期刊文献+
共找到380篇文章
< 1 2 19 >
每页显示 20 50 100
Advanced Treatment of Wastewater Treatment Plant Effluent by Using Biofilms on Filamentous Bamboo 被引量:3
1
作者 SUN Jun-wei HE Zheng-guang +3 位作者 CAO Wen-ping LI Lei YAN Xiao-le JIA Sheng-yong 《Meteorological and Environmental Research》 CAS 2012年第8期40-42,52,共4页
[ Objective ] The study aimed at treating wastewater treatment plant (WWTP) effluent by using bio-film reactor with filamentous bamboo as bio-carrier. [ Method] With the aid of a continuous flow reactor, a bio-film ... [ Objective ] The study aimed at treating wastewater treatment plant (WWTP) effluent by using bio-film reactor with filamentous bamboo as bio-carrier. [ Method] With the aid of a continuous flow reactor, a bio-film reactor using filamentous bamboo as bio-carrier was used to treat WWTP effluent with low C/N ratio, and the removal effects of CODc,, TN (total nitrogen), and NO3--N in the wastewater were analyzed.[ Result ] The average removal rates of CODcr, TN, and NO3- -N reached 47.7%, 23.6% and 34.5% when the C/N ratio of influent was around 2. In addi- tion, a stable bio-film was formed very well in the secondary effluent with low C/N ratio and hardly degradable organic pollutants. The pollutants could be removed effectively because of the excellent surface characteristics and compositions of filamentous bamboo. [ Conclusion] The research provides a new method to treat WWTP effluent with low C/N ratio. 展开更多
关键词 Filamentous bamboo Bio-film process wastewater treatment plant (wwtp effluent Low C/N ratio China
下载PDF
Occurrences of Glucocorticoids in Aquatic Environment and Their Removal during Wastewater Treatment
2
作者 吴清晨 吴世闵 +5 位作者 张茵茵 ANDERE Clement Miruka 朱大海 张艾 刘亚男 薛罡 《Journal of Donghua University(English Edition)》 CAS 2023年第3期293-318,共26页
Glucocorticoids(GCs) are a group of endocrine-disrupting compounds(EDCs) frequently prescribed against various medical conditions.Recently,GCs have been shown to be effective in managing septic shock in patients infec... Glucocorticoids(GCs) are a group of endocrine-disrupting compounds(EDCs) frequently prescribed against various medical conditions.Recently,GCs have been shown to be effective in managing septic shock in patients infected with the 2019 novel coronavirus(COVID-19).Due to colossal consumption and potential risks to aquatic organisms,GCs have immensely attracted the focus of the scientific research community as a water pollutant.Therefore,the aim of this paper is to review the current knowledge on the occurrence of various GCs in the aquatic environment and their removal during wastewater treatment.A variety of GCs are ubiquitous in surface water,hospital wastewater,and sewage water worldwide.And the minimum concentration in volume is below 0.01 ng/L,and the maximum one is 10 000 ng/L,and enter the environment through hospital and urban wastewater discharging.Compared with natural GCs,higher risks to aquatic environments could be induced by synthetic GCs.The current activated sludge processes used in wastewater treatment plants(WWTPs) are not fully effective in eliminating GCs,some of which may further increase the risk of GC in the environment.In comparison with the aerobic process in WWTPs,the anaerobic and anoxic processes were found to be more efficient for GC degradation.Of the studied GCs,fluticasone propionate,clobetasol propionate,fluocinolone acetonide,and triamcinolone acetonide need more attention due to their low removal efficiencies and strong toxicity.Among the advanced treatment processes,reverse osmosis,ultraviolet irradiation,CaO_(2),and plasma could achieve significant GC activity removal while micro/ultra-filtration,chlorination,and ozonation were less efficient. 展开更多
关键词 glucocorticoid(GC) endocrine disrupting compound(EDC) wastewater treatment plant(wwtp) advanced wastewater treatment
下载PDF
Effectiveness of Centralized Wastewater Treatment Plant in Removing Emerging Contaminants: A Case Study at Kuching, Malaysia
3
作者 King Kuok Kuok Po Chan Chiu +2 位作者 Md. Rezaur Rahman Muhammad Khusairy Bin Bakri Mei Yun Chin 《Journal of Water Resource and Protection》 CAS 2022年第9期650-663,共14页
Before the construction of the Kuching Centralized Wastewater Treatment System Package 1 (KCWTSP1), partially treated blackwater and greywater were discharged directly into natural waterways. The accumulated wastewate... Before the construction of the Kuching Centralized Wastewater Treatment System Package 1 (KCWTSP1), partially treated blackwater and greywater were discharged directly into natural waterways. The accumulated wastewater had polluted Sarawak river, which is regulated and cannot discharge freely into the South China Sea. The polluted Sarawak river has endangered human health, river water quality, and aquatic ecosystems. Hence, the KCWTSP1 commissioned in 2015 serves the purpose of removing pollutants from wastewater before it is discharged into natural waterways. However, the effectiveness of KCWTPP1 is unknown. This paper is aimed to discuss and review the effectiveness of KCWTPP1 in treating wastewater since its inception in 2015. From 2017 to 2020, KCWTPP1 has treated an average of 4,200,000 m<sup>3</sup> of wastewater per year. Generally, most of the discharge effluent met Environmental Quality Act (1974) Standard A criteria, except for the oil and grease parameter. Initially, the plant could not treat suspended solids and total phosphorus, but this was greatly improved in subsequent years. Therefore, some improvements are required to treat oil and grease parameters effectively and efficiently to ensure that only Standard A effluent is discharged into the Sarawak River in the future. 展开更多
关键词 Kuching Centralized wastewater treatment plant Package 1 Primary treatment Secondary treatment Tertiary treatment effluent
下载PDF
A global perspective on microbial risk factors in effluents of wastewater treatment plants
4
作者 Kejing Chen Jinsong Liang +3 位作者 Yuhan Wang Yechen Tao Yun Lu Aijie Wang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2024年第4期227-235,共9页
Effective monitoring and management of microbial risk factors in wastewater treatment plants(WWTPs)effluents require a comprehensive investigation of these risks.A global survey on microbial risk factors in WWTP efflu... Effective monitoring and management of microbial risk factors in wastewater treatment plants(WWTPs)effluents require a comprehensive investigation of these risks.A global survey on microbial risk factors in WWTP effluents could reveal important insights into their risk features.This study aims to explore the abundance and types of antibiotic resistance genes(ARGs),virulence factor genes(VFGs),the vector of ARG/VFG,and dominant pathogens in global WWTP effluents.We collected 113 metagenomes of WWTP effluents from the Sequence Read Archive of the National Center for Biotechnology Information and characterized the microbial risk factors.Our results showed that multidrug resistance was the dominant ARG type,while offensive virulence factors were the most abundant type of VFGs.The most dominant types of ARGs in the vector of plasmid and phage were both aminoglycoside resistance,which is concerning as aminoglycosides are often a last resort for treating multi-resistant infections.Acinetobacter baumannii was the most dominant pathogen,rather than Escherichia coli,and a weak negative correlation between Escherichia coli and two other dominant pathogens(Acinetobacter baumannii and Bacteroides uniformis)suggests that using Escherichia coli as a biological indicator for all pathogens in WWTP effluents may not be appropriate.The Getah virus was the most dominant virus found in global WWTP effluents.Our study presents a comprehensive global-scale investigation of microbial risk factors in WWTP effluents,providing valuable insights into the potential risks associated with WWTP effluents and contributing to the monitoring and control of these risks. 展开更多
关键词 wastewater treatment plant Microbial risk factor effluent Pathogen Antibiotic resistance gene Virulence factor gene
原文传递
Impact of wastewater treatment plant effluent discharge on the antibiotic resistome in downstream aquatic environments:a mini review
5
作者 Zhiguo Su Lyujun Chen Donghui Wen 《Frontiers of Environmental Science & Engineering》 SCIE EI CSCD 2024年第3期131-141,共11页
Antimicrobial resistance(AMR)has emerged as a significant challenge in human health.Wastewater treatment plants(WWTPs),acting as a link between human activities and the environment,create ideal conditions for the sele... Antimicrobial resistance(AMR)has emerged as a significant challenge in human health.Wastewater treatment plants(WWTPs),acting as a link between human activities and the environment,create ideal conditions for the selection and spread of antibiotic resistance genes(ARGs)and antibioticresistant bacteria(ARB).Unfortunately,current treatment processes are ineffective in removing ARGs,resulting in the release of large quantities of ARB and ARGs into the aquatic environment through WWTP effluents.This,in turn,leads to their dispersion and potential transmission to human through water and the food chain.To safeguard human and environmental health,it is crucial to comprehend the mechanisms by which WWTP effluent discharge influences the distribution and diffusion of ARGs in downstream waterbodies.In this study,we examine the latest researches on the antibiotic resistome in various waterbodies that have been exposed to WWTP effluent,highlighting the key influencing mechanisms.Furthermore,recommendations for future research and management strategies to control the dissemination of ARGs from WWTPs to the environment are provided,with the aim to achieve the“One Health”objective. 展开更多
关键词 Antibiotic resistance genes(ARGs) wastewater treatment plants(wwtps) effluent-receiving waterbodies Environmental risk Influencing mechanism
原文传递
Why Should We Bother on Measurement in Wastewater Treatment Operation?
6
作者 Stig Morling 《Journal of Water Resource and Protection》 2016年第11期982-989,共9页
The question of wastewater treatment and control is reflected from a very specific viewpoint: the low priority given to accurate and useful measurements within wastewater treatment. The matter is discussed from four v... The question of wastewater treatment and control is reflected from a very specific viewpoint: the low priority given to accurate and useful measurements within wastewater treatment. The matter is discussed from four various perspectives, that may be labelled “Legal understanding”;“Needs for accurate measurement results already in the planning and design stage”;“The measurement problem and human behaviour”;“The understanding of the short term and long term dynamics and changes in pollution and flow loads on a wastewater treatment plant (WWTP)”. All these aspects bring about much improved needs for an accurate and frequent measurement scheme both for pollutants and flows entering a WWTP. The conclusion is stated as follows: A far more and well elaborated on-line measurement system at the plants would become a needed tool for improved water environment protection at lower costs. 展开更多
关键词 MEASUREMENT Legal Issues On-Line Instruments Nitrogen Sludge Systems wwtp (wastewater treatment plant)
下载PDF
Full scale application of combined SBF-AS process for municipal wastewater treatment in small towns and cities in China
7
作者 刘硕 王宝贞 +2 位作者 王琳 丁永伟 周宏均 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第3期347-353,共7页
The combined submerged biofilm (SBF)-activated sludge (AS) process for treatment of municipal wastewater in a small city in China is described in this paper. The process exhibited high removal efficiencies for car... The combined submerged biofilm (SBF)-activated sludge (AS) process for treatment of municipal wastewater in a small city in China is described in this paper. The process exhibited high removal efficiencies for carbonaceous substances, nitrogen and phosphorus which mainly took place in the combined SBF-AS bioreactor. The SBF-AS bioreactor was divided into pre-anoxic, anaerobic, anoxic and aerobic zones from inlet to outlet, in which fixed biofilm carriers were packed. Excellent performance had been obtained under normal operating conditions in more than one year of operation in Dong’e municipal WWTP, Shandong province, with mean removal efficiencies of BOD5 934%, COD 88%, SS 92%, NH+4-N 821%, TP 75% and TN 667%, and quite high effluent quality such as BOD5 6 to 10 mg/L, COD 20 to 40 mg/L, SS 5 to 10 mg/L, TN 10 to 20 mg/L, NH+4-N 4 to 8 mg/L and TP 06 to 10 mg/L. The effluent was reused multi-purposely, such as toilet flushing, green belt watering and artificial lake pounding. Simultaneous nitrification and denitrification took place due to the DO gradient in biofilm in aerobic zone of the SBF-AS bioreactor, which made TN removal efficiency improved remarkably in system. Some activated sludge was returned from final clarifiers to the bioreactor for phosphorus removal. The process had the advantages of low investment and low operational/maintenance (O/M) costs, low sludge yield and was preferably employed in small towns and cities. 展开更多
关键词 小城镇 污水处理厂 废水处理 SBF-AS 生物处理法
下载PDF
Advances in Research of Characteristics and Removal of Microplastics in Sewage Treatment Plants
8
作者 Shasha LIU Jianping FU Yue YANG 《Asian Agricultural Research》 2022年第11期41-47,共7页
Microplastic pollution has become a worldwide issue.The discharge of sewage treatment plants(STPs)or wastewater treatment plant(WWTPs)is an important way for microplastics to enter the environment.This study reviewed ... Microplastic pollution has become a worldwide issue.The discharge of sewage treatment plants(STPs)or wastewater treatment plant(WWTPs)is an important way for microplastics to enter the environment.This study reviewed the sources and occurrence characteristics(type,size,color and components)of microplastics in domestic and foreign sewage plants.It elaborated the removal principles of microplastics by primary,secondary and tertiary treatments.In addition,the removal effects of various treatment units and different processes on microplastics were summarized.In the future,the removal mechanism of microplastics in sewage treatment plants should be discussed in more depth,so as to further improve the removal rate of microplastics by optimizing and transforming traditional sewage treatment processes.Therefore,it is necessary to develop new technologies/processes specifically for the removal of microplastics and promote them to practical applications. 展开更多
关键词 Microplastics Sewage treatment plant(STP) wastewater treatment plant(wwtp) Occurrence characteristics REMOVAL
下载PDF
深圳沙河水质净化厂及3#调蓄池工艺设计要点及特点
9
作者 黄文章 王子龙 《净水技术》 CAS 2024年第6期169-178,共10页
沙河水质净化厂设计规模为旱季10万m^(3)/d,雨季额外处理10万m^(3)/d初期雨水,3#调蓄池设计规模为15.3万m^(3)。污水及初期雨水处理采用预处理+多段厌氧-好氧(AO)+二沉池+磁混凝高效沉淀池+精密过滤+紫外消毒的工艺,出水水质执行深圳市... 沙河水质净化厂设计规模为旱季10万m^(3)/d,雨季额外处理10万m^(3)/d初期雨水,3#调蓄池设计规模为15.3万m^(3)。污水及初期雨水处理采用预处理+多段厌氧-好氧(AO)+二沉池+磁混凝高效沉淀池+精密过滤+紫外消毒的工艺,出水水质执行深圳市地方标准《水质净化厂出水水质规范》(DB 4403/T 64—2020)B级标准,其中总氮(TN)≤8 mg/L。污泥处理采用离心浓缩+低温热干化工艺,处理后含水率≤40%。作为国内首个将水质净化厂与初期雨水调蓄池深度融合的全地下式水污染治理综合体,项目采用多段AO耦合“3W法”(Wet-Weather-Wastewater法),并以此为核心提出了一种实现大规模污水及初期雨水高标准协同处理的系统解决方案,且无需大幅度增加污水处理设施体量、投资和运行成本。 展开更多
关键词 地下式水质净化厂 3#调蓄池 水污染治理综合体 协同处理 多段AO “3W法”
下载PDF
Characteristics of microbial community involved in early biofilms formation under the influence of wastewater treatment plant effluent 被引量:6
10
作者 Yuke Peng Jie Li +2 位作者 Junling Lu Lin Xiao Liuyan Yang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第4期113-124,共12页
Effluents from wastewater treatment plants(WWTPs) containing microorganisms and residual nutrients can influence the biofilm formation. Although the process and mechanism of bacterial biofilm formation have been wel... Effluents from wastewater treatment plants(WWTPs) containing microorganisms and residual nutrients can influence the biofilm formation. Although the process and mechanism of bacterial biofilm formation have been well characterized, little is known about the characteristics and interaction of bacteria, archaea and eukaryotes in the early colonization, especially under the influence of WWTP effluent. The aim of this study was to characterize the important bacterial, archaeal and eukaryotic species in the early stage of biofilm formation downstream of the WWTP outlet. Water and biofilm samples were collected 24 and 48 hr after the deposition of bio-cords in the stream. Illumina Miseq sequencing of the 16 S and 18 S rDNA showed that, among the three domains, the bacterial biofilm community had the largest alpha and beta diversity. The early bacterial colonizers appeared to be "biofilm-specific", with only a few dominant operational taxonomic units(OTUs) shared between the biofilm and the ambient water environment. Alpha-proteobacteria and Ciliophora tended to dominate the bacterial and eukaryotic communities, respectively, of the early biofilm already at 24 hr, whereas archaea played only a minor role during the early stage of colonization. The network analysis showed that the three domains of microbial community connected highly during the early colonization and it might be a characteristic of the microbial communities in the biofilm formation process where co-occurrence relationships could drive coexistence and diversity maintenance within the microbial communities. 展开更多
关键词 wastewater treatment plant effluent Early colonization Archaea Microbial eukaryotes Network analysis
原文传递
智慧水厂能耗监测评价与异常诊断管理平台研究 被引量:1
11
作者 李子怡 钟炜 《给水排水》 CSCD 北大核心 2024年第2期153-157,166,共6页
为提升污水处理厂水处理过程的运行能效,加速推进智慧水厂向节能化、数字化方向转型,设计了一种面向污水处理厂的能耗监测评价与异常诊断管理平台。平台基于建筑信息模型和能耗管理系统,通过采集污水处理厂运行数据与气象数据等信息,建... 为提升污水处理厂水处理过程的运行能效,加速推进智慧水厂向节能化、数字化方向转型,设计了一种面向污水处理厂的能耗监测评价与异常诊断管理平台。平台基于建筑信息模型和能耗管理系统,通过采集污水处理厂运行数据与气象数据等信息,建立基于机器学习算法的动态监督能耗预测模型,实现厂区运行状况实时监测与评价。运维管理人员可依据平台生成的状态评价指数,进行厂区能源结构调整与异常用能识别与诊断。最后,以实际案例数据验证了平台各功能模块的可行性与有效性。分析结果表明,平台预警模块可以监测反馈96%的异常用能情况。 展开更多
关键词 智慧水厂 机器学习 污水特征 能耗预测 异常诊断
下载PDF
污水处理厂中典型肠道病毒的分布与检测方法及其风险评估
12
作者 陈江峰 詹咏 +3 位作者 钱康 陈祥 李锟 董滨 《净水技术》 CAS 2024年第2期27-38,118,共13页
新冠肺炎威胁了全球经济和公众健康,其在粪便和污水中的检出表明了存在粪口传播的可能性。污水在城市污水处理系统中来源广泛,是水传播病毒的重要途径。为进一步开展污水处理设施中病毒的相关研究工作,文中分析了污水处理系统中典型肠... 新冠肺炎威胁了全球经济和公众健康,其在粪便和污水中的检出表明了存在粪口传播的可能性。污水在城市污水处理系统中来源广泛,是水传播病毒的重要途径。为进一步开展污水处理设施中病毒的相关研究工作,文中分析了污水处理系统中典型肠道病毒的定量分布现状,总结了污水处理流程中病毒的灭活机制,并对国内外污水处理厂的肠道病毒研究进展进行归纳。此外,梳理了污水处理厂样本中典型肠道病毒的浓缩及检测方法,最后结合定量微生物风险评价(quantitative microbial risk assessment,QMRA)分析方法,讨论了病毒的浓度、感染概率及其潜在的健康风险。研究对国内病毒排放标准和风险评价体系的建立进行了探讨,为实现污水处理厂肠道病毒全过程风险管理和后续处理处置相关规范的制定提供参考和理论支撑。 展开更多
关键词 肠道病毒 分布特征 检测方法 风险评估 污水处理厂
下载PDF
超薄玻璃基板深加工项目生产废水预处理工程设计
13
作者 程炜 章婷婷 +1 位作者 慕昕志 朱倩倩 《净水技术》 CAS 2024年第4期169-177,共9页
某废水处理工程建设规模为17800 m^(3)/d,文中介绍了该处理工程的概况、工艺流程以及主要构筑物的工艺设计。工程预计进水组成中,工业废水占有相当的比例,主要以电子废水为主。为解决废水可生化性较差、污水处理难度较大的问题,预处理... 某废水处理工程建设规模为17800 m^(3)/d,文中介绍了该处理工程的概况、工艺流程以及主要构筑物的工艺设计。工程预计进水组成中,工业废水占有相当的比例,主要以电子废水为主。为解决废水可生化性较差、污水处理难度较大的问题,预处理采用高效水解工艺,降低工业废水毒性,改善废水可生化性,确保二级处理系统稳定运行。污水处理主体工艺推荐采用较长泥龄延时曝气,强化脱氮两级AO工艺,提高难降解有机物去除率。绝大部分进水都具有强酸性或者强碱性,且酸碱性波动范围较大,容易对污水处理流程造成冲击,对污水处理建构筑物造成较大腐蚀。此外,在废水处理站进水端设置较长停留时间的调节池,对来水进行均质调节,在一定程度上可以使废水的pH处在较为稳定的范围内;在废水处理站设置监测排放池,尾水排放前仍有应急调节pH的可能,确保尾水达标排放。通过技术经济比较论证,本次扩能工程拟采用不同类污水分质组合处理的工艺技术路线,提高处理效率,降低建设及运行成本。采用先进的上流式水解污泥床水解反应池池型,并加盖除臭、景观绿化,收集和处理构筑物内的臭气。调试运行结果表明,项目工艺流程及参数设置能够满足各类废水处理排放要求。 展开更多
关键词 污水处理厂 工业废水 电子废水 工艺流程 除臭
下载PDF
工业园区混合废水处理厂工程设计与探讨:以福建某化工废水处理厂为例 被引量:1
14
作者 戴炜豪 《净水技术》 CAS 2024年第2期126-134,共9页
福建某工业园区污水处理厂二期设计规模为2.0万m^(3)/d,工业园内的废水主要为石化工业废水。经过对工业园废水水质等特点的充分分析,该工程确定了“企业分类收集池+细格栅及曝气沉砂池+调节池(合建事故池)+水解酸化池+初沉池+生物反应池... 福建某工业园区污水处理厂二期设计规模为2.0万m^(3)/d,工业园内的废水主要为石化工业废水。经过对工业园废水水质等特点的充分分析,该工程确定了“企业分类收集池+细格栅及曝气沉砂池+调节池(合建事故池)+水解酸化池+初沉池+生物反应池+二沉池+芬顿高级氧化+三沉池+反硝化深床滤池+加氯消毒”的工艺路线。该工程设计出水水质执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)中的一级A标准,污水厂部分概算工程费用为27906.73万元。该项目结合先进工艺和精细化设计,探讨了工业园区混合污水处理厂的部分设计要点,为国内类似工业污水厂提供一定思路和案例参考。 展开更多
关键词 废水处理厂 工业园区 化工废水 水解酸化 芬顿高级氧化
下载PDF
污水处理过程中双酚A的环境健康风险分析综述
15
作者 秦瑛蔚 刘兵 +3 位作者 胡杨 王静 陈禹兮 史水合 《净水技术》 CAS 2024年第6期20-28,62,共10页
双酚A(BPA)是市政污水处理厂常见的内分泌干扰物。作为一种新污染物,BPA具有低剂量、较高毒性的特征,对生态环境及人类健康存在潜在影响。文章系统总结了污水处理厂中BPA常见去除方法及其特点,通过分析部分污水处理厂再生水中BPA残留现... 双酚A(BPA)是市政污水处理厂常见的内分泌干扰物。作为一种新污染物,BPA具有低剂量、较高毒性的特征,对生态环境及人类健康存在潜在影响。文章系统总结了污水处理厂中BPA常见去除方法及其特点,通过分析部分污水处理厂再生水中BPA残留现状,得出BPA的主要去除途径为污泥吸附和生物降解,且其处理效果受设备参数、操作条件等综合因素影响。文章同时对不同工艺流程中BPA去除效果进行对比分析,指出了深度处理工艺对提高BPA去除效果的重要性。环境健康风险评价表明,现阶段污水处理过程中的BPA对人类健康风险较低,处于可接受范围,但其潜在风险仍值得人们关注,亟需探究科学合理的去除手段和完善的风险评价方法。最后,文章针对污水处理过程中BPA环境健康风险分析方面研究提出了合理化建议。 展开更多
关键词 污水处理厂 双酚A 去除效果 人体暴露 健康风险评价
下载PDF
纯膜MBBR+磁混凝沉淀工艺在广东省某城市污水厂提标改造中的应用
16
作者 李鹏飞 韩建博 +1 位作者 顾凤 周波 《净水技术》 CAS 2024年第3期166-173,共8页
广东省某城市污水处理厂于2003年建成并投入运营,该污水处理厂原工艺为“厌氧UASB+高负荷生物滤池+固体接触池+生物絮凝沉淀池”,随着污水排放标准的不断提升,该污水处理厂提标改造工作迫在眉睫。经过对多种工艺综合比选,确定将原工艺... 广东省某城市污水处理厂于2003年建成并投入运营,该污水处理厂原工艺为“厌氧UASB+高负荷生物滤池+固体接触池+生物絮凝沉淀池”,随着污水排放标准的不断提升,该污水处理厂提标改造工作迫在眉睫。经过对多种工艺综合比选,确定将原工艺提标改造为“纯膜MBBR+磁混凝沉淀”,对提标改造工程开展工程设计,剖析提标改造后污水处理厂的运行效果。结果表明:以“纯膜MBBR+磁混凝沉淀”为主体的提标改造工艺优势显著,可节省面积约为2600 m^(2),提标改造后污水处理厂能够连续稳定运行,出水水质满足《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准和《水污染物排放限值》(DB 44/26—2001)第二时段一级标准的较严值。 展开更多
关键词 城市污水厂 提标改造 纯膜 MBBR 磁混凝 工程化应用
下载PDF
疫情影响下长沙市某污水处理厂水量水质统计分析
17
作者 徐菡玲 王湘 +6 位作者 崔佳 陈积义 陈圆 盛博 易世雄 杨勇 马晶伟 《净水技术》 CAS 2024年第5期100-108,共9页
为保障城市污水处理厂的安全运行和达标排放,文中选取长沙市某污水处理厂近6年进水水量和进出水水质数据进行统计和分析。结果表明:该污水处理厂的日均进水量在2018年—2023年3月近6年期间,于2020年达到最低,主要是受2020年年初新冠疫... 为保障城市污水处理厂的安全运行和达标排放,文中选取长沙市某污水处理厂近6年进水水量和进出水水质数据进行统计和分析。结果表明:该污水处理厂的日均进水量在2018年—2023年3月近6年期间,于2020年达到最低,主要是受2020年年初新冠疫情所采取的封控措施影响;当年的进水水质受疫情和降雨量的双重影响,除2022年外,2020年BOD_(5)、COD_(Cr)和SS浓度较其他年份均大幅下降,而氨氮、TN和TP浓度降低相对较小。2022年进水BOD_(5)和SS低于其他年份可能是受2022年相对严重的疫情和干旱天气的影响,管道中污染物沉积进行厌氧水解导致。以疫情初始的2020年数据为研究对象,该年内各水质指标的进水浓度波动范围较大,总体上在冬季相对较高,在1月底—2月底和夏季偏低。实测出水水质浓度均达到设计出水水质标准,其中SS的去除率最高,而TN的去除率最低,改良式序列间歇反应器(MSBR)能够去除大部分的TN和氨氮。进水BOD_(5)/COD_(Cr)、BOD_(5)/TN和BOD_(5)/TP的平均值分别为0.58、4.95和46.34,1月底—2月底受疫情影响出现短暂的急剧变化,但总体进水可生化性较好、碳源充足,可采用生物除磷工艺。在碳源不足时,为保证出水达标,可考虑化学辅助除磷。研究结果可为疫情影响下类似污水处理厂的设计和运行提供参考。 展开更多
关键词 污水处理厂 水量水质变化 统计分析 新型冠状病毒 长沙市
下载PDF
不同负荷梯度对污水厂活性污泥的产酸性能分析
18
作者 王柯丹 王保生 +3 位作者 蔺洪永 谢佳 黄龙 李海松 《净水技术》 CAS 2024年第4期95-103,共9页
活性污泥发酵产酸有利于实现污泥资源化利用。文中以污水厂活性污泥为研究对象,在污水厂现场采用半连续碱性发酵方法,探究了先低梯度再高梯度长周期提负荷过程中污泥的产酸性能。结果表明:低梯度提负荷运行阶段,第112 d污泥的酸化率达... 活性污泥发酵产酸有利于实现污泥资源化利用。文中以污水厂活性污泥为研究对象,在污水厂现场采用半连续碱性发酵方法,探究了先低梯度再高梯度长周期提负荷过程中污泥的产酸性能。结果表明:低梯度提负荷运行阶段,第112 d污泥的酸化率达到最大值,且乙酸占比为71.67%,游离氨(FA)质量浓度为(208±39)mg/L,低于250 mg/L,对微生物无抑制性。在高梯度提负荷阶段,第192 d污泥的水解率提高至41%,丁酸与戊酸的占比增加,FA质量浓度逐渐升高至450 mg/L时产酸性能下降。低梯度的优势菌Guggenheimella(24.88%)演变为高梯度的unclassified_Clostridiales(37.08%)。此外,当负荷为3250 mg TSS/(L·d)时,挥发性脂肪酸(VFAs)达到最大值(3339 mg COD_(Cr)/L)。经过50 d的稳定运行,污泥的产酸率为(606±30)mg COD_(Cr)/(g VSS)。合适的负荷梯度有助于污泥中有机物在碱性条件下(pH值=10.0±0.05)长期稳定连续生成VFAs。 展开更多
关键词 负荷梯度 污泥 碱性发酵 挥发酸组分 菌群演替 功能基因 污水厂
下载PDF
城市污水处理厂运行决策支持系统(WWTP ODSS~)的介绍和应用 被引量:1
19
作者 徐丽婕 施汉昌 《给水排水》 CSCD 北大核心 2006年第4期105-108,共4页
介绍了基于经验知识和活性污泥数学模型ASMs的城市污水处理厂运行决策支持系统(WWTP ODSS)的开发历程、主要结构功能以及应用情况,重点介绍了ODSS中专家系统和模拟系统在北京市清河污水处理厂的应用实例。ODSS系统集预警、故障诊断、过... 介绍了基于经验知识和活性污泥数学模型ASMs的城市污水处理厂运行决策支持系统(WWTP ODSS)的开发历程、主要结构功能以及应用情况,重点介绍了ODSS中专家系统和模拟系统在北京市清河污水处理厂的应用实例。ODSS系统集预警、故障诊断、过程模拟和预测等多种功能于一体,通过系统内置的溶解氧、回流比和排泥量等单元控制模块实现了前馈-反馈控制策略,为污水处理厂的运行和控制提供有力的指导和支持。 展开更多
关键词 污水处理厂 运行决策支持系(wwtp ODSS ) 故障诊断模拟预测
下载PDF
污水处理厂扩建工程设计及运行实例
20
作者 王兴斌 《城市道桥与防洪》 2024年第1期157-159,168,M0014,共5页
北方某城市污水处理厂设计总规模18.0×10^(4)m^(3)/d,其中扩建工程设计规模8.0×10^(4)m^(3)/d,出水执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准。根据进水水质和排放要求,设计采用“初沉池-多级AO生化池... 北方某城市污水处理厂设计总规模18.0×10^(4)m^(3)/d,其中扩建工程设计规模8.0×10^(4)m^(3)/d,出水执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准。根据进水水质和排放要求,设计采用“初沉池-多级AO生化池-高速气浮池-反硝化深床滤池”工艺。介绍了扩建工程的工艺流程、主要构筑物设计参数、设计特点,并对运行效果进行分析。实际运行数据表明,出水各项指标均能稳定达标,COD、SS、NH_(3)-N、TN、TP平均去除率分别达到88.90%、96.24%、97.31%、78.00%、92.87%。 展开更多
关键词 污水处理厂 扩建工程 工艺流程 设计参数 运行效果
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部