energy calculated from the charge-voltage (Q-V) Lissajous figure decreases rapidly, while it remains unchanged between 60 Torr and 460 Torr. Under certain experimental conditions, there exists an optimized electrode distance (8 mm). As the duty cycle of applied voltage increases, the voltage-current waveforms and Q-V Lissajous figures show no distinct changes. 展开更多
关键词 radio frequency discharge charge-voltage Lissajous figure temperature distribution plasma ac-tuation
下载PDF
Phasor Control of Converter Output Voltage for Frequency Regulation
13
作者 Masahide Hojo Ryo Ikeshita +1 位作者 Yoshinobu Ueda Toshihisa Funabashi 《Journal of Power and Energy Engineering》 2014年第7期19-27,共9页
The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by syn... The synchronizing torque of a power system may be weakened by increasing installation of static power converters accompanied by renewable energy resources because they used to trade their favorable active power by synchronizing their output voltage with the one at the point of common coupling. In the circumstances, a concept of Virtual Synchronous Machine (VSM) is proposed, where the self-commutated power converters are emulating synchronous generators. This paper describes a converter control to contribute to enhancing the synchronizing torque. The proposed control is similar to the VSM but it simply realizes active power trades among power generation units including converter-based generators by modulating phase angles of their output voltages. Therefore, it can provide an effective support to regulate the system frequency where the total rated power of the converter-based generators increases as much as the one of conventional rotating generators like a microgrid. This paper especially focuses on its robustness where the number of converter-based generators is increased or they are dispersed in the power network. The effectiveness is verified by simulation study based on instantaneous values. 展开更多
关键词 Self-Commutated Power CONVERTER SYNCHRONOUS GENERATOR frequency CONTROL voltage PHASOR
下载PDF
A SCHEDULING SCHEME WITH DYNAMIC FREQUENCY CLOCKING AND MULTIPLE VOLTAGES FOR LOW POWER DESIGNS
14
作者 Wen Dongxin Wang Ling Yang Xiaozong 《Journal of Electronics(China)》 2007年第4期572-576,共5页
In this letter, a scheduling scheme based on Dynamic Frequency Clocking (DFC) and multiple voltages is proposed for low power designs under the timing and the resource constraints. Unlike the conventional methods at h... In this letter, a scheduling scheme based on Dynamic Frequency Clocking (DFC) and multiple voltages is proposed for low power designs under the timing and the resource constraints. Unlike the conventional methods at high level synthesis where only voltages of nodes were considered, the scheme based on a gain function considers both voltage and frequency simultaneously to reduce energy consumption. Experiments with a number of DSP benchmarks show that the proposed scheme achieves an effective energy reduction. 展开更多
关键词 Scheduling scheme Dynamic frequency Clocking (DFC) Multiple voltages High level synthesis
下载PDF
Effect of Driving AC Voltage Frequency on Breakdown Voltage in Dielectric Barrier Discharge at Atmospheric Pressure in Helium 被引量:1
15
作者 DAI Dong WANG Qiming 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2235-2240,共6页
For dielectric barrier discharge(DBD)driven by AC voltage in helium at atmospheric,the relationship between the breakdown voltage and the driving frequency is experimentally investigated using a pair of parallel elect... For dielectric barrier discharge(DBD)driven by AC voltage in helium at atmospheric,the relationship between the breakdown voltage and the driving frequency is experimentally investigated using a pair of parallel electrodes.The gap between the electrodes is 1 mm,4 mm,7 mm,and 10 mm,respectively.Meanwhile with an increment of 2 kHz,the applied AC voltage varies from 12 kHz to 30 kHz.In each experiment,the driving voltage increases slowly,till the helium-filled gap breaks down.Based on a number of experimental results and further analyses,conclusions are obtained as follows.(1)For a small gap(1 mm),the voltage that triggers the first breakdown(Uf)is close to the one that sustains steady breakdowns(Us).However,in the larger gaps(4,7,and 10 mm),Uf is obviously larger than Us.(2)For a fixed gap,Uf does not change significantly with the driving frequency,whereas in the gaps except the 1 mm one,Us drastically decreases with the increase of driving frequency.(3)The motion of residual space charges and the dissipation of positive column,two reasonable factors that explains asymmetrical discharges,are also main reasons for the effect of the driving frequency on the breakdown voltages. 展开更多
关键词 击穿电压 驱动频率 大气压 氦气 放电 介质 驾驶 AC
下载PDF
Electrical and dielectric characterization of Au/ZnO/n-Si device depending frequency and voltage
16
作者 I Orak A Kocyigit S Ahndal 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期477-483,共7页
Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series res... Au/Zn O/n-type Si device is obtained using atomic layer deposition(ALD) for Zn O layer, and some main electrical parameters are investigated, such as surface/interface state(Nss), barrier height(Φb), series resistance(Rs), donor concentration(Nd), and dielectric characterization depending on frequency or voltage. These parameters are acquired by use of impedance spectroscopy measurements at frequencies ranging from 10 k Hz to 1 MHz and the direct current(DC) bias voltages in a range from-2 V to +2 V at room temperature are used. The main electrical parameters and dielectric parameters,such as dielectric constant(ε"), dielectric loss(ε"), loss tangent(tan δ), the real and imaginary parts of electric modulus(M and M), and alternating current(AC) electrical conductivity(σ) are affected by changing voltage and frequency. The characterizations show that some main electrical parameters usually decrease with increasing frequency because charge carriers at surface states have not enough time to fallow an external AC signal at high frequencies, and all dielectric parameters strongly depend on the voltage and frequency especially in the depletion and accumulation regions. Consequently, it can be concluded that interfacial polarization and interface charges can easily follow AC signal at low frequencies. 展开更多
关键词 Au/ZnO/n–Si device dielectric properties polarization process frequency and voltage dependence
下载PDF
Multi-channel DMA Based Design of Voltage Monitoring Using Synchronous Frequency Trace-Sampling Technique
17
作者 Yuan Lei Li Lei +4 位作者 Lei Xia Mingxiang Liu Yueming Cai Jingtao Zhao Mengyue Li 《Modern Electronic Technology》 2020年第2期17-20,共4页
In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling techniqu... In order to eliminate the influence of frequency change on real-time voltage acquisition,a low-cost solution of voltage monitoring was proposed using the multi-channel DMA synchronous frequency trace-sampling technique.In-chip resources of the designed voltage monitor were fully utilized in hardware design to reduce external devices.The MQX RTOS was used to perform the functional tasks flexibly and efficiently;especially the Ethernet communication applications and USB device connection were realized using its TCP/IP protocol stack and USB driver.In addition,to ensure the safety of electrical records,data statistics and alarm information management were also implemented through the management of the storage in FLASH.The test results show that the voltage monitor designed in this paper has the advantages of accurate measurement,strong resistance to frequency interference and low cost,and can be widely applied in the field of voltage monitoring in distribution networks. 展开更多
关键词 voltage monitoring DMA Synchronous sampling frequency tracing-sampling MQX RTOS
下载PDF
Finite Frequency Fuzzy H∞Control for Uncertain Active Suspension Systems With Sensor Failure 被引量:5
18
作者 Zhenxing Zhang Hongyi Li +1 位作者 Chengwei Wu Qi Zhou 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2018年第4期777-786,共10页
This paper investigates the problem of finite frequency fuzzy H_∞ control for uncertain active vehicle suspension systems, in which sensor failure is taken into account. TakagiSugeno(T-S) fuzzy model is established f... This paper investigates the problem of finite frequency fuzzy H_∞ control for uncertain active vehicle suspension systems, in which sensor failure is taken into account. TakagiSugeno(T-S) fuzzy model is established for considered suspension systems. In order to describe the sensor fault effectively, a corresponding model is introduced. A vital performance index,H_∞ performance, is utilized to measure the drive comfort. In the framework of Kalman-Yakubovich-Popov theory, the H_∞ norm from external perturbation to controlled output is optimized effectively in the frequency domain of 4 Hz-8 Hz to enhance ride comfort level. Meanwhile, three suspension constrained requirements, i.e., ride comfort level, manipulation stability,suspension deflection are also guaranteed. Furthermore, sufficient conditions are developed to design a fuzzy controller to guarantee the desired performance of active suspension systems. Finally, the proposed control scheme is applied to a quarter-vehicle active suspension, and simulation results are given to illustrate the effectiveness of the proposed approach. 展开更多
关键词 Active vehicle suspension systems finite frequency control sensor failure Takagi-Sugeno fuzzy model
下载PDF
Experimental Verification and Research for the Distortion in the Integrated Frequency Responses of the High-Pressure Sealed Cabin and Magnetic Field Sensor 被引量:4
19
作者 邓明 魏文博 +3 位作者 金胜 叶高峰 张启升 景建恩 《Journal of China University of Geosciences》 SCIE CSCD 2007年第4期310-319,共10页
Although magnetotelluric sounding method applied to the land is advanced, there are many difficulties when it is applied to marine environment, one of which is how to lay magnetic field sensors down to the seafloor to... Although magnetotelluric sounding method applied to the land is advanced, there are many difficulties when it is applied to marine environment, one of which is how to lay magnetic field sensors down to the seafloor to complete measurements. To protect the magnetic field sensors from intense erosion and high pressure, suitable high-pressure sealed cabins must be designed to load them. For the consideration of magnetic measurement and marine operation, the sealed pressure cabin should be nonmagnetic and transportable. Among all optional materials, LC4 super.hard aluminum alloy has the highest performance of price/quality ratio to make the sealed pressure cabin. However, it does not mean that the high-pressure sealed cabin made using LC4 will be perfect in performance. In fact, because of its weak magnetism, the pressure cabin made using LC4 has distorting effect on frequency responses of the magnetic field sensors sealed in it. This distorting effect does not affect the use of the magnetic field sensor, but if we want to eliminate its effect, we should study it by experimental measurements. In our experiment tests, frequency sweep magnetic field as excitation signal was used, and then responses of the magnetic field sensor before and after being loaded into the high-pressure sealed cabin were measured. Finally, normalized abnormal curves for the frequency responses were obtained, through which we could show how the high-pressure sealed cabin produces effects on the responses of the magnetic field sensor. Experimental results suggest that the response distortion induced by the sealed pressure cabin appears on mid- and high-frequency areas. Using experimental results as standardization data, the frequency responses collected from seafloor magnetotelluric measurements can be corrected to restore real information about the seafloor field source. 展开更多
关键词 marine magnetotellurics magnetic field sensor high-pressure sealed cabin frequency response experimental test
下载PDF
Low-frequency characteristics extension for vibration sensors 被引量:2
20
作者 杨学山 高峰 候兴民 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2004年第1期139-146,共8页
Traditional magneto-electric vibration sensors and servo accelerometers have severe shortcomings when used to measure vibration where low frequency components predominate.A low frequency characteristic extension for v... Traditional magneto-electric vibration sensors and servo accelerometers have severe shortcomings when used to measure vibration where low frequency components predominate.A low frequency characteristic extension for velocity vibration sensors is presented in this paper.The passive circuit technology,active compensation technology and the closed- cycle pole compensation technology are used to extend the measurable range and to improve low frequency characteristics of sensors.Thses three types of low frequency velocity vibration sensors have been developed and widely adopted in China. 展开更多
关键词 vibration sensor low frequency characteristic extension passive circuit technology active compensation technology closed-cycle pole compensation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部